BE3-GPR GENERATOR PROTECTIVE RELAY

Similar documents
ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

www. ElectricalPartManuals. com l Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

Intertie Protection M 3520

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Standard RS232 RS ma

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Type MG-6 Auxiliary Relay Class 1E

PRINCIPLES AND APPLICATIONS

Magnecraft Power Relays

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Series CT7N Bimetallic Overload Relays

SAL Series Wireless Clock (V1)

MILLITARY SPECIFICATION SHEET

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Noise Detector ND-1 Operating Manual

Bulletin 190 IEC Modular Starter System

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

10MHz Source/Inserter

Operating instructions Electronic preset counter Type series 717

Instruction Manual Model BlockUpconverter

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Type Contact form Model

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Instruction Manual Model Downconverter

Model IQ4-PC User Manual Revision Date:

HS-509 VIBRATION TRIP MODULE

Multifunction Digital Timer

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Understanding VFD. Variable Frequency Drive. nfi. nfi

Generator protection relay

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

multi-function meters

Single Axis Position Controller

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

R-1580A Microwave Downconverter. Product Brochure

Automated Local Loop Test System

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Smart-Encoder : Optical Incremental

Model /29S RF Splitter

Instruction Manual Model # Block Upconverter

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Operating Manual RISH OPTIMA VAF

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

Rack mounted telephone- and leased line modem for industrial applications

MODEL 2018 OPERATION MANUAL Firmware Version

SYNTHESIZED COMMUNICATION CONVERTERS

Process Transmitter RMA 422

EZ Encoder : Optical Incremental (P Series)

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

EC456 Power System Protection Lab #1 Overcurrent Protection Relay

Switching Power Module

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DCP100 Digital Control Programmer Specifications

Model 1476-C SuperQuad HR

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Fibre Optic Modem ODW-611

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Advanced Test Equipment Rentals ATEC (2832)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

MATE3 Owner s Manual Addendum

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Photoelectrics Through-beam Type PA18C.T..., DC

CAMTO LTD. Arc detecting system DC/AC

Fibre Optic Modem ODW-622

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

1 Summary screens are split into two with one screen showing Overcurrent settings and the

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

LONWORKS Fibre Optic Converter

SC26 Magnetic Field Cancelling System

High-Value 100 Series (Outdoor)

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

ODW-621. RS-232 Point-to-point applications

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Vorne Industries. 2000B Series Buffered Display Users Manual Industrial Drive Itasca, IL (630) Telefax (630)

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Magnetic and Hydraulic-Magnetic Circuit Breaker

X-Band Redundant LNB Systems

Data Pattern Generator

Modular Lube Lubrication Systems System Controls

Transcription:

BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based design provides high accuracy, reliability and repeatability. It is extremely easy to set up with an IBM compatible PC or from a menu-driven settings screen or from the front panel. The digital readout makes calibration quick, easy, and accurate without the need to bench test the relay to verify settings. FEATURES Microprocessor-based design 10 protective functions Displays relay set points Front panel programmability PC programmable True RMS sensing Isolated current inputs Adjustable trip set points Adjustable reset set points Adjustable time delays for each function Accepts single phase, three phase 3 or 4 wire voltage inputs 12 or 24 Vdc power inputs IEEE C37.90.1-1989 for Surge Withstand IEEE C37.90.1-1989 for Fast Transient UL Standard 508 recognized CSA Standard 14 certified Gost R Certified #POCC US.ME05-B03391 Accepts 1 or 5 Amp CT secondaries WINDOWS SOFTWARE Interface for setting and communicating with Basler products (standard) Request BESTCOMS-BE3GPR ADDITIONAL INFORMATION INSTRUCTION MANUAL Request Publication 9278200993 TIMING CURVES Request Publication 9252000999 DESCRIPTION and FUNCTIONS Pages 2 and 3 FEATURES Page 4 SPECIFICATIONS Page 5 INTERCONNECT, DISPLAY and DIMENSIONS Pages 6 and 7 ORDERING INFORMATION Page 8 ROUTE 143, BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE 618-654-2341 FAX 618-654-2351 UEG-7 10-06

