Modular Lube Lubrication Systems System Controls

Similar documents
SureFire PDI Lubricator

Part-Turn Electric Multi-Turn Electric

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO NOTE

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Model Material Lamp type LED color Voltage Distribution Lens

Electromagnetic Block Valves Direct Acting

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

High performance circuit breakers

Bimetal Temperature Switch

SCALE & WEIGHT DISPLAYS

Level Measurement Point level measurement - RF Capacitance switches

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

SQM40/41 Actuators for air and gas dampers

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

2.9 Sigma/ 2 Plunger Metering Pumps

Gear Pump Units For single-line centralized lubrication systems

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

GP-500 SERIES - Low Voltage

Linear flow controls VFC Linear flow controls with actuator IFC

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

1900/25 Vibration Monitor

LAUREL ELECTRONICS, INC.

WCHE BTU/Hr Watts

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

Mechanical flow switch for On/Off control

Single Point Flow Monitor SW118 SW119

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

Illustrated Feature. Options

P1350P1/P1500E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

Gear Pump Units. For single-line lubrication systems

DFT. Compact Paddle Flow Sensor

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Magnecraft Power Relays

Signet 2250 Hydrostatic Level Sensor

WCHE BTU/Hr Watts

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

EXLUX ECOLUX C-LUX 6480 Series

Linear flow control with actuator IFC

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

ALLEN BRADLEY TIMING RELAY

Photoelectric Sensors E3F2

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

P Output Ratings. Dimensions and Weights. Prime Rating

GENESIS Indoor Air Conditioners

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

WLB SERIES HID Lighting for Hose Down Applications

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Process Transmitter RMA 422

EXLUX ECOLUX 6480 Series

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

SERIES 400 SERIES 620

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Nessie Coils for VDH and VDHT valves

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Features. Specifications. Finish. Notes

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Liquid Level Sensor AKS 4100U

Dissolved Oxygen Transmitter

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DVZ. Compact Vortex Flowmeter. for Low Viscosity Liquids

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Lt DELTA USA, Inc

XML LED X M L L E D. Explosionproof Linear LED Lighting

WCHE BTU/Hr Watts

APPLICATIONS. Automatic warehouse. Trasportation lines

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

TELEDYNE HASTINGS INSTRUMENTS

PILOT VALVES AND NEMA 4 ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS

Data Sheet Definite Purpose Contactors Ex9CK Series

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Transcription:

Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump. Off Time On Time (Cycle Time) (Pumping Time) Min Max Min Max 20 Sec. 24 Hrs. 10 Sec. Power Requirements Model 84511 Economy Timer for Single Stroke Pumps Approvals Switch 1 Min. 120/230 VAC 120 VAC, 5 Amps 24 Sec. 50/60 Hz UL, CSA 230 VAC, 1.5 Amps Built-In Program Options Ambient Operating Temperature Range 3 Hr. Program Prelube Dimensions-in./mm Rating Minimum Maximum Memory Function Yes No Yes No NEMA #1 8¹ ₄ 6¹³ ₁₆ 4¹⁵ ₁₆ 0 F 130 F 210 173 125-18 C 54 C Note: Refer to Technical Manual for a full explanation of available program options. Uses a timing motor, cam and Micro-Switch to turn pump off and on. NEMA 1 enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive. Off Time On Time (Cycle Time) (Pumping Time) Power Approvals Switch Requirements Min Max Min Max 5 Min. 1 Hr. 30 Sec. 90 Sec. 120 VAC, 60 Hz UL, CSA 10 Amps Note: Off-time selectable in 5 minute intervals. Dimensions - in. / mm Rating NEMA 1 5 / 127 3¹ ₄ / 82.5 3¹ ₂ / 89 Flow Meter Flow meter measures and records oil flow to the system. Model Register Oil Inlet/Outlet Max. Pressure Rating psig / bar 87806 200 counts per pint ¹ ₄" NPTF(F) 6000 / 408 Cycle Monitors Cycle Monitors monitor and record oil flow volume delivered to lube points and signal fault if flow stops or diminishes significantly. Max. System(s) Electrical Power Display Alarm Time 3rd Party Model Monitored Requirements Record Approvals pints Min. Max. 87610 1 115 VAC, 50-60 Hz 37.5 10 CSA Class I, Group D 999,999 87611 2 24 VDC Sec. Min. Class II, Group E, F & G 26

