Technical Instructions

Similar documents
Premium Class Launch Amplifier 13 in 8

w w w.w h y t e t e c h n o l o g i e s.c o m.

User Guide. TMDS 5x C Digital SCR Multiswitch for SkyQ. Version B Date 02/2016 EN TMDS 54 C TMDS 58 C

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

a Quick Guide Triax Multi Switches

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

SPAUN SOTx NF & SORx NF

SAT IF distribution technologies. Multiswitches and single cable multiswitches for 1, 2, 3 or 4 SAT positions

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

SAT IF distribution system

TXSYSTEMS. Circuit of a TCG15 AD. Dish Specification 60CM

Installation location

Compact Power for Every Distribution Network

TV Radio Multimedia MHz amplifiers, distribution and connection technology. 99High output levels 99High reliability 99Maximum durability

Single cable multiswich programmer PC102W

Satellite B or D. Satellite Inputs (LNB Trunk)

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

SAT IF-IF conversion system 9 cable system 5 cable dscr system 17 cable system System accessories 5 cable system

Devices. Signal reception socket outlets - TECHNICAL CHARACTERISTICS C - Pouyet C - IBM, Reichle & De Massari

Unicable II Programmable/cascadable multiswitch with 32 User Bands, 4 Universal/Wideband Satellite inputs & 1 Terrestrial input

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

TV Radio Multimedia. Optical Nodes, 1218 MHz and 1006 MHz amplifiers, distribution and connection technology

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

SEM 9X USER S MANUAL

FRACARRO SWITCHLINE GET SMART WITH THE NEW FRACARRO SWITCH RANGE

TSM 1000 HD-C TSM 1000 HD-CF

V TV / SATELLITE DC Power Tester

SEM 5X USER S MANUAL

HDO701 FIBRE OPTIC TRANSMITTER

Compact EGC Fiber Deep Nodes A90100 and A90300

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

Switching and installation examples

2015 OPTICAL TRANSMITTERS

Assembly. Front view. LEDs. Parametrization interface. Power Bus

It receives contents from 4 DVB-T/T2, DVB-S/S2 or DVB-C transponders/muxes and broadcasts them in 4 DVB-T, DVB-C or IP output channels.

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

DVO700 P FIBRE OPTIC TRANSMITTER

PR FESSIONAL PROFESSIONAL HEADEND DIGITAL MODULATOR PSDF Grundig SAT Systems

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

User Manual. dcss/dscr Multiswitch 9733PL 9734PL

ATS50SAW Programmable Selective Amplifier

384A Adapter Installation Instructions

beyond your expectations

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

INSTALLATION MANUAL. CTMS-516RKPS Rack Mount Satellite Multiswitch

Kathrein is a leading international specialist for reliable, high-quality communication technologies.

SAT 75 SAT Reflector-Ø 0,75 0,85. 41, ,5 Half-value aperture 38,3 2,4 2,1. 1,37 Mount for mast Ø

Model GS Port Node 1 GHz with 65/86 MHz split

(CTOPT-TXDT) FRACARRO 1310 OPTICAL TRANSMITTER INDOOR (CTOPTRX) FRACARRO QUAD MINI FIBRE RECEIVER (CTOPTRX4) FRACARRO QUATRO MINI FIBRE RECEIVER

PHASE HL SEL 1 HL SEL 2 EXT MONITOR ELAN ELAN ELAN ELAN MLM-201 HLM-201 HLM-201 TBM-201 MLM-201 GAIN GAIN GAIN LEFT GAIN RIGHT SELECT SELECT SELECT

AS/NZS 1367:2016. Australian/New Zealand Standard

AMU2-2MHD+ Audio monitoring Unit

Grundig SAT Systems SATELLITE TV CONVERTER STC 1200 ENGLISH

OLS 5X USER S MANUAL

Model FS-4608R. Features. Overview

Multi Room Audio Matrix Switcher

CSE 2800 digital main unit

Filters for Power Lines (Low Leakage Current)

