The Versatility in Vibration Measurement Datasheet

Similar documents
PSV-500 Scanning Vibrometer Full-fieldVibrationMeasurement Datasheet. PSV-500 Scanning Vibrometer

MPV-800 Multipoint Vibrometer Synchronous Optical Vibrometry Datasheet. MPV-800 Multipoint Vibrometer

MSV-400 Microscope Scanning Vibrometer

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

Digital SWIR Scanning Laser Doppler Vibrometer

Digital SWIR Scanning Laser Doppler Vibrometer

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Scanning System S-2100

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S DDF200M Digital Direction Finder Specifications

Signal Stability Analyser

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

R&S HF907DC SHF Downconverter Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

R&S RT-Zxx High-Bandwidth Probes Specifications

CBF500 High resolution Streak camera

R&S ZVA110 Vector Network Analyzer Specifications

Agilent 81600B Tunable Laser Source Family

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S ZN-Z154 Calibration Unit Specifications

LONWORKS Fibre Optic Converter

R&S ZN-Z85 Switch Matrix Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

3500/42E Vibration Monitor

R&S GU221 Filter Control Unit Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Multiple Band Outdoor Block Up- and Downconverters

Driver circuit for CMOS linear image sensor

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

More Precision. capancdt // Capacitive displacement sensors and systems

Microwave Counter, Power Meter and DVM in One Portable Package

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

MULTIBAND 1/3 RACK-MOUNTED

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Peak sensitivity wavelength λp (nm) Photosensitive area (mm)

HP 70950B OPTICAL SPECTRUM ANALYZER

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

DA E: Series of Narrowband or Wideband Distribution Amplifiers

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram

R&S AVG050 DVB Satellite Receiver Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Fiber-optic Video Format Converters DATA SHEET

OSICS 8-Channel Modular Platform for DWDM Testing

Magnetic Sensor - Incremental EHP

Displacement Measuring System for Cylinder Series OSP-P

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

Full-featured CW Microwave Counters for Field, Factory or Lab

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

APD modules. Operates an APD with single 5 V supply (standard type, short-wavelength type) C12702 series.

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

R&S RT-Zxx Standard Probes Specifications

R&S EDS300 DME/Pulse Analyzer Specifications

GFT Channel Digital Delay Generator

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

LAUREL ELECTRONICS, INC.

Fibre Optic Modem ODW-611

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

R&S DST200 RF Diagnostic Chamber Specifications

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

Driver circuit for MPPC

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

1/3 RACK-MOUNTED BLOCK CONVERTERS

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

R&S ZND Vector Network Analyzer Specifications

1 Gang-sized Multi-format video to Optical DVI Converter, MVDF DATA SHEET

RF Semiconductor Test AXRF RF Port Upgrade Kits

Fibre optic router for TP/FT-10 LRW-112PP

Multi Application Test System

Agilent 87405C 100 MHz to 18 GHz Preamplifier

High Performance Outdoor Test Translators

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

R&S FPC1000 Spectrum Analyzer Specifications

Photosensitive area (mm) 4 4. Peak sensitivity wavelength (nm) Supply voltage Dark state. Max. Vcc max. Tstg Min. Max. (ma) (V)

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

IMPAC Infrared Thermometers

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Transcription:

OFV-5000 Vibrometer Controller The OFV-5000 Controller is the core of Polytec s latest state-of-the-art laser vibrometer systems. Its modular design allows the frequency, velocity and displacement capabilities to be tailored to your applications. Both analog and digital decoders are available, giving a frequency from near DC to 4 MHz, with veloci ties up to ±0 and displacements from the picometer to meter. In combination with an interferometric sensor head OFV-505 for highest signal quality, OFV-534 compact sensor head or OFV-55/55 fiber-optic sensor heads, the OFV Modular Vibrometer is an ultra-precise workhorse for non-contact vibration measurement. Highlights Measure displacement and velocity in real-time High resolution and bandwidth Flexible and expandable with several sensor heads and decoders Simple and comfortable operation with touchscreen and remote control OFV-5000 Vibrometer Controller The Versatility in Vibration Datasheet

