Section C Recorders. DPR mm Digital Strip Chart Recorder

Similar documents
Pen and Multichannel Recorder: Digital Display

DPR100 C/D Pen and Multichannel Recorder: Digital Display

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Micro-DCI 53ML5100 Manual Loader

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Modular Lube Lubrication Systems System Controls

263 Series LED Bargraph Indicator and Controllers

Model KT 115 Cooling incubators with thermoelectric cooling

SCALE & WEIGHT DISPLAYS

LAUREL ELECTRONICS, INC.

SAL Series Wireless Clock (V1)

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KT 53 Cooling incubators with thermoelectric cooling

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Model KBF 115 Constant climate chambers with large temperature / humidity range

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Microwave Counter, Power Meter and DVM in One Portable Package

TELEDYNE HASTINGS INSTRUMENTS

Hybrid Chart Recorder 250 mm (10")

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Magnetic Stirrers Magnetic Stirr

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Wall-/Pipe-Mount Level Indicator

49 inch Full HD 3.5mm Ultra- Narrow Bezel 24/7 Tiling Support with DisplayPort or DVI video wall Commercial Display CDX4952 Ultra-narrow Bezel

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DM 50 / DM / 2- component dosing and mixing system. engineering

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Product Data Sheet 4656 EZ

DCP100 Digital Control Programmer Specifications

Product Data Sheet 8506 VW-691

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

SPECIFICATION NO NOTE

Sapling Wired System. The Sapling Company, Inc Republic Road Huntingdon Valley, PA P F

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

FLOMAT Electromagnetic Insertion Flowmeter

CORONA & PLASMA FOR NARROW WEB

SAPLING WIRED SYSTEM

Application Note 11 - Totalization

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Product Data Sheet 4656 ZW

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Sapling Wired System. Synchronized Clock Systems

ZEBRA SE960HP OEM MINIATURE HIGH PERFORMANCE 1-D SCAN ENGINE. FEATURES Large working range from near contact to 100 in./254 cm. Small and lightweight

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Model KBF 720 Constant climate chambers with large temperature / humidity range

Forced Convection Laboratory Ovens

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

Process Transmitter RMA 422

7.5ft Outdoor Double-Sided Interactive LCD Sign, Transit Center Kiosk Model: NISDK-550PCT, 55 Double-Sided

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

SQM40/41 Actuators for air and gas dampers

P XGA TFT Monitor. User s Manual

CORONA & PLASMA FOR NARROW WEB

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Hitachi Kokusai Electric Comark LLC

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

ENC - LKE51 - L I B

Label Applicator HERMA 400

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Agilent High Capacity RV Pumps & Roots Pumping Systems

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Series CT7N Bimetallic Overload Relays

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy) HP L5006tm 15-inch LCD Touchscreen Monitor

LARGE DIGITAL TEMPERATURE LED DISPLAYS

MICROPROCESSOR CALCULATION MODULE - S2000

Truck router (3Gbps/HD/SD/ASI)

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

Synthesized Block Up- and Downconverter

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

Prisma Optical Networks Ancillary Modules

PRODUCT SPEC SHEET ZEBRA SE96X

Ekasbiz. Stordisplay.no. Teknologi

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

Product Data Sheet 4650 N-465

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Advanced Test Equipment Rentals ATEC (2832)

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Model KT 170 Cooling incubators with thermoelectric cooling

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Multifunction devices

COMMANDER SR100A & SR100B

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA

32" Full HD Large Format LED Display, Ideal for Commercial Use CDE3200-L

Fibre Optic Modem ODW-611

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Transcription:

