Industrial Ethernet Cables XS5/XS6

Similar documents
Industrial Ethernet Cables XS5/XS6

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

XS2. Round Water-resistant Connectors (M12) Construction (XS2G Soldering Connector Plug Assemblies) Materials and Finish. Ratings and Specifications

HARTING Ethernet cabling cables and connectors, 4 wire

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

CATEGORY 5e CABLING SOLUTIONS

Multi-Media Installation Guide

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Connectivity for Ethernet

STRUCTURED CABLING SYSTEMS (SCS)

Compact Module. Category 6 FTP Cabling System

CATEGORY 6A CABLING SOLUTIONS

Small Circular Connector. JN1/JN2 Series. Dust Cap

CATEGORY 6 CABLING SOLUTIONS

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Magic Patch Patch Leads & Accessories

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

CATEGORY 6A CABLING SOLUTIONS

Connecting cables for valves, round plug connectors Product range overview

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ribbon Cable connector Compliant with MIL Standard

Ribbon Cable connector Compliant with MIL Standard

SECTION 4 TABLE OF CONTENTS

Ribbon Cable connector Compliant with MIL Standard

Non Magnetic Connectors

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

LH1D Series Surface Mount Indicators

Processing Specification MiniBridge IDC

PREMIUM 5e F/UTP PRODUCTS

DINTEK LAN Cabling Systems

Connecting cables NEBS, for sensors

Connecting cables for valves, Sub-D Type codes

BUS UNITRONIC BUS CAN

Cables for robot applications

3M Distribution Box (DDB)

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

Small Circular Connector. JN1W / JN2W Series

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

HighBand 25. TrueNet Category 6 Solutions

Cat.6 4 Pair UTP Cable

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Ribbon Cable connector Compliant with MIL Standard

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

EXPlora. Introduction

VITALink Taped Splice Straight Through Crimp

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Absolute Rotary Encoder E6CP

MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Non Magnetic Connectors Product Catalog

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

Lightweight SMT Miniature Coaxial Connectors 1.4 mm Mated Height

8D with High Frequency Coaxial Contact

Volition TM RJ45 K5e Jacks

HDBT Installation Guide

Ultra-Small Surface Mount Coaxial Connectors mm Mated Height

PL Series. Plastic Push Pull Interconnects

Copper Solution Contents Cabinets Fiber Optic Solution

BTNS TM. FTP Compact Module

CAT 6 Data Wiring System Connectors

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Solid-State Digital Timer

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height

CAT 6 Data Wiring System Connectors

Self--powered Time Counter

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

OCT 15 Rev B

Medium Box for Cable Termination

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

BNC 75 Ohm RF-Connectors

Stainless Steel SMA Connectors Product Catalog

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.

Instructions. Cable with Armor F CAUTION. October Rev A

MiniBridge 1.27 mm Connectors

Cylindrical Photoelectric Sensor CY-100 SERIES

Gel-sealed in-line fiber optic closure

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Ribbon Cable connector Compliant with MIL Standard

Easy and Quick "Checking Power" at the Worksite

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

3 SLiC Aerial Closure with Rubber End Seal

Bus Cables & Industrial Ethernet Cables

Power Injector 1520 Series

FOSC 450 C6 and D6 Closures

Assembly Instructions

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Transcription:

ADR ADR ADR XS5/XS6 Cables and Connectors for EtherCAT and Other Industrial Ethernet Networks CAT6a Ethernet patch cables For in-cabinet use LSZH with standard RJ5 plugs CAT5e Ethernet patch cables For out-of-cabinet use PUR with standard RJ5 plugs PVC with rugged RJ5 plugs PVC with M SmartClick plugs In addition to cables with sockets and robot cables, shield strengthening cables joined. Connection Examples Control panel Ideal for in-cabinet XS6W-6LSZH Ideal for out-of-cabinet XS6W-5PUR XS5 XS6 Standard Connectors Rugged Connectors Rugged Assembly Connectors Standard Connectors XS5 M Connectors (Waterproof)

