DEVELOPMENT OF A 270 kv XLPE CABLE SYSTEM FOR HVDC APPLICATION

Similar documents
640 kv extruded HVDC cable system

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems

640 kv XLPE HVDC cable system

CHAPTER 3. HV and EHV Cable System Aging and Testing Issues

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

HIGH VOLTAGE CABLE ACCESSORIES - Application, Design, Installation, Testing - Ivan Jovanovic G&W Electric Company

CLP s first 400kV XLPE cable application

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

High Temperature Operation of Extruded Distribution Cable Systems. White Paper

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

3M Sensored Termination (15 kv) QX-T15I-vi1-E

TOSHIBA Industrial Magnetron E3328

HVDC cable accessories

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Diagnostic & Testing Services

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

TIME DOMAIN SPECTROSCOPY (TDS) AS A DIAGNOSTIC TOOL FOR MV XLPE UNDERGROUND LINES

CATHODE-RAY OSCILLOSCOPE (CRO)

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

MPI Cable Selection Guide

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Modular pulse operated latching relay 16 A

CHAPTER 4 OSCILLOSCOPES

17 Bulk Cables INSTRUMENT CABLES SS/ONE CS/535 CS/ SS/ONE SONIC SOLUTIONS HIGH DEFINITION INSTRUMENT CABLE MADE IN ITALY

Electro-Optic Beam Deflectors

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

Detailed Design Report

Flygt Submersible Motor Cables

High Voltage Cables kv. Handling and Operating Instructions

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Interface Connectors for Miniature, Portable Terminal Devices

Highly Accelerated Stress Screening of the Atlas Liquid Argon Calorimeter Front End Boards

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Generator protection relay

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Nuclear Instruments and Methods in Physics Research A

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Catalogue Ignitors and power switches for HID

Joint paper: Feasibility and technical aspects of partial undergrounding of extra high voltage power transmission lines

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

FP_B.1_BorougePte Ltd _Medium voltage XLPE cable for long and reliable service life

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

The field cage for a large TPC prototype

Comparative Analysis of Organic Thin Film Transistor Structures for Flexible E-Paper and AMOLED Displays

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

SCR Characteristics Trainer NV6530 Learning Material Ver 1.1

MILLITARY SPECIFICATION SHEET

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

ANALYSIS OF FAILURE IN POWER CABLES FOR PREVENTING POWER OUTAGE IN ALEXANDRIA ELECTRICITY DISTRIBUTION COMPANY IN EGYPT

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

On-Line Monitoring of Cable Trench and Cable Pit by Using Metal Armored FBG Temperature Sensors

C I R E D 19 th International Conference on Electricity Distribution Vienna, May Transition Joints Behaviour. Paper 457 INTRODUCTION


A New 4MW LHCD System for EAST

Development of high power gyrotron and EC technologies for ITER

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

Emerging Subsea Networks

Habiasense. Cables for measurement applications

Lecture 17 Microwave Tubes: Part I

RZ1-K BS EN XLPE LSZH Flexible Cable

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

3M Super 23 Electrical Tape

I. Introduction. II. Problem

SHIELDED DIGITAL CABLES (1249C SERIES)

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

Condition Monitoring Program of HV Cable Systems

An introduction to Kabeldon cable accessories kv

Thyratrons. High Energy Switches. Features. Description

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Installation Guide VL-MV10. Model No.

Instrumentation Cables

The Cathode Ray Tube

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

CPI Gyrotrons For Fusion EC Heating

INSTRUMENT CATHODE-RAY TUBE

SURGE PROTECTIVE DEVICES

LONWORKS Fibre Optic Converter

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LMT X1 - a 12.1" VHB

Development of OLED Lighting Panel with World-class Practical Performance

AS09..S 3-pole Contactors - Spring Terminals

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

This work was supported by FINEP (Research and Projects Financing) under contract

Transcription:

