Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Industrial Diode Laser (IDL) System IDL Series

Light Delivery Systems for Optogenetics

STAR-07 RGB MULTI-COLOR INDUSTRIAL PATTERN PROJECTION

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

CBF500 High resolution Streak camera

HP 70950B OPTICAL SPECTRUM ANALYZER

DT3130 Series for Machine Vision

In-process inspection: Inspector technology and concept

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

IMPAC Infrared Thermometers

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

GFT Channel Digital Delay Generator

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

LD OEM/LD PDS/LD PeCo

STAR-07. Industrial Pattern Projection. System Architecture. System Control

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

SPATIAL LIGHT MODULATORS

OPTICAL POWER METER WITH SMART DETECTOR HEAD

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

InGaAs multichannel detector head

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

Fiber-coupled light sources

Create an Industrial 3D Machine Vision System using DLP Technology

General Specifications

ADVANCED OPTICAL FIBER SOLUTIONS

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

XC-77 (EIA), XC-77CE (CCIR)

Agilent 81600B Tunable Laser Source Family

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

OTS-300 Express Series Power Meters/Sources and Testers

Digital SWIR Scanning Laser Doppler Vibrometer

MAP Optical Power Meter Module (mopm-b1)

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

Light Source. Specification & User Manual

Advanced Test Equipment Rentals ATEC (2832)

CMA4000i Optical Test System

013-RD

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

25W 9xxnm Uncooled Multimode Laser Diode Module

Advanced Test Equipment Rentals ATEC (2832)

Measurement of Microdisplays at NPL

Scanning System S-2100

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

ivw-ud322 / ivw-ud322f

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

Standard Operating Procedure of nanoir2-s

Steady-Lite Model 13plus Variable Intensity Fluorescent Illuminator High Frequency (85 khz) - Lite Mite Series

Lensed Fibers & Tapered Ends Description:

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Video Digital Optical Converter

Optical Perfection. HIGHYAG Beam Delivery Products

Click to Print This Page. 9,500 ANSI / 10,500 ISO Lumens Contrast Ratio: 10,000:1 (Dynamic Black) 1,000:1 native Part Number:

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

Digital SWIR Scanning Laser Doppler Vibrometer

High performance optical blending solutions

Mahdad Manavi LOTS Technology, Inc.

More Precision. confocaldt // Confocal chromatic measuring system

Multicolor Scan Laser Photocoagulator MC-500 Vixi

Optical Engine Reference Design for DLP3010 Digital Micromirror Device

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

MTS/T-BERD 8000 Platform

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

4-channel HDMI Network Extender

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Driver circuit for CCD linear image sensor

More Precision. confocaldt // Confocal chromatic measuring system

PSM-003. Micro Polarization Controller/Scrambler. User Guide

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

Altman Lighting AP-150 RGBW Par Specification

Prisma Optical Networks Ancillary Modules

E4416A EPM-P Series Single Channel Power Meter

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

Transcription:

Active Illumination Features and Benefits Unlimited flexibility in shape, size and complexity of illumination mask Simultaneous illumination of multiple regions of interest Precise illumination of areas of interest that protects target specimen and fluorophore Zero delta acquisition time for true digital excitation/illumination Longest lifetime and lowest maintenance with rugged semiconductor device DMD Technology The core of Mosaic is the Digital Micromirror Device (DMD), a high speed and highly efficient semiconductor-based light switch array of hundreds of thousands hinge-mounted, addressable, tiltable, microscopic mirrors. When a DMD chip is coordinated with a digital video or graphic signal, a light source, and beam delivery optics, its mirrors reflect a digital image of the illumination mask onto the sample. Mosaic Real Time Parallel Illumination of Multiple Regions Mosaic is a patented instrument platform built around MEMS Digital Mirror Devices (DMD). Mosaic exploits DMD in a proprietary programmable platform, integrated with scientific light sources including lasers, LEDs and arc lamps, and operates from 360 to 800 nm. It is offered with a range of high performance microscope adapter optics and can be integrated with CLSM, spinning disk and wide field imaging modalities. High speed frame switching (60 Hz) makes Mosaic suitable for many dynamic applications including bleaching, uncaging, photo-switching, optogenetics and constrained illumination. Variable intensity distributions can be achieved by rapid gating of mirror patterns. Specifications Summary Transmission Extinction ratio > 1000:1 Minimum resolvable spot Optical pixel rise / fall time < 1 µs Minimum optical pulse width Maximum frame repetition rate 360 nm to 800 nm Diffraction limited with 60x or 100x objective 75 µs external trigger 100 µs internal trigger 600 frames / sec Certification CDRH IIIb (if fitted with a laser source) Page 1 of 9