Features Cables with Standard RJ5 Connectors For details, refer to page. The lineup features LSZH cables* for in-panel wiring and PUR cables for wiring outside of panels. The Standard RJ5 Connectors reduce cable routing space. LSZH cables are AWG6 with an outer diameter of 6. mm. PUR Cables are AWG6 with an outer diameter of 6.0 mm. Cable colors include blue, yellow, or green. LSZH cables are available in lengths from 0. to 0 m and PUR cables are available in 0 lengths from 0.5 to 0 m. Single-shielded cables with individual aluminum tape on each wire pair to reduce EMC interference in industrial environments. Note. PUR cables are double-shielded cables with overall braiding and individual aluminum tape on each wire pair. * Low-smoke zero-halogen cables. Shape of RJ5 Connector Cables with Rugged RJ5 Connectors For details, refer to page 7. Tough latches and RJ5 connectors with strong cable holding strength are used to enable connections outside of control panels. Quad AWG cable with PVC cover of 6.5 mm outer diameter. Double-shielded cables with overall braiding and individual foil shield to reduce EMC interference in industrial environments. Shape of RJ5 Connector PVC Cable with Double Tough latch Overall braiding and individual foil shield Assembly Connectors You can easily assemble Ethernet cables onsite without crimping tools or other special tools. Refer to page for the assembly procedure. Cable Extension Length Standard Connectors (RJ5 Connectors) 6 mm Rugged Connectors (RJ5 Connectors) 89 mm Minimum cable bending radius: 5 mm Minimum cable bending radius: 0 mm

Cables with M Connectors (Waterproof) For details, refer to page 7. Resistance to harsh environments with IP67 protection. SmartClick Connectors that provide one-step (/8th turn) connection are used (compatible with standard M screw connectors). A wide range of variations, such as cables with right-angle connectors and PCB connectors. Cables with sockets and robot cables were added to the series. Shape of M Connector PVC Cable with Double structure Overall braiding and individual foil shield Cables with M Connectors Strengthening Cables specification For details, refer to page 7. Cable specification with strengthened shield for higher noise resistance. Recommended for EtherCAT communications. In addition to a double shield structure, copper foil tape is added to the M connector to improve communication characteristics (see below). Strengthening Cable (Double shield structure + copper foil tape wrapping) <Internal structure> Noise resistance is strengthened by wrapping copper foil tape around the part where the cable in the M connector joins the shield plate. Effectiveness Data for Rugged RJ5 Connectors and M Connectors (Waterproof) The following data is the results of OMRON testing. effectiveness may vary for your environment and application conditions. Comparison of Effectiveness with Product without a Double The following table shows the differences with a structure without a double shield. Higher numeric values show greater shield effectiveness. Frequency (MHz) structure 0.5 5 0 0 Product with single shield 5 db 9 db 5 db 5 db 7 db Product with a double shield (XS5@-T, Category 5E) 6 db 58 db db db 7 db SmartClick is a registered trademark of OMRON Corporation. EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. Other company names and product names in this document are the trademarks or registered rademarks of their respective companies.

Model Number Legend Use this legend when determining the product specifications from the model number. Choose from the model numbers listed in Ordering Information when ordering. XS6W-@ @@@@ 8 SS @@@@CM-@ A B C D E F ATransmission Characteristics 5: Category 5 6: Category 6A BSheath Material LSZH: LSZH PUR: PUR CNumber of Pins 8: 8 pins DCable Attachment Direction SS: Straight/Straight ECable Length* 0: 0. m 0: 0. m 50: 0.5 m 00: m 50:.5 m 00: m 00: m 500: 5 m 750: 7.5 m 000: 0 m 500: 5 m 000: 0 m FSheath Color B: Blue Y: Yellow G: Green * PUR cables are not available for 0.-m and 0.-m cables. Cables with Standard RJ5 Connectors