Technical Data Metrological Specifications Analog signal outputs BNC, ±0 V : Velocity signal Displacement signal AUX output DSP output (velocity with DSP filter) Digital signal output 3 velocity 3 Filters Tracking filter Adaptive filter module LF-0 Signal level S/P-DIF standard 4 bit 48/96 ksa/s DC to 4 MHz ±0 High pass filter: 00 Hz, off Low pass filter: 5 khz, 0 khz, 00 khz, off 3 settings: slow, fast, off DSP based: suppresses statistic noise, analog and digital signal output, frequency 0... 0 khz (optional for decoder VD-06) Bargraph on touchscreen Output as DC voltage signal (BNC, 0... 5 V) PC-Interface RS-3, Remote control of the instrument settings Depends on decoder configuration. Velocity or displacement signal, depends on decoder configuration (see page 3). 3 Notice: frequency, max. velocity and measurement depend on decoder configuration (see page 3). Sensor Head Compatibility Sensor heads Compact sensor head Fiber optic sensor heads OFV-505, OFV-503 OFV-534 OFV-55, OFV-55 General Specifications Interface/Display Dimensions Weight Protection class Operating temperature Storage temperature Relative humidity Power supply Power consumption 7" color touchscreen with interactive menu guidance 9" rack mounting, W x D x H: 450 x 360 x 50 mm (9", 84 HP/3U) without angle brackets 0 kg IP0 +5 C +40 C (4 F... 04 F) -0 C +65 C (4 F... 49 F) max. 80%, non-condensing 00...40 VAC ±0%, 50/60 Hz max. 00 VA

System Configuration Different analog and digital decoders ensure that the OFV-5000 Vibrometer Controller fits perfectly to your application. With a combination of up to four decoders the Modular Vibrometer system shows its high flexibility. Therefore the OFV-5000 contains four slots: two for velocity decoders, one for the displacement decoder and one additional auxiliary slot for a velocity or a displacement decoder. Velocity Decoders Decoder Description No. of s Typical resolution velocity VD-0 VD-05 VD-06 VD-08 Analog, broadband universal decoder Analog decoder for ultrasonic applications Digital high-precision velocity decoder Digital high-precision velocity decoder 4 0. µ 0 0.5 Hz -.5 MHz < 3 µ.5 0.5 Hz - 0 MHz 4 0.0 µ 0.5 0 Hz - 350 khz 8 0.005 µ 0.5 0 Hz - 5 khz VD-09 Digital velocity decoder 4 0.0 µ 0 0 Hz -.5 MHz Noise-limited resolution in the smallest measurement. The noise-limited resolution is defined as the signal amplitude (RMS) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). In combination with DD-500 only specific measurement s of the VD-08 can be used. Displacement Decoders Decoder Description No. of s Resolution displacement DD-300 DD-500 DD-600 DD-900 Analog displacement decoder for ultrasonic applications Digital high-end displacement decoder 6-bit-DSP (requires VD-06) I&Q converter for data processing with VibSoft VDD Broadband digital displacement decoder (requires VD-09) 0.05 pm ±75 nm 30 khz - 4 MHz 6 0.05 pm ±50 mm 0 Hz - 350 khz 0. pm 0-5 MHz 6 0.5 pm ±50 mm 0 Hz -.5 MHz Noise-limited resolution in the smallest measurement. The noise-limited resolution is defined as the signal amplitude (RMS) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). I&Q converter delivering I and Q raw phase signals up to 5 MHz for velocities up to.5 for highest displacement resolution. With the PC-based system VibSoft-VDD Data Analysis, frequencies up to MHz and velocities up to 0.8 can be achieved. 3

