www.solarstar-elec.com.cn Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China 518110 Tel/Fax:+86-755-83178592 info@solarstar-elec.com.cn www.solarstar-elec.com.cn
Company profile Solarstar Electronics Industrial Co.,Ltd. has been dedicated in manufacturing Lan Cable,Telephone Cable and Coaxial Cable for more than 15 years.we always take quality as the life,always focus in providing quality cables,we put a great deal of efforts in R&D,introduction professional engineers,high end production equipments and test devices. Our cables are certificated by ministry of information industry of China, and complied with CE,RoHS and ISO-9001-2000 quality and management system.for Cat5e and Cat6 cables,pass Channel and Permanent link test,and got the approval by CNAS. Solarstar Electronics has cooperated with China Telecom,China Unicom and has exported for more than 40 countries,including Germany,UK,Italy,Russia,Canada,USA,Brazil,Australia and so on.we have a good reputation in the Cable field,due to our reliable quality,our care for customer service and competitive prices. Nowadays,with the fast growing Information Technology,production technique needs to be upgraded all the time.we will keep the pace with the industry trends,and manufacture excellent products to satisfy our customers needs. Table of Contents Cat5e UTP Cable Cat5e FTP Cable Cat5e SFTP cable Outdoor Cat5e FTP Cable with Messenger wire Cat6 UTP Cable Cat6 FTP cable Outdoor Cat6 UTP Cable Cat6a UTP Cable Cat3 UTP 25 Pairs Cable Cat3 UTP 50 Pairs Cable LAN CABLE Patch Cord Fiber Optic Patch Cord Composite Cable:2*RG6 Quad Shield CCS with 2*Cat6 & RG6 Quad Shielded with Cat5e Cable RG59 Mini Coax,24AWG,95% Braid & RG6 Standard Shield CCS Certificate & FLUKE test report 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Cat5e UTP Cable Cat5e FTP Cable Performance Category = Cat 5e Conductor = Bare Copper Jacket = PVC,LSZH,LLDPE(outdoor) Cable Configuration = UTP (Unshielded Twisted Pair) Performance Category = Cat 5e Conductor = Bare Copper Jacket = PVC,LSZH,LLDPE(outdoor) Configuration Shield Type = Overall Foil Cable Configuration = F/UTP (Foiled/Unshielded Twisted Pair) 10Base-T, 100Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155Mbps ATM, 622Mbps ATM, 1000Base-T 10Base-T, 100Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155Mbps ATM, 622Mbps ATM, 1000Base-T CATEGORY 5e UTP 4-PAIR CABLE CATEGORY 5e FTP 4-PAIR CABLE Frequency Return loss Attenuation NEXT PSNEXT ELFEXT PSELFEXT Delay Frequency Return loss Attenuation NEXT PSNEXT ELFEXT PSELFEXT Delay (MHz) (Min db) Max (db/100m) (Min db) Min (db) Min (db/100m) Min (db/100m) Max (ns/100m) (MHz) (Min db) Max (db/100m) (Min db) Min (db) Min (db/100m) Min (db/100m) Max (ns/100m) 0.772 19.4 1.8 67.0 64.0 66 63 575 0.772 19.4 1.8 67.0 64.0 66 63 575 1 20.0 2.0 65.3 62.3 63.8 60.8 570 1 20.0 2.0 65.3 62.3 63.8 60.8 570 4 23.0 4.1 56.3 53.3 51.7 48.7 552 4 23.0 4.1 56.3 53.3 51.7 48.7 552 8 24.5 5.8 51.8 48.8 45.7 42.7 546.7 8 24.5 5.8 51.8 48.8 45.7 42.7 546.7 10 25.0 6.5 50.3 47.3 43.8 40.8 545.4 10 25.0 6.5 50.3 47.3 43.8 40.8 545.4 16 25.0 8.2 47.3 44.3 39.7 36.7 543 16 25.0 8.2 47.3 44.3 39.7 36.7 543 20 25.0 9.3 45.8 42.8 37.7 34.7 542 20 25.0 9.3 45.8 42.8 37.7 34.7 542 25 24.3 10.4 44.3 41.3 35.8 32.8 541.2 25 24.3 10.4 44.3 41.3 35.8 32.8 541.2 31.25 23.6 11.7 42.9 39.9 33.9 30.9 540.4 31.25 23.6 11.7 42.9 39.9 33.9 30.9 540.4 62.5 21.5 17.0 38.4 35.4 27.8 24.8 538.6 62.5 21.5 17.0 38.4 35.4 27.8 24.8 538.6 100 20.1 22.0 35.3 32.3 23.8 20.8 537.6 100 20.1 22.0 35.3 32.3 23.8 20.8 537.6 1 2
Cat5e SFTP cable OUTDOOR Cat5e FTP Cable with Messenger wire Performance Category = Cat 5e Conductor = Bare Copper Jacket = PVC,LSZH,LLDPE(outdoor) Configuration Shielded = Yes Shield Type = Overall Foil and Overall Copper Braid Cable Configuration = SF/UTP (Screened Braided and Foiled/Unshielded Twisted Pair) Performance Category = Cat 5e Jacket = LLDPE Configuration Shield Type = Overall Foil Cable Configuration = F/UTP (Foiled/Unshielded Twisted Pair) Messenger = Steel Jacket 10Base-T, 100Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155Mbps ATM, 622Mbps ATM, 1000Base-T Other high-performance applications Outside Plant Direct Burial CATEGORY 5e SFTP 4-PAIR CABLE FREQUENCY RL SRL ATTEN NEXT PSNEXT ELFEXT PSELFEXT DELAY (MHZ) (DB) (DB) (DB/100M) (DB/100M) (MHZ) (DB/100M) (DB/100M) (NS/100M) 1 20 28 2 65.1 62.5 64.3 62 <45.0 4 23 28 4 57.2 52.7 53.1 52 <45.0 8 24.5 28 5.5 52.3 49.1 45.9 47 <45.0 10 25 28 6.3 50.9 47.3 44.2 43 <45.0 16 25 28 8 48.2 44.9 29.8 40 <45.0 20 24.3 29 9.5 46.3 42.7 38.6 39 <45.0 25 23.6 25 10.7 44.1 42.1 36.4 35 <45.0 31.25 21.5 26 11.2 42.9 38.7 35.1 32 <45.0 62.5 20.1 27 16.4 39.3 37.9 29.5 29 <45.0 100 18.8 26.5 21.4 36.5 32.8 26.2 27.6 <45.0 10Base-T, 100Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155Mbps ATM, 622Mbps ATM, 1000Base-T OUTDOOR Cat5e FTP Cable with Messenger wire Frequency Return loss Attenuation NEXT PSNEXT ELFEXT PSELFEXT Delay (MHz) (Min db) Max (db/100m) (Min db) Min (db) Min (db/100m) Min (db/100m) Max (ns/100m) 1 20 2 65.1 62.5 64.3 62 570 4 23 4 57.2 52.7 53.1 52 552 8 24.5 5.5 52.3 49.1 45.9 47 546.7 10 25 5.5 50.9 47.3 44.2 43 545.4 16 25 28 48.2 44.9 29.8 40 543 20 24.3 9.5 46.3 42.7 38.6 39 542 25 23.6 10.7 44.1 42.1 36.4 35 541.2 31.25 21.5 11.2 42.9 38.7 35.1 32 540.4 62.5 20.1 16.4 39.3 37.9 29.5 29 538.6 100 18.8 21.4 36.5 32.8 26.2 27.6 537.6 3 4
