EasyReader Model ER2C

Similar documents
EasyReader Model ER4C

EasyReader Model ER2S

INT-C and INT-F. London Electronics Limited. Panel mounting counter / ratemeter. Connection details, scaling and general information

INT-X-P and INT-X-L Programming instructions

Operating instructions Electronic preset counter Type series 717

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

SCALE & WEIGHT DISPLAYS

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Operating Instructions

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Preset counters, electronic

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Single Axis Position Controller

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

multi-function meters

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Multifunction devices

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

LAUREL ELECTRONICS, INC.

London Electronics Limited. R175X Series of Large Displays. Scaleable Ratemeters

STD-525T PRECISION TIMER

Flexible Counter Series in DIN size 24 x 48 mm

Eaton Durant. Counters, process instruments and hour meters.

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Gamma instabus. Technical product information

Time meter electronic

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Recording to Tape (Analogue or Digital)...10

16-BIT LOAD CELL/DUAL STATUS INPUT

Hour Meters / Timers, electronic

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

Set Point Controller OC557. Operator s Manual

Multifunction Digital Timer

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

Process Transmitter RMA 422

GRT SERIES INSTALLATION & OPERATING INSTRUCTIONS

MT03A Electronic converter for flow rate transmitters

London Electronics Limited. T175X Series of Large Displays. Scaleable Totalisers

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Flexible Counter Series in DIN size 24 x 48 mm

Instruction Manual Model BlockUpconverter

Solid-State Digital Timer

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Panel-mounting thermostats, type series EM

Instruction Manual Model # Block Upconverter

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Telemetry Receiver Installation Guide

Tube Rotator. User Guide. Version 1.2

EA350. Generator Automatic Voltage Regulator Operation Manual

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Process transmitter RMA422

02/11/2015

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

SU17 Series Fiber Optic Sensors

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

C-net WIND. User s Guide

FIELD MOUNTED RATE TOTALISER MODEL 202D

SIGNET 5500 Flow Monitor ENGLISH

By CHANNEL VISION. Flush Mount Amplifier A0350

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

Series CT7N Bimetallic Overload Relays

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Noise Detector ND-1 Operating Manual

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Operating instructions

.Power Distribution Center. PD-1. Instruction Manual

Figure 1: Device components

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

DTV742 Installation Quick Start Guide

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Electronic converter for level transmitters MT03L Instructions manual

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

02/11/2015

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

CONVI104 SWITCHER & ANALOG TO SDI CONVERTER CONVI 104-M 15/03/2006

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

Aspect 2 Circuit Digital Scene Control

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

VK-P10SE WARRANTY REGISTRATION FORM

Electrical connection

Transcription:

London Electronics Limited Thorncote Road, Near Sandy, Bedfordshire SG19 1PU Tel +44(0)1767 626444 Fax +44(0)1767 626446 www.london-electronics.com help@london-electronics.com Large display pulse input counter & frequency meter EasyReader Model ER2C Connection details, scaling and general information Rear case screws - please note The rear panel is held in place with finger-screws, which only need to be gently tightened. Do not use tools to tighten or loosen the screws, as this could cause damage to the internal threads. Document Ref: manuals\english\easyreader\easyreader_2c.p65 Dated: 30 June 2009 Rev. 4

Alphabetic Index Warnings - Read First! 2 Connections 5 Wiring and jumper record sheet 16 Declaration of Conformity 17 Front Panel controls 10 General Description 3 Getting Started 4 Input stage circuit 13 Introduction 1 Input connection examples 5 Lockout connection 5,7, 8 MIN/MAX button 9, 10, Mounting methods 13, 14 Peak reading memory 9, 10 RESET button 9, 10 Revision record 15 Specifications 11 Suspension mounting 14 TARE control 9, 10 Valley reading memory 9, 10 Wall Mounting 13 Warnings 2 index

