EVC300i. Generator Automatic Voltage Regulator Operation Manual

Similar documents
EVC600i. Generator Automatic Voltage Regulator Operation Manual

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual

EG4015. Digital Generator Governor Controller User Manual

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

ADVR-08. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

multi-function meters

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

263 Series LED Bargraph Indicator and Controllers

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

AF-300 E11 Adjustable Frequency Drive

Gamma instabus. Technical product information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Australian Technical Production Services

HS-509 VIBRATION TRIP MODULE

ADJUSTABLE SPEED DRIVES. nc1 Drive

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Form C: Type Test Verification Report

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Westrex RA1713B Auxiliary Record Electronics

Form C: Type Test Verification Report

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

1 Power Protection and Conditioning

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

Model /29S RF Splitter

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Rebis Audio Ltd. RA226 Digital Sampler User Guide

BE3-GPR GENERATOR PROTECTIVE RELAY

INSTRUCTION BOOK FOR. Special Needs Lecterns

High performance circuit breakers

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

Series CT7N Bimetallic Overload Relays

COHERENCE ONE PREAMPLIFIER

Telemetry Receiver Installation Guide

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

with Simulated Outputs Description Applications Features

MAP110 AC-DC Series Data Sheet

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

J R Sky, Inc. tel: fax:

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Electronic M.O.P Card. Instruction Manual Model D

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

LAUREL ELECTRONICS, INC.

50 Hz 60 Hz VOLTAGE Connections

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Indoor Linear 80W Driver SI-C215280N2KR

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

Instruction Manual Model # Block Upconverter

INSTRUCTION BOOK FOR. Lectern

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

Type MG-6 Auxiliary Relay Class 1E

SCALE & WEIGHT DISPLAYS

Certificate of Calibration

MILLITARY SPECIFICATION SHEET

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Global Water Instrumentation, Inc.

G.R.A.S. Sound & Vibration

LAMM INDUSTRIES, INC.

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Aspect 2 Circuit Digital Scene Control

JENCO ELECTRONICS, LTD.

TUSKIN Equipment Corporation

ABB i-bus EIB Universal dimmer 6155 EB for Installation

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Instruction Manual Model BlockUpconverter

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

TWO CHANNEL MICROPHONE PREAMPLIFER

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

Model Number Structure

MULTIS L72. Operating instructions

TOSHIBA Industrial Magnetron E3328

King Fahd University of Petroleum and Minerals Electrical Engineering Department 1. Homework 5 - SOLUTION KEY

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Output Board - v2* 4.1 Overview. 4.2 Audio Circuitry Program and Audition Outputs

21 Channel Light Show PWM LED Controller with Remote Control

1/3 RACK-MOUNTED BLOCK CONVERTERS

INSTRUCTION BOOK FOR. Lectern

MODEL PA II-R (1995-MSRP $549.00)

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

Transcription:

EVC300i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC300i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless generators. The AVR circuitry includes under speed and over load protection features. Excitation power is derived directly from the generator terminals. 2. ENVIRONMENTAL 2.1. Operating temperature: -30 to 80 C (-22 to 176 F) 2.2. Storage temperature: -40 to 80 C (-40 to 176 F) 2.3. ALTITUDE: Less than 2800 meter 2.4. RELATIVE HUMIDITY: <90% 3. TECHNOLOGY SPECIFICATION Sensing Input Terminal V - V Terminal V - V 220 380 Power Input Voltage: 180 to 250 Vac Frequency: 50 Hz or 60 Hz Voltage Adjust Range 180-300 Vac, 300-520 Vac Field Resistance Recommend 9-24 Ω Voltage Regulation < ± 1% for 220 Vac for 400 Vac Output Voltage Maximum 90 Vdc @ 240 Vac Output Current Maximum continuous: 6.3 A @ 240 Vac 10 second forcing: 10 A @ 240 Vac Paralleling Internal burden and adjustment for 0 to 10% droop at 1 A, 0.8 PF, (from external CT) Voltage Buildup 4Vac, 30 Hz External Volts Adjustment At least ± 10% with 100k ohm 1 watt trimmer Thermal Drift 0.05% per C change in AVR ambient Analog Voltage Input ±5VDC, adjustable output voltage is no less than 2% for 1VDC (i.e. for ±5VDC it come out to be ±10%) Current Compensation In : 1A Input Not Less than 10 % @ P.F. = 0.8 Dimensions 122 mm L x 93 mm W x 38 mm H Weight 300 ± 10g Page 1 of 7

4. MECHANICAL SPECIFICATION DRAWING 122 mm TRIM O/L POT O/L LED 2 X 4.4 mm A+ A- S W1: ON - Increase in Response Time. OFF - Response as per STAB pot Set SW 2: ON - 60 HZ OFF - 50 HZ 93 mm 1 2 ON 80 mm UFRO LED FUSE 6.3 Amps S2 S1 VR2 VR1 V380 V220 V N F+ F- 108 mm H 38 mm U U U S2 S1 VR2 VR1 V380 V220 V N F+ F- Figure 1. Outline Drawing 108 mm ENGGA 80 mm www.engga.com.cn EVC300i Sensing Input : V - V220 for 220Vac, 180 to 250Vac, 50/60 Hz V - V380 for 400Vac, 350 to 480Vac, 50/60 Hz 93 mm Power Input : 180 to 250Vac, 50/60Hz, 1 Output : 90 Vdc,6A VOLT STAB UFRO DROOP 122 mm Figure 2. The Drawing For Trimmer Page 2 of 7

AVR can be mounted directly on the generator, switchgear or control panel that conforms to the mounting specification. All voltage readings are to be taken with an average-reading voltmeter. Meggers and high-potential test equipment must not be used with AVR connected to generator. Use of such equipment could damage the AVR. 5. WIRING 1. V - V220 - V 380: Sensing Input Voltage. Sensing Input is between V & V220 (220Vac) or V & V380 (400VAC). For 2 Phase sensing one phase is connected to V terminal of AVR and second phase is connected to V220 or V380 as explained below:- - For generator output voltage 220Vac, connect sensing phase to terminal V220. - For generator output voltage 400Vac, connect sensing phase to terminal V380. The sensing should be connected Line to Line from generator output. Refer Figure 3 & 4. 2. F+. F- : Excitation Output. Connect the brushless exciter field to terminals F+ and F-. Be sure to observe polarity. 3. Power Input: AVR power input is between N & V. For 400 Vac system N is connected to Neutral of generator & V to V Phase of generator. For 220 Vac system, N is connected to U Phase & V to V Phase of generator. Refer to Figure 3 & 4. 4. S1 - S2: Current compensation input. Current Transformer(CT) secondary current = 1A, 0.8 PF. 5. VR1 - VR2: External Voltage Adjustment. If an external voltage adjust control is being used, connect a 100 K / 1 watt potentiometer to terminals VR1 and VR2 as shown in Figure 3 & 4. If not in use then let VR1 & VR2 is left open. 6. A+ & A-: Analog Voltage Input. Fully isolated analog voltage from PF controller or any other type of Digital (PLC) controller can be injected into AVR for variation of generator output voltage. Analog voltage range is ± 5VDC maximum and can be connected to A+ & A- terminals for at least 10 % variation in terminal voltage. 7. DIP SWITCH: a) SW1 - ON: When 60Hz operation, AVR response time needs to be reduced. For that turn ON Switch1 so that extra fixed response time is now added with STAB POT setting such that no over or under shoot of voltage occurs during loading-unloading of generator at 60Hz. SW1 - OFF : When 50Hz operation, no need to decrease response time as STAB POT setting is proper for optimum stability of generator with minimum over-under shoot of Voltage during loading - unloading of generator. b) SW2 - ON: For 60 Hz operation of UFRO SW2 - OFF: For 50 Hz operation of UFRO 6. ADJUSTMENT All trimmer build in back of the AVR board, except the O/L and TRIM Trimmer. The trimmers include DROOP, UFRO, STAB and VOLT as shown in Figure 2. For O/L Trimmer and TRIM Trimmer refer to Figure 1. 1. VOLT: Voltage Adjustment. The generator output can be altered by adjustment of the VOLT trimmer on the AVR board, or by the external trimmer (100K ohm 1W) if fitted. Vset is factory set for 400 Vac, If Vset is disturbed and set value is not known then proceed as below : a) The terminals VR1 and VR2 must be left unconnected if no hand trimmer is required. Page 3 of 7 b) Before starting the generator, please turn the VOLT trimmer on the AVR board fully anticlockwise. c) Connect a voltmeter to generator output voltage terminals. d) Start the generator set and run on no load at nominal frequency 50-53 Hz or 60-63 Hz. e) If the red Led is illuminated, refer to the under frequency roll off adjustment. f) Carefully turn volt trimmer clockwise until rated voltage is reached. 2. STAB: Stability Adjustment. Stability Pot is factory set for optimum performance & is advisable not to disturb. But if required then with the generator in ON Condition, rotate STAB POT clockwise direction till voltage start oscillating fast.

From this position, rotate STAB POT anticlockwise direction till voltage is stable. Load the generator and check for stable voltage and if not then rotate more towards anticlockwise till voltage is stable. 3. UFRO: Frequency Roll-Off Adjustment. The EVC300i under frequency adjust is factory preset to cause voltage drop in the generator line voltage when the frequency is between 56.8 and 57.2 Hz for 60 Hz applications. For 50 Hz applications, the frequency roll-off is factory preset to between 46.8 and 47.2 Hz. To reset the frequency roll-off, proceed as follows: a. Adjust the prime mover RPM to the desired frequency compensation (corner frequency roll-off) point. b. If UFRO LED is ON adjust the back panel UFRO trimmer anticlock wise to just OFF the LED If UFRO LED is OFF then adjust UFRO trimmer clockwise to turn ON LED and then anticlockwise to just turn it OFF. c. Bring the prime mover up to rated speed. The output voltage should return to set level. 4. DROOP: Droop Adjustment. Generator intended for parallel are fitted with a quadrature droop CT which provides a power factor dependent signal for the AVR. The CT connected to S1 and S2 of AVR. CT with secondary N:1A is required to provide minimum 10% droop at 0.8 PF. Percentage of droop required can be adjusted using DROOP POT in the range of 0 to 10%. Fully anticlockwise is 0% and fully clockwise is maximum as per CT current and load power factory. Factory set is 0% so that mostly during solo operation there is no droop in terminal voltage. value (which is set using O/L POT), internal timer starts and if overloading condition continues for 20 seconds then after 20 seconds AVR cuts off field voltage and generator voltage is shut off. O/L LED continues to light indicating O/L Trip. Adjustable from 0.1Amp to 7Amp DC. When O/L POT is fully anticlockwise is minimum setting and fully clockwise is maximum. Internal delay timer is fixed and delay time is 20 seconds ±1% OPERATIONAL TEST To operationally test any EVC300i, refer to Figure 5 and perform the following steps: a. Connect the voltage regulator as shown in Figure 5 and apply 230 Vac 50 Hz. b. Adjust the rear panel VOLT trimmer fully clockwise (CW). RESULT: Observe that the lamp lights up full. c. Adjust the rear panel VOLT trimmer fully counterclockwise (CCW). RESULT: Observe that the lamp is not lit. d. Adjust the rear panel VOLT trimmer until the lamp just goes out. Regulator operation is satisfactory if the above results are obtained. Stability, however must be tested with the generator and regulator operating. 5. TRIM: Analog Voltage Input Adjustment. Trim Pot is used to decrease the effect of analog input voltage on generator output voltage. When set fully anticlockwise, there is no variation in generator voltage on application of DC voltage on A+ & A- Fully clockwise has maximum effect. Thus using this POT we can get intermediate percentage variation of the full scale - 10% at ± 5VDC. 6. O/L : Over Load Protection. Over load protection provides protection to generator against overloading. It is based on field current when field current increase above set Page 4 of 7

Exciter Field - + Armature Stator Wire CT IN : 1A U V W N 100K/1W Note : All doted lines are optional connections. F- F+ N V V220 V380 VR1 VR2 S1 S2 FUSE 6.3 Amps UFRO LED ON 2 1 SW.2: ON - 60 HZ OFF -50 HZ A- A+ SW1: ON - Increase in Response Time. OFF - Response as per STAB pot Set O/L LED O/L POT - TRIM + 5 Vdc Analogue Input Figure 3. Connection Diagram for 400 Vac Operation Page 5 of 7

Exciter Field - + Armature Stator Wire CT IN : 1A U V W 100K/1W Note : All doted lines are optional connections. F- F+ N V V220 V380 VR1 VR2 S1 S2 FUSE 6.3 Amps UFRO LED ON 2 1 SW.2: ON - 60 HZ OFF -50 HZ A- A+ SW1: ON - Increase in Response Time. OFF - Response as per STAB pot Set O/L LED O/L POT TRIM +/- 5 Vdc Analogue Input Figure 4. Connection Diagram for 200 Vac Operation Page 6 of 7

230Vac/50Hz LAMP 220V100W F- F+ N V V220 V380 VR1 VR2 S1 S2 FUSE 6.3 Amps UFRO LED ON 2 1 SW.2: ON - 60 HZ OFF -50 HZ SW1: ON - Increase in Response Time. OFF - Response as per STAB pot Set A- A+ TRIM O/L POT O/L LED Figure 5. Operational Test Page 7 of 7

ENGGA ( YANGJIANG ) ELECTRIC CO., LTD. No. 1,CHASHAN 325 NATIONAL HIGHWAY, BAISHA STREET, JIANGCHENG DISTRICT, YANGJIANG CITY, GUANGDONG PROVINCE, CHINA - 529500, TEL : +86 20 66600889 EMAIL : service@engga.com.cn I WEBSITE : www.engga.com.cn