Cat6 UTP Cable Cat6 FTP cable: Performance Category = Cat 6 Wire/Cable Size (AWG) = 23 Conductor = Bare Copper Jacket = PVC,LSZH,LLDPE(outdoor) Cable Configuration = UTP (Unshielded Twisted Pair) 10Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155MbpsATM, 622 Mbps ATM, 1000Base-T, 10GBase-T CATEGORY 6 UTP 4-PAIR CABLE FREQUENCY RL ATTEN NEXT PSNEXT ELFEXT PSELFEXT DELAY (MHZ) (DB) (DB/100M) (DB/100M) (MHZ) (DB/100M) (DB/100M) (NS/100M) 0.772 19.5 1.78 76.2 75.3 70.2 73.1 570 1 20 2 65.1 62.5 64.3 71.7 565 4 23 4 57.2 52.7 53.1 68.2 559 10 24.5 5.5 52.3 49.1 45.9 67.1 553 16 25 7.33 50.9 47.3 44.2 65.2 547 20 25 8 48.2 44.9 29.8 57.3 542 25 24.3 9.5 46.3 42.7 38.6 54.1 539 31.3 23.6 10.7 44.1 42.1 36.4 51.9 535 62.5 21.5 16.21 42.9 38.7 35.1 48.9 529 100 20.1 18.97 39.3 37.9 29.5 45.3 526 200 18.8 29.32 36.5 32.8 26.2 41 520 250 18 31.85 33.1 30.1 24.3 37.2 515 Performance Category = Cat 6 Wire/Cable Size (AWG) = 23 Jacket = PVC,LSZH,LLDPE(outdoor) Configuration Shield Type = Overall Foil Cable Configuration = F/UTP (Foiled/Unshielded Twisted Pair) 10Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155MbpsATM, 622 Mbps ATM, 1000Base-T, 10GBase-T CATEGORY 6 FTP 4-PAIR CABLE FREQUENCY RL SRL ATTEN NEXT PSNEXT ELFEXT PSELFEXT DELAY (MHZ) (DB) (DB) (DB/100M) (DB/100M) (MHZ) (DB/100M) (DB/100M) (NS/100M) 0.772 20 28 2 67.8 65.5 68.2 65 550 1 2 65.1 62.5 64.3 62 553 4 23 28 4 57.2 52.7 53.1 52 552 10 6.3 50.9 47.3 44.2 43 545 16 25 28 8 48.2 44.9 29.8 40 538 25 10.7 44.1 42.1 36.4 35 534 62.5 20.1 27 16.4 39.3 37.9 29.5 29 532 100 21.4 36.5 32.8 26.2 27.6 520 200 17.2 24.9 19.2 34.9 30.5 23.4 25.3 517 250 20 25 23.6 18.8 16.3 28 28 25 26.5 22.4 18.7 32.8 28.6 22.6 23.7 515 5 6
OUTDOOR Cat6 UTP Cable Category 6A Cat6a UTP Cable Product Type Performance Category = Cat 6 Wire/Cable Size (AWG) = 23 Jacket = LLDPE(Black) Cable Configuration = UTP (Unshielded Twisted Pair) Product Type Wire/Cable Size (AWG) = 23 Insulation:PE,FEP Cross:PE,FEP Jacket:LSZH,PVC 10/100/1000Base-T 100Base-VG 155 Mbps and 622-Mpbs ATM Other high-performance applications Backbone Floor-to-floor backbone Horizontal cabling to desktop 10Base-T4, 100Base-TX, 100Base-VG-ANYLAN, 155MbpsATM, 622 Mbps ATM, 1000Base-T, 10GBase-T Other high-performance applications: Outside Plant Direct Burial Category 6a UTP 4-Pair Cable Category 6 UTP Outdoor 4-Pair Cable FREQUENCY RL ATTEN NEXT PSNEXT ELFEXT PSELFEXT DELAY (MHZ) (DB) (DB/100M) (DB/100M) (MHZ) (DB/100M) (DB/100M) (NS/100M) 0.772 19.5 1.78 76.2 75.3 70.2 73.1 570 1 20 2 65.1 62.5 64.3 71.7 565 4 23 4 57.2 52.7 53.1 68.2 559 10 24.5 5.5 52.3 49.1 45.9 67.1 553 16 25 7.33 50.9 47.3 44.2 65.2 547 20 25 