iworx Sample Lab Experiment AN-13: Crayfish Motor Nerve

Similar documents
Cockroach Cercal Sense Organs

iworx Sample Lab Experiment AM-9: Crayfish Gut Pharmacology

Experiment HM-8: The Electrogastrogram (EGG) and the Growling Stomach

iworx Sample Lab Experiment HM-3: The Electrogastrogram (EGG) and the Growling Stomach

Stimulating Electrodes

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Experiment PP-1: Electroencephalogram (EEG) Activity

Analysis of AP/axon classes and PSP on the basis of AP amplitude

Game Show Physiology

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Experiment BI-1: ECG Signal Conditioning

Overview. Signal Averaged ECG

New Generation of MEA-Systems: MEA2100-System

DektakXT Profilometer. Standard Operating Procedure

Analyzing and Saving a Signal

TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

Supplemental Material for Gamma-band Synchronization in the Macaque Hippocampus and Memory Formation

HST Neural Coding and Perception of Sound. Spring Cochlear Nucleus Unit Classification from Spike Trains. M.

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Lesson 14 BIOFEEDBACK Relaxation and Arousal

User Guide. qeeg NeXus-32. This user guide has been created to educate and inform the reader about doing qeeg measurements with the NeXus-32

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

Multiwell-MEA-System

User Guide EMG. This user guide has been created to educate and inform the reader about doing EMG measurements

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

HV/PHA Adjustment (PB) Part

Activity P27: Speed of Sound in Air (Sound Sensor)

Bionic Elephant Trunk. Assembly Instructions

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

Introduction: Overview. EECE 2510 Circuits and Signals: Biomedical Applications. ECG Circuit 2 Analog Filtering and A/D Conversion

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

The most sensitive microelectrode array system for in vitro extracellular electrophysiology. Mobius Tutorial AMPLIFIER TYPE MED-A64MD1/MED-A64HE1

Introduction to Thermal Stimulator in ABL

User Guide & Reference Manual

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

INSTRUMENTATION ESSENTIALS: DIFFERENTIAL AMPLIFICATION

Bill of Materials: Super Simple Water Level Control PART NO

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Advanced Skills with Oscilloscopes

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Muscle Sensor KI 2 Instructions

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

NENS 230 Assignment #2 Data Import, Manipulation, and Basic Plotting

Getting started with Spike Recorder on PC/Mac/Linux

4125 system setup and deployment quick start guide

TT AFM LongBeach Procedures and Protocols V2.1

ASK THE EXPERTS: Procedure for Verifying Magnetic Pickup Signal Integrity Using a Windrock Portable Analyzer

The BAT WAVE ANALYZER project

3 SLiC Aerial Closure with Rubber End Seal

Data Acquisition Using LabVIEW

Lesson 10 Manual Revision BIOPAC Systems, Inc.

SC24 Magnetic Field Cancelling System

This document describes the different ways to allow the automation system to close a gpi contact from the transmission list.

INTRODUCTION (EE2499_Introduction.doc revised 1/1/18)

OPTICAL POWER METER WITH SMART DETECTOR HEAD

A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

CMOS-MEA5000-System Manual

Lab experience 1: Introduction to LabView

Using EndNote Online: health

SC24 Magnetic Field Cancelling System

NewScope-7A Operating Manual

Revision 1.2d

Standard Operating Procedure of nanoir2-s

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

Activity P32: Variation of Light Intensity (Light Sensor)

SPECIFICATIONS FOR TENDER # A SUPPLY OF ONE COMBINATION EMG/NCS/EP AND EEG SYSTEM FOR WESTERN HEALTH

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Sprite TL Quick Start Guide

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

DIGITAL PORTABLE RECORDER TRAINING MANUAL FOR COURT REPORTING OFFICERs

MY-HITE ADJUSTABLE TABLE

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

LMH0340/LMH0341 SerDes EVK User Guide

WiPry 5x User Manual. 2.4 & 5 GHz Wireless Troubleshooting Dual Band Spectrum Analyzer

Patchmaster. Elektronik. The Pulse generator. February 2013

imac Intel 27" EMC 2546 isight Camera and Microphone Cable Replacement

Mounting a Scintillation Detector

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Crimp & Cleave Termination Instructions for SEL ST Connectors

Metal Electrode Meter

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Agilent N5431A XAUI Electrical Validation Application

Summit Audio Model TLA-50 Tube Leveling Amplifier

CMOS-MEA5000-System Manual

Simple and highly effective technology to communicate your brand s distinctive character

Spectrum Analyser Basics

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

iphone 7 Plus LCD Screen and Digitizer Replacement

MclNTOSH MODEL C-4 and C-4P

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Transcription:

Experiment AN-13: Crayfish Motor Nerve Background The purpose of this experiment is to record the extracellular action potentials of crayfish motor axons. These spontaneously generated action potentials will be recorded using a suction electrode. Crayfish Slow Flexor Muscles The abdomen of the crayfish consists of six segments, each having its own armor plating--a sturdy exoskeleton- -that is hinged to the ones anterior and posterior to it. Inside each segment lies the nervous system and the muscles that control the bending of the hinge between the segments. The segments can move only in one dimension, to curl the tail under the thorax (this is called flexion) or straighten the tail out (extension). These movements are controlled by different sets of muscles: flexors and extensors. Fast movements, such as the tail flip used to escape from predators, is controlled by a massive set of muscle fibers whose contractions are very fast; these are the fast flexor muscles. The slower, postural adjustments that crayfish use to balance themselves are controlled by a smaller sheet of more slowly contracting muscle fibers; these are the slow flexor muscles. These slow flexors are located just inside the exoskeleton on the ventral surface, very close to the ventral nerve cord. The superficial flexor is innervated by the superficial branch of Nerve 3 (SBIII). This nerve contains six motor neurons. Because these neurons differ in size, the amplitudes of the extracellular spikes correspond to the different diameters of the six axons. If these action potentials were recorded intracellularly, they would all be of a very similar amplitude. When recorded extracellularly, a larger axon will produce a larger extracellular spike, because it has a greater surface area for current to leak across than a smaller axon, which produces a smaller amplitude extracellular spike. Because of this aspect of extracellular recording, it is possible to sort the spikes by amplitude and assign them to individual axons. The differential activity of the various axons in the nerve can therefore be determined by the relative frequency of their extracellular spikes. Equipment Required PC or Macintosh computer IXTA, USB cable, IXTA power supply IX-B3G recording cable Suction electrode assembly and glass tips (See Appendix II for construction instructions and a commercial alternative) Micromanipulator with base Faraday cage (if necessary) Preparation dish Cold crayfish saline (See Appendix) Dissection microscope and light source Dissection tools Bath ground electrode with cable Disposable plastic transfer pipets AN-13-1

Start the Software 1. Click on LabScribe 2. Click Settings Animal Nerve CrayfishMotorNerve 3. Once the settings file has been loaded, click the Experiment button on the toolbar to open any of the following documents: Equipment Setup Appendix Background Labs Setup (opens automatically) 1. Locate the iwire-b3g recording cable (Figure AN-13-S1) in the iworx kit. 2. Insert the connector on the end of the recording cable into the isolated inputs of the iwire 1 channel on the front of the IXTA. Figure AN-13-S1: The iwire-b3g recording cable. Connect the iwire-b3g prior to turning on the IXTA. This experiment uses a suction electrode and the B3G. 1. Attach the three connectors of the suction electrode assembly to the B3G so that: the recording electrode, which is the wire inside the lumen of the suction tubing, is connected to the red (+) connector. the indifferent (reference) electrode, which is the wire wrapped around the suction tubing down to the glass microelectrode tip, is connected to the black (-) connector. AN-13-2

the ground electrode, that is in the solution in the bath chamber, is connected to the green connector. 2. Place the barrel of the suction electrode on a micromanipulator placed close to the crayfish preparation dish. Note: The default filter settings listed are suggested for use in ideal recording conditions. If noise is present in the recording environment, the high and low pass filters can be set at different levels to create a recording with less noise. If noise is caused by AC line voltage used to power the equipment in the lab, a digital notch filter (as described in the Electrical Noise section)can be used. Note: If electrical noise is an issue, please see Appendix. The Dissection 1. To anesthetize it, bury a crayfish in ice for 10 minutes. 2. Separate the abdomen (the tail ) from the thorax. 3. Securely pin the abdomen dorsal side down in the dish's wax or Sylgard. Cover the preparation with cold crayfish saline. Cut off the swimmerets which are the paired appendages on the ventral surface of each segment. The movements of the swimmerets interfere with the recording process if they are not removed. 4. Choose one of the middle segments to dissect. Use a scalpel to make a shallow incision along the anterior sternite (the ribs that separate the segments). Cut all the way through the membrane but avoid cutting too deep and damaging the underlying nerve cord and muscles. 5. Use fine forceps to lift up the membrane and make a midline incision extending for the anterior half of the segment. Lift the corner on one side and use small scissors to cut a small piece of the membrane off. This will expose the ventral nerve cord, including the ganglion and the three nerves (I, II, and III) coming out of each side. Identify the superficial branch of the third nerve (SBIII) which extends to the superficial flexor. 6. In this experiment, you will be attaching a suction electrode to the superficial branch of Nerve 3 and recording the spontaneous and stimulated extracellular action potentials from the six motor neurons contained in the nerve. Exercise 1: Action Potentials in Motor Neurons Aim: To record motor nerve extracellular action potentials from the SBIII nerve and sort them by size. Approximate Time: 30 minutes Procedure 1. Use the manipulator to position the tip of the suction electrode near the exposed section of the SBIII nerve. AN-13-3

