Fusion 120 Zoom. User Manual. Order code: EQLED068

Similar documents
Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Stratos Duo RGB. User Manual. Order code: EQLED371

ORDER CODE: EQLED65 USER MANUAL

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Batten (Order code: LEDJ95)

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

LED Spere Direct Control 30 ORDERCODE 41125

Stage Wash 7x 10W LED Moving Head (RGBW)

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

LED Pixel Track Pro ORDERCODE 42205

SquareLED - Aura Bar & Matrix Beam Light 100

ALO 060 DMX LED scanner

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Opti Tri White Par. User Instructions

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

EPAR QW. User Instructions

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Inno Color Beam 12. User Instructions

LED Thunder S-150 Code 1097

LED-BANK4 USER MANUAL. COLORbank 4

EPAR QA. User Instructions

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

Truss Light COB LED 30W

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

LED Spot 300W. Please read this user manual before your operation

MANUAL ENGLISH Core Club Ordercode: D2314

American DJ. User Instructions. Model: Mega Bar 50RGB

Stage Right Party Mini-Spider 3W LED Light (RGBW)

Spherion Tri LED General Information Unpacking: Introduction: Customer Support: Warning! Caution!

LED Pot 12 1W RGBW LED PAR. user manual

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

192 Channel DMX Controller

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

Owner Handbook Neptune Tumbler. Owner Handbook. Neptune Tumbler

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

LED-PAR200B USER MANUAL. COLORsplash 200B

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

DMX LED light effect with 4 lenses

MH-X50+ LED spot moving head. user manual

Colour Control48 Order Code: Control48

Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR. user manual

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

User Manual. Xstatic Pro, Inc Essex Street - Brooklyn, NY Version 1.2

Owner Handbook Saturn Quad Beam. Owner Handbook. Saturn Quad Beam

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

DMX Operator 192-channel lighting controller

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

American DJ. User Instructions. American DJ

VGAD-12 ORDERCODE

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

Stage Quad LED Bundle RGBW / RGBWW LED lighting set. user manual

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

USER MANUAL MHL-10W-7-RGBW MKII

User Instructions. Customer Support: American DJ provides a toll free customer support

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

DJ Lase BlueStar MK-II LED showlaser. user manual

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

ON-X. User Instructions

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

PRO PAR HEX 12. User Manual

Mini LED Pin Spot Light Model: PLS00571

Inno Pocket Z4. User Instructions

LED Flood Panel 150 LED floodlight. user manual

Outdoor Stage PAR 12 4 W Quad, 12 3 W UV IR LED PAR. user manual

Hex-color RGBAW+UV LED strip light

LED Pad Bar Compact ST RGB LED lighting set. user manual

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

Stage Right Party 10-Watt Mini Beam Moving Head LED Light

Jelly Par Profile System Introduction Unpacking: Introduction: Customer Support: Warning! Caution! User Instructions

Event Bar Q4. User Instructions

Venus W36 LED Moving Wash

JunoScan MK-II LED scanner. user manual

Order code: EQLA27 User manual

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions INNO POCKET SPOT TWINS

PicoSpot 20 LED moving head. user manual

VORTEX User Instructions

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Owner Handbook. Jupiter Blackhole. LED UV Flood

Transcription:

Fusion 120 Zoom User Manual Order code: EQLED068

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls. Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam. www.prolight.co.uk Fusion 120 Zoom User Manual 2

Product overview & technical specifications Fusion 120 Zoom The Equinox Fusion 120 Zoom is a 7 x 12W LED Moving Head with motorised zoom allowing for a variable beam angle from 6-45. The fixture is powered by 7 x 12W RGBW quad-colour LEDs. With its quick speed and built-in light shows, the fixture brings pure lighting stunning hues and colour washes to any venue. With a forward facing show this fixture is ideal for mobile DJs. 7 x 12W quad-colour LEDs Adjustable beam angle: 6-45 7541 Lux @ 2m (full on) Motorised zoom DMX channels: 8 or 16 selectable Auto, sound active and master/slave modes Pan: 540, Tilt: 190 0-100% dimming and variable strobe Supplied with hanging bracket 4 push button menu with LED display IEC power input 3-Pin XLR input/output Fan cooled 6 - Lux FULL ON R G B W 30200 4320 11600 1540 14500 7541 1080 2889 384 3621 3350 480 1280 171 1610 1890 270 723 96 905 1210 173 462 61.4 579 45 - Lux FULL ON R G B W 4480 660 1630 206 2210 1121 165 408 51.6 552 498 73.3 181 22.9 245 280 41.3 102 12.9 138 0m 1m 2m 3m 4m 5m 6 45 179 26.4 65.3 8.26 88.3 Specifications Power consumption Power supply Fuse Dimensions Weight Order codes 90W 100~240V, 50/60Hz F2A 250V 300 x 198 x 146mm 4kg EQLED068 198mm 146mm 300mm www.prolight.co.uk Fusion 120 Zoom User Manual 3

Technical specifications www.prolight.co.uk 03 MIC MENU DOWN UP ENTER DMX INPUT DMX OUTPUT FUSE: F2A POWER INPUT: 100-240V~50/60Hz 02 01 04 05 07 06 08 01 - LED display 02 - Function buttons 03 - Microphone 04 - DMX input socket 05 - DMX output socket 06 - IEC power input socket 07 - Fuse F2A 250V 08 - Fan In the box: 1 x fixture, 1 x power cable, 1 x hanging bracket, 1 x eye bolt & 1 x user manual www.prolight.co.uk Fusion 120 Zoom User Manual 4

