E3/DS3 Fibre Extender

Similar documents
Manual and Installation guide

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Model 1421 Distribution Amplifier

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 673T HD-SDI Optical Transmitter. 673R HD-SDI Optical Receiver. P/N: Rev 6

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 9

Fibre Optic Modem ODW-622

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

HDMI Extender Via One MPO Fiber MPO Connector Extends HDMI Link Up To 200 Meters

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

Power Injector 1520 Series

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

I N S T R U C T I O N D A T A

Multi-Channel Passive Transceiver Hubs Installation Sheet

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Perle Fast Ethernet Media Converters

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

LONWORKS Fibre Optic Router

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

Fibre Optic Modem ODW-611

ODW-621. RS-232 Point-to-point applications

HD-One DX/DX500 HDMI Extender

Fibre optic router for TP/FT-10 LRW-112PP

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 5

LONWORKS Fibre Optic Converter

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Perle Fast Ethernet Media Converters

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

USER MANUAL. TP-141 XGA/Audio Line Transmitter. TP-142 XGA/Audio Line Receiver MODEL: P/N: Rev 6

Features. CPU Version. Non-CPU Version

DISTRIBUTION AMPLIFIER

ACTIVE IF SPLITTER/COMBINER UHP-IFS

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Instruction Manual Model # Block Upconverter

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

USB-0100TX USB Fast Ethernet Converter. User s Guide

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

FiberLink 7142 Series

TP /351 HDMI Over Coax with IR

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

Kramer Electronics, Ltd. USER MANUAL. Models: 622T, Dual Link DVI Optical Transmitter 622R, Dual Link DVI Optical Receiver

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

One channel video link With duplex data and contact closure

EXT-HBT70-SET_2016V1.2

MONOPRICE. Blackbird 4K Pro HDBaseT Extender Kit. User's Manual P/N 21609

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

USER MANUAL. PT-571HDCP DVI Line Transmitter. PT-572HDCP+ DVI Line Receiver MODELS: P/N: Rev 8

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

HD1-LX HDMI & IR Extender

MultiView 9D Cat5 Distribution Amplifier

User s Manual. Document # , Rev 1.2, 6/12/2006

User Guide. HDMI Active Cable Extender. DVI-7370c

User Manual HDMI-EXT-501CO. HDMI Extender over Single Coax with Bi-directional IR 7.1 CH AUDIO. rev: Made in Taiwan

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

MONOPRICE. BitPath AV HDMI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16228

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

FiberLink 3355 Series

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

MONOPRICE. Blackbird 4K HDMI Extender. User's Manual P/N 24281

TC3301. User's Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Instruction Manual Model BlockUpconverter

USER MANUAL. VM-10HDxl 3G 1:10 HD/SD SDI Distribution Amplifier MODEL: P/N: Rev 2

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

User s Manual. Digital Media Converter Package Part #: DL-HDCAT-WP

POC2052-4P-1CX PoE Over Coaxial Extender User Manual

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

MultiView T4 / T5 Transmitter

User Guide FA

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

4 x 4 VGA Matrix Switch

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

FiberLink 3350 Series

SAM64 SDI to AES/MADI interface

DA1931CT/ TP to Video + Audio Receiver

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Transcription:

User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk

CONTENTS 1 Introduction 1 1.1 About the products 1 1.2 Safety 2 1.3 Electromagnetic Compatibility 2 1.4 EN55022 Declaration 2 1.5 FCC Declaration 2 1.6 WEEE Directive 2 1.7 Power Supply 3 2 Unpacking & Installation Procedure 5 2. 1 Unpack and inspect the equipment. 5 2. 2 Optional rackmounting procedure 5 2. 3 Power up the FC unit 6 2. 4 Connect the Customer and Network ports. 6 2. 5 Optionally connect the alarm relay 6 3 E3/DS3 to Fibre converter 7 3.1 Rear panel 7 3.1.1 Power connector 7 3.1.2 External alarm relay 7 3.1.3 LED Alarms 8 3.1.4 Unbalanced BNC E3/DS-3 G.703 Customer port 8 3.2 Base panel & bit-switches 9 3.2.1 E3/DS-3 10 3.2.2 Test Loop 10 3.2.3 Line Build out 10 3.2.4 Scrambler - current version serial no 60128 and above 10 3.2.5 3.3 Scrambler - old version serial no 60127 and below Specifications 10 11