Ordering Information Appearance Type Category Cable with Connectors on Both Ends (RJ5/RJ5) Cat.6a Cable sheath material LSZH Cable color Cable length (m) Model Blue Yellow Green Cat.5 PUR Green 0. XS6W-6LSZH8SS0CM-B 0. XS6W-6LSZH8SS0CM-B 0.5 XS6W-6LSZH8SS50CM-B XS6W-6LSZH8SS00CM-B.5 XS6W-6LSZH8SS50CM-B XS6W-6LSZH8SS00CM-B XS6W-6LSZH8SS00CM-B 5 XS6W-6LSZH8SS500CM-B 7.5 XS6W-6LSZH8SS750CM-B 0 XS6W-6LSZH8SS000CM-B 5 XS6W-6LSZH8SS500CM-B 0 XS6W-6LSZH8SS000CM-B 0. XS6W-6LSZH8SS0CM-Y 0. XS6W-6LSZH8SS0CM-Y 0.5 XS6W-6LSZH8SS50CM-Y XS6W-6LSZH8SS00CM-Y.5 XS6W-6LSZH8SS50CM-Y XS6W-6LSZH8SS00CM-Y XS6W-6LSZH8SS00CM-Y 5 XS6W-6LSZH8SS500CM-Y 7.5 XS6W-6LSZH8SS750CM-Y 0 XS6W-6LSZH8SS000CM-Y 5 XS6W-6LSZH8SS500CM-Y 0 XS6W-6LSZH8SS000CM-Y 0. XS6W-6LSZH8SS0CM-G 0. XS6W-6LSZH8SS0CM-G 0.5 XS6W-6LSZH8SS50CM-G XS6W-6LSZH8SS00CM-G.5 XS6W-6LSZH8SS50CM-G XS6W-6LSZH8SS00CM-G XS6W-6LSZH8SS00CM-G 5 XS6W-6LSZH8SS500CM-G 7.5 XS6W-6LSZH8SS750CM-G 0 XS6W-6LSZH8SS000CM-G 5 XS6W-6LSZH8SS500CM-G 0 XS6W-6LSZH8SS000CM-G 0.5 XS6W-5PUR8SS50CM-G XS6W-5PUR8SS00CM-G.5 XS6W-5PUR8SS50CM-G XS6W-5PUR8SS00CM-G XS6W-5PUR8SS00CM-G 5 XS6W-5PUR8SS500CM-G 7.5 XS6W-5PUR8SS750CM-G 0 XS6W-5PUR8SS000CM-G 5 XS6W-5PUR8SS500CM-G 0 XS6W-5PUR8SS000CM-G 5

Specifications Materials and Finish Connectors Cables Type Cable with Connectors on Both Ends (RJ5/RJ5)/LSZH Cable with Connectors on Both Ends (RJ5/RJ5)/PUR Item Model XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Rated current Withstand voltage Ambient operating temperature Ambient storage temperature Ambient installation temperature Protective structure Type A (at 50 C),000 VDC for 60 s (leakage current: ma max.) 0 to 75 C 0 to 80 C 0 to 75 C 0 to 80 C 0 to 50 C 0 to 60 C IP0 Cable with Connectors on Both Ends (RJ5/RJ5)/LSZH Cable with Connectors on Both Ends (RJ5/RJ5)/PUR Item Model XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Connector housing Contacts Cover (structured to prevent the tab from breaking) Marking tube PC resin (UL9V-0)/transparent Copper alloy/nickel base, gold plated Brass/nickel plated PA/Black PVC resin (UL9V-0)/transparent Type Dimensions Cable with Connectors on Both Ends (RJ5/RJ5)/LSZH Cable with Connectors on Both Ends (RJ5/RJ5)/PUR Item Model XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Compliant standard IEC 60- /UL IEC 60- Number of cores AWG6 Outer diameter * 6. mm 6.0 mm Sheath color * Blue, yellow, or green Green Sheath material LSZH PUR structure Single shield Double shield *. Outer diameter. *. Sheath. (Unit: mm) Cable with Connectors on Both Ends (RJ5/RJ5) XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G RJ5 5 6 7 8 RJ5 5 6 7 8 L (Cable length) (6) 0.5 0.8 8 8 0.8.8 Marking tube Label 6. dia. Marking tube 6

