Key Features and functions. General Description

Similar documents
Key Features and Functions. General Description

Ps Black (typ.) (typ.) Current Consumption

UA70-R. 20W Ps IMD < -47dB Red Field (without precorrection) 10Wrms shoulder < -36dBc (with precorrection)

20Wrms DVB-T/60W ps UHF Amplifier

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Modular Block Converter Systems

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

15D05A Broadband Solid State Power Amplifier

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Features. Gain Variation Over Temperature db/ C

Features. = +25 C, IF= 100 MHz, LO= +13 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

05E05A S-Band Solid State Power Amplifier

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

2W SDARS ECHO Repeater

Model /29S RF Splitter

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

NuPower Xtender TM VU4GX02 VHF/UHF Solid State Bidirectional Amplifier

X-Band Redundant LNB Systems

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Instruction Manual Model # Block Upconverter

AMIGO- 8VSB (ATSC) digital Modulator

DA : Series of Narrowband or Wideband Distribution Amplifiers

Features. = +25 C, IF= 100 MHz, LO = +17 dbm*

HMC814LC3B FREQ. MULTIPLIERS - ACTIVE - SMT. SMT GaAs MMIC x2 ACTIVE FREQUENCY MULTIPLIER, GHz OUTPUT. Features. Typical Applications

v SUCCESSIVE DETECTION LOG VIDEO AMPLIFIER (SDLVA) 1-20 GHz Features Parameter Conditions Typ. Units Input Frequency Range 1-20 GHz

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

C-Band Redundant LNB Systems

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

HMC-C078. SDLVAs. Features. Typical Applications. General Description. Functional Diagram

Power Amplifier 0.5 W 2.4 GHz AM TR Features. Functional Schematic. Description. Pin Configuration 1. Ordering Information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Features. = +25 C, Vdd = +7V, Idd = 820 ma [1]

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Parameter Min. Typ. Max. Min. Typ. Max. Units

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Features. = +25 C, Vs = 5V, Vpd = 5V

Features. = +25 C, As a Function of LO Drive & Vdd. IF = 1 GHz LO = -4 dbm & Vdd = +4V

TGA GHz 30W GaN Power Amplifier

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Instruction Manual Model BlockUpconverter

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

The Hmc869LC5 is ideal for: Point-to-Point and Point-to-Multi-Point Radio. Parameter Min. Typ. Max. Units

= +25 C, IF= 100 MHz, LO = +15 dbm*

Features. = +25 C, IF = 0.5 GHz, LO = +15 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

Features. Parameter Min. Typ. Max. Min. Typ. Max. Units

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

= +25 C, IF= 100 MHz, LO = +15 dbm*

Ku-Band Redundant LNB Systems

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

Parameter Symbol Units MIN MAX. RF Input Power (CW) Pin dbm +20. LO Input Power (CW) Pin dbm +27

Requires half the number of feeder cables

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

= +25 C, IF= 100 MHz, LO = +17 dbm*

ALPAN W Compact DTV Transmitters 3-4U 19 HE DIGITAL ANALOG

Inmarsat Downconverter Narrowband Downconverter

RF V W-CDMA BAND 2 LINEAR PA MODULE

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Features. = +25 C, IF= 1 GHz, LO= +13 dbm* Parameter Min. Typ. Max. Units

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

Simplified Block Diagram

QPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

PAM-1840 Preamplifier Operation Manual

GaAs DOUBLE-BALANCED MIXER

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

MICROLITHIC DOUBLE-BALANCED I/Q MIXER

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

OBSOLETE HMC908LC5 MIXERS - I/Q MIXERS, IRMS & RECEIVERS - SMT. GaAs MMIC I/Q DOWNCONVERTER 9-12 GHz. Typical Applications. Functional Diagram

Features. = +25 C, IF= 1 GHz, LO= +13 dbm* Parameter Min. Typ. Max. Units

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Features. = +25 C, IF= 100 MHz, LO= +15 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

Wide Band Power Amplifier 6GHz~12GHz. Parameter Min. Typ. Max. Units Frequency Range 6 12 GHz Gain db Gain Flatness ±2.0 ±3.

Indoor Dual Converter

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

HMC576LC3B MULTIPLIERS - ACTIVE - SMT. SMT GaAs MMIC x2 ACTIVE FREQUENCY MULTIPLIER, GHz OUTPUT. Features. Typical Applications

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

SYNTHESIZED COMMUNICATION CONVERTERS

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

SPECIFICATION. Multistandard Demodulator tuner. ATSC/Legacy analog NTSC/BTSC

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

OPTICAL DISTRIBUTION STATION -

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

SPECIFICATION. DVB-T / Worldwide NIM Tuner

FMMX9004 DATA SHEET. Field Replaceable SMA IQ Mixer From 15 GHz to 23 GHz With an IF Range From DC to 3.5 GHz And LO Power of +17 dbm.