Introduction Please contact us if you need help, if you have a complaint, or if you have suggestions to help us improve our products or services for you. If you contact us about a product you already have, please tell us the full model number and serial number, so that we can give you accurate and fast help. This product has a 2 year warranty. We will put right or replace any meter which is faulty because of bad workmanship or materials. This warranty does not cover damage caused by misuse or accident. IMPORTANT If this equipment is important to your process, you may want to buy a spare to cover possible failure or accidental damage in the future. This is because at some times, for example during our factory shutdown periods, you may have to to wait several weeks for an equivalent replacement. Or, we may have no stock at the time you urgently need it. You may also need to pay extra carriage charges if you want a fast, guaranteed courier service. Warranty repairs or replacements are normally returned with a standard courier service. We do not offer any compensation for losses caused by failure of this instrument. If you do not agree with these conditions, please return this item now, in unused, clean condition, in its original packaging and we will refund the purchase price, excluding any carriage paid. We thought you d prefer to know about possible delays and extra charges now, rather than during a panic. We always try to improve our products and services, so these may change over time. You should keep this manual safely, because future manuals, for new designs, may not describe this product accurately. We believe these instructions are accurate, and that we have competently designed and manufactured the product, but please let us know if you find any errors. 1

Warnings! Please carefully read all warnings and ONLY install the meter when you are sure that you ve covered all aspects. * Connect the meter according to current IEE regulations and separate all wiring according to IEC1010. * Power supplies to this equipment must have anti-surge (T) fuses at 125mA for 230V supply, 250mA for 110V supply or 1A for DC supplies in the range 11-30VDC. * Check that the model number and supply voltage suit your application before you install the meter. * Don t touch any circuitry after you have connected the meter, because there may be lethal voltages on the circuit board. * We designed this meter for Pollution-Degree 2 environments only. This means you must install it in a clean, dry environment. * Only adjust on-board switches or connections with the power turned off. * Make sure all screw terminals are tight before you switch the meter on. * Only clean the meter with a soft damp cloth. Only lightly dampen with water. Do not use any other solvents. Safety First...Don't assume anything... Always double check. If in doubt, ask someone who is QUALIFIED to assist you in the subject. 2

General Description The EasyReader C displays are large versions of the popular Intuitive counter and ratemeter family. They accept pulse inputs from digital sensors such as NPN, PNP or contact closure proximity detectors. Their main function is to monitor production lines, counting items and monitoring rate of production, but they can also be used for accurate measurement of frequency and speed. They also accept quadrature input signals, so are ideal for bidirectional position monitoring too. Their unique INTUITIVE programming system gives the simplest possible setup procedure. You can scale the counter and ratemeter so that a given number of pulses gives a certain display value. The scaling is digital and highly stable, thanks to a trimmed quartz-crystal timing oscillator. Scale factors from 0.001 to 9999 give wide calibration possibilities. An excitation supply gives you 24V DC at up to 100mA, useful if you want to power an optical sensor, proximity switch etc. 3

Getting Started First, check that the display will suit your application and the available power source (either 95-265 VAC or 11-30 VDC). If you asked us to configure the display for you, please check that the scaling and settings agree with your requirements. We fully tested and calibrated your display for you, but a pre-installation test may be useful to check that everything works as needed. Remove the screws which hold the rear panel in place. Feed the signal and power cables through the cable glands. Connect the signal and power cables to the appropriate screw terminal connectors. See our connection drawing to check that you are using the correct terminals. Check, before switching on, that the power is suitable for the unit. Switch on, and the display should show Ec.X.X for a second or two. (where Ec.X.X is the software version). Units with custom software will have a different prompt. 4