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

coaxial passives & accesories

MAW-201 (3031) MULTISTANDARD VHF/UHF TV MODULATOR

Figure 1: V 713 CI plug-in card

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Figure 1: V 613 CI plug-in card

DVX. Digital Versatile Headend

ACTIVE IF SPLITTER/COMBINER UHP-IFS

R&S ZN-Z85 Switch Matrix Specifications

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Johansson Catalogue EDITION 2013

A MULTISWITCH HAS NEVER BEEN SO CLEVER

Unicable II Cascadable switch with Terrestrial input and 4x Sky dscr/satcr/legacy+terrestrial outputs

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Vision EV5-D2, EV5-D4 multi-switch installation

Recording to Tape (Analogue or Digital)...10

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

TAMP6R03 (6)TRUNK AMPLIFIER

DISTRIBUTION AMPLIFIER

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Compact EGC Amplifier Model 93250

presents : Single Transmod Ref. 8600

Model /29S RF Splitter

Multi channel programmable Filter-Amplifier

Convincing technology - faster mounting

Model FS-4608SR. Features. Overview

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

LED control gear Compact fixed output

E3/DS3 Fibre Extender

AMU1-BHD+ Audio monitoring Unit

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

XCOM1002JE (8602JE) Optical Receiver Manual

distribution passives basic series

DIGITAL MODULATOR SINGLE DVB-T ENCODER/MODULATOR USER MANUAL

MKH 8060 Directional studio microphone

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

MODEL UDU-205 UDU-307 UDU-408 UDU-612 UDU-813 REF MHz 4,8 9,7 10,4 15, MHz

DA-12R. User Manual. 1 to 2 RGBHV Distribution Amplifier. rev (English) COMM-TEC GmbH Siemensstr. 14 D Uhingen

Transcription:

Byk-Gulden-Str. 22 D-78224 Singen Telephone: +49 (0) 7731-86730 Fax: +49 (0) 7731-64202 e-mail: info@spaun.de www.spaun.de Technical Instructions for the launch amplifiers SBK 3301 NF, SBK 3302 NF and SBK 3305 NF the cascadable multiswitches SMK 3342 F, SMK 3362 F, SMK 3382 F and the repeater amplifiers NVF 3322 SR and NVF 3323 SR Important: Please observe the following instructions! Installation is only permitted in dry rooms and upon a non-combustible surface. Ensure that there is adequate air circulation. The permissible ambient temperature range is: -20 C to +50 C (253 K to 323 K). Wall mounting only with power supply housing on the left or an the right side (horizontal mounting). The components meet the more stringent screening requirements according to amendment 1 of EN 50083-2, quality grade A. All Components are equipped with an earthing terminal for connecting to the main potential equalization. SPAUN electronic confirms the keeping of the EMC requirements in accordance to the CENELEC standard EN 50083-2 and the keeping of the safety requirements in accordance to the CENELEC standard EN 50083-1 by the CE sign. The C-Tick mark shows the conformity of the device with the EMC regulations of the ACA. (ACA requirements bases on CISPR, CENELEC and IEC standards). Specifications and design are subject to change due to our policity of continual technical improvement. 104330/08.04

