Electromechanical Level Measurement Systems silopilot FMM 760, FMM 760 Z

Similar documents
Level Measurement silometer FMC 420, FMC 423

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Level Measurement Electronic insert FEC 12

Process transmitter RMA422

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Single Point Flow Monitor SW118 SW119

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Process Transmitter RMA 422

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

FLOMAT Electromagnetic Insertion Flowmeter

Mechanical flow switch for On/Off control

Lt DELTA USA, Inc

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Modular Lube Lubrication Systems System Controls

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Speed sensor MiniCoder GEL 2471

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Panel-mounting thermostats, type series EM

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Gear Pump Units For single-line centralized lubrication systems

Quality products from a single source

DMP 331i / DMP 333i LMP 331 i

Inductive sensor BI1.5-EG08K-Y1

HOG 86. The incremental HeavyDuty encoder for highest demands

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

TRF STEP-DOWN TRANSFORMER USER MANUAL

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Tube Rotator. User Guide. Version 1.2

Absolute Encoders Multiturn

2.9 Sigma/ 2 Plunger Metering Pumps

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

15 Series - Dimmer

800 Displaying Series Flowmeter

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Inductive sensor NI3-EG08K-Y1-H1341

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

3 Cleaning. 4 Technical data

Inductive sensor NI10-M18-Y1X-H1141

Horn loudspeaker, Ex proof, short/long flare

Quality products from a single source

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Modular pulse operated latching relay 16 A

Catalogue Ignitors and power switches for HID

DLP200M 2 Relay Module for Heating and Cooling Plants

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Installation instructions Cable transit device Roxtec RS ES Ex

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Liquid Level Sensor Type AKS 4100U

10 PDUs 19 PDUs Zero-U PDUs

7 Lighting Technology

Wall-/Pipe-Mount Level Indicator

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Linear encoders without bearings incremental System for linear motion feedback

Admiss. counterpressure

Liquid Level Sensor AKS 4100U

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Liquid Level Sensor Type AKS 4100/4100U

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Level Measurement Point level measurement - RF Capacitance switches

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Read and understand this manual for safely usage.

EXPlora. Introduction

Multifunction devices

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Liquid Level Sensor AKS 4100U

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Features. Specifications. Finish. Notes

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Transcription:

Technical Information TI 280F/00/en Electromechanical Level Measurement Systems silopilot FMM 760, FMM 760 Z Level measurement system of high versatility for bulk solids and liquids Application The Silopilot FMM 760, FMM 760 Z is an electromechanical level measurement system. Appropriate weights, which sense the surface of the product, are available to suit the application. Depending on the weight selected, the level of product in silos or bunkers can be measured, whether the product be dusty, fine or coarse-grained. The level of liquids in tanks can also be measured. Versions of the Silopilot FMM 760 are available for level measurement in silos or tanks with an operating temperature up to 150 C, at an operating pressure up to 2 bar or in aggressive atmosphere, e. g. acid vapour. Silopilot FMM 760 with standard sensing weight Features and Benefits Measurement of levels up to 70 m independent of product properties Accuracy of ±1 pulse, therefore precise detection of the level Electronic minimum fail-safe mode, therefore no running down of the sensing weight into the silo outlet, no damage of conveying systems Lifting power up to 850 N, therefore reliable lifting of the sensing weight Manual or automatic operation with remote start and indication, therefore ideal device for automatic silo control and monitoring Compact design, quick and economic mounting, easy maintenance Version FMM 760 Z with BVS certificate for application in dust explosion hazardous areas Zones 10 and 11. Endress +Hauser The Power of Know How

