about dktcomega DKTCOMEGA s mission

Similar documents
OPTICAL FIBERCONNECT. Version 3.

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

LTX Optical Distribution Panels. Ordering Guide

SECTION 4 TABLE OF CONTENTS

Singlemode Patch Cords and Pigtails

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

SC Connector. Fiber Optic Connectors. MDR Electronics

P-AD ADAPTORS. Features: Low insertion loss Low back reflection loss Easy to handle Environmentally stable

Optical Component Environmental Test System

DWDM. DATA SHEET DB4134-E Issue F Page 1 of 6

coaxial passives & accesories

Connectivity accessories by Nestor Cables

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

distribution passives basic series

OPTICAL POWER METER WITH SMART DETECTOR HEAD

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Enterprise Networks. Comms Room and Backbone. in DETAIL

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

FIBER OPTIC POSITRONIC INDUSTRIES. Interconnection Systems. RoHS Compliant Options Available! Catalog A-011 Rev.

EDFA Erbium Doped Fibre Amplifier

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product

POLARIZED FIBER OPTIC SOURCE

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

Radio Frequency over Glass. Passive Optical Network (PON) for EuroDOCSIS infrastructures

RF OVERLAY V2. fttx rf/video overlay

Optical Channel Analyzer

HI-DEX PRODUCT SET DATASHEET

Fibre Optic Cable & Connector Guide

MTP1000 with LaserBlade, VOABlade, PowerBlade & SwitchBlade Smarter Modular Test Platform

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

PONA 3000 Series Erbium Doped Fiber Amplifier

MPS Webinar Technical Series

ED5229GT-E Series. Page 1 of 8

PONA 3000 Series Erbium Doped Fiber Amplifier

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

COE Group plc. Contents

OpticalProducts. Illuminating Your Network. Testing the World s Networks

MAP Optical Power Meter Module (mopm-b1)

The Art of Engineering

FiberConnectorSeries LC

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Follow The Leader In Shielded Technology

Light Source. Specification & User Manual

LIIN-25 FO Pigtail FC (0.9mm)

Optimax Field Installable Connectors and Installation Tool Kits

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Preferred ordering guide for NETCONNECT

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

OPTILAB CATALOG TRANSMITTER OPTICAL NODE MINI-NODE EDFA PASSIVE OPTICS RECEIVER

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity

Options: - Master Patchcord - Launch cable - Set of optical adapters

Structured Cabling. Product Line Brochure

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

! "#$ ' % & % & ' ( )!' *!+, ( *-"(! './ 0 / 0/ $ 1/ 2$3 1

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

LIST. Digital Video Transmitter and Receiver 11

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

for FOSTEC INC. 1/ 15

Connectix Cabling Systems

MXAN-LN series 1550 nm band Analog Intensity Modulators

Optical Passives Optical Mux/Demuxes, Optical Splitters, Optical Switch, Optical Shelves, Sidecar Enclosures

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

MTS/T-BERD 8000 Platform

3A+G Technology & Turnkey Production Solution XFS COMMUNICATIONS, INC.

6 3 0 N M, S I N G L E M O D E F U S E D F I B E R O P T I C C OUPLERS / TA P S

nm DFB Laser Module

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Introducing Ultra Short LC : Fiber Optic Cable Assemblies

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

MAFA 5000 Series Erbium Doped Fiber Preamplifier

Lensed Fibers & Tapered Ends Description:

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

MXAN-LN series 1550 nm band Analog Intensity Modulators

ED5229GT-E/GTRE Series

PM Couplers (Polarization Maintaining Couplers)

HDBS-5000DW Series. 950MHz~2400 MHz

IF and L-Band Fiber Optic Links. Performance Highlights

OZ Optics Limited. Polarization Maintaining Components. June 2018

MTS/T-BERD Platforms WDMPMD Module

Alternative Fiber Coupler Options

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

PRODUCT OVERVIEW OPTICAL NODES

Dual & Single Fiber DWDM Mux Demux

Compact Module. Category 6 FTP Cabling System

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

MPX and MPZ series Low frequencies to 40 GHz Phase Modulators

Keyed LC Connector Solution A LANscape Solutions Product

Benchtop/Rackmount Programmable Switches. Key Features & Benefits. SB/SC/SCG Series. Applications INSTRUMENTATION CATALOGUE - 73