Model 84015 Timer 12-24V DC Solid-state microprocessor-based controller for automated lubrication systems on mobile equipment or where AC power is not available. Rugged construction with liquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle. Off Time** (Cycle Time) Min. Max. 2.5 Min. 80 Min. 75 Sec. * Less load. ** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes. Fixed On Time Power Switch (Pumping Time) Requirements 10-30 VDC 25 MA* 5 Amps Rating NEMA 12 Ambient Operating Temperature Range Dimensions-in. / mm Minimum Maximum 5¹ ₄ / 133 3¹ ₈ / 79 3 / 76 0 F / -18 C 131 F / 55 C Model 85530 Lubrication System Controller Controls lubrication frequency, master divider valve cycle and monitors supply line pressure. The LCD displays operating status. Lube Cycle Timer Mode Counter Mode Off Time Off Counts Min. Max. Min. Max. 1. 9,900 1 99,000 Minute Minutes Count Counts * Minimum duration of count signal is 33 milliseconds. Max. Count Rate* 30/Sec. @ 50% Duty Cycle Pumping Time Before Alarm Min. Max. 1 99 Minute Minutes Power Requirements (less load) Pump, Ambient Solenoid, Temperature Dimensions-in. / mm Voltage Current or Alarm Range Rating 120 VAC, 50/60 Hz 85 MA 360 VA 32 to 122 F NEMA 9¹ ₂ 8¹⁵ ₁₆ 4¹ ₈ 230 VAC, 50/60 HZ 45 MA -0 to +50 C 12 241 227 105 24 VDC 250 MA 5 Amps Notes: Model 85530 is CSA/NRTL approved. 27

Model 85500 System Sentry II The ultimate automated lubrication system controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length or bearing back-pressure. System Sentry II is always on the job, making sure that every lube point is lubricated when it s supposed to be. Solid-state controller with LCD status display and 16-button keypad for system programming Controls up to two pumps with as many as two lube zones per pump Fully programmable monitoring and alarm functions Be set up to monitor every lube point for lubricant flow during each lubrication event Easy to understand prompts reported by simple English language messages in real time Some functions require optional accessories. See chart on page 30. Use a maximum or 48 sensors and three accessory Sensor Boards (order separately 16 sensors per board) to monitor lube points. Lube Cycle Max. Pumping Time Timer Mode Counter Mode Off Time Off Counts Count Before Alarm Net Min. Max. Min. Max. Rate* Min. Max. Wt. 1 9,900 1 99,000 Second Minutes Count Counts * Minimum duration of count signal is 33 milliseconds. Note: Model 85500 is CSA/NRTL approved. * No external load, no sensors. 30/Sec. @ 50% Duty Cycle 1 99 18 lbs. Second Minutes 8.1 kg Power Requirements (less load) Pump, Ambient Solenoid, Temperature Dimensions-in. / mm Voltage Current or Alarm Range Rating 120 VAC, 50/60 Hz 250 MA* 360 VA 32 to 122 F NEMA 16 14 4⁷ ₈ 230 VAC, 50/60 HZ 125 MA* 0 to 50 C 12 241 227 105 24 VDC 600 MA* 5 Amps Model 243100 Sensor Wire 100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors to monitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters). 28