Measuring System A complete measuring system comprises: Silopilot FMM 760 with sensing weight Controller ZAD 423 or subtracting electromechanical counter ZCD 151, ZCD 152, ZCD 155 or ZCD 156 Connected peripherals, such as signalling systems, registration units, etc. The module concept allows electrical and mechanical components to be combined to create a system entirely appropriate to the application requirements (see section Product Structure ). Silopilot FMM 760 Sensing weight Power supply Controller ZAD 423 Measuring system with controller ZAD 423 Measurement Principle A measuring tape with a sensing weight attached to the end is driven down into the bunker. When the weight touches the surface of the product, the tape slackens and the motor reverses. The weight returns to the start parked position. During the downward or upward movement of the weight, the Silopilot emits pulses equivalent to the length of the extended tape. The pulses are recorded by the controller ZAD 423 or by an electromechanical counter. The measured value is stored until the next measuring cycle. This is initiated by a start button or a timer. Versions Version FMM 760 Z (Dust-Ex) For application in flammable dust hazardous areas Zones 10 and 11. Mechanical and Electrical Versions With heating: Thermostatically controlled, electrical housing heater 230 V, 50/60 Hz for ambient temperatures to 45 C (indicate min. ambient temperature when placing an order). Also recommended for moist vessel and ambient temperature below 0 C. Pressure-tight up to 2 bar silo gauge pressure. Climatic protection: All metal parts coated against acids, alkalis, humidity and heat. Stove enamelled: Cover and housing base stove enamelled. High temperature version: All parts within silo temperatureresistant up to 150 C. With weather protection cover (this is also available separately, see Sect. Accessories ). Minimum Fail-Safe Function Optional electrical function that causes a descent limiting of sensing weight. Signal Function for Tape Running and Control Maximum four of the following output signals may be selected: Upper parked position of sensing weight Tape break alarm Tape reverse / slack band Descent of sensing weight Ascent of sensing weight Energising the circuit for minimum fail-safe mode. Sensing Weights See section Sensing Weights. Other Options Counting step and tape length Metal parts in silo and tape-wipe mechanism Power supply for control and motor. For a complete list of available versions refer to Sect. Product Structure. 2

Planning and Installation Installation Site Select an installation site on the silo roof where flowing or falling product cannot cover the sensing weight or damage the measuring tape. Take into consideration the shape and position of the inflow cone and the outflow funnel. The sensing path should not cross internal fixtures that may touch the tape. Inflow Silopilot FMM 760 Silopilot FMM 760 100% Free space Free space Build-up at the vessel wall * Product cone X% * Slope Y% *Select a measuring point at the approximate mid point of the slopes. Outflow funnel 0% Selecting installation site Selecting installation site Mounting Preparation The Silopilot FMM 760 is mounted on a counter flange C 100 x d 1 DIN 2633 or a flange of the same connecting dimensions. The flange must be mounted exactly horizontally and the pipe on that it is welded should be exactly vertical. The pipe should be as short as possible. If it must be longer than 200 mm, e. g. because of a thick silo roof or a high operating temperature, then order the Silopilot with extended tape-wipe mechanism (500 or 1000 mm). When installing outside, fit a weather protection cover or roof (see Sect. Accessories ) over the Silopilot. 3

1 1 2 2 3 3 4 4 5 5 6 6 1 1 2 2 3 3 4 4 5 5 6 6 Electrical Connection Connection of Motor and Control voltages Connecting a Silopilot FMM 760 with three-phase or single-phase motor, respectively: see Figs. Max. cable cross section for the terminals: 4 mm 2. Fuse: mains cables max. 10 A. Motor/control separated Terminals for motor and control voltage Terminal block A Connection Silopilot FMM 760 with three-phase motor Control Motor L1 N PE N L3 L2 L1 PE max. 10 A (SL) max. 10 A max. 10 A max. 10 A (SL) (Ph) (Mp) (Mp) (T) (S) (R) Control Motor Motor/control separated Terminals for motor and control voltage Terminal block A Control L1 N PE max. 10 A (SL) (Ph) (Mp) Control Motor L1 N max. 10 A (Ph) (Mp) Motor Connection Silopilot FMM 760 with single-phase motor PE (SL) Connection of Control and Alarm systems All corresponding connections are located on terminal block B; see Fig. Max. cable cross section for the terminals: 2.5 mm 2. Separate cables for external start and start disabling from signal and supply cables. Connection of control and alarm systems Terminal block B Z G R Z G R a u r a u r a u r a u r a u r 1 2 3 4 5 6 7 8 9 10 Signalisations 11 12 13 50 51 52 53 54 55 56 57 58 59 60 61 Start disable Starter button ext. Counting circuit Counting circuit Motor overload Options see Techn. Data max. 250 V,4 A 250 VA, cos j =1 max. 250 V,4 A, 1000 VA, cos j =1 4