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

MPX / MPZ series. Low frequencies to 32 GHz Phase Modulators. Modulator. Features. Applications. MPX-LN series Performance Highlights

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

Transcription:

optical passives

about dktcomega DKTCOMEGA designs optical and coaxial products for professional broadband operators and service providers. DKTCOMEGA s unique fibre optical product line, combined with the company s extensive FTTx experience, makes it a strong partner for FTTx operators and service providers. The company was founded in 1977. Its headquarters are in Denmark and it has subsidiaries in Sweden and Finland. It has always been DKTCOMEGA s philosophy to challenge the status quo and look for improvements to benefit the customer. In the late nineties DKTCOMEGA was therefore among the first to enter into the FTTx market and soon launched its own line of products in this field. By being an early mover in fibre optics DKTCOMEGA has gained in-depth technical knowledge and market respect, especially in the rapidly growing FTTH market. DKTCOMEGA s mission DKTCOMEGA s mission is to be a strong partner in network products for European broadband operators and solution providers. Based on know-how and natural enthusiasm, good ideas are developed into successful products. This is done together with the customer, who furthermore can appreciate the broad product range, the attractive quality/price level and the unique customised products. DKTCOMEGA s flexibility and proactive attitude assists in optimizing broadband networks. For requests, please contact: sales@dktcomega.com. Product introduction... 3 Pigtail and patch cables... 5 Single Mode Dual Window Couplers (1x2)... 9 Single Mode Tree Couplers (1x3 to 1x64 way)... 11 Wavelength Division Multiplexers... 13 Coarse Wavelength Division Multiplexers... 15 Attenuators... 17 Adaptors...19 Cable network panels...21 Coupling panels... 23 Specifications are subject to change without notice. DKTCOMEGA is not liable for any misprints or errors.

product introduction Introduction DKTCOMEGA offers a comprehensive line of optical passives for data, telecommunication and CATV applications. This extensive product line, including patch cables, pigtails, couplers, WDM and CWDM, has been designed for both digital and analogue transmissions and suit any passive optical installation. All products have been carefully selected together with international partners to comply with the highest industry standards and provide superior network performance. Overview The group consists of three different product series. The first series offers optical pigtails and patch cables. The product series provides various lengths and connecter types (Seikoh Giken or DKTCOMEGA) and provide low insertion loss and reflection. The second series, optical couplers, offers 1x2 through to 1x64 way splitters. This series of optical couplers is based upon the latest PLC technology and provides excellent optical features, including low insertion loss and excellent uniformity. Finally, WDM and CWDM. These consist of optical modules for network optimization. Whether the decision is to divide or combine the signal in the optical network, these modules provide excellent solutions. With a wavelength range from 1260-1360 nm and 1430-1600 nm and a broad selection of connector types, all DKTCOMEGA optical passives have been designed to fit into modern telecommunication, CATV and FTTx networks. 3

Advantages - Very high quality with excellent performance - Typ. <0.1 db insertion loss per connector - Test certificate available on each connector - High reliability - Increases network uptime

pigtails and patchcables Product information DKTCOMEGA s extensive range of optical patch cables has been selected to suit any passive optical installation. DKTCOMEGA offers a comprehensive range of patch cables and pigtails in various lengths and connector types for both data and CATV applications. The new range of patch cables offers unique ultra low insertion loss and back reflection, securing a limited loss budget for the transmission system, resulting in an extended network reach, better signal quality and reduces amplifier costs. Quality and test Each connector is thoroughly tested and reported with an interferometric microscope. Additionally, each connector is tested with focus on Insertion Loss and Return Loss. Serial number, IL and RL are written on the labels at each connector end as a standard. This ensures a unique quality with excellent performance, resulting in an optimal connection and high network uptime. Example of inspection sheet Inspection Data Ferrule Endface Geometry Optical Characteristic ROC (APC) Fiber height Apex Offset Actual Angle Key Error Insertion Loss (1310nm) Back Reflection (1310nm) Insertion Loss (1550nm) Back Reflection (1550nm) Result 5-12 mm ±100nm <50µm 8± 0.3º ± 0.5º <0.2dB >63dB <0.2dB >65dB Pass/Fail 7.05 27.1 32.23 7.756-0.095 0.08 68.7 0.09 69.9 Pass 7.04 26.9 36.36 7.761-0.175 0.07 67.4 0.11 68.2 Pass 5