Hardware Specifications Optical Model Mosaic Mosaic Transmission Intensity stability 360 nm to 800 nm Absolute Extinction ratio > 1000:1 Minimum resolvable spot Fields of view Illumination port clear aperture Diffraction limited with 100x objective 7206 = 5.4 x 4.1 mm 7201 = 15.2 x 11.3 mm Ø 34 mm For flat field illumination port options, please see table at bottom of this section Illumination Source Options DMD illumination ports 1 or 2 on left hand side* 1 or 2 on left hand side, 1 or 2 on right hand side* Incoherent sources High pressure mercury lamp (100 W - 300W) DG4 Andor AMH-200 Other light sources on request CW laser 405 nm diode 488 nm Argon 514 nm Argon Other on request * 7201 allows only 1 port, 7206 allows 2 ports Additional illumination source options available on request Illumination Port Options Dichroic beamsplitter Single pass, specify wavelength Multi-pass, specify wavelength Beamsplitter 360 nm to 700 nm, R = 100, 70, 50 or 30% Excitation filter * Laser safety filter, interlocks 480 nm / 20 nm (GFP), 470 nm / 40 nm (FITC) - 38 mm Other filters on request - 25 mm with adapter Laser specific Optional * Additional excitation filter options available on request Flat field EPI illumination ports Adapter Leica DMI series Nikon TE2000 Nikon Ti series Nikon Universal Olympus IX series Part Number MM-7310-DMI-FFEP-X* MM-7310-TE2K-FFEP-X* MM-7310-TI-FFEP-X* MM-7310-NFS-FFEP-X* MM-7310-IX70-FFEP-X* Adapter Zeiss Axiovert 200 Zeiss Axio Examiner D1 Zeiss Axio Imager M1 Zeiss Axio Observer C-mount video port Part Number MM-7310-ZSAV-FFEP-X* MM-7310-D1-FFEP-X* MM-7310-IMG-FFEP-X* MM-7310-OBS-FFEP-X* On request *For 7201, X = 1 *For 7206, X = 2 INTEROPERABILITY Compatible with microscopes platforms - point & slit scan confocal, spinning disk confocal & widefield. Custom OEM systems available for High Content Screening and other fluorescence based imaging instrumentation. Compatible with control and acquisition software from market leading microscope manufacturers including Carl Zeiss, Leica and Olympus. Wavelength modularity - add lasers and filters cost effectively. Page 2 of 9

Software Specifications The Mosaic system includes software that controls calibration and enables the user to graphically or numerically define and edit the shape and characteristics of the illumination at the target. Release MicroPoint Mosaic Version 1.1 Drivers Calibration Operating systems File Functions Drawing Editor Shapes Drawn Shape Characteristics Controls Options PLX 9054 API version 4.1 for Mosaic.exe UI PLX 9054 API version 6 for SDK Scale & Offset corrections for X & Y 8 user-defined descriptions Windows 2000, XP Import (*.dxf, *.bmp, *.msk); Save *.msk Line, Paintbrush, Rectangle, Oval, Freehand polyshape Line width, paintbrush size, Alpha blended color and opacity of defined regions, Color palette Click and drag shapes and edges, cut, copy, paste, delete shape, Group, ungroup shapes Engage mask pattern, Go dark (global), Stop, Snapshot video Continuous update from drawing editor, Configure video subsystem, Exposure time & trigger selection Video mode & time selection, On/Off, Adjust laser outline highlight The angular alignment of either the CW laser or lamp illumination is factory set. The spatial alignment is controlled via the software calibration routine. The focus in the z direction is fixed at installation or OEM integration. Beam shaping is then controlled with the spatial light modulating DMD. Define region of interest and excitation energy at the target in image acquisition software Simultaneously excite and acquire image with zero delta time Software Compatibility - Life Science Applications Mosaic systems are compatible with a wide range of life science imaging software as indicated in the table below. Andor iq Version 2.0 MicroPoint Laser Galvo Version 1.0 MDC MetaMorph Ver 7.1 and above (32-bit) MDC MetaMorph Ver 7.74 and above (64-bit) Nikon NIS Elements 3.0 SP4 Build 505 Software Development Kits (SDK) Live cell multi-dimensional imaging with flexible control of MicroPoint Image-based targeting, control & calibration Fully integrated MicroPoint support with powerful imaging capabilities Fully integrated MicroPoint support with powerful imaging capabilities Multi-dimensional imaging with simple/fast control of MicroPoint SDKs are available for OEM to develop software to control integrated MicroPoint systems Page 3 of 9

Components The main components of Mosaic are shown below: Beamsplitter/ dichroic plugs Flange for EPI source DMD array Electronic interface Laser fiber input Laser zoom collimator Flange for optional second light source Page 4 of 9

