Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

Similar documents
Achieving More Efficient Data Review with OpenLAB CDS

GCxGC Comprehensive Two-Dimensional Gas Chromatography

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Creating and fully utilizing the retention time standard processing method for a more automated IC workflow

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Overview and Interpretation of D7900/D7169 Merge Analysis

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

PAL LSI - Robust and Reliable Sample Handling

If you have questions or problems in providing anything described as Customer

How Quadrupole Size Affects Research

How to migrate a DCS without a plant shutdown? whitepaper

Liquid Chromatography- Mass Spectrometer Manual

PAL LSI - Robust and Reliable Sample Handling

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

SmartMix Manual V5350A

Instrument Control and Data Acquisition with Chromeleon

Assay Creosote Extraction of Selected Posts from the 1958 Cooperative Test After 50 Years of Exposure as a Ground Contact Preservative

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

ICS-3000 System Installation Qualification

MAKE HAZARD ANALYSES BETTER SINGLE-USE DEVICES GAIN PERMANENT PLACE PATH FOR PROCESS SAFETY EMERGES

Special Specification 6293 Adaptive Traffic Signal Control System

AIM INTRODUCTION SIMPLIFIED WORKFLOW

"METPOL" An automated system for the analysis of blood alcohol levels. D.A. Rudram

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Staying Connected in GC

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

UNITY 2 TM. Version 1.0. February 2008

Power Performance Drill Upgrades. TorqReg. ARDVARC Advanced Rotary Drill Vector Automated Radio Control. Digital Drives Upgrade

Digital Video Engineering Professional Certification Competencies

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Overall vibration, severity levels and crest factor plus 3 CF+ White Paper

Practicality and Performance

GC/LC-MS: data acquisition rate and peak reconstruction

STANDARD OPERATING PROCEDURE:

V9A01 Solution Specification V0.1

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

SPEAR 3: Operations Update and Impact of Top-Off Injection

Online Control System Migration of Industrial Centrifuge Project Description

Software Operation Manual

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

ChromQuest 5.0 Chromatography Data System

Beginners How to Test DSO138mini

BR2517B. 168 Diode Array & 166 Programmable Detector Modules. Packaging Processing. Bid on Equipment

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Peak Detection with Varian Star Workstation for Varian 3800 and 450 Gas Chromatographs

Reciprocating Machine Protection

YXLON Cougar EVO PLUS

Optimized productivity through automation

800 Displaying Series Flowmeter

Capsule Filling and Closing Machine GKF 2500 ASB - GKF 2500 ASB IPK - GKF 2500 ASB 100%

Packaged Designs, Products & Solutions

Designing Intelligence into Commutation Encoders

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Bruce Quimby. Agilent Technologies October 28, For Forensic Use. Page 1

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

InSight Pro. Valuable real-time process insight

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

Ecoline S Series. Efficient solutions for quality production. Innovations for a better world.

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

NGC8206 Start-Up Guide

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

Peerless Forming Die Test Press Hydraulic Motion Control System

How to Implement PoE in Your Harsh Industrial Environment

Engineered to meet your needs T he oldest name in stud welding,

Agilent 7000 Series Triple Quadrupole GC/MS System

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

Real-Time PCR System TC

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

PRIMEROYAL Series. Metering Pump. Model PN

CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145

FlexSpot Modular robotic spot-welding cells

OpenAir. Air damper actuators for power and flexibility. Building Technologies

Overall vibration, severity levels and crest factor plus

Instrument Status Review. GSC Meeting October 2009

BER MEASUREMENT IN THE NOISY CHANNEL

High performance Internal Mixers Mixing lines Peripheral equipment

-1.1/49 0 C. 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 06TS**

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

istep STEPPER MOTOR PUMP

Oak Ridge Spallation Neutron Source Proton Power Upgrade Project and Second Target Station Project

UNIGAS Hand-held combustion gas analyzer with 3 sensors

FOR MEDIA SAMPLING INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Cie L*48.57 a* b* Covering the World. Solutions for paint and coatings color management

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

How to Match the Color Brightness of Automotive TFT-LCD Panels

R&S RT-ZM Modular Probe System

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Supervision of Analogue Signal Paths in Legacy Media Migration Processes using Digital Signal Processing

Transcription:

Falcon Analytical makers of the... Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection John Crandall, President Ned Roques, Chief Chromatography Engineer 1

Quantitative Chemical Analysis Fischer and Peters, Third Addition - August, 1968, page 3 The Methods of Quantitative Analysis A complete quantitative determination generally consists of four major steps: Obtaining a sample for the analysis Separation of the desired constituent in a measurable form Measurement and calculation of the results And drawing conclusions from the analysis. 2

Quantitative Chemical Analysis Fischer and Peters, Third Addition - August, 1968, page 10 Sampling In practical situations, however, obtaining a sample suitable for analysis is often a source of major difficulty and frequently limits the validity of the final result. Thus NeSSI But it isn t a magic bullet! 3