pigtails and patch cables Optical connectors DKTCOMEGA provides a variety of optical connectors. The DKTCOMEGA connectors are known for its locking mechanism that gives an audible click when pushed into the adapter. This push-pull design prevents rotation misalignment. The connector family includes the Physical Contact (PC) pre-dome polished ferrule endface that reduces back reflection over a ferrule with a flat endface. To further reduce the unwanted back reflection DKTCOMEGA offers the Angled Physical Contact (APC) version that has a ferrule endface with an 8 angle. The DKTCOMEGA connector is available in a singlemode version with zirconia ceramic ferrules, and is fully compatible with NNT-SC hardware. The precision molded body and boot are made from ULrated material. All connector types are also available from Seikoh Giken upon request. Specifications - for DKTCOMEGA connectors Connector SC type LC type FC type E2000 type LX5 type Polish APC and PC APC and PC APC APC APC Insertion loss Max. (IL) Insertion loss Typical (IL) 0.2dB 0.2dB 0.2dB 0.3dB 0.5dB <0.1dB <0.1dB <0.1dB <0.1dB <0.15dB Return loss (RL) PC 55dB, APC 65dB PC 55dB, APC 65dB APC 65dB APC 65dB APC 60dB Operating temp. -40 + 75 C -40 + 75 C -40 + 75 C -40 + 75 C -40 + 75 C Ferrule material Zirconia Zirconia Zirconia Zirconia Zirconia Connector material Plastic Plastic Metal Plastic Plastic Tested according to: Telcordia, ANSI, IEC, TIA/EIA, NTT, JIS Telcordia GR-326- CORE, IEC 61754-20, ANSI Telcordia, ANSI, IEC, TIA/EIA, NTT, JIS Telcordia, ANSI, IEC, Telcordia, ANSI, IEC, Fiber type Buffer SMF-28e SMF 9/125μm 2800μm, Yellow Optional 900μm SMF-28e SMF 9/125μm 2800μm, Yellow Optional 900μm SMF-28e SMF 9/125μm 2800μm, Yellow Optional 900μm SMF-28e SMF 9/125μm 2800μm, Yellow Optional 900μm Standard G.652D G.652D G.652D G.652D G.652D SMF-28e SMF 9/125μm 3000μm, Yellow Optional 900μm

pigtails and patch cables Product overview Below is an overview of DKTCOMEGA s product range of optical pigtails and patch cables including, which connector type is available for the different cables. DKTCOMEGA Patchcables Type Standard lenght Wavelenght Connector type P-SC/APC-X-DKT 0.5, 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-LC/APC-X-DKT 2,5 meters 1285nm - 1625nm DKT or Seikoh Giken P-E2000/APC-X-DKT 0.5, 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT P-LX5/APC-X-DKT 0.5, 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT P-FC/APC-X-DKT 0.5, 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-SC/PC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-LC/PC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-LX5/PC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT DKTCOMEGA Hybrid Patchcables Type Standard lenght Wavelenght Connector type P-SC/APC-LC/APC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-SC/APC-E2/APC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT P-SC/APC-FC/APC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-SC/APC-SC/PC-X-DKT 2, 5 meters 1285nm - 1625nm DKT or Seikoh Giken P-E2/APC-LC/APC-X-DKT 2, 5 meters 1285nm - 1625nm DKT P-SC/PC-FC/PC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken P-SC/PC-LC/PC-X-DKT 1, 2, 3, 4, 5, 7, 10, 15, 20 meters 1285nm - 1625nm DKT or Seikoh Giken DKTCOMEGA Pigtails Type Standard lenght Wavelenght Connector type PT-SC/APC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken PT-LC/APC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken PT-FC/APC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken PT-LX5/APC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT PT-SC/PC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken PT-LC/PC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken PT-LX5/PC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT PT-FC/PC-X-DKT 1,5 and 3 meters 1285nm - 1625nm DKT or Seikoh Giken 7