8 48.2 44.9 29.8 57.3 542 25 24.3 9.5 46.3 42.7 38.6 54.1 539 31.3 23.6 10.7 44.1 42.1 36.4 51.9 535 62.5 21.5 16.21 42.9 38.7 35.1 48.9 529 100 20.1 18.97 39.3 37.9 29.5 45.3 526 200 18.8 29.32 36.5 32.8 26.2 41 520 250 18 31.85 33.1 30.1 24.3 37.2 515 FREQUENCY RL ATTEN NEXT PSNEXT ELFEXT PSELFEXT DELAY (MHZ) (DB) (DB/100M) (DB/100M) (MHZ) (DB/100M) (DB/100M) (NS/100M) 1 20 3.31 65.1 62.5 64.3 71.7 562 4 23 4 57.2 52.7 53.1 68.2 557 8 23.7 5.2 53.1 49.5 47.8 67.2 550 10 24.5 5.5 52.3 49.1 45.9 67.1 552 16 25 7.33 50.9 47.3 44.2 65.2 549 20 25 8 48.2 44.9 29.8 57.3 542.3 25 24.3 9.5 46.3 42.7 38.6 54.1 540.7 31.3 23.6 10.7 44.1 42.1 36.4 51.9 539.1 62.5 21.5 16.21 42.9 38.7 35.1 48.9 537.9 100 20.1 18.97 39.3 37.9 29.5 45.3 537.8 200 18.8 29.32 36.5 32.8 26.2 41 536.2 250 18 43.7 33.1 30.1 24.3 37.2 536 300 16.2 41.2 31.3 29.9 23.9 35.6 535 400 15.4 38.3 30.9 29.8 22.1 34.7 536 500 14.7 33.7 29.8 28.9 20.9 33.2 535 7 8
Cat3 UTP 25 PAIRS Cable Cat3 UTP 50 Pairs Cable ANSI/TIA-568-B Performance Category = Cat3 Number of Twisted Pairs = 50 Jacket = PVC,LLDPE(outdoor) Cable Configuration = UTP (Unshielded Twisted Pair) ANSI/TIA-568-B Performance Category = Cat 3 Number of Twisted Pairs = 25 Jacket = PVC,LLDPE(outdoor) Cable Configuration = UTP (Unshielded Twisted Pair) 10Base-T, 100Base-T4 10Base-T, 100Base-T4 Cat3 UTP 25 PAIRS Cable Cat3 UTP 50 Pairs Cable FREQ (MHZ) NEXT(dB/100m) Min Value/Typical Value/Standard Value IL(dB/100m) SRL(dB/100m) Min Value/Typical Value/ Standard Value Frequency MHZ Impedance Ω RL db Attenuation db/100m NEXT db/100m 1 43.0/48.0/41.0 2.6 13.0/16.0/12.0 1 12.0 3.4 41.3 4 34.0/38.0/32.0 5.6 13.0/16.0/12.0 4 12.0 5.6 32.5 8 29.0/33.0/26.0 8.5 13.0/16.0/12.0 8 100+/-15 11.6 8.5 27.9 10 28.0/33.0/26.0 9.8 13.0/16.0/12.0 10 11.7 9.7 26.9 16 25.0/30.0/23.0 13.1 11.0/14.0/10.0 16 10.3 13.1 24.3 9 10
Cat5e UTP/FTP Patch Cord: LAN CABLE PATCH CORD Fiber Optic Patch Cord: Category-5e UTP/FTP Cable 4-Pair-easily identified color-striped pairs 24AWG stranded bare copper conductors PVC jacket for indoor use Excellent attenuation and crosstalk characteristics Exceeds EIA/TIA 568 B.2, ISO/IEC 11801 specifications Suitable for 100MHz high speed data applications, Gigabit Ethernet, fast Ethernet and 155Mbps TP-PMD/CDDI LC/UPC-LC/UPC MM OM2 DX 1M ILA1: 0.16dB RLA1: 37.7dB ILA2: 0.09dB RLA2: 36.3dB ILB1: 0.19dB RLB1: 39.1dB ILB2: 0.11dB RLB2: 37.5dB Cat6 UTP/FTP Patch Cord: LC/UPC-LC/UPC MM OM4 DX 1M ILA1: 0.15dB RLA1: 38.0dB ILA2: 0.15dB RLA2: 38.2dB ILB1: 0.20dB RLB1: 35.2dB ILB2: 0.18dB RLB2: 36.2dB High quality Cat.6 Patch cord with cross skeleton frame, pin gold palted RJ45 plug. 250MHZ high speed signal transfer. Category-6 UTP/FTP Cable 4-Pair-easily identified color-striped pairs 23AWG stranded bare copper conductors PVC jacket for indoor use Excellent attenuation and crosstalk characteristics ST/PC SM 9/125 SX 3M Pigtail Exceeds EIA/TIA 568 B.2, ISO/IEC 11801 specifications Suitable for 250MHz high speed data applications, Gigabit Ethernet, fast Ethernet and 155Mbps TP-PMD/CDDI,1000/100/10 BASE-TX ILA1:0.2 db RLA1: 52.5 db 11 12