UNISONIC TECHNOLOGIES CO., LTD TL431L

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Parameter Min. Typ. Max. Min. Typ. Max. Units

Transcription:

Technical Specification Summary Frequency Range 470 862MHz Typ. Gain 56 db P1dB 1400 W Typ. Efficiency >40 % @ 1dBcp Analogue TV 2400 Wps Temperature Range 0 to +45C DVB 290 Wrms Max VSWR 3:1 DTV 500 Wrms Working Class AB Dual tone 1400 Wpep Supply Voltage 30 V Devices: MRF377 (Freescale Semic.) or equivalent Key Features and functions BroadBand (470-862 MHz) Internal cabling free Easy maintenance without special tools -RS485 interface Control software included Extremely strong mechanical structure General Description AU200-D is a full LD-MOS Broadcast Power Amplifier designed for both digital and analog applications. The unit is the state of the art in terms of easy assembly, reliability and performances. The complete unit can assure the compliance to all relevant international standards. Actual Power Amplifier Picture File: AU200-D.xls Page 1 of 7

Electrical Specifications Parameter Min. Typ. Max Units Notes Frequency 470 862 MHz Full coverage without tuning P1dB 1400 W In CW Mode Power 1200 1400 Wpep 2 tones, 100kHz spacing (-27dBc) IMD3-30 dbc 2 tones, 100kHz spacing (1000Wpep) Power Input 4 dbm Max value in CW mode @ 1dBcp Gain 56 db V Supply 30 Vdc By External Power Supply Drain Current 90 A Analof TV @ black field Input return loss -16-20 db Phase Variation +/-5 Unit to unit Gain Variation +/-0,5 [1] db F2 Second Harmonic -35 dbc F3 Third Harmonic -45 dbc Baseplate Temp. -10 +75 C Video Parameter Min. Typ. Max Units Notes Digital Power (DTV) 500 Wrms Digital Power (DVB-T) 250 280 W M.E.R. (DVB-T) 30 db Shoulders (DVB-T) -32 dbc At ± 4.2 MHz / 250 W rms Shoulders (DVB-T) -30 dbc At ± 4.2 MHz / 280 W rms [1] WARM UP: To achieve the stability vs temperature correct value when the equipment is cold, please wait 30 minutes at least after switching on. Physical Dimensions Weight ABSOLUTE Maximum Ratings Parameter Value Units Notes Output Power 1400 W in CW mode Input Power 5 dbm in CW mode Operating Voltage 32 Vdc Stable operations 30 Vdc Bias Current 10 A Quiescent current for four LDU400C pallets Drain Current 100 A VSWR 3:1 Storage Temp. -20 +80 C Base Plate temp. 75 ºC Heatsink Temperature Electrical Interfaces 482,6mm x 132,5m x 600mm / 19"x5,217"x23,622 " 25 kg. / 55 lbs All Specifications are valid for load impedance 50 Ohm, V=xxVdc, I=xxA RF input RF output RF Monitor RS485 N female on Rear Panel 7/16 DIN female on Rear Panel SMA connector on Rear Panel Dsub 9 Pin on front and rear panel Dsub 9 Pin on rear panel File: AU200-D.xls Page 2 of 7

Mechanical specifications AU200-D Physical Dimensions 19 Inch x 3 Units x 600mm (23,62") depth Weight 25 kg. / 55 lbs RESET MAINS VDC GAIN ADJUSTMENT ENABLE SWITCH EXT ENABLE DERATING FAULT File: AU200-D.xls Page 3 of 7

RF MONITOR EXTERNAL SENSES RF INPUT Block Diagram - VDC POLES + VDC RF OUTPUT EXTERNAL ENABLE RS485 GROUND IMPEDANCE SELECTOR +5V PS EXTERNAL ENABLE RS485 Logic Unit 4 X LDU400C RF Input RF Control LDU05M LDU60 4way Splitter 4way Combiner RF Output P.DRV DRV Directional Coupler Service Regulator 30V Power Supply FANS 5V Service Supply File: AU200-D.xls Page 4 of 7

READABLE DATA BY REMOTE COMPUTER OR CONTROL LOGIC UNIT (via / RS485) ALARMS/STATUS Enable RF Faults Temp Max C Pin max VSWR max NOTES ON / STAND BY ACTIVE if Gain < 6dB referred to nominal ACTIVE when RF Thermal Protection is ON ACTIVE when RF Overdrive Protection is ON ACTIVE if VSWR max Protection is ON MEASUREMENTS RF Power Input Input level expressed in [micro Watt] RF Power Output Output level expressed in [Watt] RF Power Driver Driver level expressed in [Watt] RF Temperature RF Heatsink Temperature expressed in C (half section) RF Temperature 2 RF Heatsink Temperature expressed in C (half section) VDC Main Power Supply / Input Voltage IDC Final 1 Supply Current of half section (two LDUxxx) expressed in Ampere IDC Final 2 Supply Current of half section (two LDUxxx) expressed in Ampere IDC Driver Supply Current of Predriver and Driver expressed in Ampere Self Protection Thermal Protection High Temperture protection Overdrive Pin max must be set on the working channel with the used DVB-T signal High Output Mismatch VSWR max must be set on the working channel with the used DVB-T signal External High Power Supply Technical Specifications Output Power Characteristics 3 Vout Iout Max operative current Current Limit Load Regulation Output Ripple Sense Enable 30Vdc 2 x 50A or 1 x 100A in analog application 3 x 30A or 1 x 60A in digital application 2 x 55A or 1 x 110A in analog application 3 x 35A or 1 x 70A in digital application +/- 0,5% from 10% up to 100% dinamic load change 400mV max External Sense for both sections (if double). Sense Impedance 6,8KΩ each positive/gnd wire. AU200-D provides a signal 0/5V (0 = disable; 5 = enable). Open collector with internal pull-up. This signal must be used to enable the power supply. External Service Power Supply Technical Specifications Output Power Characteristics 4 Vout 5Vdc Iout 0,5A Load Regulation +/- 0,5% from 10% up to 100% dinamic load change Output Ripple 50mV max Enable This tension must be always enabled and connected 3 Only Power Supply output characteristics are indicated. Input characteristics must be in accordance with available networks. A high input isolation, well protected from possible spikes at input, is suggested. File: AU200-D.xls Page 5 of 7

4 Only Power Supply output characteristics are indicated. Input characteristics must be in accordance with available networks. A high input isolation, well protected from possible spikes at input, is suggested. Graphs and Charts -40 In channel IMD vs Frequency Four-tone test -5, -16, -13, -20 db ref. 1000W -45 IMD (db) -50-55 -60 400 450 500 550 600 650 700 750 800 850 900 Frequency (M Hz) Without precorrection -20 SHOULDER vs FREQUENCY 200W rm s DVB-T -25 dbc -30-35 -40 400 450 500 550 600 650 700 750 800 850 900 Fre que ncy (M Hz) Without precorrection Note: By the use of UBS DVB-T Modulator Mod. PT8750 + PT8731 option, and the proper precorrection, the AU200-D is able to deliver 280Wrms at better than 36dBc shoulders on all the band. File: AU200-D.xls Page 6 of 7

precorrection, the AU200-D is able to deliver 280Wrms at better than 36dBc shoulders on all the band. Ordering informations Manufacturer's Part n. Feature Description AU200-D Standard version IMPORTANT NOTICE RES-INGENIUM RESERVE THE RIGHT TO MAKE CHANGES TO THE PRODUCT(S) OR INFORMATION CONTAINED HEREIN WITHOUT NOTICE. RES-INGENIUM ASSUMES NO RESPONSIBILITY FOR ANY ERRORS WHICH MAY APPEAR IN THIS DOCUMENT. WARRANTY INFORMATION APPLICABLE TO THE PRODUCT IDENTIFIED HEREIN IS AVAILABLE UPON REQUEST. NOTHING CONTAINED HEREIN SHALL CONSTITUTE A WARRANTY, REPRESENTATION OR GUARANTEE OF ANY KIND. RES-INGENIUM EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND/OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, AND OF FITNESS FOR A PARTICULAR PURPOSE, USE OR APPLICATION. NO PART OF THIS DOCUMENT MAY BE COPIED OR REPRODUCED IN ANY MEANS WITHOUT THE PRIOR WRITTEN CONSENT OF RES-INGENIUM. WARNING THE SPECIFICATIONS CONTAINED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE. RES-INGENIUM S.r.l. ASSUMES NO LIABILTY FOR THE USE OF THIS INFORMATION. THIS DATA SHEET AND CONTENTS ARE THE PROPERTY OF RES-INGENIUM S.r.l.. RES-INGENIUM PRODUCTS ARE NOT INTENDED FOR USE IN LIFE SUPPORT APPLIANCES, DEVICES OR SYSTEMS. USE OF A RES-INGENIUM PRODUCT IN ANY SUCH APPLICATION WITHOUT WRITTEN CONSENT IS PROHIBITED. File: AU200-D.xls Page 7 of 7