DEVELOPMENT OF A 270 kv XLPE CABLE SYSTEM FOR HVDC APPLICATION Mohamed MAMMERI, Marie Laure PAUPARDIN, Bernard POISSON, Silec Cable, Montereau, France, mohamed.mammeri@sileccable.com,marie-laure.paupardin@sileccable.com, bernard.poisson@sileccable.com Bertrand VISSOUVANADIN, Laboratoire LAPLACE Toulouse, France, bertrand.vissouvanadin@laplace.univ-tlse.fr ABSTRACT A type test qualification has been performed on a full cable system, including a 1000 mm² aluminium conductor cable with 17 mm insulation thickness and accessories (moulded field joint and terminations). The joint used during the test campaign took advantage from the LDPE experience gained on the EHV 225 kv AC networks. The test was carried out on a 270 kv system according LCC converter type protocol of CIGRE recommendations TB 219. The cable system passed successfully and allows to a qualification for both technologies VSC and LCC. The authors will present the main characteristics of the system in test, and details the results obtained KEYWORDS Space charge, XLPE, PEA, VSC, LCC. INTRODUCTION Today, DC seems more suitable than AC for long length high voltage power transmission. Indeed, multiple losses such as capacitive loss encountered in AC can be drastically reduced by working in DC [1]. Using polymers as insulation for HVDC cable is a challenge for a number of researchers and manufacturers due to the multiple advantages brought over current oil-filled paper insulation. There are, however two main reasons why the traditional paper type cable has been used for transmission of energy for DC application. The first one is a fairly restricted market dominated by paper insulation that fit in satisfactorily with the need. Thus the profitability of the investments required to developed synthetic insulation HVDC cable was not proved. The second one is related to the only technical point of view due to the insufficient knowledge of the extruded synthetic material s behaviour under DC stress. Space charges formation under DC stress is certainly the major concern for such a material. The space charges build up may modify the electric field distribution inside the insulation and leads to local overstresses unsuitable to long-run ability. In addition the introduction of VSC technology where the power flow reversal occurs without changing polarity of the cable encourages the use of synthetic insulated cables. During last years many progress for semi-conductive and insulation polymeric materials were done and insulation technology was significantly improved as well. Sileccable started the study to develop materials and technology for extruded insulation cables in years 90s [2]. Measurement techniques are now available and the spatial distribution of space charge was deeply investigated, applying PEA technology (Pulsed Electroacoustic Analysis). The intention of the present study is to explore the possibility to use plaques and model cable for characterisation of the dc electrical properties. The focus of the paper is to asses the reliability of XLPE insulation cable system subjected to high dc electric stress with polarity reversal. This paper describes the development process of 270 DC XLPE Cable systems with the results of the type tests qualification according Cigre recommendations TB 219. EXPERIMENTAL PEA system for plaque samples Space charge measurements have been performed using the Pulsed Electro-Acoustic (PEA) method. The method consists in detecting and analyzing the acoustic waves generated by the interaction between the space charge in the material and an applied electric pulse. Further information about the technique is given in [3, 4]. The test bench set up is given in fig. 1 Fig.1: PEA Test bench for plaque specimen up to 30 kv The samples were submitted to dc poling voltages in the range 5 to 20 kv, corresponding approximately to applied fields 10 to 40 kv/mm. A polarity reversal is performed after the step of 40 kv/mm. Voltage ramp-up and ramp-down were 1 kv/mm/s. Data

