IONIVAC Transmitter ITR 90

Similar documents
Vacuum measurement and control units

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

Bayard-Alpert Pirani Gauge

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Series 937B. Features & Benefits

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Single Point Flow Monitor SW118 SW119

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Intelligent Vacuum Metrology New VSR, VSP, VSM & VSH series

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 331i / DMP 333i LMP 331 i

VacTest. Vacuum Measurement Equipment The Best Choice to Monitor and Control Your Vacuum Process. Vacuum Measurement Technology by Busch

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Okta 1000, Roots pump without motor

TELEDYNE HASTINGS INSTRUMENTS

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PROPORTIONAL VALVES Sentronic plus

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Plug-in modules for total pressure gauges and controllers TPG 300 and IMG 300

CENTERLINE. Total pressure gauges

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Up to 85% higher Service Life due to efficient sealing method.

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

Agilent High Capacity RV Pumps & Roots Pumping Systems

Mechanical flow switch for On/Off control

Electromagnetic Block Valves Direct Acting

PENNINGVAC Transmitter PTR 90 N

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Operating manual incl. Declaration of conformity

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

D Issue G. Instruction Manual. Wide Range Gauge

High Vacuum Pumps TURBOVAC / TURBOVAC MAG DIP / LEYBOJET COOLVAC / COOLPOWER / COOLPAK

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Gurley Models LA18, LA20, LA25, High Resolution - Industrial Ruggedness

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Pressure transmitter COMPACT IO-Link,

SUPPLEMENTARY INFORMATION

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

MKS. Series 937B. Opera. RevC

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Solenoid valves VZWD, directly actuated

Solenoid valves VZWD, directly actuated

Gear Pump Units For single-line centralized lubrication systems

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

7 Lighting Technology

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

Dry Compressing Vacuum Pumps

SMALL OIL SEALED PUMPS

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

THE ULTIMATE DRY CHOICE

Liner Quattro AC XB RGBW

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Model KBF 115 Constant climate chambers with large temperature / humidity range

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Easy programming Robust. Flexible. FPS Flexible Position Sensor FPS. Field of Application. Advantages Your benefit. Options and special Information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

MKS Series 937B High Vacuum Multi-Sensor System Operation and Maintenance Manual

Selection matrix for electronic pressure switches

AC diagonal module Ø 200 mm

INSTRUMENT CATHODE-RAY TUBE

Linear flow controls VFC Linear flow controls with actuator IFC

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Gas Analysis. Microvision 2 STABILITY, ACCURACY AND SPEED THE RGA YOUR PROCESS CAN RELY ON

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

Model KT 115 Cooling incubators with thermoelectric cooling

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

Transcription:

IONIVAC Transmitter ITR 90 The ITR 90 is a optimized combination transmitter The combination of a hot cathode ionisation sensor according to Bayard-Alpert and a Pirani sensor permits vacuum pressure measurements of nonignitable gases and gas mixtures in the pressure range from 5 x 10-10 to 1000 mbar The ITR 90 can be ordered with integrated display or Profibus interface Advantages to the User - Continuous pressure measurements from 10-10 mbar to atmospheric pressure - High degree of reproducibility within the typical range for process pressures of 10-2 to 10-8 mbar - Controlled switching on and off sequencing through the integrated double Pirani optimized the service life of the yttrium coated iridium cathodes - Compact design - Enclosed, rugged electrode geometry in a rugged metal housing - Efficient degassing by electron bombardment - Simple fitting of the sensor - Extension for higher bake out temperatures during the measurements - One signal covering 13 decades - One flange joint for 13 decade - ITR 90 model with built-in display for stand-alone operation without additional display components - RS 232 C interface Typical Applications - Analytical - Evaporation and coating - Vacuum furnaces - General purpose pressure measurements in the fine and high vacuum ranges 46 Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling leybold

Sensor The sensor of the ITR 90 contains a dual filament Pirani system as well as a Bayard-Alpert measurement system When using the bake out extension, measurements will be possible also at flange temperatures up to 150 C 10 Volt 8 7 6 5 4 3 2 1 0 U(a) Equation p = 10 (u-7.75)/ 0.75 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 10 0 10 Pressure mbar 1000 Characteristic of the ITR 90 58 (2.28") 67 (2.64") 153 (6") ~105 48 (1.89") 42 (1.65") DN 40 CF-R DN 25 ISO-KF ø40 in mm Dimensional drawing for the ITR 90; dimensions in mm, in brackets ( ) are in inch (Image with integrated display; Profibus interface differing) Dimensional drawing for the bake out extension leybold Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling 47