Cables with Rugged RJ5 Connectors and Cables with M Connectors Model Number Legend Use this legend when determining the product specifications from the model number. Choose from the model numbers listed in Ordering Information when ordering. Cable with Connectors RJ5 Assembly Connectors XS5@-T @-@M@-@@ A B C D E F G H XS6G-T - ABCD E AConnector Shape H: Cable with plug on one end W: Cable with connectors on both ends BType T: Ethernet (mating part: M D coding) CNumber of Pins : pins DContact Plating Specification : Gold plating, 0. μm ECable Attachment Direction (M Connectors) : Straight : Right angle FCable Length A: 0. m B: 0.5 m C: m D: m E: m G: 5 m J: 0 m K: 5 m GConnector Shape 0: M plug on one end : Connectors on both ends: M socket/m plug : Connectors on both ends: M plug/m plug C: Connectors on both ends: M plug/rj5 plug D: Connectors on both ends: RJ5 plug/rj5 plug E: Connectors on both ends: M socket/rj5 plug HCable Specification K: Standard cable (Cable color: ) Y: Standard cable (Cable color: Yellow) KR: Robot cable (Cable color: ) YR: Robot cable (Cable color: Yellow) SS: Strengthening cable (Cable color: Black) AType T: Ethernet BNumber of Pins : pins CContact Plating Specification : Gold plating, 0. μm DCable Attachment Direction : Straight EDegree of Protection : IP0 M Connectors for Panel Mounting XS5P-T @-@ ABCD E AType T: Ethernet (mating part: M D coding) BNumber of Pins : pins CPlating Specification : Gold plating, 0. μm DMounting Method 6: Rear lockingt 7: Front locking ETerminal Shape : DIP terminalst 5: Cable with loose wires (0.5 m) 7

Ordering Information Appearance Cable type Type Cable color Cable length (m) Model Standard Cables Cable with Plug on One End (M Straight) (M Straight/M Straight) (M Straight/RJ5) Cable with Plug on One End (M Right-angle) (M Right-angle/M Right-angle) (M Right-angle/RJ5) (RJ5/RJ5) Yellow Yellow 0.5 XS5H-T-BM0-K XS5H-T-CM0-K XS5H-T-DM0-K XS5H-T-EM0-K 5 XS5H-T-GM0-K 0 XS5H-T-JM0-K 5 XS5H-T-KM0-K 0.5 XS5W-T-BM-K XS5W-T-CM-K XS5W-T-DM-K XS5W-T-EM-K 5 XS5W-T-GM-K 0 XS5W-T-JM-K 5 XS5W-T-KM-K 0. XS5W-T-AM-Y 0.5 XS5W-T-BM-Y XS5W-T-CM-Y XS5W-T-DM-Y XS5W-T-EM-Y 5 XS5W-T-GM-Y 0. XS5W-T-AMC-K 0.5 XS5W-T-BMC-K XS5W-T-CMC-K XS5W-T-DMC-K XS5W-T-EMC-K 5 XS5W-T-GMC-K 0 XS5W-T-JMC-K 5 XS5W-T-KMC-K 0. XS5W-T-AMC-Y 0.5 XS5W-T-BMC-Y XS5W-T-CMC-Y XS5W-T-DMC-Y XS5W-T-EMC-Y 5 XS5W-T-GMC-Y 0.5 XS5H-T-BM0-K XS5H-T-CM0-K XS5H-T-DM0-K XS5H-T-EM0-K 5 XS5H-T-GM0-K 0 XS5H-T-JM0-K 5 XS5H-T-KM0-K 0.5 XS5W-T-BM-K XS5W-T-CM-K XS5W-T-DM-K XS5W-T-EM-K 5 XS5W-T-GM-K 0 XS5W-T-JM-K 5 XS5W-T-KM-K 0. XS5W-T-AMC-K 0.5 XS5W-T-BMC-K XS5W-T-CMC-K XS5W-T-DMC-K XS5W-T-EMC-K 5 XS5W-T-GMC-K 0 XS5W-T-JMC-K 5 XS5W-T-KMC-K 0. XS5W-T-AMD-K 0.5 XS5W-T-BMD-K XS5W-T-CMD-K XS5W-T-DMD-K XS5W-T-EMD-K 5 XS5W-T-GMD-K 0 XS5W-T-JMD-K 5 XS5W-T-KMD-K 8

