Case study: how to create a 3D potential scan Nyquist plot?

Similar documents
Analyzing and Saving a Signal

2 Select the magic wand tool (M) in the toolbox. 3 Click the sky to select that area. Add to the. 4 Click the Quick Mask Mode button(q) in

INTRODUCTION TO ENDNOTE

Data Acquisition Using LabVIEW

APPLICATION NOTE RAPID ELECTROCHEMICAL ASSESSMENT OF PAINT

Processing data with Mestrelab Mnova

Topic: Instructional David G. Thomas December 23, 2015

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

Quick Start manual for Nova

HD-SDI Express User Training. J.Egri 4/09 1

MICROSOFT WORD FEATURES FOR ARTS POSTGRADUATES

Contents DIVISION OF LIBRARY SERVICES. EndNote X7 Mac User Manual Part 2

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

Applying effects including adjusting volume and fade in and out

EndNote Online. Getting Started Guide (Windows)

Synergy SIS Attendance Administrator Guide

How to find out information about the report

Dektak Step by Step Instructions:

Quick Start Guide Building and Scheduling a Show

WaveDriver 20 Potentiostat/Galvanostat System

ECT 224: Digital Computer Fundamentals Digital Circuit Simulation & Timing Analysis

MUSC 1331 Lab 1 (Sunday Class) Basic Operations and Editing in Performer. Quantization in Performer

Import and quantification of a micro titer plate image

Word Tutorial 2: Editing and Formatting a Document

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

How-to Setup Motion Detection on a Dahua DVR/NVR

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

PYROPTIX TM IMAGE PROCESSING SOFTWARE

My XDS Receiver- Affiliate Scheduler

Keeping a Bibliography using EndNote

Using EndNote X6 to Manage Bibliographies

WaveNow USB Potentiostat / Galvanostat

Exercise #1: Create and Revise a Smart Group

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

PicoScope for Windows user guide Chapter 1: Overview Chapter 2: Views Chapter 3: How To.. Chapter 4: Menus Chapter 5: Dialogs

BullCharts BullScan Manager a Tutorial

How to Insert Page Numbers in WORD

Physics 105. Spring Handbook of Instructions. M.J. Madsen Wabash College, Crawfordsville, Indiana

Agilent Parallel Bit Error Ratio Tester. System Setup Examples

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Test Records. Scanning Test Records. This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information.

Risk Management. Enhancing Referral Workflow. Karee Burns, RN, BSN. TJ McGreevy. Midas+ Solutions Consultant. Midas+ Product Management Specialist

Remote Application Update for the RCM33xx

ETAP PowerStation 4.0

MODFLOW - Grid Approach

LEDBlinky Animation Editor Version 6.5 Created by Arzoo. Help Document

Software manual. ChipScan-Scanner 3.0

Update Records. Scanning Update Records

Using EndNote X7 to Manage Bibliographies on a Mac!

TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS. 1 INTRODUCTION 1.1 Foreword 1.2 Credits 1.3 What Is Perfect Drums Player?

EndNote Essentials. EndNote Overview PC. KUMC Dykes Library

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes

Model 7600 HD/SD Embedder/ Disembedder Data Pack

Allegro PCB SI SigXplorer L Series Tutorial. Product Version 16.0 June 2007

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

With Export all setting information (preferences, user setttings) can be exported into a text file.

Grid Interactive Advanced Features Self-Supply Mode

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to:

USING ENDNOTE X4: ADVANCED SKILLS

The Time Series Forecasting System Charles Hallahan, Economic Research Service/USDA, Washington, DC

Using the Agilent for Single Crystal Work

Instructions for Carrying Out Generic Spectral Analysis Measurements with the HP-3562A Dynamic Signal Analyzer

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

The MPC X & MPC Live Bible 1

UltraPioneerAVR3 HSPI User s Guide A HomeSeer HS3 plug-in to enable control of Pioneer A/V Receivers that support the IP & RS232 control system.

Performing Signal Integrity Analyses. Signal Integrity Overview. Modified by Phil Loughhead on 16-Nov-2015

ViewCommander- NVR Version 3. User s Guide

DIGITAL MEASURES BIBTEX AND PUBMED IMPORT- MANUAL

2. Get a free Adobe ID at adobe.com (Click Sign In (top right corner), click Get an Adobe ID, fill in the form and click Sign Up)

Select source Click the Bio Settings button to modify device settings. Select Fingers Use Ctrl+Left mouse button to select multiple fingers to scan.

CFlow User Guide. Science is hard. Flow cytometry should be easy.