acquisitions were performed only when the voltage is stabilized (not during the ramps). PEA profiles were recorded regularly during the poling lasting for 3h at each voltage step (including volt-off measurement) followed by a depolarization period with the sample grounded. Fast data acquisition (1 profile every 5 seconds) is performed at the beginning of each polarization or depolarization step. Polarization / depolarization cycles, as depicted in Fig. 2, were applied consecutively on the same sample. RESULTS AND DISCUSSION Space charge results for plaque samples Plaques of XLPE with a thickness of about 500 μm are obtained by crosslinking the blend at 180 C for 15 min under a press. Then fresh XLPE samples are degassed at 50 C for 3 days to remove high boiling point by-product residues. Finally, gold electrodes are deposited onto the samples by sputtering. The effect of degassing is illustrated in Fig. 4 in case of degassed and non-degassed XLPE. FTIR analysis shows that an important proportion of acetophenone and cumyl alcohol can be removed by degassing the sample for 2 days at 50 C. Fig. 2 : Applied voltage protocol for an insulation with a thickness of 500μm and acquisition procedure illustration. Each voltage step lasts for 3h. PEA Space charge characteristics on model cable The pulsed acoustic method has been investigated to measure space charge distribution on three layers model cable with insulation 4,5 mm. A 50 mm² copper conductor was used in this cable. The model cable was submitted to DC poling voltage of negative 80 kv corresponding to, approximately 25 kv/mm electric field at conductor screen. The conductor was heated to 70 C. The space charges profiles were recorded during the poling lasting for 5400 s followed by a depolarization period lasting 1800 s. The test bench set up is given in fig. 3. Fig. 4: FTIR spectrum of degassed and non-degassed XLP samples cross-linked. For 10 and 20 kv/mm, positive charges are accumulated in the bulk of the insulation and positive heterocharges are observed adjacent to the cathode (see Fig. 5). This kind of space charge distribution suggests that electric field is enhanced at the cathode and relaxed at the anode. Furthermore, these charges seem deeply trapped as an important quantity of the original charges. Negative charges close to the anode are no more observed, these could be neutralised by some positive injected charges at the anode. Fig.3: Test bench up to 100kV DC for cable model

Inter electrode spacing ( m) voltage Anode No space charge 180 min Cathode polarization depolarization Positive space charge C A polarity reversal time negative positive Charge density C/m³ 1.4 1.35 1.3 Polarity reversal 1.25 1.2 1.15 1.1 1.05 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 Polarity reversal 0.6 0 500 1000 1500 Fig. 6: FEF evolution in plaque samples during the poling and polarity reversal, respectively. - FEF >1 at the cathode during the poling - FEF <1 at the anode during the poling - Strong field enhancement at the cathode upon polarity reversal - Strong field reduction at the anode upon polarity reversal To provide an estimate of the kinetics of trapped charges release, we have considered the time evolution of the space averaged charge density, taken in absolute value, during the depolarization phase. Fig. 5: Spatial distribution of Space charge in plaque samples during the poling and depolarization, respectively. - Positive space charge accumulation in the bulk of the material - Electric field enhancement at the cathode and field relaxation at the anode. According to Fig. 7, trapped charges are released very slowly, that could be due to the presence of deep level traps within the insulation. However, the nature of these traps is unknown (whether it is structural or chemical). It has been found useful to combine the spatial distribution of space charge to the measurement of a parameter known as Field enhancement factor (FEF). FEF is defined as a ratio of the field at a given location with and without space charge. A material with FEF=1 is the preferred choice for DC application. In case of heterocharges accumulation close to the electrode, the electric field will be higher than the Laplace field resulting in FEF values > 1. The FEF evolution given in fig. 6 is a result of the space charge cartography shown in fig. 4. The positive space charge increases the field at the cathode at each voltage step inducing FEF>1. On the other side, the positive homo-space charges decrease the field at the anode at each voltage step allowing to FEF<1. A strong field enhancement at the cathode is recorded upon polarity reversal, due to the positive space charge previously accumulated in the bulk. After the polarity reversal, a positive bulk charge is gradually building up close to the cathode. This phenomenon, referred to as mirror charge effect, has been reported by different authors [5, 6]. In parallel, a strong field reduction at the anode occurs upon polarity reversal, due to the positive space charge previously accumulated in the bulk. Fig. 7: Decay of the volume-averaged trapped charges density after different voltage stress in XLPE. B. Space charge results for model cable Comparative space charge measurements in model cable were carried out at 25 kv/mm when the conductor was heated at 20 C and 70 C respectively. The horizontal axis in the graph shows the distance in mm from the inner to the outer semi conductive layer. Space charge profiles realised during poling indicates that hetero-space charge is accumulated at the anode as well as at the cathode Fig.8