Appearance Cable type Type Cable color Cable length (m) Model Standard Cables Robot Cables Strengthening Cables Cable with Plug on One End and Socket on Other End (M Straight/M Straight) Cable with Plug on One End and Socket on Other End (M Straight/RJ5) Cable with Plug on One End and Socket on Other End (M Straight/M Straight) (M Straight/M Straight) (M Straight/RJ5) (RJ5/RJ5) (M Straight/M Straight) (M Straight/RJ5) 0.5 XS5W-T-BM-K XS5W-T-CM-K XS5W-T-DM-K XS5W-T-EM-K 5 XS5W-T-GM-K 0 XS5W-T-JM-K 5 XS5W-T-KM-K 0.5 XS5W-T-BME-K XS5W-T-CME-K XS5W-T-DME-K XS5W-T-EME-K 5 XS5W-T-GME-K 0 XS5W-T-JME-K 5 XS5W-T-KME-K 0.5 XS5W-T-BM-KR XS5W-T-CM-KR XS5W-T-DM-KR XS5W-T-EM-KR 5 XS5W-T-GM-KR 0 XS5W-T-JM-KR 5 XS5W-T-KM-KR 0.5 XS5W-T-BM-KR XS5W-T-CM-KR XS5W-T-DM-KR XS5W-T-EM-KR 5 XS5W-T-GM-KR 0 XS5W-T-JM-KR 5 XS5W-T-KM-KR Yellow XS5W-T-DM-YR Yellow Yellow Black Black 0.5 XS5W-T-BMC-KR XS5W-T-CMC-KR XS5W-T-DMC-KR XS5W-T-EMC-KR 5 XS5W-T-GMC-KR 0 XS5W-T-JMC-KR 5 XS5W-T-KMC-KR XS5W-T-EMC-YR 5 XS5W-T-GMC-YR 0.5 XS5W-T-BMD-KR XS5W-T-CMD-KR XS5W-T-DMD-KR XS5W-T-EMD-KR 5 XS5W-T-GMD-KR 0 XS5W-T-JMD-KR 5 XS5W-T-KMD-KR 0.5 XS5W-T-BMD-YR XS5W-T-CMD-YR XS5W-T-DMD-YR XS5W-T-EMD-YR 5 XS5W-T-GMD-YR 0.5 XS5W-T-BM-SS XS5W-T-CM-SS XS5W-T-DM-SS XS5W-T-EM-SS 5 XS5W-T-GM-SS 0 XS5W-T-JM-SS 0.5 XS5W-T-BMC-SS XS5W-T-CMC-SS XS5W-T-DMC-SS XS5W-T-EMC-SS 5 XS5W-T-GMC-SS 0 XS5W-T-JMC-SS 9