Technical Data IONIVAC-Transmitter Measurement range mbar (Torr) ITR 90 5 x 10-10 to 1000 (3 75 x 10-10 to 750) Measurement uncertainty, 10-1 1000 mbar Measurement uncertainty, 10-8 10-2 mbar Reproducibility, 10-8 10-2 mbar Principles of measurement Degas Supply voltage 15% of the meas. value 15% of the meas value 5% of the meas value Hot cathode ionization according to Bayard-Alpert combined with thermal conductivity according to Pirani Electron bombardment 3 minutes, max 20 to 28 V DC, typ 24 V DC16 Power consumption, max. W 16 Storage / nominal temperature range C Protection class -20 to +70 / 0 to +50 IP 30 Weight, approx. ITR 90, DN 25 ISO-KF ITR 90, DN 40 CF Sensor kg (lbs) kg (lbs) 0 285 (0 64) 0 550 (1 24) Fully sealed, exchangeable Degassing temperature, max. C Dead volume, approx. cm 3 Materials in contact with the medium 150 1) 24 at DN 25 ISO-KF 34 at DN 40 CF Cu, W, Glass, NiFe, Mo, Stainless steel, Aluminum, Iridium, Yttrium, NiCr Overpressure rating (abs.) Signal output (R a 10 kω) Measurement signal Error signal Interface (standard / optional) Electrical connection Cable length, max. bar m 2 0 10 V, 0 774 10 V, 0 75 V pro decade < 0,5 V RS 232 C / ProfiBus 15-way Sub-D male connector / pin contacts 100 / 30 at RS 232 C 1) Flange temperature when using the bake out extension 48 Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling leybold

Ordering Information IONIVAC-Transmitter ITR 90 without Display Part No. with Display Part No. ITR 90, DN 25 ISO-KF ITR 90, DN 25 ISO-KF, Profibus interface ITR 90, DN 40 CF-R, rotatable CF flange ITR 90, DN 40 CF-R, rotatable CF flange Profibus interface 120 90 120 91 230 030 120 92 120 94 230 031 Power supply for IONIVAC transmitter 100 240 V AC / 24 V DC incl. 5 m connection cable and 5 m RS 232 C cable Bake out extension (100 mm, approx.) Baffle, DN 25 ISO-KF, with Installation baffle for CF/ISO-KF variant Replacement sensor IE 90, DN 25 ISO-KF 1) IE 90, DN 40 CF-R 1) 121 06 121 06 127 06 127 06 121 07 121 07 E 121 02 E 121 02 E 121 03 E 121 03 Calibration Connection cable see chapter Miscellaneous, para Leybold Calibration Service see chapter Products, para Connection Cable for Active Sensors see chapter Miscellaneous, para Leybold Calibration Service see chapter Products, para Connection Cable for Active Sensors 1) Including hex socket screw key leybold Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling 49

IONIVAC Transmitter ITR 200 S The ITR 200 S is an optimized dual cathode combination transmitter on the basis of the well proven ITR 90 The combination of a hot cathode ionization sensor according to Bayard-Alpert and a Pirani sensor allows vacuum pressure measurements of non-ignitable gases and gas mixtures in the pressure range from 5 x 10-10 to 1000 mbar Upon request, the pressure can be displayed on an integrated display Advantages to the User - Service life increase and increased operational reliability through integration of a second hot cathode - Full coverage of the pressure range from 5 x 10-10 mbar to atmospheric pressure - High repeatability within the typical process pressure range of 10-2 to 10-8 mbar - Controlled switching on and switching off through the integrated dual Pirani optimized the service life of the yttrium-coated iridium cathodes - Compact design - Enclosed, stable electrode geometry in rugged metal casing - Efficient degassing through electron bombardment - Simple to install - ITR 200 S version with built-in display allows for stand-alone operation without the necessity for additional displays - RS 232 C interface Typical Applications - Analytical engineering - Sputtering and coating technology - Vacuum furnaces - Multipurpose pressure measurement in the medium and high vacuum range Options Upon request, the ITR 200 S can be supplied with an integrated display or a Profibus interface Sensor The sensor of the ITR 200 S includes besides the Pirani system a dual cathode measurement system according to Bayard-Alpert If one of the hot cathodes should burn out during operation, then the second cathode is automatically switched on Moreover, each sensor contains a memory chip with the relevant system data Thus after having exchanged a sensor, an automatic alignment is performed between sensor and operating electronics (plug and play) 50 Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling leybold

