(with. Meets. tools. Page 1 of 11

s (with up to 250 MHz Patent pending Page 1 of 9

Enterprise Solutions Catalog 2007/8

Connect with the industry s best CAT6 and CAT5e channel solutions!

CATEGORY 6A CABLING SOLUTIONS

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

CATEGORY 6 CABLING SOLUTIONS

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

CATEGORY 6A CABLING SOLUTIONS

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

DINTEK LAN Cabling Systems

CATEGORY 5e CABLING SOLUTIONS

Cat.6 4 Pair UTP Cable

What really changes with Category 6

HighBand 25. TrueNet Category 6 Solutions

PREMIUM 5e F/UTP PRODUCTS

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Data Centre & Communications Room. Category 6. Data Centre & Communications Room. 1 0 / B E TrueNet Structured Cabling

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

1x12 VGA & Audio over CAT5 Splitter

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

STRUCTURED CABLING SYSTEMS (SCS)

Magic Patch Patch Leads & Accessories

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

Lab - Build and Test Network Cables

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

DS1 Cross-Aisle Panel

XTENDEX Series. ST-C6DVI(A)-300 ST-C6DVI(A)-IR FOOT DVI VIDEO, AUDIO AND IR EXTENDER Installation and Operation Manual

HDMI EXTENDER ELE8088

VGA & Audio over CAT5 Distribution Series

Ethernet to VGA over IP Converter

384A Adapter Installation Instructions

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

LCS2 Cat. 6 RJ 45 Patch panels and units

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

Copper Solution Contents Cabinets Fiber Optic Solution

User s Manual. Digital Media Converter Package Part #: DL-HDCAT-WP

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

HDMI Over IP Extender Kit - 4K

PATCH CORDS, PLUGS & CABLES

Advantech Proudly Presents Professional Monitor Series

STRUCTURED CABLING SOLUTIONS

VGA, Audio & RS-232 Serial with IR Pass-Thru over Single CAT5 /RJ45 Extender Kit

Perle Fast Ethernet Media Converters

Infinite ways to link... Solution Catalog

Lab Building Straight-Through and Crossover UTP Cables

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

CAT 6 Data Wiring System Connectors

SPECIAL SPECIFICATION 2344 TMC Support Equipment

The HellermannTyton AlphaSnap patch panel features the ultimate in patch panel technology. In addition to providing superior performance levels, the

HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K

...Infinite Ways to Link...

CAT 6 Data Wiring System Connectors

TP VGA/COMPONENT+ AUDIO TWISTED PAIR (UTP) TRANSMITTER

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

MultiView T4 / T5 Transmitter

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

Multi-Media Installation Guide

Clarity Advanced Solutions6A

Perle Fast Ethernet Media Converters

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

HDMI over CAT5 HDBaseT Extender - 4K

EXTENDER ELE8080. INSTALLATION Manual. Made in Taiwan

User Manual rev: Made in Taiwan

TX COPPER CABLING SYSTEM

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Mar11 Rev E

LCS 2 RJ 45 Cat. 6A HD panels and units

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

T/E-Extender TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

SECTION 686 VIDEO DECODER DESCRIPTION

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

DVI over Single CAT5 Series CV-117. DVI over Single CAT5 Direct Plug-in Extender. User Manual. Made in Taiwan

HDMI / Video Wall over IP Receiver with PoE

SPECIAL SPECIFICATION 8494 CCTV Central Equipment

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

What is HDBaseT? Extend more with HDBaseT. HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K ft (70m) StarTech ID: ST121HDBTE

Belden IBDN System 10GX 10GX Modules and 10GX Patch Panels

Everything you always wanted to know about HDBaseT*

HDMI over Two CAT5/6 Extender with IR Control Path

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

PT-TX400 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

DISTRIBUTION AMPLIFIER

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

Transcription:

Features Support 24 ports per 1U, 48 ports per 2U. Conform to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. Simple labor-saving termination using standard 110 Block termination and Krone tools Enhanced cable retention fixture Unique assembly fixture Color coded wiring blocks, compatible with both T568A and T568B wiring options Backward compatible with Category 5e and Category 5 cabling standards Supports solid 22-24 AWG wires and stranded 24-26 AWG PatchView and non-patchview options Page 1 of 8

Features CLASSix RiT SMART CLASSix UTP Patch Panels are part of the RiT SMART CLASSix Cabling System TM, featuring Category 6 performance. The system is designed to conform to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. PatchView Capability Special SMART CLASSix UTP 24/48 Patch Panels models, when used in conjunction with RiT's PatchView System, are able to scan the wiring center configuration and subsequently report the connectivity status Patching information is displayed on the management station for cabling management applications LED indicators on panels identify any two ports patched together. Extremely useful for facilitating maintenance in mid-to-large size wiring centers which are over congested with patch cords. Computerized LED displays guide the technician when performing Moves, Adds and Changes (MACs) Page 2 of 8

Description The RiT SMART CLASSix UTP line of data communications patch panels meets the requirements for high-performance Category 6 network components. The panels conform to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E, and are designed for high-speed applications such as ATM 622 Mbps, Gigabit Ethernet 1000 Mbps and future high-speed applications. The panels are optimized for ease of assembly and termination. With simple labor-saving termination using standard 110 Block termination and Krone tools and color-coded wiring blocks, installation costs are significantly reduced. A unique assembly fixture is available for supporting the panel during assembly. Special SMART CLASSix UTP models, when used in conjunction with RiT's PatchView system, are able to perform remote or on-site scanning of the patching configuration. The entire wiring center's patching configuration is continuously monitored by a scanner which reports the data to a remote terminal. The network administrator uses this data as a vital part of his cabling management system. The data may be displayed on the panel itself by LED indicators. Servicing time is dramatically reduced as computerized LED displays guide the technician when performing Moves, Adds and Changes (MACs). Page 3 of 8