Introduction 1 INTRODUCTION 1.1 About the products The Black Box range of Fibre Converters tabulated below provide a simple economic way of converting from one type of transmission medium to another. Examples include: Electrical signals on copper to optical signals on fibre, and vice-versa. Single-mode optical fibre to multimode and vice-versa. Model Customer Interface Line Interface MTU9230 E3/DS-3 G.703 via BNC 75 ohm Dual SC Multi-mode fibre MTU9240 E3/DS-3 G.703 via BNC 75 ohm Dual SC Single-mode short haul fibre 1

Introduction The MTU9230/MTU9240 have been designed to be plug and go, conforming to appropriate standards, physically very compact, and rack mountable in sets of 2 using a dual face plate, or 18 units in a rack mount kit for large installations. FC units often enable substantial savings to be made in cable costs by utilising the cheapest effective cable type without incurring the costs of additional router or switch interfaces. We are continually developing new models, so if the interface combination required is not listed in this guide, please contact us. 1.2 Safety Where electrical signal cabling is connected to the units, do not connect to cabling which would be required by BS6701 to be equipped with over-voltage protection. Electrical signal ports should only be connected to SELV ports on other equipment in accordance with EN60950 clause 2.3. 1.3 Electromagnetic Compatibility In order to ensure EMC compliance all electrical signal and data cables and connectors must use a screened connector shell with a screened cable. The cable screen must be terminated to the screened connector shell and not connected to any pins of the connector. Failure to use the correct connector may compromise EMC compliance. 1.4 EN55022 Declaration FC units are a Class A product. In a domestic environment it may cause radio interference in which case the user may be required to take adequate measures. 1.5 FCC Declaration This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at its own expense. 1.6 WEEE Directive Both units are covered by Directive 2002/96/EC (OJ:L37/24/2003) on waste electrical and electronic equipment (The WEEE Directive). Units must therefore not be disposed of in a standard landfill. 2

Introduction 1.7 Power Supply Both units are powered by an internal mains-fed power supply. The mains input voltage is 100-250VAC, 50/400Hz. An alternative -48VDC power supply is available on all units as a custom order item. The power consumption of each model in the range is shown below, together with the current consumption over the operating voltage ranges. An alternative -48VDC or -24 VDC power supply is available on most units as a custom order item. The supply definition of the -48VDC supply is minus 36 to minus 72 VDC, 200-100 ma. DC power is supplied via a 3 pin Buccaneer socket fitted to the rear panel. The supply definition of the -24VDC supply is minus 12 to minus 36 VDC, 700-125 ma. DC power is supplied via a 2 pin Buccaneer socket fitted to the rear panel. The surrounding label is cloured blue for the -12V/-24 option. A Buccaneer plug is supplied with the unit for customer s own wiring. The connections are labelled on the rear panel of the unit as shown in the schematics below. Pin5 Pin1-48V Pin5 12-24V Pin2 0V Pin3 0V VDC IN 40-72V/200mA VDC IN 12-24V/700mA Figure 1. 3 Buccaneer DC sockets The units must be connected to safety earth for correct operation. The FC power supply should be connected to a supply socket that is physically located close to the unit and is easily accessible. The power consumption of the units is shown below, together with the current consumption over the operating voltage ranges. Product Watts Power Consumption 100-250 VAC Current Range ma -36 to -72 VDC Current Range ma -12 to -36 VDC Current range ma MTU9230 & MTU9240 6.0 60-25 200-100 600-200 power consumption 3

Introduction Safety Notes: Excessive voltages are present inside the unit. There are no user serviceable parts inside the unit, and the cover should not be removed by unqualified personnel. The unit must not be exposed to damp or condensing conditions. 4

Unpacking & Installation Procedure 2 UNPACKING & INSTALLATION PROCEDURE 2. 1 Unpack and inspect the equipment. The carton should contain a single unit and for UK models, a power cable. If there is any visible damage, do not attempt to connect the device. Contact your Supplier or Black Box Technical support for advice and assistance. 2. 2 Optional rackmounting procedure Rackmounting kit Part No MTU9000M-RACK may be used to mount two FC units side by side in a 19 rack. First remove the two rear panel screws securing each unit s lid. Fasten the 2 units to the rack mount adaptor plate using the screws that you have removed, as shown in the illustrations below. STM-1 MULTIMODE Alarm ALARM EXT STM1 G.703 Remove screw Remove screw Figure 2.1 Unit rear panel Then secure the rack mounting plate complete with the two units to the 19 rack using the locating holes at the ends of the adaptor plate. The recessed twin unit rack will accept either AC or DC FC models. STM-1 MULTIMODE STM-1 MULTIMODE Alarm Alarm ALARM EXT STM1 G.703 ALARM EXT STM1 G.703 Figure 2.2 Twin unit rack mounting If you wish to use the optional 18 unit mounting rack, instructions are provided with the rack, part number MTU9000M-18RACK-AC (AC Mains) or MTU9000M-18RACK-DC (DC Supply). 5