Sensing Weights Oval float (for FMM 760 only) Umbrella weight Normal weight Bag weight Cage weight Bell weight Variants The following shapes are available and will be described on the following pages: Normal cylindric sensing weight with spike Umbrella weight Bag weight Cage weight Oval float (for FMM 760 only) Bell weight. Selection Observe the following points when selecting the sensing weight: The sensing weight must neither sink into the product nor slip on the cone during measurement. The sensing weight must match the chemical product properties and the temperature in the bunker. Special versions for particular applications are available on request. Mounting Normal weight, umbrella weight and bag weight can be introduced into the bunker through the DN 100 mounting flange. The measuring tape is pressed into the tape assembly by two screws. A third screw takes the chain. At the lower part of the chain, a rotating bush is located. Its function is to absorb the rotations of the sensing weight. In standard version, the weight fastening (tape assembly, chain and rotating bush) is made out of galvanised steel. However, the parts are as well available in a special version of stainless steel. The measuring tape is made out of stainless steel also in standard version. 5

Sensing Weights (continued) Normal Weight Application: For coarse-grained solids, e. g. coal, ore or stones, and for granules. The spike can be unscrewed. If a crusher or mill is connected to the bunker, then we recommend the electrical signal function tape break or the use of a cage weight. This will prevent damage of the plant in case of atapebreak. Materials: steel or stainless steel. Weight: 3.5 kg. 230 240 55 Screw and nut M6 Rotating bush Normal weight Spike (unscrewable) 8 Umbrella Weight Application: For very light and loose solids, e. g. flour or coaldust. The umbrella weight has a large square surface. This will prevent deep sinking into the product. In folded state, the weight can be introduced into the bunker through the DN 100 mounting flange. Max. permissible temperature: 100 C. Materials: steel or stainless steel, canvas. Weight: 3.5 kg. 220 235 55 8 Chain Rotating bush Spring wire Umbrella of canvas Edge 400 Weight body Spike Bag Weight Application: In bunkers to which e. g. mills are connected. The bag contains the product stored in the bunker. Max. permissible temperature: 100 C. Materials: bag of linen, loops reinforced by leather, all metal parts of stainless steel. Weight: empty 0.25 kg, filled 3.5 kg. Tie up the bag at the top. This will prevent the contents from falling out, if the bag is upset when hitting the slope of a product cone. approx. 300 Fastening at steel tape Rotating bush Steel rope Product bag approx. 150 6

Sensing Weights (continued) Cage Weight Application: For fine solids in silos with relatively small product outlet that must never be blocked by a broken sensing weight. Also suitable for high temperatures that do not allow the use of a bag. The weight can get stuck over the outlet, but lets the product pass. Since the cage cannot get into a conveyor system (e. g. cellular wheel feeder or screw conveyor), it will prevent consequent damage. Standard dimensions: see Fig. Other dimensions on request. Material: steel. Weight: 3.5 kg. approx. 370 400 194 384 Chain Rotating bush 8 Oval Float (for FMM 760 only) Application: For liquids, e. g. fuel oil, also for granules. Material: hard PVC. Max. permissible temperature: 60 C. The float must be filled with product up to the total weight of 3.5 kg. Float Chain Rotating bush 315 Bell Weight Application: For light and loose solids; especially in cases where high temperatures and particular product properties do not allow the use of an umbrella weight. Materials: steel or stainless steel. Weight: 4.3 kg. Chain Rotating bush 300 Bell 300 7