Ordering your Mosaic system Prior to commencing the order process, please advise your customer representative of your application requirements. Please also refer to the flow charts on the next 2 pages. Step 1. Confirm your Microscope make and model Leica, Nikon, Olympus, Zeiss Step 2. The following field of illumination options are available: 7201 = 15.2 x 11.3 mm and 7206 = 5.4 x 4.1 mm Step 1. In order to allow us to select the correct model for your requirements please advise your customer representative of the make, model (and any accessories fitted) of the microscope being used. Step 2. Please select the field of illumination required. Step 3a. Select the primary left sided DMD light source. For the 7206 option only, a secondary left side light source can also be selected at this point. Step 3b. For Mosaic systems only a primary right sided light source can also be selected. For the 7206 option only, a secondary right side light source can also be selected at this point. Step 4. Select the type of EPI light source require. Step 5. Step 3a. The following DMD light sources / filter sets for the left side port of Mosaic are available: Diode laser, XLED1, Other laser, Andor AMH, DG4, Hg The following left sided excitation filters are available: GFP filter in holder (480/20), FITC (470/40),Blank filter holder, Others on request Secondary left sided DMD source, select one or more of the following beamsplitters: 30 EPI, 50 EPI,70 EPI, 100% EPI Plug, 0% EPI (Blank) Plug. A range of dichroic mirrors is available on request. Step 3b. For Mosaic systems only, additional DMD light sources / filter sets for the right side port: Diode laser, XLED1, Other laser, Andor AMH, DG4, Hg The following right sided excitation filters are available: GFP filter in holder (480/20), FITC (470/40),Blank filter holder, Others on request Secondary right sided DMD source, select one or more of the following beamsplitters: 30 EPI, 50 EPI, 70 EPI, 100% EPI Plug, 0% EPI (Blank) Plug. A range of dichroic mirrors is available on request. Step 4. The following EPI light sources are available: Andor AMH, XLED1, DG4, Microscope specific Hg lamp, MicroPoint, other Step 5. Optional EPI Excitation filters are also available: GFP filter in holder (480/20), FITC (470/40). Others on request Step 6. The following EPI-Mosaic beamsplitters are available: 30 EPI, 50 EPI, 70 EPI, 100% EPI plug, 0% EPI (Blank) Plug Choose one or more optional EPI excitation filters. Step 6. Choose one or more EPI / Mosaic beamsplitters. Page 5 of 9

Configuring Mosaic The Mosaic can be tailored to suit your needs, there are a number of options including mosaic illumination sources, EPI illumination sources, Active mirror array magnification and filtering. Microscope Olympus Nikon Zeiss Leica Microscope Options Mosaic Illumination Input with & BNC Cable Laser Delivery / safety filters Three Channel TTL synchronization modules with delay and duration inputs/outputs Field of Illumination 7201 7206 15.2 x 11.3mm 5.4 x 4.1mm Mosaic Input Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Input Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder Secondary Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug EPI Light Source AMH DG4 XLED1 Hg MicroPoint Other 5 Optional EPI Excitation Filters (Choose one or more if required) FITC exciter filter GFP exciter filter Rhodamine exciter filter Blank filter holder EPI/ Mosaic Beamsplitter 30 EPI:70 Laser Beamsplitter Plug 100% EPI Plug 50 EPI:50 Laser Beamsplitter Plug 0% EPI (Blank) Plug 70 EPI:30 Laser Beamsplitter Plug Multiplex with MicroPoint For applications requiring both ablation and zero delta time fluorescence excitation of multiple regions with complex geometries, the Mosaic s EPI Illumination port can be fitted with a Micropoint system and filtering. Page 6 of 9

Configuring Mosaic (Complementary Multicolour Illumination) Some photosensitive proteins can be activated with one wavelength of light and deactivated or silenced with another. This property is exploited in the Mosaic e.g. to sharpen control over protein localization. A second light source is coupled into the DMD at a complementary angle to the primary. In this configuration pixels NOT selected for activation define an inverse mask which can be illuminated to silence molecules outside of the activation region(s) or those diffusing away. Microscope Olympus Nikon Zeiss Leica Microscope Options Mosaic Illumination Input with & BNC Cable Laser Delivery / safety filters Three Channel TTL synchronization modules with delay and duration inputs/outputs Field of Illumination 7206 5.4 x 4.1mm Primary Left Sided Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Left Side Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder Secondary Left Side Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug Primary Right Sided Light Source Diode laser XLED1 AMH DG4 Hg Other Note: If laser chosen, then laser kit (containing fluorescent target, fiber coupler, homogenizer, fiber collimator & interlock) is required Right Side Excitation Filter Large GRP filter in holder (480 x 40nm) Large blank filter holder EPI Light Source AMH DG4 XLED1 Hg MicroPoint Other Secondary Right Side Light Source Beamsplitters (Choose one or more) 30 EPI:70 Laser Beamsplitter Plug 50 EPI:50 Laser Beamsplitter Plug 70 EPI:30 Laser Beamsplitter plug 100% EPI Plug 0% EPI (Blank) Plug EPI/ Mosaic Beamsplitter 30 EPI:70 Laser Beamsplitter Plug 100% EPI Plug 50 EPI:50 Laser Beamsplitter Plug 0% EPI (Blank) Plug 70 EPI:30 Laser Beamsplitter Plug 5 Optional EPI Excitation Filters (Choose one or more if required) FITC exciter filter GFP exciter filter Rhodamine exciter filter Blank filter holder Page 7 of 9

