X-Band Redundant LNB Systems

Similar documents
C-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Modular Block Converter Systems

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

ModuMAX SSPA Systems C, X, and Ku-Bands

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

Redundant LNB Systems

Instruction Manual Model BlockUpconverter

Redundant LNB Systems

Multiple Band Outdoor Block Up- and Downconverters

Instruction Manual Model # Block Upconverter

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Redundant LNB Systems

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

10MHz Source/Inserter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Typical applications:

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

High Performance Outdoor Test Translators

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model /29S RF Splitter

Indoor Dual Converter

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

SATCOM FIBER OPTIC PRODUCTS

Redundant LNB Systems

Instruction Manual Model Downconverter

1/3 RACK-MOUNTED BLOCK CONVERTERS

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Satellite Up- and Downconverter Indoor / Outdoor

MULTIBAND 1/3 RACK-MOUNTED

Synthesized Block Up- and Downconverter Indoor / Outdoor

TELEDYNE Paradise Datacom A Teledyne Technologies Company

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Synthesized Block Up- and Downconverter

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

SYNTHESIZED COMMUNICATION CONVERTERS

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

Instruction Manual Model UHF, L-Band, Up/Downconverter

High-Value 100 Series (Outdoor)

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Instruction Manual Model Up/Downconverter

DA : Series of Narrowband or Wideband Distribution Amplifiers

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

L-Band Block Up- and Downconverter Indoor / Outdoor

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

R-1580A Microwave Downconverter. Product Brochure

Model P/03P Upconverters

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

The Art of Engineering

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Instruction Manual Model Block Downconverter

Instruction Manual Model Block Up/Downconverter

Wideband LNB: 2.4 GHz

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Inmarsat Downconverter Narrowband Downconverter

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Instruction Manual Model Block Upconverter

16W Ku-band Matchbox BUC

ex 800 Series ematrix System

Instruction Manual Model Upconverter

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Truck router (3Gbps/HD/SD/ASI)

THE ART OF ENGINEERING

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ThinkRF D GHz RF Downconverter

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Product Catalogue January 2018

INSTRUCTION MANUAL. MODEL Downconverter

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

Natural-sounding telephone audio... Hybrids

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model

Noise Detector ND-1 Operating Manual

Satellite Up- and Downconverter

Satellite Up- and Downconverter

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

FOM-9010, FOM-9011 and FOM-9012

PONA 3000 Series Erbium Doped Fiber Amplifier

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

ACION 8000 Series. A8KFR1 1RU Forward Receiver

Transcription:

X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon failure of a primary LNB. A 1:1 system provides one spare LNB for one primary LNB. A 1:2 system provides a spare LNB for either of two primary LNBs. The systems consist of an outdoor plate assembly which mounts at the antenna hub, an indoor control panel and interconnecting control cable. Plate Assembly Features Norsat X-Band PLL or externally referenced LNBs High quality dual waveguide/coaxial switches Manual override Waveguide input flanges Output coaxial isolators standard Transmit reject filter(s), input crossguide coupler(s), input isolator(s), and offline I/O options available Redundancy Controller Features 10/100 Base T Ethernet network interface Supports SNMP v1, v2c, and v3 Rack-mount chassis, 19" wide, 1¾" (1 RU) high Dual, redundant power supplies Manual or automatic operation Monitors unit currents, external alarms, or both Automatically switches RF path to standby unit when unit failure occurs User-selectable RS-232/-422/-485 serial I/O M&C interface Parallel I/O M&C interface Menu-driven user configuration of all options Front panel graphically depicts switch positions and unit status Worldwide universal AC input capability standard; consult factory for DC prime power Audible alarm CE certified and RoHS compliant; EAR 99 System Block Diagrams 1:1 System RF IN (CPR112G) TEST IN -40 db OFFLINE IN CONTROLLER 1:2 System POL 1 IN (CPR112G) TEST IN -40 db POL 2 IN (CPR112G) TEST IN -40 db OFFLINE IN CONTROLLER TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY CONTROL/STATUS TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY CONTROL/STATUS LNB 1 LNB 2 LNB 1 LNB 3 LNB 2 RF OFFLINE EXT. REF. IN (DEPENDENT ON LNB SELECTON) POL 1 POL 2 OFFLINE EXT. REF. IN (DEPENDENT ON LNB SELECTON)