Product Structure Silopilot FMM 760, FMM 760 Z Counting steps / tape length A Pulse per 1 dm, tape length 25 m B Pulse per 1 dm, tape length 50 m C Pulse per 1 dm, tape length 70 m D Pulse per 0.5 dm, tape length 25 m E Pulse per 0.5 dm, tape length 50 m F Pulse per 0.5 dm, tape length 70 m G Pulse per 1 in, tape length 25 m H Pulse per 1 in, tape length 50 m J Pulse per 1 in, tape length 70 m K Pulse per 1 / 10 ft, tape length 25 m L Pulse per 1 / 10 ft, tape length 50 m M Pulse per 1 / 10 ft, tape length 70 m N Pulse per 1 cm, tape length 10 m Y Special version on request Minimum fail-safe function 0 Without minimum fail-safe function 1 With minimum fail-safe function 9 Special version on request Signal function for tape running and control 00 Without additional status message relays 01 One relay for maximum message 02 One relay for tape break message 04 One relay for tape reverse message 08 One relay for descent message 16 One relay for ascent message 32 One relay for minimum message Combinations are defined by addition of the codes. Maximum 4 functions can be combined. Metal parts in silo and tape-wipe A Metal parts of steel, tape-wipe short, of cast aluminum K Metal parts of steel, tape-wipe 500 mm long, of cast aluminum L Metal parts of steel, tape-wipe 1000 mm long, of cast aluminum B Metal parts of 1.4571, tape-wipe short, of cast aluminum C Metal parts of 1.4571, tape-wipe 500 mm long, of cast aluminum D Metal parts of 1.4571, tape-wipe 1000 mm long, of cast aluminum E Metal parts of 1.4571, tape-wipe short, of 1.4571 F Metal parts of 1.4571, tape-wipe 500 mm long, of 1.4571 G Metal parts of 1.4571, tape-wipe 1000 mm long, of 1.4571 Y Special version on request Mechanical and electrical variants 00 Without additional features 01 With heating 230 V, 50/60 Hz 02 Pressure-tight up to 2 bar 04 With climatic protection 08 Stove enamelled 16 High temperature version 32 With weather protection cover Combinations are defined by addition of the codes. Power supply for control Q Power supply 575 V, 50/60 Hz P Power supply 550 V, 50/60 Hz N Power supply 500 V, 50/60 Hz T Power supply 440 V, 50/60 Hz S Power supply 415 V, 50/60 Hz R Power supply 400 V, 50/60 Hz J Power supply 240 V, 50/60 Hz E Power supply 230 V, 50/60 Hz G Power supply 127 V, 50/60 Hz F Power supply 115 V, 50/60 Hz B Power supply 110 V, 50/60 Hz C Power supply 48 V, 50/60 Hz K Power supply 42 V, 50/60 Hz D Power supply 24 V, 50/60 Hz Y Special power supply on request FMM 760 FMM 760 Z Product designation, first part Continued on next page Product designation, first part Continued on next page 8

Product Structure (continued) Silopilot FMM 760, FMM 760 Z Power supply for motor Q Three-phase motor 3 575 V, 50 Hz N Three-phase motor 3 500 V, 50 Hz L Three-phase motor 3 440 V, 50 Hz J Three-phase motor 3 415 V, 50 Hz G Three-phase motor 3 400 V, 50 Hz 1 Three-phase motor 3 230 V, 50 Hz C Three-phase motor 3 127 V, 50 Hz W One-phase motor 240 V, 50 Hz 2 One-phase motor 230 V, 50 Hz 3 One-phase motor 115 V, 50 Hz R Three-phase motor 3 575 V, 60 Hz P Three-phase motor 3 500 V, 60 Hz M Three-phase motor 3 440 V, 60 Hz K Three-phase motor 3 415 V, 60 Hz H Three-phase motor 3 400 V, 60 Hz 4 Three-phase motor 3 230 V, 60 Hz D Three-phase motor 3 127 V, 60 Hz X One-phase motor 240 V, 60 Hz 5 One-phase motor 230 V, 60 Hz 6 One-phase motor 115 V, 60 Hz Y Special version on request Sensing weight 0 Without sensing weight 1 Standard sensing weight of steel 2 Sensing weight of 1.4571 3 Umbrella weight of steel / canvas 4 Umbrella weight of 1.4571 / canvas 5 Linen bag weight 6 Cage weight of steel 7 Oval float of hard PVC (for FMM 760 only) 8 Bell weight of steel 9 Special version on request FMM 760 Complete product designation FMM 760 Z Complete product designation Prefered Packages Silopilot FMM 760 with standard sensing weight of steel and with controller ZAD 423 Order No: Used options of Silopilot FMM 760: 941260-0000 Counting: 1 dm, Tape: 50 m Minimum level alarm included 3 relays (maximum, breakage, tape reversal) Tape wipe 300 mm, steel parts With sun protection cover Power supply, control: 230 V AC Motor: three-phase 3 x 400 V AC, 50 Hz Used options of controller ZAD 423: For non hazardous area MINIPAC housing 100 mm with terminal block Power supply: 230 V AC same version as before but with linen bag weight 941260-0010 9