Unpacking & Installation Procedure 2. 3 Power up the units The unit requires 100-250 VAC, 50-60 Hz AC supply, drawing less than 50mA when operating. Alternatively, a -48VDC power supply is available as another option for all models. The DC power options are -36 to -72 VDC (-48VDC), or -12 to -36 VDC (-24VDC), using a Buccaneer type connector. See Section1 for further details on power consumption. Plug a power cable into the back of the unit and switch on. Check that the Alarm LED on the rear panel is illuminated red or green, flashing or steady. If the LED is off, power is not being supplied to the unit. 2. 4 Connect the Customer and Network ports. When all the ports are connected, the Alarm LED should give a steady Green display. Setup information for both models is contained in each section of this manual. 2. 5 Optionally connect the alarm relay Many units offer an Alarm relay to provide an external warning of problems which may arise. The interface is presented on an RJ45 connector, and offers both normally open and normally closed contacts. Maximum contact rating is 1.5 Amp at 125 VDC. Normal is the powered up, non-alarmed state. The connections are shown in the table below: Pin Contact 1 Normally closed 2 Normally open 3 Common 4 Not connected 5 Not connected 6 Not connected 7 Not connected 8 Not connected Figure 2.3 Alarm relay pinout 6

E3/DS3 to Fibre converter 5 E3/DS3 TO FIBRE CONVERTER 5.1 Rear panel The E3/DS-3 line is connected via a pair of BNC connectors on the rear panel. The fibre connection is via a Dual SC connector on the rear panel. LINE MULTIMODE Alarm ALARM EXT GRN OK 5.1.1 Power connector Figure 5.1 MTU9230 rear panel AC mains power is supplied via an IEC connector. The units have an integral power supply operating over the range 100-250 VAC. It draws less than 50mA of current when operating. Alternative -48 VDC and -24VDC power supplies are available. See Section 1 of this manual for further details of this option and consumption data. The units must be connected to safety earth for correct operation. The MTU9230 power supply should be connected to a supply socket that is physically located close to the unit and is easily accessible. 5.1.2 External alarm relay Both models offer an Alarm relay to provide an external warning of problems which may arise. The interface is presented on an RJ45 connector, and offers both normally open and normally closed contacts. Maximum contact rating is 1.5 Amp at 125 VDC. Normal is the powered up, non-alarmed state. The connections are shown in the table below: Pin Contact 1 Normally closed 2 Normally open 3 Common 4 Not connected 5 Not connected 6 Not connected 7 Not connected 8 Not connected Figure 5.2 Alarm relay pinout 7

E3/DS3 to Fibre converter 5.1.3 LED Alarms There is a single multi-state alarm LED mounted on the rear panel. Its status options are shown below: LED Status Indication Off No mains power present Red steady E3/DS-3 Alarm Red/Off flashing E3/DS-3 and Fibre Alarm Green/Off flashing Fibre Alarm Green steady Status OK Figure 5.3 LED status 5.1.4 Unbalanced BNC E3/DS-3 G.703 Customer port The customer equipment is connected to the BNC connectors at the rear of the unit: Pin Tip Ring Function Signal Shield Figure 5.4 BNC connection Cable lengths should be restricted to those defined below: Cable E3 Max Length (metres) UR202 180 155 RG59U 150 130 BT2002 160 140 BT2003 165 140 DS-3 Max Length (metres) Figure 5.5 Cable lengths Note: The total maximum attenuation of each of the cables attached to the BNC (network) port must not exceed 6dB when measured at 1024 MHz. The frequency/attenuation characteristic of the cables attached to this port shall follow a root frequency law. 8

E3/DS3 to Fibre converter 5.2 Base panel & bit-switches The base label and bit-switch set-up shown in Figure 5.6 below is the current version applicable to units with serial number 60128 and upwards. The earlier version shown in Figure 5.7 below applies to serial numbers 60127 and below. The key difference between the two versions is in the scrambler facility. This is explained below. Status LED Off Red steady Red/Off Flashing Green/Off Flashing Green steady Meaning No mains power present E3/DS-3 Alarm Fibre Alarm Status OK Status LED Off Red steady Red/Off Flashing Green/Off Flashing Green steady Meaning No mains power present E3/DS-3 Alarm Fibre Alarm Status OK MTU9230 E3/DS3 - MM MEDIA CONVERTER (AC) MTU9240 E3/DS3 -SM-SH MEDIA CONVERTER (AC) Serial No: Serial No: SPARE TEST LOOP OFF ON SCRAMBLER X^23 X^3 SPARE TEST LOOP OFF ON SCRAMBLER X^23 X^3 Bold Characters = Factory Default SELECT DS3 E3 LINE BUILD OUT DS3 ONLY <255 FT >255 FT Bold Characters = Factory Default SELECT DS3 E3 LINE BUILD OUT DS3 ONLY <255 FT >255 FT 17-08-558C(A) 17-08-564C(A) Figure 5.6 base label current examples Status LED Off Red steady Red/Off Flashing Green/Off Flashing Green steady Meaning No mains power present E3/DS-3 Alarm Fibre Alarm Status OK Status LED Off Red steady Red/Off Flashing Green/Off Flashing Green steady Meaning No mains power present E3/DS-3 Alarm Fibre Alarm Status OK MTU9230 E3/DS3 - MM MEDIA CONVERTER (AC) MTU9240 E3/DS3 -SM - SH MEDIA CONVERTER (AC) Serial No: Serial No: SPARE TEST LOOP OFF ON SCRAMBLER OFF ON SPARE TEST LOOP OFF ON SCRAMBLER OFF ON SELECT DS3 E3 LINE BUILD OUT DS3 ONLY <255 FT >255 FT SELECT DS3 E3 LINE BUILD OUT DS3 ONLY <255 FT >255 FT 17-08-558B 17-08-564B Figure 5.7 bas e label early examples 9

E3/DS3 to Fibre converter The base panel bit-switches must be set for correct operation as below: 5.2.1 E3/DS-3 This switch is set to specify the Customer side line type. The default setting is E3. 5.2.2 Test Loop This switch initiates an outside test loop on both ports 5.2.3 Line Build out This switch boosts the DS-3 signal strength for long lines of over 255ft. The default setting is <255 feet. 5.2.4 Scrambler - current version serial no 60128 and above The scrambler function modifies the E3/DS-3 line traffic with an algorithm designed to break up long strings of 1 s or 0 s so that clock synchronisation is not lost or degraded by the long strings. The traffic is unscrambled on arrival at the far end. Two scrambler algorithms are offered by setting the scrambler bit-switch, with the default option being X^23 and the alternative being X^3. Note that X^23 is the more powerful scrambler and should be used whenever possible, whilst X^3 is available for use for legacy reasons. 5.2.5 Scrambler - old version serial no 60127 and below The scrambler function modifies the E3/DS-3 line traffic with an algorithm designed to break up long strings of 1 s or 0 s so that clock synchronisation is not lost or degraded by the long strings. The traffic is unscrambled on arrival at the far end. The scrambler bit-switch offers either scrambler OFF or X^3 scrambling. It is recommended that where available, payload scrambling should also be enabled on the attached equipment, especially where framed or channelised data is used. 10

E3/DS3 to Fibre converter 5.3 Specifications Units E3/DS-3 Interface Jitter Tolerance Barrier Diagnostics MTU9230 Fibre interface Specification Port: G.703 compliant, Sensitivity -10dB. Interface type: BNC 75 Ohm unbalanced coax Line coding: E3: HDB3 DS-3: B3ZS E3 Bit rate: 34.368 Mbps +/- 20ppm DS-3 Bit rate: 44.736 Mbps +/- 20ppm Per G.823. EN 41003 compliant barrier provided on the E1 interface. Loop Test initiated by Bit-switch G.957, Dual SC Multi-mode 62.5/125 um Bit rate: up to 155.52Mbps Transmit power: -14 to -19 dbm Max Rx input power: -14 dbm Receive sensitivity: -14 to -30 dbm Optical loss budget: = -19-(-30) = 11dB MTU9240 Fibre interface G.957, Dual SC SH Single-mode 8/125 um (Short haul) Bit rate: up to 155.52Mbps Transmit power: -8 to -15 dbm Max Rx input power:-8 dbm Receive sensitivity: -8 to -31 dbm Optical loss budget: = -15-(-31) = 16dB Safety EMC EN41003, EN50082 EN55022, EN50082 Power supplies 100-250 VAC, 50-60Hz, 35 ma to 15mA or -40 to -72 VDC, 100 to 50mA -12 to -36VDC, 700 to 200mA See Section1 for power consumption detailed data Dimensions 202 x 132 x 44 mm (w x d x h) Enclosure only (1U ) 202 x 132 x 48 mm (w x d x h) Overall including feet Ambient Temperature 0degC to +50degC Storage Temperature Relative Humidity -20degC to +70degC 0% - 95% non condensing 11

Sales Technical Support E-mail Website 0118 965 6150 0118 965 6000 info@blackbox.co.uk www.blackbox.co.uk