Modern Analyses, Legacy Baggage Product Certificate of Analysis (C of A) Requirements Contracts require continuity when implementing new analysis technology Results based on decades old methods were still desired by the customer and therefore the supplier Older technology limited analytical improvements and process improvements Requirements for moving forward Composition analysis for composition control in line with legacy C of A Fast analysis Complete automation Results the same as before or at least correlating to C of A 4

An Example: Food Grade Fatty Acid Boiling Range Distribution for Batch Process Endpoint Determination Legacy lab method Completely manual Sample prep Syringe injections Manual integration meeting C of A requirements NOTE strange baseline assignments Modern process method Automated Manual derivatization Automatic injection Automatic integration, C# distribution & report NOTE fully automated baseline assignments 5

The Problem: Three Olefin Process Streams Historically controlled by plant laboratory analysis Using GC/MS technique producing the C of A Results discontinuous and no better than one per four hours Controls from T, P & F running nearly compositionally blind Requirements for moving forward Online, representative, repeatable sampling Fast analysis Full automation from sample tap to the DCS connection Results the same as before using more realistic process GC/FID analysis 6

The Solution: NeSSI, Fast GC, Smart SW Feasibility testing was done on all three olefin streams Plant support lab demo unit was installed next to the GC/MS Three month data comparison campaign demonstrated probable correlation Fixed retention time based cuts were required on normalized, aligned chromatograms leading to the next step Methods development for all 3 olefin process streams Repeatability determination as well as correlation with C of A Demonstrate integrated alignment and process analyzer control SW The results All testing demonstrated a high probability of successful implementation 7

Example Initial Chromatographic Results Separation Resolution is excellent Run time shown is about 400 seconds Later reduced to 5 minute cycles on two streams The 3 rd was optimized at 3 minutes Fixed retention time cuts required Lots of olefinic isomers Cuts shown using area normalized calculations matched GC/MS data Retention time variance cannot be tolerated using normalized area %s The project moved forward 1 2 3 4 5 6 8

Final Chromatography for 3 Olefin Streams The products are Low boiler Intermediate boiler High boiler Optimized cut points Area normalized Pure retention time based using LineUp Correlates well with C of A Results: a good control tool!!! 9

System Overview: 3 Sided Shelter, NeSSI on Back 10

Modular Simplicity: Sampling & Instrument Modular single stream NeSSI with auto-validation Modular single valve, single column, single detector analyzer 11

Modular Simplicity: Analyzer & Systems Process Analyzer Module Three Sided Shelter 12

Modular Simplicity: Calidus Process Analyzer Plug & Play Calidus Instrument The GC is simply a normal Calidus model secured to the slide out tray. Connection Facilities Quick connections on the right side utility panel enables complete Calidus GC modules (models) to be removed and replaced with a backup system. Enclosure Safety NEC Class 1, Division II, Groups C & D via Z-Purge. 13

Modular Simplicity: Software & DCS Reporting Modular Analyzer Control Software: ChromPerfect, LineUp, CPPC MODBUS Computer Communications 14

Simple: Trouble free. Even I can do it? Not so fast! This isn t the sample point 3 process sample points 3 sample probes 3 sample pumps 3 process pumps right? Wrong! Each stream has 2 process pumps One each is in service One each is in maintenance There are really 6 process pumps Each stream has a shut off valve network enabling flow Discharge and/or Suction 15

From the Sample Point to the DCS Connection Sample system includes Process pumps Valve network Transport tubing to the shelter Booster pumps at the shelter Transport tubing back to process pumps Valve network It also includes proper operations The valve networks can be set for Reverse flow to the shelter Backwards operations Instead of forward flow it happened 16

The Sentence Preceding however Sampling Therefore, the analyst seldom needs to be concerned in his laboratory work with the operation of sampling. In practical situations, however, obtaining a sample suitable for analysis is often a source of major difficulty and frequently limits the validity of the final result. In Process Analytical Chemistry, everyone must be concerned with sampling! Even process operating personnel. So what are the results? 17

Stable Operation Is Critical Q1 Visit: part of last run showing 60 to 140 seconds Retention time alignment by Infometrix LineUp implemented dimer, trimer & tetramers of olefinics 101 seconds 18

Stable Operation Is Critical Q1 & 2 Visits Overlaid: part of last run showing 60 to 140 seconds 101 seconds 19

Stable Operation Is Critical Q1, 2 & 3 Visits Overlaid: part of last run showing 60 to 140 seconds 101 seconds 20

Stable Operation Is Critical Q 1, 2, 3 & 4 Visits Overlaid: part of last run showing 60 to 140 seconds Of course operating processes show compositional variance. However, the retention times don t! One year RT drift using Infometrix LineUP ZERO Peak to peak RAW (without LineUP) drift 0.6 seconds for a WHOLE YEAR!!! 4 th chromatogram is after > 175,000 runs with ZERO downtime, no sample valve rotor nor column change nor detector maintenance ZIP 21

Modular Intraflow NeSSI, Modular Calidus GC, Modular Calidus Process Analyzer With attention to the details, trouble free results can be achieved! Questions? 22