ρ (C/m 3 ) Fig. 8: Voltage-on space charge density in model cable poled at 25 kv/mm at 20 C Fig. 9 shows a spatial space charge distribution in presence of gradient of temperature during the depolarization period. Negative hetero space charge is observed at the anode (external electrode) only. The electric field is enhanced inducing FEF>1. The accumulated hetero-space charge disappears at the cathode (inner electrode). ρ (C/m 3 ) 1.5 1 0.5 0-0.5-1 -1.5 1.2 1 0.8 0.6 0.4 0.2 0-0.2 Heterospace charges 5 6 7 8 9 10 r(mm) Fig. -0.4 10: Voltage-off space charge density in model cable 4 5 6 7 8 9 10 11 during depolarization r(mm) step at 70 C Fig. 9: Space charge density in model cable with gradient of temperature during the polarization period FULL SIZE SYSTEM Electrical withstand of model cable The use of extruded insulation cables in the HVDC links showed a large increase during last years, due to some advantages that polymeric insulation can offer in comparison to traditional laminated. Despite to these advantages, development of extruded cables application for HVDC was hampered by sensitivity for the cables to polarity reversal. This was generally attributed to the presence of space charge trapped within cable insulation. Silec Cable has developed and tested in the early 90 s a solution for LCC based on Low Density Polyethylene. The knowledge acquired during previous years gave us confidence about use of extruded cables also with polarity reversals. In the second part of the study, model cables having 50 mm² copper conductors, with 4.5 mm of insulation thickness were produced and submitted to an extensive test program. - d.c. dielectric strength, - Lightning Impulses test - HVDC life test with thermal cycles at 95 C with polarity reversals. Tests Average d.c.dielectric strength (polarity -) Light Impulses test - polarity + - polarity - kv/mm 67 182 > 130* *: value limited by laboratory termination withstand Table 1: Mean breakdown gradient on model cable Different semi-conductive and insulation polymeric materials were submitted to HVDC life tests with thermal cycles at 95 C with polarity reversals. The duration tests reached 60 heating cycles with 60 polarity reversals under a mean gradient of 30 kv/mm. No breakdown or flashover was detected during the tests. Qualification of a 270 kv cable system In the third part of the project, the best combination of the complex semi-conductive and insulating materials was used to produce a full-size, 1000 mm² aluminium conductor cable with 17 mm insulation thickness. The terminations are entirely synthetic. They are fitted with elastomeric sheds, a deflecting cone and a linear voltage distribution device. The joint is the trickiest part to develop. Regarding to space charges behaviour, a special emphasis is given to the moulded field joint (Fig.10). Moulded joints avoid the problems of interfaces and can be of the same diameter than the cable. Indeed, the technique of rebuilding of the joint is based on the use of the same insulation as the cable. This confers to the moulded joint a great homogeneity, avoiding the problems of interface harmful to a good behaviour under D.C. current. Fig. 10: 270 HVDC moulded joint The tested joints during the test campaign were rigorously identical to those installed on the EHV 225kV AC networks, for which the technique of manufacture had been previously developed (1500 in service worldwide)

These joints (Fig. 11) are adapted to 225kV AC applications therefore they have an intrinsic basic impulse level higher than 1050kV. It is noted that in the case of return of experience field, an examination with EDF of a 225 kv AC moulded joint installed in 1975 (Perret Baudry link) didn t reveal any signs of deterioration. Fig. 11: 225 kv AC moulded joint The type test qualification of the HVDC cable system on the 270 kv level is focused on LCC (Line Commutated Converter) converter type, where polarity reversals were applied during heat cycling. The cable systems consisting of a length of approximately 45 m of cable 1000 mm² Aluminium XLPE (17 mm thick) equipped with a moulded field joint and two outdoor type terminations see Figure 12 3 cycles at 1.85 x 270 = +500 kv, (24/24 h heating /cooling) Superimposed surge voltage test: Udc = +270 kv, Up2o = -380 kv, 10 times Udc = -270 kv, Up2o = +380 kv, 10 times Superimposed Lightning Impulse Withstand Test: Udc = +270 kv, Up1 = -450 kv, 10 times Udc = -270 kv, Up1 = +450 kv, 10 times Subsequent DC test: Udc = - 420 kv, 23 h All the tests mentioned under the test programme above have been successfully performed and the results obtained related to the work ordered and the materials tested are satisfactory. Additional performance tests focused on Superimposed Lightning impulse withstand tests for a nominal voltage U 0 = 320 kv were carried out on the same cable system loop. Superimposed Lightning Impulse Withstand Test: Udc = +320 kv, Up1 = +665 kv, 10 times Udc = +320 kv, Up1 = - 375 kv, 10 times Udc = -320 kv, Up1 = +375 kv, 10 times Udc = -320 kv, Up1 = -665 kv, 10 times The cable system passed the tests successfully. Otherwise, a type test qualification for 2500 mm² copper cable systems including two moulded joints and composite outdoor terminations is currently in progress. The test is conducted according VSC protocol of Cigre recommendation for a nominal voltage U 0 = 320 kv see Figure. 13. Fig. 12: Type test set-up for 270 kv LCC cable systems The cable and relevant accessories (moulded field joint and terminations) was submitted to the complete qualification according LCC protocol in accordance with Cigre Technical brochure N 219 [7]. The type test was conducted for a nominal voltage of U 0 = 270 kv. It is underlined that a cable system qualified according to this recommendation for use with LCC is also qualified for use with VSC (Voltage Source Converter), but not the opposite. The Electrical Type Tests are performed as the following: Bending test according IEC 60840 Load Cycling (successful tests) 8 cycles at 1.85 x 270 = -500 kv, 8/16 h heating /cooling 8 cycles at 1.85 x 270 = +500 kv, 8/16 h heating / cooling 8 cycles with polarity reversal at 1.45 x 270 = 392 kv, 8/16 h heating /cooling Fig. 13: Type test set-up of the 320 kv cable systems CONCLUSION Space charge measurements have been investigated on plaques samples and three layers model cable. Space charge profiles in presence of gradient of temperature