Appearance Cable type Type Cable color Cable length (m) Model RJ5 Assembly Connector --- --- XS6G-T- Standard Cables M Connector for Panel Mounting Rear locking --- 0.5 XS5P-T6-5 Front locking --- 0.5 XS5P-T7-5 M Panel-mounting PCB Straight Terminals --- --- XS5P-T6- Cable Bending Data for Robot Cables (XS5W-T-@M@-KR) The following data is the results of OMRON testing for cable bending test conditions. The number of bends may vary for your environment and application conditions. Cableveyor Test Number of bends: 0 million min. 90 Bending Test Number of bends: 6 million min. Travel distance Cable secured to end Cableveyor Cable secured to end Travel speed: Approx. 0 m/min Travel distance: m Cableveyor radius: 75 mm Cable Roller Bending angle: ±90 Speed: Approx. 0 bends/min Roller radius: 60 mm Weight: 500 g Weight 0

Specifications Item * Use the robot cable within a temperature range between 0 C and 70 C to prevent the wires inside the cable from being broken when bending it. Materials and Finish Connectors Cables Type Model Cable with Plug on One End (M) XS5H -T@-@M0-K Cable with Plugs on Both Ends (M/M) XS5W -T@-@M-K, -KR Cable with Plug on One End and Socket on Other End (M/M) XS5W -T@-@M-K, -KR Cable with Plugs on Both Ends (M/RJ5) XS5W -T@-@MC-K, -KR Cable with Plug on One End and Socket on Other End (M/RJ5) XS5W -T-@ME-K Cable with Plugs on Both Ends (RJ5/RJ5) XS5W -T-@MD-K, -KR RJ5 Assembly Connector XS6G -T- M Connector for Panel Mounting XS5P-T@-5 M Panelmounting PCB Straight Terminals XS5P -T6- Rated current A.5 A A Rated voltage 0 V 5 VDC Contact resistance 0 mω max. Insulation resistance,000 MΩ min. 500 MΩ min.,000 MΩ min. Withstand voltage,000 VAC for 60 s (leakage current: ma max.),500 VAC for 60 s (leakage current: ma max.) Ambient operating temperature 5 to 70 C* Ambient storage temperature 5 to 70 C Protective structure M: IEC IP67, RJ5: IEC IP0 Model M RJ5 Item XS5H and XS5W XS5P-T@-5 XS5P-T6- XS5W and XS6G Contact blocks PBT resin (UL9V-0)/light gray PA resin (UL9V-0)/black PA resin (UL9V-0)/black Contacts Phosphor bronze/nickel base, gold plated (0. μm) Brass/nickel base, gold plated (0. μm) Anchors Zinc diecast/nickel plating --- Anchors (tabs) SUS --- Cover TPE (Thermo Plastic Elastomer) /black --- Sealing resin --- Epoxy resin --- O-rings Rubber --- Grounding fixture --- Phosphor bronze/nickel base, tin plated (.0 μm) --- Anchor cover --- SUS --- Nuts --- Brass/nickel plated --- Phosphor bronze/nickel base, gold plated (. μm) Model Item Standard Cables Robot Cables Strengthening Cables Compliant standard UL CM Category Category 5e Core/color AWG (7/0.6): AWG (7//0.05): AWG (7/0.6): Yellow Orange White Blue Yellow Orange White Blue Yellow Orange White Blue Outer diameter* 6.5 dia. Sheath color*, Yellow Black Sheath material PVC structure Double shield SF/UTP Note. For the XS5H and XS5W, cables are available only with connectors attached. *. Outer diameter. *. Sheath.