Setting instructions: Power Supply to LNB: LNB Factory settings: 12 V 12/18V + 22 khz Factory settings: 12 V / 12 V SBK 3301 NF and SBK 3302 NF Supply modes: SBK 3305 NF Supply modes: V Input to LNB V Input to LNB H Input to LNB 12 V 12 V 12 V 18 V 12 V 18 V 22 khz 12 V + 22 khz 18 V + 22 khz H Input to LNB 12 V / 12 V 12 V 12 V 12 V / 18 V 12 V 18 V 18 V / 18 V 18 V 18 V 12 V / 12 V + 22 khz 12 V + 22 khz 12 V + 22 khz 12 V / 18 V + 22 khz 12 V + 22 khz 18 V + 22 khz 18 V / 18 V + 22 khz 18 V + 22 khz 18 V + 22 khz The LNB remote current must not exceed a total of 0,4 A. Level Adjusters: SAT: The launch amplifiers (SBK...) have separate level adjusters for each SAT IF Input. The remote powered repeater amplifiers (NVF...) work with a single synchronous level adjuster for all SAT IF Inputs. The input levels of the SBK 3301 NF, SBK 3302 NF and NVF 3322 SR can be reduced by 0... 8 db. The input level of the SBK 3305 NF can be reduced by 0... 10 db and the NVF 3323 SR can be adjusted by 0... 7 db; Factory settings: 0 db. Terrestrial: The launch amplifier SBK 3302 NF is equipped with an adjustable attenuator in order to adjust the level of the terrestrial or CATV signals. The input levels can be reduced in active mode by 0... 10 db. The signal is not amplified in the passive setting. The launch amplifier SBK 3305 NF is equipped with an adjustable attenuator in order to adjust the level of the terrestrial or CATV signals. The input levels can be reduced by 0... 12 db. No passive setting for the terrestrial amplifier. Factory settings: 0 db.

Power Supply: The launch amplifiers have internal, energy-saving, switched mode power supplies. U~: 100-240 V 10 % / 50-60 Hz. Power consumption (with max. remote current): SBK 3301 NF SBK 3302 NF SBK 3305 NF SAT active Terr. passive 14,5 W 28,5 W - SAT active Terr. active - 32 W 43 W Repeater amplifier supply: The SBK 3301 NF is not designed to supply a remote powered network repeater amplifier. The launch amplifiers SBK 3302 NF and SBK 3305 NF provides a continuous remote voltage at the output trunklines to supply a network repeater amplifier. Attention! Use the three DC-blockers attached to the launch amplifiers, in case of connecting equipment that may cause a DC shortcut at the trunkline outputs. For the SBK 3302 NF the maximum permissible total current delivery is 650 ma at 18 V. The current must not exceed 500 ma per socket. The SBK 3305 NF delivers a maximum permissible total current of 1000 ma at 18 V. The current must not exceed 500 ma per socket. The SBK 3302 NF or the SBK 3305 NF can feed only one remote powered repeater amplifier of the types NVF 3322 SR or NVF 3323 SR. Repeater amplifier consumption: The repeater amplifier NVF 3322 SR and the NVF 3323 SR can be remote powered from each trunkline. Remote power voltage range: 12 V to 20 V. Remote power current consumption: NVF 3322 SR: 515 ma @ 15... 20 V. NVF 3323 SR: 510 ma @ 15 V 420 ma @ 19 V The remote current must not exceed 500 ma per socket.

Terrestrial: The launch amplifier SBK 3301 NF has a passive terrestrial (5... 862 MHz) with a through loss of max. 3,5 db. This means the SBK 3301 NF is return path compatible. The terrestial inputs of the SBK 3302 NF and NVF 3322 SR / NVF 3323 SR have adjustable attenuators. The amplifier unit (47... 862 MHz) is designed CATV compatible, by the use of a push-pull power amplifier. The terrestrial signal can also be passed through passively. To do this, the adjustable attenuator must be turned counter clockwise to the limit. The terrestrial amplifier then will be bypassed, the through loss is max. 4 db. At the same time, the frequency range expands to 5... 862 MHz; this means the devices are return path compatible. The terrestrial input of the SBK 3305 NF has an adjustable attenuator. The amplifier unit (47... 862 MHz) is designed CATV compatible, by the use of a push-pull power amplifier. It is not recommended to connect aerials directly to the terrestrial input. Selective devices should be used to avoid interference, e.g. FMP 30, VFM.. F or MBV.. PF. SAT IF Distribution: The maximum input level is typically 83 dbµv for each launch amplifier, if the adjustable attenuator is turned on lowest attenuation and with full transponder load. The IF signals are to be fed into the launch amplifier and the multiswitches in accordance to the labeling so that the logical assignment of the IF signals matches the switching criteria.