Advantages - A complete range from 5/95-50/50 - High stability - Low insertion loss - High quality connectors - High network uptime

single mode dual window couplers ( 1 x 2 ) Product information In network design, optical couplers are often used, either for tap-off, or to divide/combine optical signals. For this purpose DKTCOMEGA can offer a range of 1x2 couplers with a splitting ratio ranging from 5/95 to 50/50 using on fused technology. The product group features low insertion loss and is specially designed for broadband networks as well as longhaul transmission systems. SC and LC are available as standard connectors. Other connectors can be ordered upon request (see page 6). Parameters Unit Data Excess Loss (Typ.) db 0.10 Maximum Insertion Loss db 3.6 Uniformity db Max. 0.6 Polarization Sensitivity db 0.2 Operating Wavelength nm 1260...1360 + 1430...1600 Return loss / Directivity db 55 Operating Temperature / Storage Temperature C -40 to 85 Fiber type Port Configuration G.652.D 9/125/2800 μm or 9/125/2000 μm or 9/125/900 μm 1x2 Housing dimensions mm 98 x 14 x 8.5 or 100 x 80 x 9 Type no Coupler ration Insertion Loss - (Max) Insertion Loss - (Typ.) OSP-S-5050-N 50/50 3.4 db 3.1 db OSP-S-5545-N 45/55 3.8 db/2.8 db 3.6 db/2.7 db OSP-S-6040-N 40/60 4.5 db/2.5 db 4.3 db/2.3 db OSP-S-6535-N 35/65 4.8 db/2.1 db 4.7 db/2.0 db OSP-S-7030-N 30/70 5.8 db/1.8 db 5.5 db/1.6 db OSP-S-7525-N 25/75 6.3 db/1.5 db 6.1 db/1.4 db OSP-S-8020-N 20/80 7.6 db/1.2 db 7.5 db/1.0 db OSP-S-8515-N 15/85 8.5 db/1.0 db 8.4 db/0.8 db OSP-S-9010-N 10/90 10.8 db/0.6 db 10.6 db/0.5 db OSP-S-9505-N 5/95 13.7 db/0.4 db 13.5 db/0.3 db Note: All specifications referenced without connector. 9

Advantages - High stability - Low insertion loss - High quality connectors - High network uptime - Option for 19 1HU

single mode tree couplers ( 1x3 to 1x64 way ) Product information In network applications, tree-couplers are very often used to either divide or combine signals from different locations in the optical network. For these applications DKTCOMEGA has a wide range of couplers to split and combine signals from 1x3 lines and up to 1x64 lines. The product group features low insertion loss, low excess loss, high directivity and is specially designed for longhaul telecommunications, CATV systems, and LAN networks. SC/APC is used as standard. Other connector types on request (see page 6). Parameters Unit Couplers Uniformity db 0.10 to 1.2(1x4), 1.8(1x8), 2.4(1x16), 3.0(1x32) Polarization Sensitivity db 0.10 to 0.4(1x4), 0.6(1x8), 0.8(1x16), 1.0(1x32) Operating Wavelength nm 1260...1360 + 1430...1600 Return loss + Directivity db 55 Operating Temperature / Storage Temperature C -40 to 85 Fiber type Housing dimensions mm G.652.D 9/125/2800um to 9/125/2800um, 9/125/2000um or 9/125/900um. 80x60x12(1x3 to 1x6), 80x120x12(1x7 to 1x32) to 98x14x8.5 or 100x80x9(1x3 to 1x6) or 116x80x102(1x3 to 1x15), 145x95.5x142(1x16 to 1x32) Type Coupler Insertion Loss - (Max) Insertion Loss - (Typ.) OSP-S-03-28-N 1x3 5.8 db 4.9 db OSP-S-04-N 1x4 7.2 db 6.2 db OSP-S-05-N 1x5 8.2 db 7.2 db OSP-S-06-N 1x6 9.5 db 8.0 db OSP-S-07-N 1x7 10.3 db 8.7 db OSP-S-08-N 1x8 10.8 db 9.3 db OSP-S-14-N 1x14 13.6 db 11.8 db OSP-S-16-N 1x16 14.0 db 12.4 db OSP-S-32-N 1x32 17.5 db 15.6 db OSP-S-64-N 1x64 21,3 db 19.3 db Note: All specifications referenced without connector 19 rack cabinets All tree-couplers can be supplied in 19 1HU rack cabinets for rack mounting. 11