Possible configuration of the slots Slot Measurand Possible decoders Slot Velocity VD-0, VD-09 Slot Velocity VD-06, VD-08 Slot 3 Displacement DD-500, DD-600, DD-900 Slot 4 Velocity or displacement VD-05, DD-300 Every slot contains one decoder. Not all combinations are possible. Ask your Polytec sales engineer. Recommended Decoder Combinations The following table lists recommended decoder combinations for representative applications. The concept of the OFV Modular Vibrometer System accepts further decoders allowing to study even complex vibration phenomena. If you have specific requirements, please contact Polytec s application and sales engineers who will help to choose the appropriate sensor heads, decoders and VibSoft software. Velocity decoder VD-09 Displacement decoder Applications Acquisition of vibrations at frequencies from DC up to.5 MHz at high resolution and velocity. For ultrasonics and microstructures. VD-09 DD-900 Additional direct displacement output with picometer resolution. Suitable for measurement of signals with DC components like switches or transient behaviour. VD-09 VD-06 DD-900 Same as the combination VD-09 + DD-900, but with additional high-precision measurement of velocities up to 0.5 at frequencies up to 350 khz. VD-06 DD-500 Digital, high-precision measurement of velocity and displacement at frequencies up to 350 khz with a velocity limited to 0.5. For demanding applications e.g. acoustics, microsystems, precision mechanics. VD-0 VD-06 VD-0 VD-05 DD-500 Same as the combination VD-06 + DD-500, but vibration frequency extended up to.5 MHz and velocity extended up to 0. of velocity at high frequencies up to 0 MHz. For high-frequency applications like ultrasonics and microsystems. VD-0 DD-300 Acquisition of vibrations at frequencies up to 4 MHz. For high-frequency applications like ultrasonics and micro systems. 4

Velocity Decoders VD-0 (peak) Typical resolution acceleration linearity error m/v µm s - / Hz g % 5 0.05 0. 0.5 Hz - 0.5 khz 8,000.0 5 0.5 0.5 0.5 Hz -.5 MHz 40,000.5 5.5 0.6 0.5 Hz -.5 MHz,00,000.0,000 0.5 0.5 Hz -.5 MHz 9,600,000.0 The full scale values correspond to the maximum output voltage of 0 V peak. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). The typical value refers to the center of the operating frequency. V peak 0,5 50 m 00 m 50 m 0 m,000 m/v 5 m/v 5 m/v 5 m/v Ranges Detectable Acceleration: 9,600,000 g Multi-purpose decoder for a wide of applications Large frequency bandwidth and velocity up to 0 Analog decoding for minimum signal delay m 00 µ 0 µ µ Lower Limit: 0.5 Hz Vibrational :.5 MHz Min. Detectable Velocity: 0. µ 0. Hz 0.5 Hz Hz 0 Hz 00 Hz khz 0 khz 00 khz 50 khz MHz.5 MHz 0 MHz 5

VD-05 (peak) Resolution acceleration linearity error m/v µm s - / Hz g % 00 0.5 < 3 0.5 Hz - 0 MHz 30,000 500.5 < 3 0.5 Hz - 0 MHz,600,000 The full scale values correspond to the nominal output voltage of 5 V peak. The up to 6 V peak can be used at reduced linearity specifications. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). The attainable resolution is frequency-dependent. V peak 0 Detectable Acceleration:,600,000 g Precise decoding of highest frequencies up to 0 MHz Analog decoding for minimum signal delay For applications in the higher ultrasonic frequency and for fast transient and pulse shaped motions Perfectly suited also for MEMS (micro electro mechanical systems),5 500 m 00 m 0 m m 00 µ 0 µ µ Lower Limit: 0.5 Hz 500 m/v 00 m/v Ranges Min. Detectable Velocity: < 3 µ Vibrational : 0 MHz 0. Hz 0.5 Hz Hz 0 Hz 00 Hz khz 0 khz 00 khz MHz 0 MHz VD-06 (peak) Typical resolution 3 acceleration linearity error m/v µm s - / Hz khz g % 0.0 0.0 0-0 8 0. 0.0 0.05 0-350 4,500 0. 0 0.0 0.05 0-350,000 0. 50 0.50 0.06 0-350 0,000 0. s, 0 and 50 m/v each feature an additional low pass with 00 khz frequency, higher resolution but reduced max. acceleration. The full scale values correspond to the maximum output voltage of 0 V peak. 3 The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). The attainable resolution is frequency-dependent. The typical value refers to the center of the operating frequency. V peak 0 Detectable Acceleration: 0,000 g Digital velocity decoder with outstanding resolution covering a wide frequency up to 350 khz Very low noise 500 m 00 m 0 m 0 m 50 m/v 0 m/v m/v m/v Ranges True DC capability Outstanding linearity and frequency response m 00 µ 0 µ µ Lower Limit: 0 Hz Min. Detectable Velocity: 0.0 µ Vibrational : 350 khz 6 0. Hz Hz 0 Hz 00 Hz khz 0 khz 0 khz 00 khz 350 khz MHz

VD-08 (peak) Typical resolution 3 acceleration linearity error m/v µm s - / Hz khz g % 0. 0.00 0.005 0-5 6.4 0. 0.5 0.005 0.005 0-5 6 0. 0.0 0.0 0-0 64 0. 0.0 0.0 0-0 56 0. 5 0.05 0.0 0-0 640 0. 0 0. 0.0 0-0,80 0. 0 0. 0.03 0-5 3,00 0. 50 0.5 0.05 0-5 8,000 0. In combination with DD-500 only specific measurement s of the VD-08 can be used. The full scale values correspond to the maximum output voltage of 0 V peak. 3 The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). The attainable resolution is frequency-dependent. The typical value refers to the center of the operating frequency. V peak 0 500 m 00 m 00 m 50 m 0 m 0 m 5 m m m 00 µ 0 µ µ Lower Limit: 0 Hz 50 m/v 0 m/v 0 m/v 5 m/v m/v m/v 0.5 m/v 0. m/v Ranges Vibrational : 5 khz Detectable Acceleration: 8,000 g Digital velocity decoder dedicated to low frequencies up to 5 khz with highest resolution Highest optical sensitivity for measurement on dark surfaces True DC capability Outstanding linearity and frequency response Min. Detectable Velocity: 0.005 µ 0. Hz Hz 0 Hz 00 Hz khz 5 khz 0 khz 0 khz 5 khz 00 khz MHz 7

VD-09 (peak) Typical resolution 3 acceleration linearity error m/v µm s - / Hz MHz g % 5 0.05 0.0 0-0. 3,00 0.5 0 0. 0.04 0-0.5 6,000 0.5 0 0. 0. 0-8,000 0.5 50 0.5 0.8 0 -.5 480,000 0.5 00 0. 0 -.5 960,000 0.5 00 0.5 0 -.5 3,00,000 0.5 500 5 0.6 0 -.5 8,000,000 0.5,000 0 0.7 0 -.5 9,600,000 0.5 s 0...,000 m/v each feature an additional low pass with 50 khz frequency, higher resolution but reduced max. acceleration. The full scale values correspond to the maximum output voltage of 0 V peak. 3 The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). The attainable resolution is frequency-dependent. The typical value refers to the center of the operating frequency. V peak Multi-purpose high frequency bandwidth digital decoder with high precision and high resolution True DC capability Well balanced properties regarding bandwidth, resolution and velocity limits make it the decoder of choice for most measurement applications 0 5 500 m 00 m 00 m 50 m 0 m m 00 µ 0 µ µ Lower Limit: 0 Hz /V 500 m/v 00 m/v 00 m/v 50 m/v 0 m/v 0 m/v 5 m/v Ranges Min. Detectable Velocity: 0.0 µ Detectable Acceleration: 9,600,000 g Vibrational :.5 MHz 0. Hz Hz 0 Hz 00 Hz khz 0 khz 00 khz 50 khz MHz.5 MHz.5 MHz 8