91-00-01-01 Section C Recorders Contents Product Type Literature No. Overview 40-00-02-02 LeaderLine PC Software 51-52-03-16 SCF Software Configuration Tool 51-52-03-26 SDA Software Data Analysis Tool 43-DR-03-12 43 Strip Chart Recorders (Digital) DPR 100 A/B 0I-6030 DPR 100 C/D Pen and Multipoint 100mm Digital Recorders 0I-6021 DPR 100 G/H EN0I-7449 VRX100 Video Recorder 43-DR-03-10 VRX150 Video Recorder 43-DR-03-13 DPR180 180mm Recorder 43-DR-03-11 DPR250 250mm Digital Strip Chart Recorder 43-DR-03-09 Model DPR 3000 43-DR-03-05 DPR 100 A/B 43-DR-16-09 DPR 100 C/D 43-DR-16-11 DPR 100 G/H 43-DR-16-17 VRX100 43-DR-16-20 VRX150 43-DR-16-22 DPR180 43-DR-16-16 DPR250 43-DR-16-19 DPR 3000 43-DR-16-07 44 Circular Chart Recorders (Digital) DR 4300 44-01-03-04 DR 4500A Truline Recorder 44-45-03-14 DR45AW Truline 44-45-03-11 DR45AR Truline 44-45-03-12 DR4500A Truline HTST & Pasteurization Flow (DR45AP) 44-45-03-16 DR 4500A Classic Recorder 44-45-03-15 DR 4300 44-01-16-04 DR 4500A Classic and DR4500A Truline Recorder 44-45-16-07 46 Circular Chart Recorders (Analog) Model 61 Relative Humidity and Temperature Recorders 46-61-58-01 Model 61 Relative Humidity and Temperature Recorders 45-61-16-01

Recorders Circular Chart and Strip Chart Overview Honeywell s line of recorders are engineered to offer customers maximum performance for minimum investment. All our recorders feature Honeywell quality, assured by a rocksolid warranty program and a customer support second to none. Honeywell offers a variety of recorders to apply to your process for accurate measurement and control. Circular Chart recorders, in general, are preferred for batch processes. The circular chart record displays the entire batch operation over a specific unit of time, from one hour to 31 days. An additional advantage of the circular chart record is easy filing and copying for reference. Compared to the strip chart record, the circular chart has a shorter calibrated chart width. Strip Chart recorders are most commonly chosen for continuous processes where the chart record allows the operator to quickly detect out-of-tolerance deviations over a longterm trend. The long length of the strip chart allows recorders to run unattended for long periods without the necessity for chart replacement. Video recorders provide new methods of monitoring various processes and recording the data electronically. This allows for local viewing of the process data and easy analysis of the data using a personal computer and various software tools. Typical Applications Honeywell recorders are reliable, accurate and require very little maintenance. They are in daily use by thousands of plants on a variety of processes and processing equipment. Oil refineries Chemical plants Pharmaceutical manufacturing Foundries Auto plants Heat treat furnaces Environmental chambers Research and test facilities Pipeline stations Food processing plants Boiler houses Steel mills Glass plants Water and waste treatment Aerospace installations Description Circular Chart DR 4500 TRULINE The only circular chart recorder that prints its own chart. The DR 4500 Truline Circular Chart Recorder is a one to four-channel, microprocessor-based, 12-inch circular chart recorder. Its one-pen stylus printhead produces up to four analog traces and prints alphanumeric chart data on a blank heat-sensitive chart. All four traces share the same time line reference which the Truline prints. This eliminates the error caused by pen alignment offsets in conventional multiple pen designs. Since the Truline prints the chart and generates the analog traces at the same time, there is no error due to variations in chart size caused by changes in temperature and humidity. The Truline recorder is easily configured to meet a variety of application requirements from metals to food processing. The Truline recorder also alternately displays process variable values for all channels in the selected engineering units. Models with up to four input channels accept inputs from any one of a variety of sensors or transmitters within the configurable range limits. Also, models are available with one or two independent digital controllers to generate controlled output signals to operate valves, dampers, heating elements, etc. for process control. Available with both FM and UL Approvals. Special versions offered are the R Model which adds Fo calculation capabilities, the W version which adds flow calculation capabilities the HTST (High Temperature Short Time) for dairy applications and the AP Pasteurization flow model. DR 4500 CLASSIC The DR 4500 Classic Series Circular Chart Recorder is available as a one or two-pen recorder only model, or a model with one digital controller. All models are designed for use in industrial application and they are user configurable, since microprocessor control replaces conventional electromechanical recording techniques in the DR 4500 recorder. Inputs from any one of a variety of sensors or transmitters within the configurable limits can be accepted. Besides recording analog traces, the DR 4500 includes clear bright alphanumeric displays, indicators, deviation bargraphs, and keypad for visual and tactile interaction. The case is designed for flush or surface mounting.