Model 247333 Pressure Transducer Pressure Transducer signals actual system pressure via LCD display of System Sentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximum length of wire between transducer and monitor is 30 (9.1m) feet. Range Accuracy Proof Pressure Ambient Voltage Connection Temp. Input Output Offset NEMA 4X 0 to 7500 psig ¹ ₄" NPT -20 to 180 F 10 to 1-6 1 Rating ±1% 4000 psi 517 bar Male Thread -29 to 82 C 30 VDC VDC 300 Series 276 bar VDC Stainless Steel Model 250365 Sensor Board Plug-in accessory board used with Model 85500 that allows the attachment of up to 16 lube flow sensors. Model 85500 comes without boards installed and can hold up to a total of three. Sensor Assemblies Sensor assemblies consist of a check body and lube sensor with attached 30' cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors have a ³ ₈" pipe thread for conduit connection and a Viton O-ring seal. Check bodies terminate in a ¹ ₈" NPTF male thread for attachment to a bearing or other lubricant inlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to monitor is 500 feet (152m). Min. Interval Lubricant Min. Flow Model Description Construction Between Lube Temp. Range Per Event Flow Event 250400 250490 250500 250590 Straight Sensor Assembly 90 Sensor Assembly Straight Sensor Assembly Brass Sensor & Plated Steel Check Body Sensor & Check Body 90 Sensor 316 Assembly Stainless Steel 32 to 145 F 0 to 63 C.004 cu. in./.066 cc @ 32 F /0 C to 125 F/52 C.008 cu. in./.131 cc @ 126 F to 145 F (53 C to 63 C) 30 Seconds 29

Use This Guide to Select Accessories for Model 85500 System Sentry II Pressure Sensor Sensor Wire Function Switch Board Sensors #243100 (100') #69630 #250365 Note 2 Note 3 Lube Controller 1 Pump, 1 Zone Optional 1 Note 1 Lube Controller, 1 Pump, Optional 1 Up to 3 Zones Lube Controller, 2 Pumps, 1 Zone Optional 1 Per Pump Lube Controller, 2 Pumps, Up to 2 Optional 1 Zones Per Pump Lube Point Required Required Required Monitoring 1 per each 1 per Quantity 48 Points 16 Sensors Lube Point As Needed Note 1: Controller may be operated without a pressure switch. Pressure switch may be used to monitor supply line pressure. Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors in straight or 90 configuration as required. Note 3: Maximum distance between monitor and sensor is 500' (152 meters). 30

Electric Solenoid-Operated Air Valves Electrical Characteristics Model Type Power Inrush Holding Air Ambient Cv Max. Conduit Requirements Current Current Inlet/ Temperature Factor Pressure Connection Amps Amps Outlet Range psi / bar 110 VAC, 50 Hz 350244 120 VAC, 60 Hz.11.07 4-Way 8.4 VA 0 to 120 F 220 VAC, 50 Hz -18 to 49 C 1.2 350245 240 VAC, 60 Hz.055.035 8.4 VA 1 4" 1 2" NPS(F) 110 VAC, 50 Hz NPT(F) 350241 120 VAC, 60 Hz.11.07 8.4 VA 150 220 VAC, 50 Hz 10.3 350242 240 VAC, 60 Hz.055.035.18 3-Way 8.4 VA 12 VDC 0 to 140 F 350282 6 Watts 1 8" -18 to 60 C N/A N/A 24 VDC NPT(F) 350283 6 Watts N/A 68586 2-Way 120V, 60 Hz 3 8" 12 VA.2.1 NPT(F) 2.4 1 2" NPT(F) 274398 3-Way 24 VDC 1 N/A N/A 4" 8.5 Watts NPT(F).5 N/A 244727 3-Way 110 VAC, 50 Hz 3 8" 0 to 120 F 120 VAC, 60 Hz.12.09 NPT(F) -18 to 49 C 11 VA 4.4 1 2" NPT(F) Model 83354 Signal Monitor Designed to provide visual and audible indication of system operation and failure. Utilizes signal from system controller. Includes model 69606 Alarm Horn mounted on enclosure door. Indicator Lamps Power Requirement Power Lube System On System On Failure 115 VAC 50/60 Hz Green Amber Red 35 VA Audible Dimensions - in / mm Alarm 69606 Horn 10 8 6 (included) 254 203 152 31