Displacement Decoders DD-300 (peak) Resolution velocity nm/v nm pm/ Hz khz 50 ±75 < 0.0 pm/ Hz at 00% reflectivity < 0.05 pm/ Hz when measuring on reflective film 30-4,000 ( 3dB) 6 The full scale value corresponds to the output voltage swing of ±.5 V at load resistance 50 Ω. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution. Amplitude (peak) µm 00 nm 75 nm 0 nm nm 00 pm 0 pm pm < 0,05 pm khz Displacement: 75 nm 0 khz Lower Limit: 30 khz 30 khz 00 khz MHz 0 MHz Velocity: 6 4 MHz : 4 MHz 00 MHz Displacement decoder for measuring smallest motions up to 75 nm with a large frequency bandwidth from 30 khz up to 4 MHz For measurements on ultrasonic transducers, detection of ultrasonic pulses and to observe fast transient motions of MEMS devices Special high-pass filter suppresses low frequency (acoustic) vibrations and allows the detection of smallest high-frequency vibrations even under noisy ambient conditions Additional MHz low-pass filter improves resolution performance in lower frequency 9

DD-500 Required velocity decoder: VD-06 (peak-to-peak) Resolution 3 velocity µm/v µm nm khz 0.05 0.05 0-350 0.5 0. 0.03 0-350 0.5 0. 4 0.06 0-350 0.5 0.5 0 0.5 0-350 0.5 0 0.3 0-350 0.5 40 0.6 0-350 0.5 5 00.5 0-350 0.5 0 00 3 0-350 0.5 0 400 6 0-350 0.5 50,000 5 0-350 0.5 00,000 30 0-350 0.5 00 4,000 60 0-350 0.5 500 0,000 50 0-350 0.5,000 0,000 300 0-350 0.5,000 40,000 600 0-350 0.5 5,000 00,000,500 0-350 0.5 The full scale values correspond to ±0 V (peak-to-peak) maximum output voltage. The resolution corresponds to the quantization step of approx. 0.4 mv at the analog output. Noise-limited resolution: < 0.5 pm/ Hz. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). 3 When a suitable measurement has been selected for the digital velocity decoder. Amplitude (peak) Best resolution displacement decoding in conjunction with VD-06 for velocities up to 0.5 For demanding applications in acoustics, micro systems and precision mechanics Analog output as well as digital data stream in S/P-DIF format 00 mm 50 mm 0 mm 0 mm 5 mm mm mm 500 µm 00 µm 00 µm 50 µm 0 µm 0 µm 5 µm Displacement: 50 mm 0 m/v m/v 50 m/v µm µm 500 nm 00 nm 0 nm Lower Limit: 0 Hz m/v : 350 khz Hz 0 Hz 00 Hz khz 0 khz 0 khz 00 khz 350 khz MHz 0 MHz 0