2. Check the size of the tip of the suction electrode. It should be the same size or only slightly larger than the diameter of the nerve. 3. Without moving the tubing, pull back on the plunger of the syringe that is connected to the tubing of the suction electrode, to pull a loop of the nerve into the suction electrode. 4. Type Motor Neurons Spontaneous Activity in the Mark box to the right of the Mark button. 5. Click Record to begin recording and click the mark button to mark the recording. A sample of this recording can be seen in Figure AN-13-L1. 6. To improve the display of the action potentials in the SBIII nerve on the Main window, Autoscale the recording. 7. If only two or three different types of action potentials are detected, use a suction electrode with a tighter fit or record from a different SBIII nerve. 8. Continue to record for two minutes. 9. Click Stop to halt recording. 10. Type Motor Neurons Posterior Hairs Stimulated in the Mark box to the right of the Mark button. 11. Click Record to begin recording and click the mark button to mark the recording. 12. Brush the sensory hairs on the posterior end of the tail fins. 13. Continue to record for two minutes. 14. Click Stop to halt recording. 15. Stimulating one of the swimmeret stumps or other sensory hairs visible at the edges of the abdomen may also alter the activity. Mark the recording appropriately and repeat the recording process for as many specific manual stimulations as desired. 16. Select Save in the File menu. AN-13-4

Figure AN-13-L1: A section of the SBIII nerve recording displayed in the Main window. Data Analysis 1. LabScribe will find all the spikes within the tolerance limits and isolate them in the Template Match channel. Compare the newly created spikes on the Template Match channel to the recording in the SBIII channel. If it seems to have caught most of the spikes of that size class, proceed to the next step. If it caught too few, click on the word Template in the channel menu and choose Setup Function. Increase the Tolerance number and check again. Repeat until most of the similar amplitude spikes are matched. If thetemplate Match caught too many, reduce the Tolerance number until only the correct spikes are matched. 2. Once you have a good match, you can perform steps 2-4 for each of the different size spikes. This will add a channel for each size spike. 3. It is now possible to determine the frequency of the spikes in each of the size classes. To do this, choose the first Template channel and click its add function button. Choose Periodic > Frequency. Adjust the Threshold lines to capture the spikes. Click OK, and you will be able to use the Frequency channel to determine the frequency of that size spike in any section of the data. AN-13-5

Figure AN-13-L2: A section of the SBIII nerve recording with two Template Match channels displaying two sorted spike sizes and the two corresponding spike frequency channels. 4. Click on the Analysis button in the Main Toolbar. Click Add Function > General > Mean. Choose any section of data by placing the cursors around it. The function window on the frequency channel will read the mean frequency of the spikes of that size in the selected section. 5. Repeat Steps 6 and 7 for each of the Template channels. 6. Enter the values in the Frequency column of Table AN-13-L1. 7. Other parameters of the spikes can also be determined. Use these parameters to distinguish the different classes of action potentials recorded in the spontaneous activity from the SBIII nerve: Amplitude (Amp): Measure the amplitude of an action potential by placing one cursor on the baseline before the action potential, and the second cursor on the peak of the potential. The value for the V2-V1 function on the Nerve Action Potential channel is the amplitude. Duration (Dur): Measure the duration of an action potential by placing one cursor at the onset of the action potential, and the second cursor on the point where the potential returns to the baseline. The value for the T2-T1 function on the Nerve Action Potential channel is the duration. Polarity (Pol.): note whether the waveform of the action potentials goes up (positive) or down (negative) on the screen. 8. Enter information about the types of action potentials recorded in the Journal and Table AN-12- L1. AN-13-6

9. Determine the overall frequency of spikes and the frequencies of each size spike in the different manual stimulation conditions and enter those values into Table AN-13-L2. Table AN-13-L1: Properties of Action Potentials Recorded from SBIII Nerve. 1 2 3 4 5 6 AP Type Amp. (mv) Dur. (msec) Pol.(+, -) Table AN-13-L2: Properties of Action Potentials Recorded from SBIII Nerve. 1 2 3 4 5 6 AP Type Overall Questions Spontaneous Stim Cond 1 Stim Cond 2 Stim Cond 3 Stim Cond 4 1. How many different types of extracellular action potentials did you detect? 2. What membrane properties affect the shape and size of action potentials? 3. If recorded intracellularly, all action potentials would be of a very similar amplitude. Why do extracellularly recorded action potentials vary in amplitude? AN-13-7

4. There are six neurons present in the nerve. You may have seen less than six classes of spikes. Why might this be the case? 5. Did the different types of spikes differ in their frequency response to manual stimulation of sensory hairs or swimmeret stumps? AN-13-8