LED Driver Compact fixed output

Similar documents
LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED control gear Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Emergency lighting units EM powerled

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Emergency lighting units EM powerled

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact dimming

LED Driver Constant voltage

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Compact dimming

LED Driver Compact dimming

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

OT 100/ /700 P5

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

OPTOTRONIC Intelligent

HID control gear Electronic

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

LED MODULES READYLINE DL

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Technical Information

DALI TOUCHPANEL BASIC TW. Operating and control unit

Indoor Linear 80W Driver SI-C215280N2KR

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

Catalogue Ignitors and power switches for HID

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

02/11/2015

Gamma instabus. Technical product information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Figure 1: Device components

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Type: DILM25 10(24V50HZ) Article No.:

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Operating instructions

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Series CT7N Bimetallic Overload Relays

Type: DILM12 10(24VDC) Article No.:

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

AS09..S 3-pole Contactors - Spring Terminals

15 Series - Dimmer

TOSHIBA Industrial Magnetron E3328

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Datasheet - SRB-E-201ST

Process Transmitter RMA 422

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

KRF EMC Filters Installation, Operation and Maintenance Manual

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

ABB i-bus EIB Universal dimmer 6155 EB for Installation

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Process transmitter RMA422

architecture mounting Features Product lighting

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Product Data Sheet 8506 VW-691

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

AF-300 E11 Adjustable Frequency Drive

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Linear flow controls VFC Linear flow controls with actuator IFC

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Linear flow control with actuator IFC

10 SERIES. Light dependent relays A

Magnetic Sensor - Incremental EHP

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

MAP110 AC-DC Series Data Sheet

Absolute Rotary Encoder E6CP

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Electrical Specifications

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Kuhnke Technical Data. Contact Details

Modular pulse operated latching relay 16 A

ODW-621. RS-232 Point-to-point applications

Transcription:

Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000 h For luminaires of protection class I and protection class II Temperature protection as per EN 61347-2-13 C5e 5-year guarantee Properties Casing: polycarbonat, white Type of protection IP20 Functions Overtemperature protection Overload protection Short-circuit protection No-load protection È Standards, page 3 Wiring diagrams and installation examples, page 4 www.tridonic.com 1

Driver LC 45W 1050mA fixc C SNC ESSENCE series Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V Mains frequency 50 / 60 Hz Overvoltage protection 320 V AC, 1 h THD (at 230 V, 50 Hz, full load) < 20 % Output current tolerance 3 ± 7.5 % Typ. current ripple (at 230 V, 50 Hz, full load) ± 30 % Turn on time (at 230 V, 50 Hz, full load) 0.5 s Turn off time (at 230 V, 50 Hz, full load) 0.5 s Hold on time at power failure (output) 0 s Ambient temperature ta -20... +50 C Ambient temperature ta (at life-time 50,000 h) 40 C Storage temperature ts -40... +80 C Dimensions L x W x H 103 x 67 x 29.7 mm 13,2 483 4,5 Ordering data Type 3 93,5 103 5 22,2 5 4,2 Article number 29,7 57,5 67 carton low volume high volume Weight per pc. LC 45W 1050mA fixc C SNC 87500564 15 pc(s). 345 pc(s). 2,760 pc(s). 0.126 kg Specific technical data Type Output Input current current 3 (at 230 V, 50 Hz, full load) input power Typ. power consumption (at 230 V, 50 Hz, full load) Output power range λ at Efficiency λ at Efficiency Min. full load 1 at full min. load 1 at min. forward load 1 load 1 voltage forward voltage output voltage output output casing peak current peak current temperature at full load 2 at min. load 2 LC 45W 1050mA fixc C SNC 1,050 ma 0.225 A 51 W 49.5 W 31.5 45.0 W 0.96 90.5 % 0.94C 89.5 % 30 V 43 V 54 V 1,470 ma 1,680 ma 90 C 1 Test result at 230 V, 50 Hz. 2 The trend between min. and full load is linear. 3 Output current is mean value. www.tridonic.com 2

Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 61547 Overload protection If the output voltage range is exceeded the LED Driver will protect itself and LED may flicker. After elimination of the overload, the nominal operation is restored automatically. Overtemperature protection The LED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded, the output current is reduced to limit at a certain level. The temperature protection is activated typically at 10 C above max. Short-circuit behaviour In case of a short circuit on the secondary side (LED) the LED Driver swihes into hic-cup mode. After elimination of the short-circuit fault the LED Driver will recover automatically. No-load operation The LED Driver works in burst working mode to provide a constant output voltage regulation which allows the application to be able to work safely when LED string opens due to a failure. Glow-wire test according to EN 61347-1 with increased temperature of 850 C passed. Mounting of device torque for fixing: 0.5 Nm/M4 Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Installation instructions The LED module and all contact points within the wiring must be sufficiently insulated against 3 kv surge voltage. Air and creepage distance must be maintained. Replace LED module 1. Mains off 2. Remove LED module 3. Wait for 10 seconds 4. Connect LED module again Hot plug-in or secondary swihing of LEDs is not permitted and may cause a very high current to the LEDs. Expected life-time Type ta 40 C 50 C 60 C LC 45W 1050mA fixc C SNC 80 C 90 C x Life-time 50,000 h 30,000 h x The LED Drivers are designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. Life-time declarations are informative and represent no warranty claim. Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 Imax Time LC 45W 1050mA fixc C SNC 35 45 60 75 35 45 55 65 10 A 100 µs Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LC 45W 1050mA fixc C SNC 20 12 2 1 1 1 www.tridonic.com 3

Wiring diagram 220 240 V 50/60 Hz L N + + LED LED Umodule ô SEC Uconverter LC... C SNC PRI Wiring type and cross section The input wiring can be stranded wires with ferrules with a cross section of 0.5 1.5 mm² or with solid wires with a cross section of 0.5 2.5 mm². Strip 9 10 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. The output wiring can be done with a cross section of 0.5 1.5 mm². Strip 8.5 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Input wiring wire preparation: Solid: 0.5 2.5 mm² Fine-stranded: 0.5 1.5 mm² Output wiring wire preparation: 0.5 1.5 mm² Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 9 10 mm 8.5 9.5 mm Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Mains leads should be kept apart from LED Driver and other leads (ideally 5 10 cm distance) lenght of output wires is 2 m. Secondary swihing is not permitted. Incorrect wiring can demage LED modules. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, e.). Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Release of the wiring Press down the push button and remove the cable from front. Input terminal Output terminal Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 4

Diagrams LC 45W 1050mA fixc C SNC Efficiency vs load Power factor vs load Efficiency [%] 100 98 96 94 92 90 88 86 84 82 80 Power factor 1,00 0,98 0,96 0,94 0,92 0,90 0,88 0,86 0,84 0,82 0,80 Input power vs load Input current vs load Input power [W] 55 50 45 40 35 30 Input current [ma] 240 230 220 210 200 190 180 170 160 150 140 THD vs load THD 20 18 16 14 12 10 8 6 4 2 0 www.tridonic.com 5