DD-600 Detects even smallest displacements thanks to very good SNR Perfect for MEMS analysis or calibration purposes I&Q converter delivering I and Q raw phase signals up to 5 MHz for velocities up to.5 Highest displacement resolution. With VibSoft-VDD Data Analysis up to MHz and velocities up to 0.8 DD-900 Required velocity decoder: VD-09 (peak-to-peak) Resolution 3 velocity µm/v µm nm khz 0.05 0.05 0 -,500 0 0. 0.03 0 -,500 0 0. 4 0.06 0 -,500 0 0.5 0 0.5 0 -,500 0 0 0.3 0 -,500 0 40 0.6 0 -,500 0 5 00.5 0 -,500 0 0 00 3 0 -,500 0 0 400 6 0 -,500 0 50,000 5 0 -,500 0 00,000 30 0 -,500 0 00 4,000 60 0 -,500 0 500 0,000 50 0 -,500 0,000 0,000 300 0 -,500 0,000 40,000 600 0 -,500 0 5,000 00,000,500 0 -,500 0 The full scale values correspond to ±0 V (peak-to-peak) maximum output voltage. The resolution corresponds to the quantization step of approx. 0.3 mv at the analog output. Noise-limited resolution: < 0.5 pm/ Hz. The noise-limited resolution is defined as the signal amplitude (rms) at which the signal-to-noise ratio is 0 db with Hz spectral resolution, measured on 3M Scotchlite Tape (reflective film). 3 When a suitable measurement has been selected for the digital velocity decoder. Amplitude (peak) 00 mm 50 mm 0 mm 0 mm 5 mm Displacement: 50 mm Broadband displacement decoder up to.5 MHz mm mm 500 µm 00 µm 00 µm 50 µm 0 µm 0 µm 5 µm µm /V 500 m/v 00 m/v 00 m/v 50 m/v 0 m/v 0 m/v 5 m/v Supplements VD-09 velocity decoder for high precision displacement measurements with resolutions down to 5 pm 6 measurement s µm 500 nm 00 nm 0 nm Lower Limit: 0 Hz :.5 MHz Hz 0 Hz 00 Hz khz 0 khz 00 khz 50 khz MHz.5 MHz.5 MHz 0 MHz

Compliance with Standards Laser safety IEC 6085-:04 / EN 6085-:04 / DIN EN 6085-:008-05 (Safety of Laser Products, complies to US CFR 040.0 and 040. except for deviations pursuant to Laser Notice no. 50, dated 4 June 007) Electrical safety IEC 600-:00 + Cor.:0 / EN 600-:00 / DIN EN 600-:0-07 (Safety requirements for electrical equipment for measurement, control, and laboratory use) EMC IEC 636-:0 / EN 636-:03 / DIN EN 636-:03-07 (EMC requirements on Emission and Immunity Electrical equipment for measurement, control, and laboratory use) Emission: Limit Class B IEC/EN 6000-3- and 6000-3-3 Immunity: IEC/EN 6000-4- to 6000-4-6 and IEC/EN 6000-4- OM_DS_OFV-5000_E_ 4346 06/04 - Technical specifications are subject to change without notice. Polytec GmbH (Germany) Polytec-Platz -7 76337 Waldbronn Tel. +49 743 604-0 info@polytec.de Polytec GmbH (Germany) Vertriebs- und Beratungsbüro Schwarzschildstraße 489 Berlin Tel. +49 30 639-540 Polytec, Inc. (USA) North American Headquarters 6400 Bake Parkway Suites 50 & 00 Irvine, CA 968 Tel. + 949 943-3033 info@polytec.com Central Office 046 Baker Road Dexter, MI 4830 Tel. + 734 53-948 East Coast Office Cabot Road Suites 0 & 0 Hudson, MA 0749 Tel. + 508 47-040 Polytec Ltd. (Great Britain) Lambda House Batford Mill Harpenden, Herts AL5 5BZ Tel. +44 58 7670 info@polytec-ltd.co.uk Polytec France S.A.S. Technosud II Bâtiment A 99, Rue Pierre Semard 930 Châtillon Tel. +33 496569-00 info@polytec.fr Polytec Japan Arena Tower, 3th floor 3--9, Shinyokohama Kohoku-ku, Yokohama-shi Kanagawa -0033 Tel. +8 45 478-6980 info@polytec.co.jp Polytec South-East Asia Pte Ltd Blk 400 Ang Mo Kio Ave 0 #06-06 TechPlace Singapore 56966 Tel. +65 6450886 info@polytec-sea.com Polytec China Ltd. Room 06, Hanwei Plaza No. 7 Guanghua Road Chaoyang District 00004 Beijing Tel. +86 0 656859 info-cn@polytec.com www.polytec.com