Operating instructions A 0 0 1 A 0 0 1 A 5 1 2 DMX address setting C H N d 8 C h 1 6 C h Channel modes S P N d H I s P L o S P Pan/tilt speed setting S L N d N A s t S L 1 Master/slave mode S H N d S H 1 S H 4 Show modes S o u n o n o F F Sound mode on/off MENU P A n o n o F F Pan invert t I L o n o F F Tilt invert d I S P o n o F F Display invert N I C r F A C A d t r S t 0 0 0 1 0 0 o n o F F Motor reset Sound sensitivity Reset factory settings Home position setting d E L E P t F 0 0 0 1 2 0 0 0 0 1 2 0 0 0 0 1 2 0 www.prolight.co.uk Fusion 120 Zoom User Manual 5

Operating instructions DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX address mode, press the MENU button on the front of the unit to show A001 on the LED display. Now press the ENTER button and use the UP and DOWN buttons to set the required DMX address. Press the ENTER button to confirm the setting. DMX channel mode: To access the DMX channel mode, press the UP button on the front of the unit to show CHNd one of the 8 or 16 DMX channel modes. Press the ENTER button to confirm the setting. PLEASE NOTE: When the unit is receiving DMX the first red dot on the display will flash. 8 channel mode: Channel Value Function CH1 000-255 Pan adjustment 0-540 CH2 000-255 Tilt adjustment 0-190 CH3 000-255 Zoom adjustment CH4 000-255 Master dimmer (0-100%) CH5 000-255 Red (0-100%) CH6 000-255 Green (0-100%) CH7 000-255 Blue (0-100%) CH8 000-255 White (0-100%) www.prolight.co.uk Fusion 120 Zoom User Manual 6

Operating instructions 16 channel mode: Channel Value Function CH1 000-255 Pan adjustment 0-540 CH2 000-255 Pan fine adjustment CH3 000-255 Tilt adjustment 0-190 CH4 000-255 Tilt fine adjustment CH5 000-255 Pan/tilt speed CH6 000-255 Master dimmer (0-100%) 000-009 Blackout CH7 010-245 Strobe (slow-fast) 246-255 LED on CH8 000-255 Red (0-100%) CH9 000-255 Green (0-100%) CH10 000-255 Blue (0-100%) CH11 000-255 White (0-100%) CH12 000-255 Colour temperature 000-010 Blackout 011-020 R 021-030 G 031-040 B 041-050 W 051-060 R + G 061-070 G + B CH13 071-080 B + W 081-090 R + B 091-100 G + W 101-110 R + W 111-120 R + G + B 121-130 R + G + W 131-140 G + B + W 141-150 R + G + B + W 151-255 Colour change (slow-fast) CH14 000-010 No function 011-255 Fade (slow-fast) 000-020 No function 021-060 Program 1 061-100 Program 2 CH15 101-140 Program 3 141-180 Program 4 181-200 No function 201-225 Motor reset 226-255 No function CH16 000-255 Zoom adjustment www.prolight.co.uk Fusion 120 Zoom User Manual 7

Operating instructions Pan/tilt speed setting: To access the pan/tilt speed setting, press the UP button on the front of the unit to show SPNd between HISP (fast) or LoSP (slow). Press the ENTER button to confirm the setting. Master/slave mode: To set the master unit, press the UP button on the front of the master unit to show SLNd on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose Nast. Press the ENTER button to confirm the setting. Then select your desired program (sound active or one of the show modes). To set the other units in slave mode, press the UP button on the front of the unit to show SLNd either SL 1. Press the ENTER button to confirm the setting. The unit will now run in sequence with the master unit. Please ensure that all slave units are set to the same DMX channel mode as the master unit. Show mode: To access the show modes, press the UP button on the front of the unit to show ShNd between SH 1 ~ SH 4. Press the ENTER button to confirm the setting. SH 1 full show SH 2 slow show 1 SH 3 slow show 2 SH 4 forward facing show Sound/sound sensitivity: To turn the sound mode on or off, press the UP button on the front of the unit to show Soun on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between on or off. Press the ENTER button to confirm the setting. To adjust the sound sensitivity, press the UP button on the front of the unit to show NIC on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between 000 ~100. Value: 000-100 (000 = low, 100 = high) www.prolight.co.uk Fusion 120 Zoom User Manual 8

Operating instructions Pan invert setting: To access the pan invert setting, press the UP button on the front of the unit to show PAn between on or off. Press the ENTER button to confirm the setting. Tilt invert setting: To access the tilt invert setting, press the UP button on the front of the unit to show til between on or off. Press the ENTER button to confirm the setting. Display invert setting: To access the display invert setting, press the UP button on the front of the unit to show disp between on or off. Press the ENTER button to confirm the setting. Reset factory settings: To reset the units factory settings, press the UP button on the front of the unit to show rfac between on (reset) or off. Press the ENTER button to confirm the setting. Pan/Tilt/Zoom home position: To access the pan/tilt/focus home position setting, press the UP button on the front of the unit to show Ad t on the LED display. Now press the ENTER button and use the UP and DOWN buttons to select dele (default home position), P (pan home position), t (tilt home position) and F (Zoom home position). When on dele, press the ENTER button and the units home positions will be reset to the factory default (000). When on P, tor F, press the ENTER button and use the UP and DOWN buttons to adjust the value between 000 ~ 120. Press the ENTER button to confirm the setting. Motor reset: To reset the motors, press the UP button on the front of the unit to show rst on the LED display. Press the ENTER button to perform the reset. www.prolight.co.uk Fusion 120 Zoom User Manual 9

DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a start address from 1-512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107. DMX 512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Fusion 120 Zoom User Manual 10

DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89) Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion. 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Fusion 120 Zoom User Manual 11

WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Fusion 120 Zoom User Manual 12