System Specifications * Parameter Notes Min. Nom./Typ. Max. Units Input Frequency Range 7.25 7.75 GHz Output Frequency Range 950 1450 MHz Local Oscillator Frequency 6.30 GHz External Reference A 10 MHz -5 +5 dbm Noise Temperature, System At +23 C See Table 1 Versus temperature See Table 2 Gain Standard LNB 60 63 db Gain Flatness Per 27 MHz ±0.5 db Gain Stability Per day, constant temp ±0.2 db Versus temperature -0.05 db/ C VSWR Input, no isolator(s) 2.00 :1 Input, with isolator(s) 1.25 1.30 :1 Input, with isolator(s) and Tx reject filter(s) 1.30 1.35 :1 Output 1.50 2.00 :1 Power Output At 1 db compression (P 1 db) +2 +5 dbm Third Order Intercept Output (OIP 3) +12 +15 dbm Frequency Stability -40 to +60 C ±12.5 khz Phase Noise 1 khz offset -75 dbc/hz 10 khz offset -85 dbc/hz 100 khz offset -95 dbc/hz Maximum Input Power Without damage 0 dbm Connectors RF Input CPR112G Waveguide Flange RF Output (Note B) Offline In, Coupler In Type N Female (50 ohm) Offline Out (Note B) Temperature Range Switch Plate Assy -40 +60 C * System specifications depend on choice of LNB and various options. Specifications shown are for a typical system using commercially available LNBs. Order LNBs separately by model number or frequency range. When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. A Applicable to systems using externally referenced LNB models. B Type F Female (75 ohm) or Type N Female (50 ohm). 2

Part Number/Ordering Information (Copy and FAX this page to General Dynamics.) BRX-1000 Standard system includes: Plate O&M Test LNBs* Controller Assy Manual Data 1100 = 1:1 System 2 1 1 1200 = 1:2 System 3 1 1 * Specify LNB Model number: (Order separately.) Options Available: Cable length ft or m (Up to 500 ft [150 m] in 50 ft [15 m] increments) Waveguide input isolator(s) Transmit Reject Filter(s) Input Crossguide Coupler(s): 40 db (standard), db (custom) Offline LNB Input/Output Ports Remote Control Panel (RCP) Cable for Remote Panel: ft or m (Up to 4000 ft [1200 m] in 50 ft [15 m] increments) Additional O&M Manuals, Qty.: ±48 Vdc Power Option Table 1 Typical System Noise Temperature with Various Options (Add to T LNB )** System 1:1 1:2 Configuration: Pol. 1 Pol. 2 Standby Standard Configuration (Add to T LNB)... 7 K... 7 K 8.5 K 10 K With 40 db Crossguide Coupler(s)... Add 1 K to Standard Configuration With Transmit Reject Filter(s)... Add 8 K to Standard Configuration With Waveguide Isolator(s)... Add 7 K to Standard Configuration ** General Dynamics has found that commercial X-Band LNBs may measure up to 10 K higher than stated noise temperature. Consequently, General Dynamics cannot guarantee system noise performance. Table 2 Noise Temperature vs. Ambient Temperature Noise temperature vs. ambient temperature can be found from the equation, where: NT 2 /NT 1 = (T 2 /T 1 ) n NT 2 = Noise Temperature at T 2 NT 1 = Noise Temperature at T 1 T 2 = Temperature 2 in K T 1 = Temperature 1 in K n = 1.5 for the LNBs or = 1.0 for passive losses For the case where T 1 = 296 K (+23 C), the ratio NT 2 /NT 1 is shown in the table below for both LNBs (n = 1.5) and for passive losses (n = 1.0): Ambient Temperature T 2 ( C) n = 1.5 NT 2 /NT 1 n = 1.0 NT 2 /NT 1 0 0.89 0.92 +23 1.00 1.00 +40 1.09 1.06 +50 1.14 1.09 +60 1.19 1.13 Example: For a 1:1 system with Tx filter and 60 K LNBs, T LNB = 60 K at +23 C and passive losses = 15 K at +23 C; thus, T SYS = 75 K at +23 C. What is T SYS at +50 C? From the table, NT 2 /NT 1 at 50 C = 1.14 for the LNBs and 1.09 for the passive losses: NT 2 = 1.14 x (60 K) + 1.09 x (15 K) = 68.4 K + 16.4 K = 84.8 K at +50 C. 3