Advantages - Low Insertion loss - High Isolation - Compact Size - Optical path epoxy free - Teleordia 1209, 1221 compliant

wavelength division multiplexers Product information Our single mode, standard type wavelength division multiplexers divide and combine 1310 / 1550 nm wavelengths. The 1310 / 1550 nm WDM coupler is the basic component to make up dual window WDM vdevices. The WDM components feature low insertion loss, low excess loss, high directivity and is specially designed for long-haul telecommunications, CATV systems, and LAN networks. SC/APC is used as standard. Other connector types on request (see page 6). Characteristics DKT WDM-30-XX DKT WDM-45-XX Insertion loss - Typ. db 0.7 1.0 Isolation db >30 >45 Polarization Sensitivity db 0.15 0.15 Operating Wavelength nm 1310 ± 20, 1550 ± 20 Directivity db >60 Return loss db >50 Operating Temperature / Storage Temperature C -40 to 85 Fiber types G.652.D 9/125/900 μm or 9/125/2800 μm Fiber Pigtail Length 1m or custom on request Package Dimension mm 100 x 80 x 9 mm Note: All specifications referenced without connector 13

Advantages - Low Insertion Loss and High Isolation - Good Wavelength Stability - Optical path epoxy-free with good environment stability - Bell-core 1221 compliant

coarse wavelength division multiplexers Product information The multiplexer module combines several wavelengths (channels) traveling in each separate single mode fibre into one single mode fibre, and the same module separates each specific wavelengths traveling in the common single mode fibre into wavelength, each traveling in a separate singlemode fibres. The CWDM Modules are based on thin-film filter technology. This proven technology offers wide channel bandwidth, flexible channel configuration, low insertion loss and high isolation. The CWDM modules are especially designed for WDM systems, metro networks, and CATV Systems. SC/APC is used as standard. Other connector types on request (see page 6). Data DKT CWDM 2 DKT CWDM 4+1 DKT CWDM 8+1 Channel Number ---- 3 (1310 + 2 x optional) 5 (1310 + 4 x optional) 9 (1310 + 8 x optional) Center Wavelength nm 1310-1610 Channel Spacing nm 20 Channel Pass Band (-0.5dB Bandwidth) Min. nm ±6.5 Insertion Loss Typ. db 0.6 1.0 1.8 Max. db 0.8 1.2 2.1 Link Loss With Mux & Demux Combination Max. db 1.2 2.0 3.6 Pass Band Flatness Max. db 0.3 Channel Uniformity Max. db 0.5 Isolation Adjacent Channels Min. db 30 Non-adjacent Channels Min. db 50 Directivity Min. db 50 Optical Return Loss Min. db 45 PDL Max. db 0.1 Thermal Stability Max. db/ C 0.006 Thermal Wavelength Drift Max. nm/ C 0.003 Operating Temperature C 0 to 65 Storage Temperature C -40 to 85 Package Dimension mm 80x60x12 Maximum Power Handling mw 300 Note 1: All specifications referenced without connector 15

Advantages - Precision sleeves and keys - Excellent detachability - High technical performance - High linearity

attenuators Product information The Seikoh Giken attenuator comes as a self-contained in-line unit, with an 8 angle polished male and female connector. Attenuation is generated by attenuating fiber and provides a controlled attenuation over a very broad bandwidth. The low return loss and high temperature range ensures excellent performance in the most demanding applications. Attenuators ATTN-FC/APC-205-X ATTN-SC/APC-X ATTN-LC/APC (Plastic) Fiber type Single mode 9/ 125 μm Single mode 9/ 125 μm Single mode 9/ 125 μm Wavelength 1250-1650 nm 1250-1650 nm 1250-1650 nm Connector 8 angle polished 8 angle polished 8 angle polished Housing Metal Metal Metal Attenuation Nominal attenuation 1-10 db 11-20 db 1-10 db +/- 0.5dB 11-20 db +/- 5% 1-10 db 11-20 db 1-10 db +/- 0.5dB 11-20 db +/- 5% Back Reflection >60dB >60dB >60dB Other attenuator types are available on request Fixed 1, 2, 3, 4, 5, 6, 10, 15, 20 db 1-10 db +/- 0.5dB 10-15 db +/- 5% -20 db +/- 1 db 17