Connections We supply detachable screw terminal connectors to make installation as easy as possible for you. You should use multistrand insulated wire with ferrules to DIN46228/1. You can use stripped wire with cross sectional area from 0.5 to 2.5mm 2. Strip back insulation 7mm. Pull-Up Pull-Down Pullup/down Debounce I/P2 Debounce I/P1 Signal I/P Excitation + Input 2 Input 1 Common Lockout Off On (for contact closure inputs) Sensitivity 2.5V & 3.5V thresholds 0 and 1V thresholds 0 and 20mV thresholds Screen termination point You may want to see the input stage circuit diagram. It is on page 12. You can also fill in a wiring record sheet on page 16 for future reference Logic I/Ps Common not used not used Peak/Valley Reset You can operate the Tare, Peak/Valley and Reset functions remotely with contact closures, or with the front panel buttons. To activate the front panel buttons, you must make permanent connections between the desired function connector and Common Power Earth Neutral Line Rear-case Finger-Screws - please read carefully Only gently tighten these screws. There is no need to fit them so tight that your fingers hurt. We use this type of screw to prevent damage from being caused to the threads. Do not use hand or power tools to tighten these screws. Use screened cable for the input signal and connect the screen to power earth at the meter end of the cable only. For best performance, keep the signal cable well away from the power cables, which could carry electrical noise likely to interfere with your measurement. Some Input Connection and jumper positioning examples: Excitation + Input 2 Input 1 Common Lockout Excitation + Input 2 Input 1 Common Lockout Excitation + Input 2 Input 1 Common Lockout NPN Sensor PNP Sensor Contact Closure (Default) Locked Unlocked Locked Unlocked Locked Unlocked 5

Modes The EasyReader-C has 7 display modes to suit various counting and rate measurement functions. Here is how to select one of these modes:- 1. Connect the Lockout terminal to the Common terminal, then apply power to the display 2. Press the Mode button for 3 seconds, then release. 3. Use the UP arrow or Down arrow button to select from this list : 1. Basic Totaliser 1 pulse input Can be scaled with positive (count up) or negative (count down) scale factor. 2. Gated totaliser 1 pulse input and 1 gate input. Can be scaled with positive (count up) or negative (count down) scale factor. The gate is on INPUT2. Gate open = HI Gate closed = LOW 3. Totaliser 1 pulse input and 1 direction input If you use a positive scale factor, the counter will increase for pulses on INPUT1 if INPUT2 is high, decrease if INPUT2 is LOW. 4. Totaliser 1 input UP count, 1 input DOWN count. Pulses on INPUT1 count down Pulses on INPUT 2 count up 5. Totaliser with 2 pulse inputs for UP counting Pulses on both INPUT1 and INPUT2 count up 6. Quadrature counter with 2 phased inputs Phased pulses on INPUT1 and INPUT2 count up or down depending on phase. 7. Rate meter - Single input Displays the frequency or scaled rate of pulses on INPUT1 4. Press OK when you have made your choice. Now you need to scale your display... 6

Scaling for the 6 Counter modes... On the previous page, you saw how to select from one of 7 different modes. The first 6 modes are all counter functions, which all have the same method of scaling. To select a mode, you pressed OK. If you selected one of the first 6 counter modes, your display should now show:- Pulses In Display The value you can set for each of these 3 variables Preset (pre-load) P.Set lets you start the counter from some value other than 0. For example if you wanted to fit a new counter into a system which has already passed 1367 litres, you would set P.Set to 1367 and the counter would start counting from this value. You ll see one digit brighter than the others - this means you can change its value with the UP or DOWN button. Use DIGIT button to select other digits. Select decimal-point with the DIGIT button if you want to change the decimal-point position. Move the decimal-point with UP/DOWN buttons. Press OK when you have set the whole number, to move on to the next variable Typical examples: On a production line you get 1 pulse for every item. You want to count number of items. P.in = 1 disp = 1 P.Set = 0 In a paper mill, you want to measure length. You have a wheel sensor which gives 433 pulses per metre of material. You want to count metres to 1 decimal place (tenths of a metre) P.in = 433 disp = 1.0 P.Set = 0.0 You have a rotary encoder which gives 5000 pulses per rotation (360 degrees). You want to display degrees rotation P.in = 5000 disp = 360 P.Set = 0 A flow sensor gives 2345 pulses per litre You want to count milli-litres (cc). You want the display to start from 450 ml P.in = 2345 disp = 1000 P.Set = 450 IMPORTANT To protect your settings, disconnect the LOCKOUT link on the input connector. 7