shows a negative space charge accumulation at the external electrode. The electric field is enhanced inducing FEF>1. It seems that positive hetero-space charge disappears at the inner electrode. Model cables having 50 mm² copper conductors, with 4.5 mm of XLPE insulation thickness were produced and submitted to an extensive test protocol. Successful completion of full type test qualification has been performed on a 270 kv cable system, according LCC converter type, where polarity reversals were applied during heat cycling. The test was conducted according to CIGRE recommendations TB 219. It has been confirmed that the moulded joint withstand the electrical stress during reversal polarity. Indeed the space charges accumulation leads to electrical field enhancement at each cycle. The technique of rebuilding of the joint is based on the use of the same insulation as the cable. This confers to the moulded joint a great homogeneity, avoiding the problems of interface, harmful to a good behaviour under D.C. current. The cable system passed successfully and allows to a qualification for both technologies LCC and then for VSC converter type. A type test qualification for 2500 mm² copper cable systems including two moulded joints and composite outdoor terminations is currently in progress. The test is conducted according VSC protocol of Cigre recommendation for a nominal voltage U 0 = 320 kv. The knowledge gained during previous years combined with the results obtained gave us confidence about use of extruded cables for HVDC power transmission. A 400 kv system should not raise particular points with a mean electrical field of 20 kv/mm inside the main insulation. REFERENCES [1] A. Gustafsson, M. Jeroense and J. Karlstrand,2009 "Energy Efficiency with HVDC Technology", Power System Design Mag., pp.37-39. [2] X. Bourgeat, M.H. Luton 1995 Results of tests using continuous high voltage on low density polyethylene insulation, Jicable, pp. 694-696. [3] Y. Li, M. Yasuda and T. Takada, 1994 "Pulsed Electroacoustic Method for Measurement of Charge Accumulation in Solid Dielectrics", IEEE Trans. Dielectr. Electr. Insul., vol. 1, pp.188-195. [4] J.M. Alison, 1998 "A high field pulsed electro-acoustic apparatus for space charge and external circuit current measurement within solid insulators", Meas. Sci. Technol., vol. 9, pp. 1737-1750. [5] R.J. Fleming, M. Henriksen and J.T.Holboll, 2000 "The Influence of Electrodes and Conditioning on Space Charge Accumulation in XLPE", IEEE Trans. Dielectr. Electr. Insul, vol. 7, pp.561-571. [6] M. Fu, G. Chen, L.A. Dissado and J.C. Fothergill, 2008 "Space Charge Formation and its Modified Electric Field under Applied Voltage Reversal and Temperature Gradient in XLPE Cable", IEEE Trans.Dielectr. Electr. Insul., vol. 15, pp.851-860. [7] Cigre WG. 21-01, 2003 Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 250 kv, TB 219.