Composite Cable:2*RG6 Quad Shield CCS with 2*Cat6 RG59 Mini Coax,24AWG,95% Braid PVC Jacket 40% Aluminum 60% Aluminum Braid CCS Conductor Dielectric RG59,a specific type of Coaxial cable,is used for low-power video and radio frequency connections.the RG59 is mostly used for shorter-distance,and for lower frequency signals(50mhz and below).rg59 is a good choice for CCTV video surveillance systems.our Mini 24AWG RG59 offers a higher resistance than the regular RG59.The copper braid shield provides great structural integrity while keeping flexibility and durability.the braid also has lower DC resistance than foil,which is the right fit for minimizing low frequency interference. Cat6 UTP Cable: Category 6 Unshielded Twisted Pair 250MHz Bandwidth for Data Applications 23AWG Solid Copper Conductors Exceeds ANSI/TIA-568-C.2,ISO/IEC 11801 Applications PVC Jacket 95% Braid Conductor Dielectric Mini RG59 24AWG Solid Conductor 75Ohm impedance ISO 9001:2000 CE/RoHS Compliant 1000ft Pull Box RG6 Coaxial Cable: High-Grade RG6 Quad Shield Suitable for Digital HDTV,CATV Composite Cable:RG6 Quad Shielded with Cat5e Cable PVC Jacket 40% Aluminum Braid 60% Aluminum Braid BC Conductor Dielectric RG6 Standard Shield CCS In comparison to its RG59 counterpart,the RG6 has a thicker,lower resistance conductor,giving it the ability to carry data more accurately and with better quality.this makes it the choice cable for satellite signals,broadband internet and home cable.the RG6s typically feature multiple shields to protect the nearby electronics from the powerful electric current that this cable is carrying.our RG6 Standard Shield features an shield and a 60% Aluminum Braid Shield,which reduce EMI. Category 5e Unshielded Twisted Pair Designed for indoor 24AWG Solid Copper Conductors Exceeds ANSI/TIA-568-C.2,ISO/IEC 11801 Applications High-Grade RG6 Coaxial Cable 18AWG Stranded Power Cable RoHS/CE Compliant PVC Jacket 60% Aluminum Braid CCS Conductor Dielectric High-Grade RG6 Coaxial Cable Suitable for Digital HDTV Application,CATV and Digital Satellite Installations. Fully Sweep-Tested to 3000MHz 18AWG Solid Copper-Clad Steel Conductor 60% Aluminum Braid Shield CE/RoHS Compliant Supplied in 1000ft Pull Box 13 14
S o l a r s t a r E L E C Notes: Certificate FLUKE test report 15 16