Technical Data General Specifications Manufacturer Endress+Hauser GmbH+Co. Instrument designation Silopilot FMM 760, FMM 760 Z Operation and System Design Measurement principle During the movement of a measuring tape, pulses are emitted and registered. Their number is proportional to the filling level. Modularity Silopilot FMM 760, FMM 760 Z with sensing weight, controller ZAD 423 or subtracting electromechanical counter, connected peripherals (e. g. signalling systems or registration units) Input Variables Measured variable Filling level for bulk solids and liquids Counting steps (options) Measuring ranges (options) Sensing velocity (at 50 Hz mains frequency) 1 dm, 0.5 dm, 1 in, 1 / 10 ft, 1 cm counting step 1 cm: 10 m, otherwise: 25 m, 50 m, 70 m counting step 1 cm: approx. 8 10 cm/s, otherwise: approx. 20 35 cm/s Output Variables Output signals potential-free change-over contact Accuracy Measured error max. ±1 pulse Application Conditions Installation Installation instructions Lifting capacity see Sect. Planning and Installation three-phase motor: briefly 850 N, one-phase motor: briefly 150 N Environment Ambient temperature 20 +60 C, version from 45 C in preparation Ingress protection IP 55 Electromagnetic Compatibility Interference Emission to EN 61326, Electrical Equipment Class B Interference Immunity to EN 61326, Annex A (Industrial) and NAMUR Recommendation NE 21 (EMC) Use a screened cable between the sensor and transmitter. Refer to TI 241F for installation instructions pertaining to screened cables and general instructions on EMC test conditions for E+H equipment. Process Product temperature 20 +80 C, version up to +150 C, with oval float up to +60 C Limit process pressure range 0 bar, version 2 bar Construction Design see Sects. Versions and Product Structure Dimensions Weight Materials see Sects. Dimensions and Sensing Weights without sensing weight: approx. 31 kg normal weight: 3.5 kg cage weight: 3.5 kg umbrella weight: 3.5 kg oval float: 3.5 kg bag weight: empty 0.25 kg bell weight: 4.3 kg filled 3.5 kg housing: aluminium protection cover: enamelled sheet steel metal parts in silo and tape-wipe: see Sect. Product Structure measuring tape: special corrosion-resistant spring steel sensing weights: see Sects. Sensing Weights and Product Structure Power Supply Power supply for control (options) Power supply for motor (options) Power consumption 575 V, 550 V, 500 V, 440 V, 415 V, 400 V, 240 V, 230 V, 127 V, 115 V, 110 V, 48 V, 42 V, 24 V, 50/60 Hz each, mains voltage tolerance +15%, 10% three-phase motor: 3 575 V, 3 500 V, 3 440 V, 3 415 V, 3 400 V, 3 230 V, 3 127 V, 50 or 60 Hz each, mains voltage tolerance ±10% one-phase motor: 240 V, 230 V, 115 V, 50 or 60 Hz each, mains voltage tolerance ±10% control max. 70 VA, motor max. 300 VA 10

Technical Data (continued) Certificates and Approvals Dust ignition protection version FMM 760 Z for application in dust explosion hazardous areas Zones 10 and 11 BVS certificate No. St Ex 6/81 B dated July 29th, 1981 Dimensions free space to remove cover min. 400 80 460 Flange mounted on counter flange C 100 x d 1 DIN 2633 or flange of same connecting dimensions approx. 250 approx. 450 approx. 920 420 20 98 255 180 75 170 Dimensions Silopilot FMM 760 with normal sensing weight 185 Accessories Weather protection of white plastic (ASA 776) metal parts of stainless steel ambient temperature max. +60 C dimensions (H W L): 415 285 478 mm Controller ZAD 423 Subtracting electromechanical counters ZCD 151, ZCD 152 ZCD 155, ZCD 156 Sensing weights see Sect. Sensing Weights 11

Accessories (continued) Weather protection cover Counter ZCD 151, 152 Controller ZAD 423 Counter ZCD 155, 156 Supplementary Documentation Controller ZAD 423 Technical Information TI 277F/00/en Counter ZCD 151, ZCD 152 Technical Information TI 11.73.04 Counter ZCD 155, ZCD 156 Technical Information TI 08.78.01 Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 9 75-02 Tx 773926 Fax (07621) 975-345 http://www.endress.com info@ii.endress.com 08.99/MTM TI 280F/00/en/06.01 EHF/CV5