Redundant System Controller 1:2 Redundant System Controller, Model RSC12V1-AC The RSC series redundant system controllers for 1:1 and 1:2 systems directly power the LNBs and monitor the output voltages and currents to detect faults. The RSC can also monitor external alarm signals or a combination of output currents and external alarm inputs. Upon detecting a fault, the RSC drives an RF transfer switch to activate the spare unit. The RSC offers monitoring and control of auxiliary RF hardware; remote monitor and control via network, serial interface, or parallel I/O; flexible configuration of system behavior; remote disable of local controls for security; and the ability to detect and report certain failures within the controller itself. A second RSC can be linked to a primary RSC to provide full system control from an alternate control site. When set up this way, the secondary RSC is referred to as a remote control panel, or RCP. The configuration and settings of the primary RSC are transferred to the RCP, which then mimics its controls and interfaces. This permits system operation from a location that is up to 4000 ft (1200 m) distant from the primary controller. Controller Specifications Unit Status Monitor Methods Unit Current Window Width Switchover Time Unit Power Outputs Switch Drive Outputs External Alarm Inputs Serial I/O Interface Controller can monitor unit bias current; alarm is generated if current goes outside of allowed tolerance window. Controller can also monitor external alarm inputs or combinations of both internal unit current and external alarm inputs. ±5% to ±25% of nominal; user selectable in 5% steps (applies to all monitored unit currents) 100 ms maximum +14.3 to +15.0 Vdc, 700 ma maximum -22 to -28 Vdc, 2 A maximum Optionally up to one per unit; require sinking 5 ma at 5 Vdc to negate alarm RS-232/RS-422/RS-485 2- or 4-wire; user selection Parallel I/O Interface Control inputs: Contact closures to ground; require sinking 20 ma at 15 Vdc Status outputs: Form C dry contacts; 100 Vdc, 0.5 A, 3 W max (resistive load) Controller Dimensions Chassis Slides Cable Length to Plate Assy AC Input (standard) DC Input (option) 19 (483 mm) W x 1.72 (43.7 mm) H x 17.5 (445 mm) D; 7.6 lb (3.4 kg) Standard. Radio relay rack-mount brackets available on request. Order cable separately. 100 ft (30 m) to 250 ft (75 m) lengths in 50 ft (15 m) increments are standard; other lengths (up to 500 ft or 150 m) are available by special order. 90-264 Vac, 47 63 Hz, 100 W; Dual AC inputs and dual redundant power supplies. Requires DC-AC inverter. Consult factory. Temperature Range Operating: 0 to +50 C (indoor equipment environment) Storage: -40 to +70 C Relative Humidity Operating: 5% to 95% non-condensing Altitude Reliability Up to 10,000 ft (3000 m) above mean sea level MTBF: 48,200 hours; MTTR: less than 30 minutes with spares and proper technical person. 4

Controller Front Panel Controls and Indicators Unit Status Alarms PS Indicator Panel Test RF Switch Pushbuttons and Indicators Auto/Manual Switch and Indicators Remote/Local Switch and Indicators LED Indicators glow green when OK, red when a fault is detected. Glows red to show fault with either dual redundant power supply. Pushbutton lights all indicators & tests audible alarm. Pushbuttons are used to manually switch units. Front panel indicators show which units are on-line. Unit indicators light red to show faulted units. In a typical 1:1 system, Unit 1 is the primary unit and Unit 2 is on standby. In a 1:2 system, Unit 1 is the primary unit for Pol 1 and Unit 2 is the primary unit for Pol 2. Unit 3 is on standby and can be selected for either Pol. In a dual 1:1 system, Unit 1 is the primary unit and Unit 2 is on standby for Pol 1; Unit 3 is the primary and Unit 4 is on standby for Pol 2. In Auto mode, a unit failure initiates automatic switchover to the standby unit. In manual mode, the on-line unit can be selected from the front panel or by serial I/O, parallel I/O or network command. Selects local (front panel) control, or remote control from serial I/O, parallel I/O, or network. An optional second RSC, configured as a Remote Control Panel, provides the means to operate the system from a physically distant, alternate location. Controller Rear Panel Interfaces 100-135/180-240 V; 47-63 Hz; 1.5A Fusing 100-135V: 250V 2A SLO-BLO 180-240V: 250V 1A SLO-BLO Consult O&M manual for installation instructions. Refer servicing to qualified personnel. J6 SERIAL LOOP J9 NETWORK J1 J2 J3 PLATE ASSY J7 SERIAL I/O J5 REMOTE LINK J4 EXT ALARM J8 PARALLEL I/O J1, J2 LINE 1, LINE 2 (IEC 320-C14) J3 PLATE ASSY (37-pos D, Female) J6 SERIAL I/O and J7 SERIAL LOOP (9-pos D Female) J5 REMOTE LINK (9-pos D Male) J9 NETWORK (RJ-45) J4 EXT ALARM (9-pos D Female) J8 PARALLEL I/O (37-pos D Male) Dual power entry modules contain the AC line input connectors. System can be powered from separate AC lines if desired. Either or both power supplies are capable of operating the system. Cable to plate assembly carries unit power (for line drivers, LNAs or LNBs) and switch drive signals. Order cable separately. Standard lengths are 100 (30 m) to 250 (75 m) in 50 (15 m) increments; other lengths are special order. An adapter cable mates the controller to legacy system cables. RS-232/RS-422/RS-485 connector for user M&C System. Commands provide monitoring, controlling, and configuration. Interconnect cable lengths to 4000 ft (1200 m) with RS-422 or RS-485. A serial loop connector provides a convenient connection for daisy-chained systems. For connection via a proprietary RS-422 link (up to 4000 ft/1200 m) to an optional, second RSC, which duplicates Local control functions at a secondary site. 10/100 Base T Ethernet connection port via standard RJ-45 connector. Supports SNMP v1, v2c and v3. External Alarm inputs. Substitute for or combine with internal unit current monitor alarms. Allows an external signal to indicate unit failure. Unused inputs can be used as status inputs to M&C system. Parallel I/O (discrete logic) connection for limited control and monitoring of the system. Form C relay contact outputs (1:2 system example): Unit 1 status PS 1 status Pol 1: Unit 1 or Unit 3 Unit 2 status PS 2 status Pol 2: Unit 2 or Unit 3 Unit 3 status Local/Remote mode Auto/Manual mode Control inputs contact closure to ground (1:2 system example): Pol 1 Unit 1 select Pol 2 Unit 2 select Auto/Manual select Pol 1 Unit 3 select Pol 2 Unit 3 select 5