Advantages - Precision sleeves and keys - Excellent detachability - Low insertion loss

adaptors Product information Adaptors from DKTCOMEGA are designed and manufactured according to JIS, IEC, EIA/TIA and ANSI specifications for optimal performance and connectivity. The low insertion loss properties and easy fit characteristics of these adaptors make this type of fiber optic connection a durable solution for optical patch panels etc. Adaptor Combination Type Sleeve Material Adaptor Material SC/APC SC/APC Square Zirconia Green plastic body and flange w. metal clips SC/PC SC/PC Square Zirconia Blue plastic body and flange w. metal clips SC/APC - SC/APC, Duplex Square Zirconia Green plastic body and flange w. metal clips FC/APC FC/APC DD type, Narrow key 2.05mm Zirconia Metal body and flange FC/APC FC/APC Oval type, Narrow key 2.05mm Zirconia Metal body and flange FC/PC FC/PC DD type, Wide key 2.40mm Zirconia Metal body and flange E2000/APC E2000/APC Square Zirconia Green plastic body and flange w. metal clips E2000/PC E2000/PC Square Zirconia Blue plastic body and flange w. metal clips Other adaptor types are available on request 19

Advantages - Extended (3 coupling panels per 1U) and rodent protected version available - Bend radius protection allows management and rearrangement of cable slack - Accommodates up to 24 fibers in 1 rack unit - Removable top provides unrestricted access - Pivoting shelf eases connector routing and cable routing - Accepts the industry's most common connector types

cable network panels Product information The DKTCOMEGA Cable Network Panels are economical rack-mountable patch panels for use with manufactured pigtails or field-installable connectors. Cables are strain-relieved at the rear of the unit. A shelf equipped with either splice tray holder or bend radius protection guides, stores and organizes excess slack. This prevents damage to fibers prior to routing into couplings. The CNP is used in installations where space is limited. Type Description Item No. CNP-1U-S Standard Cable Network Panel with two panel openings on front 69915 Type Description Item No. CNP-1U-E Extended Cable Network Panel with three panel openings on front 69916 Type Description Item No. CNP-1U-P Standard Cable Network Panel with two panel openings on front and rodent protection 69917 Type Description Item No. MCMH-3S-LP DKT Cable Network Cabinet 69730 MCMH-6S-LP DKT Cable Network Cabinet 69735 Type Description Item No. CNP-1U-SPLICE Splice cassette for 12 splicing. Option for CNP series 69918 Type Description Order No. CNP-1U-BRP Bend Radius Protectors. Option for CNP series 69919 21

Advantages - Compatible with all standard adaptors - High port density - Singlemode and Multimode - Easy installation - Panels with RJ-45 sockets: available for copper twisted pairs

coupling panels Product information Our Fiber Optic Coupling Panels are manufactured from an aluminium sheet metal. They accommodate all the standard fiber optic couplings and hybrid adaptors. We offer a series of high density coupling panels that fit all our fiber management products. These Coupling Panels are available with a variety of standard coupling styles and counts. Custom coupling panels can be designed to suit your needs. Fiber optic panels Type Numbers of adaptors fiber capacity Item No. CNPM-ST-06 6 x ST type 6 69933 CNPM-ST-08 8 x ST type 8 69934 CNPM-FC-06 6 x FC type 6 69935 CNPM-FC-08 8 x FC type 8 69936 CNPM-SC-06 6 x SC type 6 69937 CNPM-SC-08 8 x SC type 8 69938 CNPM-DSC-06 6 x duplex SC type 12 69939 CNPM-E2-06 6 x LSH (E2000) type 6 69940 CNPM-E2-08 8 x LSH (E2000) type 8 69941 CNPM-E2-12 12 x LSH (E2000) type 12 69942 CNPM-MJ-06 6 x MT-RJ type 12 69943 CNPM-DLC-06 6 x duplex LC type 12 69944 CNPM-DMU-06 6 x duplex MU type 12 69945 CNPM-00 Blank panel 69946 Note: Excl. adaptors RJ-45 socket panels Type Numbers of adaptors Fiber capacity CNPM-STP-06 6 x RJ-45 (STP) Supplied including RJ-45 sockets CNPM-UTP-06 6 x RJ-45 (UTP) Supplied including RJ-45 sockets Note: Excl. adaptors Samples of Coupling Panels 23

www.dktcomega.com