DR 4300 The DR 4300 General Purpose 10 Circular Chart Recorder uses a microprocessor to generate pen drawn analog traces on pre-printed charts. It is user configurable, which allows it to be adapted to a wide range of applications, such as environmental chambers, food processing equipment, machines, furnaces, ovens, packaging equipment, plus types of machines. The DR 4300 can be purchased with optional display, control capability, communications, and totalization capability. Both one and two pen models accept inputs from any one of a variety of sensors and transmitters within the configurable range limits. One or two integral digital controllers allow the recorder/ controller to operate valves, dampers, heating elements, etc., for process control. The DR 4300 is the replacement for the DR 4200 GP/EV Recorder. MODEL 61 The Model 61 two-pen recorder monitors and records relative humidity and temperature directly using internal sensors. The one-pen version only measures and records relative humidity. The case has a carrying handle and rubber feet, and can be wall or duct mounted. Strip Charts DPR 3000 The DPR 3000 Digital Process Reporter is a multichannel, microprocessor-based, strip chart recorder. It records up to 32 analog inputs on a 250mm (10-inch) wide chart. Three data-presentation formats combine with six-color printing to product clear and concise chart records tailored to your process recording needs. In addition, digital displays provide easy-to-read selected channel and alarm data at a glance. Digital inputs and internal relays are available for expanded data gathering and alarm interface capabilities. The DPR 3000 recorder accepts a variety of voltage, current and resistance type signals as analog inputs to measure process variables that are convertible to an electrical signal. DPR 180 The DPR 180 is a multichannel microprocessor-based strip chart recorder which can record up to 24 analog and up to 20 digital traces on a 180mm chart. With six color printing the recorder can produce clear, concise chart records tailored to your process recording needs. The DPR 180 recorder has the capability to meet the current needs of process recording with advanced features, such as universal communications PCMCIA data storage, digital I/O, PC configuration, and archiving software package as well as a full function math package. DPR 250 The DPR 250 Digital Process Recorder is a multichannel, microprocessor-based strip chart recorder. It records up to 32 analog inputs, math results, or communications inputs on a 250mm (10-inch) wide chart. It uses six color printing to produce clear, concise chart records that can be tailored to your particular process recording needs. A VFD display provides an easy to read display that can show up to four Process Variables at once. The DPR 250 is capable of accepting up to 64 analog inputs of voltage, current, or resistance type signals. Along with the input capability, the DPR 250 recorder has such advance features as universal communications, digital I/O, PC configuration, archiving software package, and advance math functions that support such calculations as energy consumption, totalization, Fo sterilization, averages, plus many more. DPR 100A/B/C/D/G/H The DPR 100 is a microprocessorbased 100mm (4-inch) strip chart recorder with high functionality and low price for general purpose applications. This recorder has been designed to satisfy our customers worldwide with quality, ruggedness, flexibility, ease of use and an outstanding price/performance ratio as the major requirements which guided its design. The DPR 100 is available as a 1 to 3 pen continuous recorder or a 1 to 6 channel digital pen multipoint recorder. With a large view roll or fan-fold chart, the recorder documents date, time, range, engineering units, chart speed, a two digit identification number, alarm set points and events. The DPR 100C/D Recorder utilizes a large 12 digit display and full configurability through the front key panel. Advanced Math Functions, Communications, Alarms and Digital Inputs make this a high functionality recorder that meets the needs for general purpose applications. The DPR 100A/B Recorder is a lower cost alternative to the DPR 100C/D. The product configuration, stored in nonvolatile memory, is printed on the chart and configured by means of printed prompting or by a Honeywell PC interface. The DPR 100 has been designed for applications in the metal, glass, ceramics and utilities, as well as the fast growing environmental, health and sanitation, and food processing markets. DPR 100G/H The DPR 100G/H is the right choice when low cost, high reliability and excellent environmental ruggedness is the requirement. This 100mm (4-inch) analog strip chart recorder is available with one to three pens or 6 input multipoint. Preprinted charts are available in either fan-fold or roll type. These recorders are designed for those applications requiring limited chart documentation. VRX 100/150 VIDEO RECORDERS The VRX 100/150 provides the best choice for video recording and is designed to satisfy a wide range of recording as well as control applications. Two models are available: The VRX 100 is designed for applications which require full DIN compliance for mounting and installation. The VRX 150 provides all the functions of the VRX 100 but uses a larger 10.4-inch diagonal, full-color, active matrix display. Both instruments have the capability of up to 12 Analog Inputs, Alarms, Control, Advance Math along with flexible data storage capability. RS485 communications capability provides the means of networking the recorders for real-time data acquisition. Even in the toughest applications or environments, you ll find that Honeywell recorders work!