58 (2.28") 67 (2.64") Top View 153 (6") 48 (1.89") 42 (1.65") DN 40 CF-R DN 25 ISO-KF Dimensional drawing for the ITR 200 S; dimensions in mm, in brackets ( ) are in inch (Image with integrated display; Profibus interface differing) 10 Volt 8 7 6 5 4 3 2 1 0 U(a) Equation p = 10 (u-7.75)/ 0.75 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 10 0 10 Pressure mbar 1000 Characteristic of the ITR 200 S leybold Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling 51

Technical Data IONIVAC-Transmitter Measurement range mbar (Torr) ITR 200 S 5 x 10-10 to 1000 (3 75 x 10-10 to 750) Measurement uncertainty, 10-1 1000 mbar Measurement uncertainty, 10-8 10-2 mbar Reproducibility, 10-8 10-2 mbar Principles of measurement Degas Supply voltage 15% of the meas. value 15% of the meas value 5% of the meas value Hot cathode ionization according to Bayard-Alpert combined with thermal conductivity according to Pirani Electron bombardment 3 minutes, max 20 to 28 V DC, typ 24 V DC Power consumption, max. W 20 Storage / nominal temperature range C Protection class -20 to +70 / 0 to +50 IP 30 Weight, approx. ITR 200 S, DN 25 ISO-KF ITR 200 S, DN 40 CF Sensor kg (lbs) kg (lbs) 0 50 (1 10) 0 75 (1 65) Fully sealed, exchangeable Degassing temperature, max. C Dead volume, approx. cm 3 Materials in contact with the medium 150 1) 24 at DN 25 ISO-KF 34 at DN 40 CF Cu, W, Glass, NiFe, Mo, Stainless steel, Iridium, Yttrium, NiCr Overpressure rating (abs.) Signal output (R a 10 kω) Measurement signal Error signal Interface (standard / optional) Switching function Standard Profibus Electrical connection Cable length, max. bar m 2 0 10 V, 0 774 10 V, 0 75 V pro decade < 0,5 V RS 232 C / Profibus 1 normally open contact 2 normally open contacts 15-way Sub-D male connector / pin contacts 100 / 30 at RS 232 C 1) Flange temperature when using the bake out extension 52 Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling leybold

Ordering Information IONIVAC-Transmitter ITR 200 S without Display with Display Part No. Kat.-Nr ITR 200 S, DN 25 ISO-KF 1 switching function ITR 200 SP, DN 25 ISO-KF, Profibus interface, 2 switching functions ITR 200 S, DN 40 CF-R, rotatable CF flange 1 switching function ITR 200 SP, DN 40 CF-R, rotatable CF flange Profibus interface, 2 switching functions Options Power supply for IONIVAC transmitter 100 240 V AC / 24 V DC incl. 5 m connection cable and 5 m RS 232 C cable Baffle, DN 25 ISO-KF, with Installation baffle for CF/ISO-KF variant Replacement sensor IE 200, DN 25 ISO-KF 2) IE 200, DN 40 CF-R 2) IE 200 SL 1), DN 40 CF-R 2) 230 250 230 251 230 252 230 254 230 255 230 256 121 06 121 06 121 07 121 07 240 020 240 020 240 021 240 021 240 022 Calibration Connection cable see chapter Miscellaneous, para Leybold Calibration Service see chapter Products, para Connection Cable for Active Sensors see chapter Miscellaneous, para Leybold Calibration Service see chapter Products, para Connection Cable for Active Sensors 1) SL = long version (bake out version) 2) Including hex socket screw key leybold Leybold Full Line Catalog 2018 - Vacuum Measuring, Controlling 53