DESCRIPTION BE3-GPR (Generator protective relay) utilizes microprocessor-based technology to provide total generator protection in a single package. This microprocessor design allows for exact set point adjustment and precise generator system protection. BE3-GPR provides multiple functions in a single case, and that adds up to significant installation and setup savings. BE3-GPR allows for direct setup via a PC for easy, fast setup. Low sensing burdens mean that BE3-GPR does not require dedicated PTs and CTs. PROTECTIVE FUNCTIONS 27/59 Under/Overvoltage Trip points are settable from 70 to 600 Vac in 1 volt steps. Reset set points are settable from 70 to 600 Vac in 1 volt steps. 81O/U Under/Overfrequency Trip points are settable from 35 to 75 Hz in 0.1 Hz steps. Reset set points are settable from 35 to 75 Hz in 0.1 Hz steps. 81U Underfrequency Trip point is settable from 35 to 75 Hz in 0.1 Hz steps. Reset set points are settable from 35 to 75 Hz in 0.1 Hz steps. 32R Reverse Power Trip point is settable from 50 to 999 Watts in 1 Watt steps. Reset set points settable from 50 to 999 Watts in 1 Watt steps. Style Option "P" provides single element reverse power protection. Style Option "W" provides three phase three element reverse power protection. 25 Sync Check with Dead Bus Phase Angle is settable from 2 to 20 in 1 steps. Voltage difference is settable from 1 to 100 Vac in 1 volt steps. Time delay is adjustable from.2-2 seconds in 0.1 second steps. Slip frequency is adjustable from.1 to 1.0 Hz in.1 Hz steps. Dead bus is adjustable from 10 to 50 volts in 1 volt steps. Breaker closure is selectable for Gen Hz > Bus Hz only or with Gen Hz > or < Bus Hz. 47 Phase Balance Trip point is settable from 5 to 100 Volts in 1 Volt steps. Reset set points are settable from 5 to 100 Volts in 1 Volt steps. 40 Loss of Excitation Measures Reactive Current into the paralleled generator. Trip point is settable from 0.15 to 2.5 in 0.01 Amp steps (5 Amp). Trip point is settable from 0.03 to 0.5 in 0.01 Amp steps (1 Amp). Reset point is settable from 0.15 to 2.5 in 0.01 Amp steps (5 Amp). Reset point is settable from 0.03 to 0.5 in 0.01 Amp steps (1 Amp). 2

PROTECTIVE FUNCTIONS, continued 51N* Neutral Ground Fault Trip point is settable from 0.2 to 3 in 0.01 Amp steps (5 Amp). Trip point is settable from 0.04 to 0.6 in 0.01 Amp steps (1 Amp). Reset point is settable from 0.2 to 3 in 0.01 Amp steps (5 Amp). Reset point is settable from 0.04 to 0.6 in 0.01 Amp steps (1 Amp). 51/27R* Three Phase Time Overcurrent Trip point is settable from 0.1 to 9.99A in 0.1 Amp steps (5 Amp). with Voltage Restraint Trip point is settable from 0.1 to 2.00A in 0.01 Amp steps (1 Amp). Reset point is settable from 0.1 to 9.99A in 0.1 Amp steps (5 Amp). Reset point is settable from 0.1 to 2.00A in 0.01 Amp steps (1 Amp). Time dial settings 0.0 to 9.9 in 0.1 increments (100 settings). Time curves: 16 inverse and 1 fixed time curve, including: S1 - CO Short Inverse V1 - CO Very Inverse S2 - IAC Short Inverse V2 - IAC Very Inverse L1 - CO Long Inverse E1 - CO Extremely Inverse L2 - IAC Long Inverse E2 - IAC Extremely Inverse D - CO Definite A - BS, IEC Standard Inverse M - CO Moderately Inverse B - BS, IEC Very Inverse I1 - CO Inverse C - BS, IEC Extremely Inverse I2 - IAC Inverse G - BS, IEC Long Time Inverse F - Fixed Time Voltage Restraint characteristics: Under fault conditions, system voltage may collapse to a low value compared to the relatively small voltage drop associated with overloads. The time overcurrent relay with voltage restraint decreases the current pickup proportionally to this voltage reduction to increase overcurrent sensitivity of the relay during fault conditions. * The 51N and 51/27R functions and mutually exclusive. 3