User Guide. c Tightrope Media Systems Applies to Cablecast Build 1055

potentiostat/galvanostat

Chapter 5 Printing with Calc

Auro 11.1 update for ICMP. Installation manual

Go! Guide: The Notes Tab in the EHR

DSP Laboratory: Analog to Digital and Digital to Analog Conversion *

Blueline, Linefree, Accuracy Ratio, & Moving Absolute Mean Ratio Charts

UNC. JlJ1 THESIS AND DISSERTATION SUBMISSION CHECKLIST

Chapter 4 Working with Bands

Preparing for remote data collection at NE-CAT

Neurite-J 1.1. ImageJ plug-in. User manual. October, 2014

EndNote X6 with Word 2007

Introductions o Instructor introduction o Attendee introductions Why are you here? What do you hope to learn? Do you have any special needs?

De-embedding Gigaprobes Using Time Domain Gating with the LeCroy SPARQ

User Guide & Reference Manual

InPlace User Guide for Faculty of Arts, Education and Social Sciences Staff

Using Endnote advanced features

Scanning Entry Records Entry Records 1) Tools Menu Scanning Wizard 2) Using Scanner Hardware Contro 3) Entry Front Side 1

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

Getting started with

XRD-DSC Sample Alignment (BB) Part

GET STARTED WITH ACADEMIC WRITER

TABLE OF CONTENTS. 03 Overview. 04 Working Environment. 06 User Interface Introduction 08 FAQ. 41 Glossary and Abbreviations.

User Manual K.M.E. Dante Module

TELEVISION. Star Plans. Interactive Guide and DVR (Digital Video Recorder) Manual ARVIG arvig.net

Editing Your Reading List

SignalTap: An In-System Logic Analyzer

Transcription:

NOVA Technical Note 11 Case study: how to create a 3D potential scan Nyquist plot? 1 3D plotting in NOVA Advanced 3D plotting In NOVA, it is possible to create 2D or 3D plots. To create a 3D plot, three signals must be selected from the available electrochemical signals for the X, Y and Z axis. In a typical impedance measurement performed with NOVA, the following signals are available for plotting (see Figure 1): frequency, Z, -Z, Z, Phase and time. Figure 1 The electrochemical signals available in a typical FRA measurement in NOVA Any of the available signals can be used to create a 3D plot, like a 3D Nyquist plot, for example, using the frequency signal on the Z axis (see Figure 2). Figure 2 A possible 3D plot created in NOVA 1 Page

NOVA Technical note 11 Note The frequency is plotted on the Z axis using a logarithmic scaling. 2 Restrictions There are two important restrictions related to data plotting in NOVA: 1. Only electrochemical signals located in the same data grid can be plotted on a 2D or 3D plot. It is not possible to create a plot using a signal from one experiment for the X axis and a signal from another experiment for the Y axis, even if both experiments are part of the same data set. 2. The signals used on the X, Y and Z axis must have the same length. 3 Adding the DC data to the FRA data grid Taking the two restrictions mentioned in the previous section into account, this technical note will illustrate how to add the DC components in the same data grid as the other impedance data points recorded during a FRA measurement. Using this strategy, each impedance data point will have matching DC potential and DC current values in the data grid. The Autolab FRA potential scan procedure, available in the Autolab group in the procedure editor will be used as a template. The objective of this note is the creation of the 3D potential scan FRA Nyquist plot, similar to the one shown in Figure 3. 2 Page

NOVA Technical Note 11 Figure 3 A 3D potential scan FRA Nyquist plot (experimental data obtained with the Autolab dummy cell) 3.1 Loading the Potential scan FRA procedure Load the Potential scan FRA procedure from the Autolab group of procedures into the procedure editor. Figure 4 shows the overview of the Potential scan FRA procedure. In this procedure, a full frequency scan is performed at twelve different potential values from 1.2 V to 0 V. A step of 100 mv in used in between each measurement. The potential values used in this measurement are defined in the Repeat for each value command. 3 Page

NOVA Technical note 11 Figure 4 Overview of the Potential scan FRA procedure The FRA measurement potentiostatic command is used to perform the frequency scan embedded into the repeat loop. The frequency scan itself is preceded by a Set potential command that defines the DC conditions for the measurement. The Set potential command is linked to the Repeat for each value command (see Figure 4). 3.2 Adding the DC signals to the FRA data In order to add the Potential (DC) and the Current (DC) signals to the FRA data, these signals must first be added to the FRA measurement, for each individual frequency. Open the FRA editor by clicking the button (see Figure 5). 4 Page