Scaling for the Ratemeter Mode The Ratemeter mode is ideal if you want to measure Frequency, Speed, Rate of production etc. Frequency In (Hz.) The value you can set for each of these 3 variables Display The scaling method is simple. Specify a Frequency in Hz and a reading the display should show for that Frequency. For example, if you have a sensor which gives 200Hz at 5 litres per minute and you want to measure flowrate in litres/minute... F.in = 200 disp = 5 or 5.0 or 5.00 depending on the resolution you want. Averaging You ll see one digit brighter than the others - this means you can change its value with the UP or DOWN button. Use DIGIT button to select other digits. Select decimal-point with the DIGIT button if you want to change the decimal-point position. Move the decimal-point with UP/DOWN buttons. Press OK when you have set the whole number, to move on to the next variable Possible values = 0,2,4,8,16,32 and 64 Averaging is useful if the input frequency is not stable. The bigger the averaging number, the more stable will be the display. Big averaging numbers also make the display respond less quickly to sudden changes in input frequency. The largest averaging number is 64, which means that 64 readings will be averaged. Time-Out (seconds) Possible values = 3,10,30 and 60 The time-out function is normally set to 3 seconds. This means that if the input pulses stop for any reason, the display will hold the last reading for 3 seconds, after which it will go to 0. You can increase this delay up to 60 seconds. IMPORTANT To protect your settings, disconnect the LOCKOUT link on the input connector. 8

Contact closure inputs The contact closure inputs allow you to operate the Max/Min and reset functions remotely, but only when the meter is locked. The switched signal is 5V DC at a current of 1.5mA Remote contact-closure inputs Min/Max Reset Common not used not used Peak/Valley Reset Min/Max In Rate mode only, Contact closure sequentially displays the Maximum and Minimum scaled Rate or Frequency values, since the display was last reset. The display will time out and return to showing the actual input after 3 seconds. ** If you make a permanent connection between Common and Min/Max, you can access this function with the button labelled Max/Min on the display s front panel RESET In any one of the 6 Totalsing modes, contact closure will reset the accumulated total. In Rate mode, Contact closure will reset the stored Max and Min and averaging history values. ** If you make a permanent connection between Common and Reset, you can access this function with the button labelled Reset on the display s front panel 9

Front panel controls Control Type Function 4 pushbutton switches located behind a flexible overlay. Depends on whether locked or in setup mode. Also depends on remote input contact status - see below.. Mode Digit Max/Min Reset OK Contact-closure inputs are used to activate front-panel buttons Link to activate Max/Min button Link to activate Reset button Common not used not used Max/Min Reset Normal running mode (Locked) MAX / MIN RESET Selects max/min/current rate or frequency readings (When in Rate mode), in turn if the remote MIN/MAX terminal is connected to Common. Press to reset any, max., min. and filter history if the remote Reset terminal is connected to Common. Setting mode (unlocked) Mode DIGIT UP arrow DOWN arrow OK Press for more than 3 seconds. Lets you adjust the functional mode of the display if the display is unlocked. Chooses a digit to be changed on the display, while adjusting a variable when the display is unlocked Each press increases a chosen digit value, while adjusting a variable when the display is unlocked Each press decreases a chosen digit value, while adjusting a variable when the display is unlocked Confirms any changes made or skips to next step. 10