Dimensions (Unit: mm) Cable with Plug on One End (M Straight) XS5H-T-@M0-K Terminal No. Color Yellow White Orange Blue.7 (Plug).9 dia. M Cable with Plugs on Both End (M Straight/M Straight) XS5W-T-@M-K XS5W-T-@M-KR XS5W-T-@M-Y XS5W-T-@M-YR M straight M straight.7.7 (Plug).9 dia..9 dia. M M (Plug) (M Straight/RJ5) XS5W-T-@MC-K XS5W-T-@MC-KR XS5W-T-@MC-Y XS5W-T-@MC-YR M straight RJ5 6.7 5.7 (Plug).9 dia. M RJ5 Cable with Plug on One End and Socket on Other End (M Straight/M Straight) XS5W-T-@M-K XS5W-T-@M-KR M straight.7 50.7 M straight (Plug).9 dia..9 dia. M M (Socket) Cable with Plug on One End and Socket on Other End (M Straight/RJ5) XS5W-T-@ME-K 50.7 5.7 M straight RJ5 6.9 dia. (Socket) M RJ5

XS5/XS6 Cable with Plug One End (M Right-angle) XS5H-T-@M0-K.5 Terminal No. Color Yellow White Orange Blue..9 dia. M (Plug) (M Right-angle/M Right-angle) XS5W-T-@M-K.5.5 M right angle M right angle...9 dia..9 dia. M M (Plug) (Plug) (M Right-angle/RJ5) XS5W-T-@MC-K.5 5.7. RJ5.9 dia. (Plug) M M right angle RJ5 6

(RJ5/RJ5) XS5W-T-@MD-K XS5W-T-@MD-KR XS5W-T-@MD-YR RJ5 6 RJ5 6 5.7 5.7 RJ5 RJ5 (M Straight/M Straight) Strengthening Cable XS5W-T-@M-SS M straight M straight.7.7.9 dia..9 dia. M M (M Straight/RJ5) Strengthening Cable XS5W-T-@MC-SS M straight RJ5 6.7 5.7.9 dia. M RJ5

RJ5 Assembly Connector XS6G-T- 5.6.8. 8. Contact 6 Contact Contact Contact Applicable wires Sheath outer diameter: 6. to 6.9 mm Core size: AWG to AWG (stranded wires) AWG to AWG (solid wires) Insulation outer diameter:.6 mm max. M Connector for Panel Mounting XS5P-T@-5 XS5P-T6-5 (Rear Locking) M PG9 7.8 8.6 dia. 500 Orange 8 White 0 Terminal No. Color Yellow White Orange Blue (Socket).5..9 0± (0) Blue Yellow Panel Cutout Dimension +0. 5. 0 dia. 0 XS5P-T7-5 (Front Locking) 8 (Socket) M.9 dia..8 PG9 500 0.5..5 0± (0) Orange Blue 7 White 8 Yellow Panel thickness t = to Note : The panel cutout dimension is the same for Front-locking and Rearlocking Connectors. Note : Rotational positioning is not possible for connector rotation. M Panel-mounting PCB Straight Terminals XS5P-T6- Mounting Hole Dimensions (D Cut Structure) Mounting Hole Dimensions Pin No. M 9.9 0..5 0.6 +0. 0 B (Socket) 5 6.5 dia..6 dia..5 5. +0. 0 0.5 min. A A C C B.±0.0 dia. 5.±0.05 dia..±0.05 dia. Cross-section Diagram A-A 0.5 min..±0.0 dia. 5 to to Cross-section Diagram C-C Cross-section Diagram B-B Panel Processing Dimensions 5 ± +0. Four,. 0 dia. +0. Three,. 0 dia. +0. 0 dia. 8.5 ±0.05 5±0.05 dia..5 ±0.05 5 ±0.05 7.05 ±0.05 5