FEATURES Front Panel Programmability: The front panel of the BE3-GPR has a LCD display and pushbuttons for programming. These buttons allow for the selection of items like energized or de-energized contact tripping, threshold adjustments, reset adjustments, time delays and enable/disable of specific protection features and much more. This front panel programming takes the guesswork out of relay setup. The front panel pushbuttons can be locked out for added security. Watchdog Timer: The watchdog timer monitors the microprocessor for specific indications of proper operation. If something occurs to inhibit proper operation, the watchdog timer energizes an output relay with a Form C contact arrangement for customer use. Packaging: The BE3-GPR is provided either in a semi-flush mounting package or a behind-the-panel mounting configuration. Compression type terminal strips are located so that wiring is simple. These terminals accept 1-#10 Ga. wire or 2-#14 Ga. wires. Programmable Contact Status: The output contacts can be programmed to either energize or de-energize to trip. In other words, the contact status can be selected so that the relay, for a particular function, either picks up or drops out when the setting is exceeded. Reset Input: An input is available to allow the relay to automatically reset when the fault goes away, or the relay can maintain an output until this input is momentarily received. Disable Input: A contact input disables the relay to avoid nuisance tripping during generator build-up. RS232 Communications: BESTCOMS is a Windows -based PC software program that is included with each BE3-GPR relay. This program provides a user-friendly means to set up all parameters of the BE3-GPR. Also, communications can be made using a terminal emulation program such as TELIX to send (type) or receive (display) ASCII characters in serial data format. Figure 1 - Functional Block Diagram Note: The integrated design of BE3-GPR greatly simplifies wiring over discrete relays. 4

SPECIFICATIONS OUTPUTS: Each protective function has a Form C output contact arrangement. Contact ratings: Resistive 120/240Vac - Make 30A for 0.2 seconds, carry 7A continuously, break 7A. 250Vdc - Make 30A for 0.2 seconds, carry 7A continuously, break 0.3A. (L/R=0.04) 10A @ 30Vdc resistive Inductive 120/240Vac, 125 Vdc - Break 0.3A (L/R=0.04) 5A @ 30Vdc Inductive 0.3A @ 240Vac Inductive (L/R=0.04) Surge withstand Capability Qualified to IEEE C37.90.1-1989 standard Surge Withstand Capability (SWC) tests for protective relays and relay systems Fast Transient Qualified to IEEE C37.90.1-1989 Radio Frequency Interference (RFI) Field tested using five watt transceiver operating at random frequencies centered around 144 MHz and 440 MHz INPUTS: DC Power Input (Battery): 12Vdc nominal systems (8-16Vdc) ACCURACIES OFFERED: INPUTS (continued) 24Vdc nominal systems (16-32Vdc) (both negative ground systems) Power input burden is 6.5 Watts. Generator/Bus Voltage Input: 100 to 480Vac nominals, 50/60Hz @ <1VA/phase 1.2 times nominal continuously 1.5 times nominal for 10 seconds May be single phase, three phase three wire or three phase four wire. Generator Line Current: 1 or 5 Amp input @ 1VA/phase 2 times nominal continuously 10 times nominal for 1 second ENVIRONMENTAL: Vibration: 10 to 500 Hz @ 2 Gs in three mutually perpendicular planes Shock:15 Gs in each of three mutually perpendicular axes Ambient Operating Temperature range: -25 C (-13 F) to +60 C (+149 F). (Display readout is limited to -25 C to +60 C operation.) AGENCY RATINGS: UL Standard 508 CSA Certified Gost R Certified #POCC US.ME05-B03391 Patent #5309312 Function Accuracy Repeatability Steps Temp 27/59 ±2% ±1.0% 1V -25 C to +60 C 81O/U ±0.02 Hz ±0.004Hz 0.1Hz -25 C to +60 C 32R ±2% or ±10W@PF>I0.5I ±1.0% 1W -25 C to +60 C ±5% or ±10W@PF>I0.5I ±1.0% 1W -25 C to +25 C 25 (Phase Angle) ±0.5 max ±0.1 1-25 C to +60 C (Delta V) ±3% or ±2V ±1.5% 1V -25 C to +60 C (Slip Frequency) ±0.02Hz ±0.01Hz 0.1Hz -25 C to +60 C 47 ±3% or ±2V ±1% 1V -25 C to +60 C 40 ±3.5% or ±0.05A ±1% 0.01A -25 C to +60 C 51N ±2% ±1% 0.01A -25 C to +60 C 51/27R ±2.5% ±1% 0.1/0.01A -25 C to +60 C Accuracy of all timing functions is ±1% or less than ±50 msec, whichever is greater. 5