Specifications Bezel size Case Depth Weight Case Material Connectors Operating Temp. Storage Temp. Power supply Power consumption Input Signals Pull up/down resistor Input Frequencies Operating Overload Display type Digit height Viewing distance Accuracy Scaling tempco Excitation voltage Filtering Display update rate Memory 260mm wide x 140mm high 75mm 600 grammes Black upvc with Acrylic lens Internal Detachable Screw Terminal connectors 0 to 50 degrees C, non condensing humidity -20 to 70 degrees C 95-265 VAC or 11-30 VDC optional 8 watts maximum 3 Jumper selectable thresholds with hysteresis:- 1. 2.5 to 3.5V (default) for signals 0-5V to 0-30V 2. 1V AC or more 3. 0-20mV RMS or more Accepts any of these sensor types:- NPN proximity or opto PNP proximity or opto Contact closure CMOS 5V to 18V PLC 5V, 12V 24V or 48V Logic Passive inductance pickup, signal more than 40mV p-p 22 Kilohms to Excitation + or 0V respectively With debounce jumpers 0 to 30 Hz. scalable Without debounce jumpers 0 to 50 KHz. scalable Can accept up to 60V without damage High efficiency LED, red or green 57mm (A 102mm high model is also available) 25 metres (50 metres with 102mm digit model) +/-0.05% of range +/-2 counts in Frequency mode 20ppm/Degree Celsius max. for Rate/Frequency 24VDC +/- 20% rated at 100mA. Noise 200mV max (50Hz-100KHz) Selectable time constants up to 5 secs in 0.5sec increments In any of the 6 Counting modes: The display will update with each incoming pulse up to 10 updates per second for frequencies above 10 Hz. In rate mode: For frequencies above 3Hz., display will update 3 times per second. For frequencies below 3 Hz. the display will update on each input pulse, provided the interval between pulses is less than the chosen timeout period of 3, 10, 30 or 60 seconds. Programme settings and accumulated total have 10 year data retention in solid-state memory which does not need batteries to operate. 11

Notes Circuit diagram showing one of the two input stages. This shows the pullup, debounce and sensitivity setting methods. Excitation + Input + 47K + Input comparator - 18K Pull Up Pull Down 0.1uF Debounce Threshold 3V 1V 20mV Common 12

How to Mount your display 1. Wall Mounting Wall mount your EasyReader display in a clean, dry environment. Drill 4 holes in your wall, spaced as you see in this diagram... The mounting screws you use should have a diameter between 3.4 and 4.6 mm and should be suitable for the material of the wall. You may need to use wall plugs or other screw accessories, if the wall material is not suitable to take screws directly. 253 mm 211 mm The 4 bracket holes are all 5mm diameter Fit the brackets to the wall. Then, fit the display between the brackets. Place the brackets as shown, so that the display covers the 4 mounting screws Side View Wall bracket Wall M8 Pan Screw M8 Spring Washer M8 Plain Washer 25mm rubber washer 2.5mm 25.0 mm 47.5 mm Route cables neatly away from the display. If the cables may become damaged in the environment, protect them with suitable conduit or trunking. 13

How to Mount your display... continued 1. Suspension Mounting Suspension mount your EasyReader display in a clean, dry environment. The mounting screws you use should have a diameter between 3.2 and 3.8 mm and should be suitable for the supporting material. You may need to use screw plugs or other screw accessories, if the material is not suitable to take screws directly. Mount the brackets first, then fit the display to the brackets. 25.0 mm View down onto top of bracket 3 holes 4.5mm diameter 85.0 mm 85.0 mm M8 Pan Screw M8 Spring Washer M8 Plain Washer 25mm rubber washer Route cables neatly away from the display. If the cables may become damaged in the environment, protect them with suitable conduit or trunking. 14

Record of Revisions 30 January 2004 Product released 16 February 2004 Added input stage diagram to page 12 25 March 2004 Added wiring and jumper record sheet on page 16 30 June 2009 Address updated 15

Wiring and jumper record For future reference, record all the jumper positions and wiring colours you used in your installation. 16

Declaration of Conformity Declaration Reference : EasyReader Issue Date : 16 December 2003 Products Covered : EasyReader series Title : DOC-EasyReader This is to confirm that the Product covered by this declaration has been designed and manufactured to meet the limits of the following EMC Standard : EN61326-1:1997 and has been designed to meet the applicable sections of the following safety standards EN61010-1:2001 Conditions The meters covered by this certificate must be installed in adherence to the following conditions :- Signal cabling shall be routed separately to power carrying cabling (includes relay output wiring) All signal cabling shall be screened. The screen shall only be terminated to the power earth terminal Declared as true and correct, for and on behalf of London Electronics Ltd. J.R.Lees Director 17