Decision Tree Decide on combination of functions and types. Dots mark availability column. Follow availability column to model and specifications. Function Type Availability Measuring Techniques Electronic Direct Sensor Actuated Temperature Humidity Measured Variable Liquid Level, Pressure Voltage Resistance Current Circular Chart Display Presentation Pen Strip Chart Multipoint Digital Controller Set Point Programmer Electric Digital Video Graphic Specification Model 44-01-03-04 DR 4300* 44-45-03-14, 44-45-03-15 DR 4500* 43-DR-03-05 DPR 3000* 46-61-58-01 61 0I-6030 DPR100A/B 0I-6021 DPR100C/D* EN0i-7449 DPR100G/H 43-DR-03-11 DPR 180* 43-DR-03-09 DPR 250* 43-DR-03-10, 43-DR-03-13 VRX 100/150 *Include digital displays

Summary Specification (See Figure 1) Model Numbers Type Calibration Accuracy % Span Span Step Response Time Seconds Min/Max Operating Power Ambient Temperature Limits F/ C Approximate Weight Min/Max Volts Hertz Min. Max. lb kg DR 4300 Circ. Chart Typ. 0.35 7.0 100-230 50/60 32/0 131/55 12 5 DR 4500 Circ. Chart 0.1 6.0 120/240 50/60 32/0 131/55 13 6 DPR100G/H Strip Chart 0.50 120/220/240 50/60 32/0 122/50 13 6 DPR100A/B Strip Chart 0.25 DPR100C/D Strip Chart 0.1 120/220/240/ 24/48V 50/60 32/0 122/50 13 6 DPR 180 Strip Chart 0.05 1.4 100-230 Vac 50/60 32/0 122/50 38 18 DPR 250 Strip Chart 0.05 2.0 100-230 Vac 50/60 32/0 122/50 48 22 DPR 3000 Strip Chart 0.05 120/220/240 50/60 32/0 122/50 62 28 3.0 RH 61 Cir. Chart 2.0 Temp 1.5 Vdc Battery 20/ 29 150/66 7 3.2 VRX 100 Video Typ. 0.1% 90-250 Vac 50/60 32/0 122/50 8.0 3.6 VRX 150 Video Typ. 0.1% 90-250 Vac 50/60 32/0 122/50 12.0 5.4 (DPR 100) (VRX 100) (DPR 180) (VRX 150) (DPR 250) (DPR 3000) (DR 4300) (DR 4500) 16.5 14 12.2 11.0 419 356 309 279 5.7 144 in mm Figure 1 Relative bezel size of model number listed in Summary Specification