CONNECTIONS and DISPLAY Figure 2 - Typical Interconnection Diagram BE3-GPR-P1 or BE3-GPR-W1 with 3 Phase L-L Sensing and 5A CTs A 2 3 4 6 7 8 9 10 11 12 13 16 18 20 22 24 26 31 32 33 34 35 Generator Protective Relay BE3-GPR Raise B E SYNC-CHECK UNDER OVER PHASE REACTIVE VOLTAGE CURRENT FREQUENCY 1 2 ANGLE VOLTS AMPS WATTS HERTZ GND-FAULT DEAD-BUS REV-PWR DELTA TRIP RESET TIME-DELAY SECONDS DEGREES ON OFF Sync Lower Select C D 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 A B C D E Red LED illuminates for a sync-check condition. Pushbutton used to toggle the menu selections, scroll for set point adjustments, fast scroll by pressing for one second, and, when simultaneously pressed with the SELECT button, makes the menu selection sequence move in the forward direction. Pushbutton used to scroll and fast scroll by holding for one second for set point adjustments, and, when simultaneously pressed with the SELECT button, to reverse the menu selection sequence from the forward direction. Pushbutton used to simultaneously save settings in the nonvolatile memory and move on to the next selection sequence. Also, when pressed in conjunction with either the RAISE or LOWER button, the direction of the user option sequence can be forced forward or reverse, respectively. LCD provides the primary visual interface to the user. Used when performing Relay settings and monitoring Relay functions. Figure 3 - Front Panel Display 6

DIMENSIONS 8.83 (224.3) OVR VOLT UND VOLT OVR FREQ UND FREQ1 UND FREQ2 NO FAULT PH BAL WDT FAIL REV PWR REACT CUR SYNC CHK BATT NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC - + 4.33 (110.0) Figure 4 - Dimensions - Front panel view (Behind-the-panel Mounting) Figure 5 - Dimensions - Side view (Behind-the-panel Mounting) Figure 6 - Dimensions - Front panel view (Semi-flush Mounting) Figure 7 - Dimensions - Side view (Semi-flush Mounting) NOTE: All dimensions are in inches (millimeters). All drawings and data subject to change without notice. 7

ORDERING STYLE NUMBER SELECTION CHART Example of style number: BE3-GPR-P2BVSF POWER SUPPLY Basler Part Number 9334503101 Input: AC or DC AC 85-265Vac, 47-440Hz DC 110-330Vdc Output: 24Vdc, 31.2 Watts P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE Tel +33 3.88.87.1010 Fax +33 3.88.87.0808 e-mail: beifrance@basler.com Route 143, Box 269, Highland, Illinois U.S.A. 62249 Tel +1 618.654.2341 Fax +1 618.654.2351 e-mail: info@basler.com www.basler.com No. 1300 North Zhongshan Road, Wujiang Economic Development Zone Suzhou, Jiangsu Province, P.R. China 215200 Tel +86(0)512 6346 1730 Fax +86(0)512 6346 1760 e-mail: beichina@basler.com Printed in U.S.A.