Interface Front Interconnection (patch cord side) 24/48 eight-position or nine-position RJ-45 unshielded modular jacks. Use of patch cords with RiT CLASSix RJ-45 plugs is recommended. Back Interconnection (cabling side) 24/48 eight-position 110 tool-compatible blocks, accept 22-24 AWG wires and stranded 24-28 AWG wires. Rated for up to a minimum of 200 retermination Note: Termination tools must be ordered separately. Cable Routing and Clamping An optional cable retention fixture is available for enhanced cable strain relief using cable ties. 4.8mm wide ties, such as PANDUIT P/N PLT 25, are recommended. Cables-ties can be ordered from RiT. Interconnection to RiT's PatchView system (in selected models) Two 14-pin headers on the back of the PV panel are used for connection to PatchView Scanners. There is only one 14-pin header on PVMax panels. Select Scanner to Group B Patch Panel Attachment Cord according to the required length. The scanning signal is transmitted over pin 9 of the RJ-45. Pin 9 exists in nine-position RJ-45 jack and plug designs, used for these patch panel models. A special patch cord, SMART Jumper, including an extra wire and special RJ-45 plugs is needed. Indicators (in models adapted to PatchView only) Port identification indicators - 24/48 red LEDs. Connected ports are identified by a pair of activated LEDs. A single port can be identified and the corresponding LED activated by a remote control command from the network management station. Page 4 of 8

Electrical Category 6 / CLASS E Standard Conforms to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. Performance Requirements Meets all connecting hardware requirements Electrical SMART CLASSix UTP Patch Panel PowerSum NEXT ratio plot is shown for worst pair. The following are typical Power Sum NEXT measurement results at 100, 200 and for all pairs. Pair (to all PowerSum NEXT (db) other pairs) 100 200 1-2 -60.0-50.3-46.4 3-6 -56.3-48.3-44.9 4-5 -55.8-50.6-48.0 7-8 -58.9-51.1-48.3 All pairs exceed Category 6 requirements. Page 5 of 8

NEXT ratio plot is shown for worst pair combination. The following are typical NEXT measurement results at 100, 200 and for all pair combinations. Pair NEXT (db) Combination 100 200 1-2 & 3-6 -62.7-52.5-48.3 1-2 & 4-5 -63.6-55.2-51.9 1-2 & 7-8 -74.8-61.9-58.1 3-6 & 4-5 -58.6-54.1-51.8 3-6 & 7-8 -63.4-52.7-49.7 4-5 & 7-8 -60.9-57.4-55.6 All pairs combinations exceed Category 6 requirements. PowerSum FEXT ratio plot is shown for worst pair. The following are typical Power Sum FEXT measurement results at 100, 200 and for all pairs. Pair (to all PowerSum FEXT (db) other pairs) 100 200 1-2 -47.1-41.1-39.3 3-6 -61.1-48.5-45.9 4-5 -43.8-37.2-35.1 7-8 -46.4-39.4-37.2 All pairs exceed Category 6 requirements. Page 6 of 8

SMART CLASSix 48 1 UTP Patch Panels (High Dendity) - FEXT ratio plot is shown for worst pair combination. The following are typical FEXT measurement results at 100, 200 and for all pair combinations. Pair FEXT (db) Combination 100 200 1-2 & 3-6 -71.8-57.0-54.5 1-2 & 4-5 -47.1-41.3-39.5 1-2 & 7-8 -66.9-58.3-55.4 3-6 & 4-5 -68.5-50.9-48.1 3-6 & 7-8 -62.4-54.1-51.6 4-5 & 7-8 -46.5-39.6-37.4 All pair combinations exceed Category 6 requirements. Return Loss ratio plot is shown for worst pair. The following are typical Return Loss measurement results at 100, 200 and for all pairs. Pair (to all Return Loss (db) other pairs) 100 200 1-2 -37.9-30.8-28.1 3-6 -35.9-27.2-24.4 4-5 -27.2-21.0-19.1 7-8 -41.6-32.0-28.6 All pairs exceed Category 6 requirements. Page 7 of 8

Patch Panels Insertion Loss ratio plot is shown for worst pair. The following are typical Attenuation measurement results at 100, 200 and for all pairs. Pair (to all Insertion Loss (db) other pairs) 100 200 1-2 0.00152-0.0557-0.14 3-6 -0.00594-0.0623-0.16 4-5 0.0178-0.0903-0.26 7-8 -0.00648-0.0658-0.1 All pairs exceed Category 6 requirements. General Physical 24 Ports 48 Ports Height: Width: Depth: Depth with Cable Retention Fixture: Weight: 44.0 mm / 1.75" (1U) 482.6 mm / 19" 35.0 mm / 1.375" 91.0 mm / 35.8" 0.46 kg (1.0 lb) 88.0 mm / 3.5" (2U) 0.92 kg (2.02b) Material Aluminum Colors Black background with gray silk screened markings Environment Temperature:-40 to 85 C Humidity: 0-90% non-condensing Page 8 of 8