Product Drawings Dimensions in mm [inches] Fields of Illumination (FoI) 7201 97 [3.8] 80 [3.1] Model 7201 7206 FOV (Lamp house) Diagonal, mm 18.8 7.9 76.2 [3.0] 0 FOV (Lamp house) XY, mm 15.2 x 11.3 5.4 x 4.1 FOV 0.4 mm fiber ZC* x2 (mm)** 13.7 x 11.3 4.7 x 4.1 97 [3.8] FOV 0.4 mm fiber ZC x1 (mm)*** FOV 0.2 mm fiber ZC x2 (mm)** FOV 0.2 mm fiber ZC x1 (mm)** 7.2 3.0 6.5 2.8 3.6 1.6 146 [5.8] + 100 [4] Fiber Bend Radius Laser Fiber Collimator Mosaic Lamphouse Adapter 175 [6.88] (Lamphouse Attachment Plane) DMD effective pixel size (µm) 19.0 8.0 *ZC = Zoom Collimator X2 = max; X1 = min ** Intersection of circle and DMD rectangle *** Circular field of illumination Moves 38.1[1.50] Removeable Beamsplitter 57 [2.2] Ø Cylinder Moves 38.1[1.50] 76.2 [3.0] 0 See Table Weights: Mosaic Body = 3.5 kg [7.5 lb] 160 [6.3] Mosaic Body = 4.5 kg [9.8 lb] 7206 80 [3.1] Body Dimensions Model Part Number Length 7201 MEC-04686 369.06 mm [14.53] 76.2 [3.0] 0 7206 MEC-04729 333.00 mm [13.1] (Laser Input Attachment) 146 [5.8] + 100 [4] Fiber Bend Radius Mosaic Lamphouse Adapter 160 [6.3] 229 [9.0] 240 [9.375] (Lamphouse Attachment Plane) Laser Fiber Collimator Removeable Beamsplitter 57 [2.2] Ø Cylinder Moves 38.1[1.50] Moves 38.1[1.50] 76.2 [3.0] 0 333 [13.1] Page 8 of 9

Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: /contact Our regional headquarters are: Europe Belfast, Northern Ireland Japan Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 3518 6488 Fax +44 (28) 9031 0792 Fax +81 (3) 3518 6489 North America China Connecticut, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 5129 4977 Fax +1 (860) 290 9566 Fax +86 (10) 6445 5401 Items shipped with your Mosaic: 1x DMD Head assembly, Mosaic II 1x PLX and daughter board pair, programmed 1x 10 SCSI-3 Ultra LVD/SE MD698 cable 1x TPES15-T050PP-7 Mosaic custom power supply 1x 3m mains cable for TPES15-T050PP-7 1x First surface mirror 10x Green Post-It notes 1x Allen key (0.05 ) 1x T-handle (3/32) 1x LED Maglite, with 2 xaa batteries 1x Maglite clamp 1x Mosaic post holder 1x Mosaic foot 1x NT-59-000 4 stainless steel post (1/4-20 UNC) 1x NT-58-999 2 stainless steel post (1/4-20 UNC) 1x Zeiss male flange 1x BNC finger assembly 1x User guide NOTE: Laser radiation is only present in Mosaic systems fitted with a laser. Some Mosaic systems use non laser-based light sources. Minimum Computer Requirements: The imaging computer must have two adjacent PCI slots (with exceptions) and a bay for BNC Trigger connectors. Application software for the Mosaic Digital Diaphragm System is typically integrated into the imaging software provided for the microscope. Operating & Storage Conditions Operating Temperature: 0 C to 30 C ambient Relative Humidity: < 70% (non-condensing) Storage Temperature -25 C to 50 C Power Requirements 100-240 VAC, 50-60 Hz, 1.0 A Windows is a registered trademark of Microsoft Corporation. MMosaicSS 0213 R1 Page 9 of 9