Assembly Procedure RJ5 Assembly Connectors XS6G-T-. Pass the cable through the cable clamp and the connector housing. Strip the cable sheath and ground braiding to the correct lengths.. Follow the color codes and prepare to insert the wires into the splice piece.. Insert the wires into the splice piece for the length of the splice piece. 5. Place the splice piece into the RJ5 data module and engage it. 6. Place the data module and the splice piece on the IDC assembly housing. 7. Press the data module and the IDC assembly housing together and use pliers or a similar device to make the insulation displacement contact. 8. Remove the data module from the IDC assembly housing. 9. Place the upper screen plate on the data module and press it over the ground braiding of the cable. 0. Place the lower screen plate on the bottom of the data module, align it with the upper screen place, and latch it until you hear it click into place.. Slide the housing that you placed around the cable in step up to the data module and latch it until you hear it click into place.. Tighten the cable clamp. mm mm M Panel-mounting PCB Straight Terminals XS5P-T6- Confirming the Number of Parts The following four parts are included in the package when it is delivered. Panel-mounting Parts PCB-mounting Part. Anchor. O-Ring. Nut. Connector Assembly Procedure. Mount the connector to the PCB.. Attach the anchor to the panel with the nut. Mounting the Connector to the PCB Mounting the Anchor to the Panel PCB. Attach the connector that you mounted to the PCB to the panel. * Make sure that the connector and anchor are oriented correctly. Attachment. Temporarily mount the O-ring to the top of the connector at the mating surface. Temporary Mounting of the O-Ring Align the flat surface on the anchor with the grounding fixture terminal. O-ring Anchor Panel Nut *Tightening torque: N m 5 mm Pin Assignments Pin Assignments for Fast Ethernet 0/00 Mbps Wire color Function/Signal Industrial Ethernet EIA/TIA 568A EIA/TIA 568B Pin No. Transmission Data+/TD+ YE WH/GN WH/OG Transmission Data-/TD OG GN OG Receiver Data/RD+ WH WH/OG WH Receiver Data/RD BU OG GN 6 5. Mate the Connector Waterproof Cover (XSZ-, sold separately) or the Partner Connector Plug (XS5H-T@-@M0-K, sold separately) and press the O-ring to the O-ring position after mounting. Mounting the O-Ring O-Ring Position after Mounting Connector Waterproof Cover (Sold Separately) XSZ- * Tightening torque: 0.9 to 0.9 N m 6

Safety Precautions Precautions for Correct Use Do not use the Connectors in an atmosphere or environment that exceeds the specifications. Connector Connection and Disconnection When connecting or disconnecting Connectors, be sure to hold the Connectors. Do not hold the cable when disconnecting Connectors. When joining Connectors, be sure to insert the plug all the way to the back of the socket before attempting to lock the Connectors. Do not use tools of any sort to join the Connectors. Always use your hands. Pliers or other tools may damage the Connectors. Handling Precautions Do not pull on the Connectors or cables with excessive force. Do not install the Connectors with a load placed directly on the joint or at the point where the wires connect to the Connector. The Connector may be damaged or the wires in the cable may be disconnected. Lay the cable where it will not be stepped on to prevent the wires in the cable from being disconnected and to protect the Connectors from being damaged. If the cable must be placed where it will be stepped on, install a protective cover. When bending cables, do not exceed the cable specifications. Lay the cables so that external force is not applied to the Connectors. Otherwise, the degree of protection (IP67) may not be achieved. Degree of Protection for M/Smartclick Connectors The degree of protection of Connectors (IP67) is not for a fully watertight structure. Do not use the Connectors underwater. Do not step on or place any objects on the Connectors. Doing so may damage the Connectors. 7

OMRON Corporation Industrial Automation Company Kyoto, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, JD Hoofddorp The Netherlands Tel: ()56-8-00/Fax: ()56-8-88 OMRON ASIA PACIFIC PTE. LTD. No. 8A Alexandra Road # 05-05/08 (Lobby ), Alexandra Technopark, Singapore 9967 Tel: (65) 685-0/Fax: (65) 685-7 OMRON ELECTRONICS LLC 895 Greenspoint Parkway, Suite 00 Hoffman Estates, IL 6069 U.S.A. Tel: () 87-8-7900/Fax: () 87-8-7787 OMRON (CHINA) CO., LTD. Room, Bank of China Tower, 00 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 000, China Tel: (86) -507-/Fax: (86) -507-00 OMRON Corporation 00-07 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_9_5_08 Printed in Japan Cat. No. G09-E-07 07 (070)