1:1 Plate Assembly Outline Drawing, with Various Options Installed 13.00 [330] OPTIONAL TRANSMIT REJECT FILTER 4.00 [101.6] OPTIONAL INPUT CROSSGUIDE COUPLER 32.39 [823] 2.62 [66.5] WAVEGUIDE MOUNTING SURFACE OPTIONAL INPUT ISOLATOR 0.75 x 0.28 SLOT [19 x 7] (4 PLACES) 11.25 [285.7] 9.25 [234.9] 1.53 [38.8] 1.00 [25.4] 0.50 [12.7] 3.71 [94.2] 6.00 [152.4] 7.00 [177.8] 7.42 [188.3] NOTES: 1. OPTIONAL TRANSMIT REJECT FILTER, INPUT CROSSGUIDE COUPLER, SYSTEM INPUT ISOLATOR, AND OFFLINE I/O SHOWN. 2. DIMENSIONS ARE IN INCHES AND [mm]. 8.80 [223.5] TO CONTROL PANEL 0.13 [3.2] OPTIONAL OFFLINE INPUT TYPE N FEMALE RF INPUT TYPE F FEMALE OR TYPE N FEMALE OPTIONAL OFFLINE PUT TYPE F FEMALE OR TYPE N FEMALE Outline 19485-1 6

1:2 Plate Assembly Outline Drawing, with Various Options Installed 13.00 [330] OPTIONAL TRANSMIT REJECT FILTERS OPTIONAL INPUT CROSSGUIDE COUPLERS 4.00 [101.6] 32.40 [823] 2.62 [66.5] WAVEGUIDE MOUNTING SURFACE OPTIONAL INPUT ISOLATORS 11.25 [285.7] 9.25 [234.9] 0.75 x 0.25 SLOT [19 x 7] (4 PLACES) 1.53 [38.8] NOTES: 1.00 [25.4] 6.00 [152.4] 0.50 [12.7] 6.00 [152.4] 7.00 [177.8] 19.00 [482.6] 1. OPTIONAL TRANSMIT REJECT FILTERS, INPUT CROSSGUIDE COUPLERS, SYSTEM INPUT ISOLATORS, AND OFFLINE I/O SHOWN. 2. DIMENSIONS ARE IN INCHES AND [mm]. 3.50 [88.9] 5.00 [127] 5.00 [127.0] 10.99 [279.1] 4.02 [102.0] TO CONTROL PANEL OPTIONAL OFFLINE INPUT TYPE N (F) POL 1 PUT TYPE F FEMALE OR TYPE N FEMALE POL 2 PUT TYPE F FEMALE OR TYPE N FEMALE 0.13 [3.2] OPTIONAL OFFLINE PUT TYPE F FEMALE OR TYPE N FEMALE Outline 19486-1 7

Other Products Solid-State Power Amplifiers and SSPA Systems Solid-State Power BUCs and SSPB Systems Low Noise Amplifiers and LNA Systems Low Noise Block Converters and LNB Systems Block Up and Block Down Converters Synthesized Converters Line Drive Amplifiers Power Supply Monitors Redundant Control Panels for SSPAs, SSPBs, and LNAs 60 Decibel Road, Suite 200 State College, PA 16801 USA Tel. +1-814-238-2700 FAX +1-814-238-6589 19481 Rev. D Email: satcom@gd-ms.com www.gdsatcom.com/electronics.php 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners.