Film Capacitors Power Factor Correction

Similar documents
Film Capacitors Power Factor Correction

Power over Ethernet Transformers 60 W series

Film Capacitors Power Factor Correction

Film Capacitors AC Capacitors Application note

SAW components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Base stations LTE band 27. Date: October 31, 2016 Version: 2.

Film Capacitors Power Factor Correction

3 line filters for converters and power electronics

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions

KRF EMC Filters Installation, Operation and Maintenance Manual

Filters for Power Lines (Low Leakage Current)

R&S RT-Zxx High-Voltage and Current Probes Specifications

Operating Instructions

Clamp 200 A AC/DC (+ V AC/DC + Ω)

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Linear / area fixed output

User Manual Power and Harmonics Analyzer Model PQ3350

R&S RT-Zxx High-Bandwidth Probes Specifications

MIKRO POWER FACTOR CORRECTION COMPONENTS

POWER FACTOR CORRECTION

QPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

LED Driver Compact dimming

MS2540 Current Loop Receiver with RS485 Communication

AC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

LED Driver Compact fixed output

Dynatel Advanced Cable Locator 2250

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

MULTIS L72. Operating instructions

TRF STEP-DOWN TRANSFORMER USER MANUAL

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

Modular pulse operated latching relay 16 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LED Driver Compact fixed output

8 Installation Equipment

LED Driver Compact fixed output

RF1119ATR7. SP4T (Single Pole Four Throw Switch) Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Tube Rotator. User Guide. Version 1.2

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Power Quality Solutions

Video Accessory IC Series Sync Separation ICs with Built-in AFC BA7046F, BA7071F Rev.A 1/9

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

LED control gear Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

LED Driver Compact dimming

LED Driver Compact dimming

Gamma instabus. Technical product information

KHT 1000C HV-Probe Calibrator. Instruction Manual

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

LED Driver Compact dimming

Panel-Mounted Thermostat

Certificate of Calibration

Panel-mounting thermostats, type series EM

R&S RT-Zxx Standard Probes Specifications

R&S ZN-Z85 Switch Matrix Specifications

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Standard RS232 RS ma

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Nessie Coils for VDH and VDHT valves

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Capacitors and banks 50 Hz 0 400/415 V network voltage

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

OPTOTRONIC Intelligent

Tube Roller Shakers. User Guide. Version 1.2

Instructions. P MHz 1X/10X Passive Probe

True RMS AC/DC Mini Clamp Meter

Advanced Digital Melting Point Apparatus

Datasheet - SRB301LC 24VAC/DC

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Programmable Power Supplies 188 W 384 W R&S HMP Series

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

-Technical Specifications-

Function Manual SIMATIC HMI TP900. Operator Panel.

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

LED Driver Compact dimming

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

Transcription:

Series/Type: Ordering code: Date: August 2010 Version: 2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 Film Capacitors Power Factor Correction (header 1 + top left bar): Identification/Classification 2 (header 2 + bottom left header bar): Ordering code: (top right header bar) Series/Type: (bottom right header bar) Preliminary data (optional): Department: Date: August 2010 Version: 2 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Characteristics Three-phase measuring, display and storage of numerous electric parameters in LV-grid: Voltage (3-phase) Current (3-phase) Frequency (3-phase) Active power (3-phase) Reactive power (3-phase) Apparent power (3-phase) Power factor (3-phase) Active, reactive and apparent energy Voltage harmonics (up to 51 st ) Current harmonics (up to 51 st ) THD-V (3-phase) THD-I (3-phase) Temperature Minimum and maximum values with time stamp Display and internal storage of maximum values with time stamp Display of date and time Display of harmonics, bar diagram available Large number of display options e.g. rotating display and adjustment of font size Oscilloscope mode for graphical display of a complete oscillation incl. the harmonics Display of measured values (display editor) and rotating change of selected display values freely programmable Storage of all measured grid parameters on pluggable memory card (SD card), included in delivery Adjustment of font size to large display (max. 3 measuring values in the display) Plain-text menu in English, German, Russian, Spanish and Turkish Display and internal storage of maximum values with time stamp Please read Cautions and warnings and Page 2 of 8

PC-Windows software for fast and easy evaluation of measured data included in delivery Administration of several projects Graphical display Several pre-configured graphical displays of standard values Graphical display of selected grid values, large number of configuration options Convenient editing of parameters and time interval Display as line graph or bar diagram Copy into clipboard and print function available Mathematical evaluation of measured values Automatic calculation of required kvar (target-cos to be set by user) Evaluation of measured harmonics and recommendation of detuning factor for a PFC system of calculated size Influence of detuning on the harmonics for the calculated detuning factor and system size is given. PC-Windows software for fast and easy evaluation of measured data included in delivery Please read Cautions and warnings and Page 3 of 8

Technical data and specifications Operating voltage (auxiliary voltage) Power consumption Internal pre-fuse Frequency Measuring voltage (3-phase) Max. Measuring voltage (3- phase) including all tolerances and overvoltages Measuring current (3-phase) Display Menu Display of grid parameters as real value / in % / as bar diagram Display of 3 grid parameters in large font 110 230 V AC +/-15% 50/60 Hz < 5 VA 1 AT 50/60 Hz 3 30 400 V ~ (L-N) 50/60 Hz 3 50 690 V ~ (L-L) 50/60 Hz 3 30 440 V ~ (L-N) 50/60 Hz 3 50 760 V ~ (L-L) 50/60 Hz 30 / 300 / 3000 A (MiniFlex flexible current clamps, to be ordered separately) Illuminated, full graphic, 128 x 64 dot D/ E / ES / RU / TR 3-phase Cos-phi, V, I, f, Q, P, S, THD-V, THD-I Selection in display editor Display of harmonics 3 rd to 51 st harmonics of voltage and current, also as bar diagram Oscilloscope mode Available Sensitivity Current/voltage: 1% Active, reactive and apparent power: 2% Integrated help function with HELP Context dependent, plain text button Recording, storage function Storage of all grid parameters on SD card according to pre-set measuring interval Data carrier Measuring interval Duration of recording per file at intervals of 1/10/60 seconds Additional storage of maximum values in the internal store of the measuring device Error storage 3-phase Cos-phi, V, I, f, Q, P, S, THD-V, THD-I Standard SD card included in delivery 1 / 10 / 60 seconds 18 hours / 7 days / 45 days Voltage, current, active, reactive and apparent power, temperature, THD-V, THD-I Error register in plain text with time stamp Influence of detuning on the harmonics for the calculated detuning factor and system size is given. Please read Cautions and warnings and Page 4 of 8

Additional specifications Ambient temperature range (operation) -10 +50 C Storage temperature range -20 +60 C Pollution degree 2 Overvoltage class Protection degree to IEC60529 Connection CAT III IP40 N connection mandatory, PE if N not available Security IEC 61010-1:2001; EN 61010-1:2001 EMV Casing Weight Accessories included Accessories mandatory, but not included in the delivery IEC 61000-4-2: 8kV; IEC 61000-4-4: 4kV Compact lightweight plastic case 390 x 310 x 147 mm (outside dimensions) Approx. 4 kg 3 safety measuring cables 2 m (black, red, violet), 1000 V, CAT IV, incl. high-power fuse 1 safety measuring line 2 m, blue, 1000 V, CATIII 4 safety dolphin clips 1000 V, CATIII, black, red, violet, blue Windows software CD 1 memory card (SD-Card); 1GB 1 power lead 3 flexible MiniFlex current clamps, cable 2.8 m, 600 Vrms (CAT IV), 1000 Vrms (CAT III) max. 3000 A, sensor 400 mm Ordering code 1 piece: B44066M1301E230 Ordering code 3 pieces: B44066M1303E230 Display of ordering codes for EPCOS products The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes Influence of detuning on the harmonics for the calculated detuning factor and system size is given. Please read Cautions and warnings and Page 5 of 8

Cautions and warnings The is designed exclusively for use in low-voltage switching systems. It is unsuitable for measurements in mid and high-voltage networks. The maximum permissible supply voltages (see technical data) must not be exceeded! The equipment may be operated only by suitably trained personnel. Before applying the measuring voltage, the device must be grounded via the power connection line (protective conductor socket). An additional PE socket is available. Measurements with ungrounded equipment constitute a hazard and are impermissible! When measuring systems whose zero-potential status is not ensured, the accident prevention specifications must be observed! For voltage measurements, only measuring lines with an isolation class of at least CATIII/1000 V may be used. Note For detailed information about PFC capacitors and cautions, refer to the latest version of the EPCOS PFC Product Profile. Influence of detuning on the harmonics for the calculated detuning factor and system size is given. Please read Cautions and warnings and Page 6 of 8

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements ( CSR ) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. Page 7 of 8

Important notes 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Release 2018-06 Page 8 of 8