NOVA Technical Note 11 Figure 5 Opening the FRA editor In the FRA editor, make sure that the Sample DC property in the Sampler section is set to yes (see Figure 6). 5 Page

NOVA Technical note 11 Figure 6 The DC component is sampled through the FRA editor Note Please refer to the Impedance measurements tutorial, available from the Help menu in NOVA, for a complete description of the signals provided in the FRA sampler. Note The Sample DC option is already set to On in the default Autolab FRA potential scan procedure. Click OK to close the FRA editor window. The procedure editor will be updated and the additional signals will be shown in blue, in the FRA single frequency command (see Figure 8). 6 Page

NOVA Technical Note 11 Figure 7 The additional signals are displayed in blue Note Since the Sample DC checkbox is already checked in the default Autolab FRA potential scan procedure, the Potential (DC) and Current (DC) signals are already available in this procedure (see previous screenshots). When this measurement is performed, the Potential (DC) and the Current (DC) will be logged for each impedance point, thus satisfying the second condition specified at the beginning of this technical note. 3.3 Merging the additional data points to the data grid In order to satisfy the first condition defined at the very beginning of this document, the values of the Potential (DC) and Current (DC) must be added to the data grid containing all the recorded impedance data. 7 Page

NOVA Technical note 11 In order to do this, click the button located next to the Build signal command in the procedure editor, in order to edit the list of signals to extract from the measurement (see Figure 9). Figure 8 Click the button to open the Build signal editor The Build signal editor window will be displayed. The frame on the right hand side shows the list of default impedance values to gather in a single table (see Figure 10). 8 Page

NOVA Technical Note 11 Figure 9 The Build signal window shows the signals to extract from the measurement Expand the Measurement impedance group in the frame on the left hand side and repeat this for the FRA signal frequency group. The Potential (DC) and Current (DC) signals will be shown in the list of signals available (see Figure 11). Figure 10 The additional signals are located in the FRA single frequency group Click the Potential (DC) signal in the frame on the left hand side of the editor and, while holding the mouse button, drag it into the frame on the right hand side. Drop this item just below the FRA single frequency item, as shown in Figure 12. 9 Page

NOVA Technical note 11 Figure 11 Adding the Potential (DC) signal to the list of signals The Potential (DC) will be added to the list of signals collected by the Build signal command (see Figure 13). 10 Page

NOVA Technical Note 11 Figure 12 The Potential (DC) is added to the list of signals Repeat this for the Current (DC), dropping this signal just below the FRA single frequency item in the frame on the right hand side of the Build signal window (see Figure 14). Figure 13 Adding the Current (DC) to the list of signals 11 Page

NOVA Technical note 11 The Current (DC) will be added to the list of signals collected by the Build signal command (see Figure 15). Figure 14 The Current (DC) is added to the list of signals Click OK to validate the changes to the Build signal command. The procedure editor will be updated (see Figure 16). Figure 15 The Potential (DC) and Current (DC) are added to the list of signals located below the FRA measurement potentiostatic command 3.4 Creating the extra plot In order to build an overlay of the 3D Nyquist plots at the end of the measurement, an additional Nyquist plot can be added to the FRA measurement potentiostatic command. 12 Page

NOVA Technical Note 11 From the Plots general group of commands, locate the Custom plot command and add it to the procedure editor, dropping it on the FRA measurement potentiostatic command (see Figure 17). Figure 16 Adding a Custom plot to the FRA measurement potentiostatic command Rename the plot to Nyquist plot 3D, define the X and Y signals to Z and Z, respectively. Link the Z signal to the WE(1).Potential. Change the Show during measurement property from Yes to No (see Figure 18). Figure 17 Defining the plot settings for the Nyquist plot 3D 13 Page

NOVA Technical note 11 Note The plot options of the additional plot can be adjusted as necessary. Note It is not possible to plot the data in 3D in real time. 4 Run the measurement on dummy cell (c) The procedure is now ready. It is possible to save this modified procedure and run it on the Autolab dummy cell (c). This measurement will take roughly 20 minutes. Alternatively, the NOVA technical note 11 - FRA potential scan [NOVA 1.10].nox procedure, provided with this technical note, can be used. More frequencies are included in this procedure. Connect the Autolab dummy cell (c) and press the start button. This experiment takes about 1 ½ hours to complete. When the measurement is complete, an overlay of all the Nyquist 3D plots can be created, resulting in a plot similar to the one shown in Figure 3. 14 Page