Maximum output levels of the Launch amplifiers: SBK 3301 NF 950... 2200 MHz 110 dbµv @ 35 db IMA 3 / EN 50083-3 950... 2200 MHz 110 dbµv @ 35 db IMA 2 / EN 50083-3 SBK 3302 NF 47... 450 MHz 110 110 108 113 A: 19 Ch 47... 606 MHz 110 110 104 108 C: 29 Ch 47... 862 MHz 109 109 100 110 E: 42 Ch 950... 2200 MHz 110 35 db IMA 3 / EN 50083-3 950... 2200 MHz 110 35 db IMA 2 / EN 50083-3 SBK 3305 NF 40... 450 MHz 117 120 112 122 A: 19 Ch 40... 606 MHz 117 120 110 117 C: 29 Ch 40... 862 MHz 117 120 107 115 E: 42 Ch 950... 2200 MHz 117 35 db IMA 3 / EN 50083-3 950... 2200 MHz 117 35 db IMA 2 / EN 50083-3 Maximum output levels of the remote powered network repeater amplifiers: NVF 3322 SR 47... 450 MHz 109 109 106 111 A: 19 Ch 47... 606 MHz 109 109 102 105 C: 29 Ch 47... 862 MHz 109 109 99 102 E: 42 Ch 950... 2200 MHz 110 35 db IMA 3 / EN 50083-3 950... 2200 MHz 110 35 db IMA 2 / EN 50083-3 NVF 3323 SR 47... 450 MHz 115 115 115 112 A: 19 Ch 47... 606 MHz 115 115 113 110 C: 29 Ch 47... 862 MHz 115 115 109 105 E: 42 Ch 950... 2200 MHz 115 35 db IMA 3 / EN 50083-3 950... 2200 MHz 115 35 db IMA 2 / EN 50083-3

Cascadable multiswitches: SMK 3342 F, SMK 3362 F and SMK 3382 F These modules are the switching components of the cascadable IF distribution system. The have to be placed in the line behind the launch amplifiers. They also support the terrestrial signal distribution and they are return path compatible. In case of a central distribution, the components can be interconnected with ZSV 2 S push-on connectors, or they may also be installed separated from each another as storey distributors. The trunklines of the cascade have to be terminated with DC-insulated resistors (ZFR 75 DC). These DC insulated resistors are supplied with the launch amplifiers. Typically a number 3 or 4 cascadable multiswitches can be installed in a line without using a repeater amplifier. To increase the number of outputs in one cascade line a repeater amp can be used (type NVF 3322 SR or NVF 3323 SR). The current consumption of the cascadable multiswitches for switching is 25 ma at the used output. Technical data: Type designation SMK 3342 F SMK 3362 F SMK 3382 F Order no. 842404 842405 842406 Frequency range 1 x 5... 862 MHz / 2 x 950... 2200 MHz Number of subscribers 4 6 8 Through loss SAT 1... 2 db 3,5... 4,5 db 3,5... 4,5 db Through loss Terr. 4 db 6 db 7 db Tap loss SAT 21... 17 db Tap loss Terr. 20 db Switching Isolation V / H > 26 db Insulation: Trunkline / Trunkline Tap / Tap Current requirement per receiver Dimensions W = 140 mm H = 90 mm D = 38 mm > 40 db > 26 db max. 25 ma W = 140 mm H = 153 mm D = 38 mm Your partner for Australia: 1 A Carnarvon St. PO Box 6147 Silverwater NSW Silverwater NSW 2128 Australia 1811 Australia Phone: +61 2 9648 1132 Fax: +61 2 9648 1135 sales@jonsa.com.au www.jonsa.com.au

Application Diagrams: SMATV networks Star distribution Terrestrial and 2 SAT IF signals 24 Subscribers / Receiver: 48 Subscribers / Receiver: