DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

Similar documents
USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

MULTIS L72. Operating instructions

Clamp 200 A AC/DC (+ V AC/DC + Ω)

REGO Start&Go USER MANUAL

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

PRINCIPLES AND APPLICATIONS

multi-function meters

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Standard RS232 RS ma

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Certificate of Calibration

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

User Manual Power and Harmonics Analyzer Model PQ3350

LED Driver Linear / area fixed output

Gamma instabus. Technical product information

02/11/2015

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SCALE & WEIGHT DISPLAYS

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Model IQ4-PC User Manual Revision Date:

User Manual. Power and Harmonics Analyzer Model PQ3350

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

Modular pulse operated latching relay 16 A

AT450SAW Programmable Selective Amplifier

LED Driver Compact fixed output

Process Transmitter RMA 422

ELECTRONIC HARMONICS METER RELAY

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Capacitors and banks 50 Hz 0 400/415 V network voltage

LED Driver Compact fixed output

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Measurement and Instrumentation

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

OM2000N INSTALLATION MANUAL

Operating instructions Electronic preset counter Type series 717

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LED Driver Compact dimming

Dimming actuators GDA-4K KNX GDA-8K KNX

Ordering details. Approval. Classification

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

POWER FACTOR REGULATOR

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

SAFETY TERMS AND SYMBOLS

ELECTRONIC MULTI METER

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Standard signal metering in wall-mounting case

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

TRF STEP-DOWN TRANSFORMER USER MANUAL

Cronotermostato Digitale

Sensopress LCD Special English

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Electrical connection

Solis Export Power Manager

K3NX Process Meter OPERATION MANUAL

LED control gear Compact fixed output

Power Circuit of a UL508A Panel. Typical UL489 Application

Process transmitter RMA422

AT47SAW Programmable Selective Amplifier

LAUREL ELECTRONICS, INC.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Style 5S Clock / Timer

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

ANALOGUE METERS FOR MARINE APPLICATIONS

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Operating Manual RISH OPTIMA VAF

48x24. Options ORDER NUMBER OF TYPE PFL B

INSTALLATION & USER GUIDE

KNX Technical Reference Manual Busch-EnergyControl

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

ISO-TECH IPM3005 Flexible AC Power Quality Tester Instruction Manual

Digital differential Pressure switch Model DPS Instruction manual

Level Measurement silometer FMC 420, FMC 423

ADJUSTABLE SPEED DRIVES. nc1 Drive

LED Driver Compact fixed output

FRQM-2 Frequency Counter & RF Multimeter

Electronic converter for level transmitters MT03L Instructions manual

EB 3000 as of Version 1.7

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

MT03A Electronic converter for flow rate transmitters

True RMS AC/DC Mini Clamp Meter

G 400 CURRENT GENERATOR. programmable, ± points. User handbook Valid for instruments with version 01.xx

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

ScopeMeter 190 Series Specifications

Capacitance Level Measurement Electronic insert FEC 12

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Rack mounted telephone- and leased line modem for industrial applications

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Backlight for Technics amplifiers

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Transcription:

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL Introduction The instrument DUCA47-96 is a digital multimeter for panel mounting that allows the measurement of the principal electrical parameters in three-phase 230/400Vac networks and single-phase networks, including the max/min/average detection of the main electrical parameters and the active and reactive energy count. The different measured variables are displayed locally on four red 7-segment LED displays providing easy readability and simultaneous display of multiples measures. The DUCA47-96 combines also (in a single instrument) the functions of a voltmeter, ammeter, power factor meter, wattmeter, varmeter, frequency meter, active and reactive energy meters, allowing remarkable financial savings thanks to the reduction of space required for the panels and also of time required for cabling. Main functionalities Compact dimensions, for panel mounting 96x96, with 4 LED s display with 7 segments, for an excellent reading of the measurements Scan of the measures and indication of the visualised parameter with the switching on of the correspondent LED True RMS measurements Active and reactive energy count and storage of the maximum, minimum and average values with an integration period of 15 minutes High accuracy of the measurements thanks to oversampling tecniques and automatic calibration process 68 total measurements with Energy-Analyser s functions User selectable default displayed page both for single line (display L1, L2 and L3) and three-phase system (4-th display) displays, visualised after about 1 minute of inactivity 1

Automatic detection of CTs current flow direction for an easy installation of the system. If the operator makes a mistake during CTs installation (inversion s error), at power-up the instrument detects automatically the correct flow of the current, adjusting the error, in an independent way for each phase 2 time counters (hours and minutes). The first counter t1, resetable from the configuration menu, increases regularly and can be use as instrument s working time indicator; the second counter t2 continue counting down from the set value and can be use for maintenance reminder when it reaches the 0 value (than it decreases with negative values, showing the delay from the expiry programmed time) Assembly instructions a) Set the device in the hollow frame and push till the surfaces touch one another b) Lock the red spring mounts in the locking slids (1) c) Push the red spring mounts (2) to lock the frame to the device (to unlock the springs pull slightly the spring vertical edge in order to unlock the blocking tooth and slide back the spring itself) Terminal board connection and examples of connections Pin Power Supply Description Pin Current Inputs Description Pin Voltage Inputs Description 0 0 ~ Power-supply S2-I1 S2 input I1 N N Voltmeter inputs 115 115 ~ Power-supply S1-I1 (*) S1 input I1 L1 L1 Voltmeter inputs 230 230 ~ Power-supply S2-I2 S2 input I2 L2 L2 Voltmeter inputs S1-I2 (*) S1 input I2 L3 L3 Voltmeter inputs S2-I3 S2 input I3 S1-I3 (*) S1 input I3 (*) In case of connection of the secundary of the CTs to Earth, only the pins S1-I1, S1-I2 and S1-I3 must be connect to Earth. NOTE: the CURRENT INPUTS terminal block is removable-type terminal fixed on the instrument with screws, we advise to screw down the terminal block after the installation to lock it and avoid unwanted extractions. 2

Three-phase direct connection with neutral Single-phase direct connection NOTE: in single-phase connection the Threephase measurements are not significant. Three-phase indirect conn. with neutral with 3VTs and 3 CTs NOTE: the use of the VTs in star connection is optional if the user want lower voltages on the electric measurement panel or need a further galvanic insulation. 3

Three-phase indirect conn. without neutral with 3VTs and 3 CTs NOTE: the use of the VTs in delta connection is optional if the user want lower voltages on the electric measurement panel or need a further galvanic insulation.in this cases is not allowed the connection of any of the phases of the VT s secundary to Earth. Instrument s description 1 5 Three-phase indirect conn. without neutral with 2CTs and 2VTs NOTE: the use of the VTs is optional if the user want lower voltages on the electric measurement panel or need a further galvanic insulation.in this cases is not allowed the connection of any of the phases of the VT s secundary to Earth. 9 7 8 3 6 2 4 Display L1, L2, L3 for the visualisation of the electrical parameters of every phase, of the energy counters and the time counters (energy and time counters are visualised in sequence on the displays L1, L2 e L3; L1 holding the most significant digits and L3 the less significant digits) 4-th display for the visualisation of the electrical parameters of the three-phase system Key for the scan of the electrical parameters for each phase and the energy counters, visualised on the displays L1, L2, L3 ( ), if you press-and-hold-down the previous page will be displayed Key for the scan of the three-phase electrical parameters, visualised on the 4-th display ( ) and the time counters, if you press-and-hold-down the previous page will be displayed 9 LEDs for the indication of the electrical parameters displayed on the three displays L1, L2, L3 ( ) 4

7 LEDs for the indication of the electrical parameters displayed on the 4-th display ( ) Key for set out the visualisation of maximum values of the electrical parameters (LED MAX switched on), of minimum values (LED MIN switched on) and average values (calculation period of 15 minutes) (AVERAGE, simultaneously LED MIN and MAX switched on). When the LED, wich shows the selected type of visualisation, is switched on, it will be possible to scan in sequence the different electrical parameters by pressing and keys LED for the identification of the visualised electrical parameters scale on both instrument s displays and (K = kilo, parameter x 1.000, M = mega, parameter x 1.000.000) LED for the identification of the max/min/average values displayed on the displays e + Press together allow the access to the configuration menu (setup) Instrument s functionalities The indication Σ refers to the three-phase measurements of the correspondent parameter. MEASURED PARAMETERS Phase-to-Phase Voltage (VL-L) Line and Three-Phase Voltage (VL-N e ΣV) Line and Three-Phase Current (A e ΣA) Frequency Line and Three-Phase Active Power (W and ΣW) Line and Three-Phase Reactive Power (VAr and ΣVAr) Line and Three-Phase Apparent Power (VA and ΣVA) Line and Three-Phase Power-Factor/cosϕ, with indication of the conventional sign (+ = Inductive Load, - = Capacitive Load) Active and Reactive Line and Three-Phase Energy counters (visualisation concatenated on the displays L1, L2 e L3) MAXIMUM DISPLAYED VALUES Line Voltage (VL-N) Line Current (A) Line and Three-Phase Active Power (W and ΣW) Line and Three-Phase Reactive Power (VAr and ΣVAr) Line and Three-Phase Apparent Power (VA and ΣVA) MINIMUM DISPLAYED VALUES Line Voltage (VL-N) Line Current (A) Three-Phase Active Power (ΣW) VL1-L2, VL2-L3, VL3-L1 VL1-N, VL2-N, VL3-N, ΣV I1, I2, I3, ΣI Hz W1, W2, W3, ΣW VAr1, VAr2, VAr3, ΣVAr VA1, VA2, VA3, ΣVA PF1, PF2, PF3, ΣPF kwh-l1, kwh-l2, kwh-l3, ΣkWh-3P kvarh-l1, kvarh-l2, kvarh-l3, ΣkVArh-3P VL1-N, VL2-N, VL3-N (MAX) I1, I2, I3 (MAX) W1, W2, W3, ΣW (MAX) VAr1, VAr2, VAr3, ΣVAr (MAX) VA1, VA2, VA3, ΣVA (MAX) VL1-N, VL2-N, VL3-N (MIN) I1, I2, I3 (MIN) ΣW (MIN) 5

Three-Phase Reactive Power (ΣVAr) Three-Phase Apparent Power (ΣVA) ΣVAr (MIN) ΣVA (MIN) AVERAGE DISPLAYED VALUES (INTEGRATION PERIOD 15 MINUTES) Line and Three-Phase Active Power (W and ΣW) Line and Three-Phase Reactive Power (VAr and ΣVAr) Line and Three-Phase Apparent Power (VA and ΣVA) W1, W2, W3, ΣW (AVG) VAr1, VAr2, VA3, ΣVAr (AVG) VA1, VA2, VA3, ΣVA (AVG) TIME COUNTERS Hours counter (hours and minutes) free-running resetable from setup menu, variable in the range 0 10000000 hours (visualisation concatenated on the displays L1, L2 e L3) Hours counter (hours and minutes) count-down for maintenance reminder (visualisation concatenated on the displays L1, L2 e L3), selectable in the range 1 32000 hours (when the counter reaches zero than it shows negative values until - 32000, indicating the delay from the expiry programmed time) NOTE: Sometimes, when installing the device at the first time, due certain events or wrong maneuvers, or in case of not efficient non-volatile memory (E2prom), the instrument stops and a page with the writing INI on the first three displays will be displayed, following by an internal identification code. Pressing any key will set the default parameters, which may be changed by the user as required. In any case contact always the Ducati assistance for instrument s maintenance. Instrument s configuration menu (setup) To access to the instrument s configuration menu press together and keys, when the writing SETUP is visualised on the first three displays, press the key. In the configuration menu the keys have the following function: Increases the selected parameter (two-speed autorepeat if hold down); in the reset pages it allows the reset of the selected parameters Decreases the selected parameter (two-speed autorepeat if hold down) Confirms modifications and steps to the next page; if you press-and-hold-down, the previous page will be displayed The displayed pages (in sequence) in the configuration menu are the following: Ct rat : set of the transformation ratio of CTs (KA), variable in the range 1 1250, factory default value 1. For example if you have a 800/5A CT, you must insert the value 160 Ut rat : set of the transformation ratio VT (KV), variable in the range 1 500, factory default value 1 PAG 1.2.3. e PAG 4. : number setting of the default displayed page, 0 15 on the first three displays, factory default value 1; 0 7 on the 4-th display, factory default value 1; 0 = it remains the last selected page t2 : setting in hours of the count-down value of the hours counter t2, factory default value 8760.00 (1 year) reset PEA (PEAK = Peak Values): maximum and minimum values reset (to reset see note below) reset AUG (AVG = Average): average values reset (to reset see note below) reset En (En = Energies): energy counters reset (to reset see note below) reset t1 : hours counter t1 reset (to reset see note below) reset ALL : restore the default configuration and resets all the parameters (min/max values, average values, energies, t1 counter) - (to reset see note below) 6

rel : instrument s firmware revision NOTE: to perform the previous described resets, from the correspondent page, hold down for some seconds the key until the visualisation of the -C- -L- -r- writing appears on the first three displays the peak values, the average values, the energy counters and the values of the counters t1 e t2 are maintained in the instrument memory in case of power failures Technical characteristics DIMENSIONS Panel mounting model: 96 mm x 96 mm x 103 mm (LxHxW) IEC 61554 WEIGHT About 500g PROTECTION IP50 on the front panel IP20 on the terminal blocks POWER-SUPPLY Voltage Frequency Power consumption Fuse 230V rms (+15% -10%) 240V rms (+10% -15%) 115V rms (+15% -10%) 120V rms (+10% -15%) VOLTMETER INPUTS Range Max non-destructive value L-N input impedance AMMETER INPUTS (USE ALWAYS EXTERNAL CTs) Range Overload Max dispersed power (with Imax = 5A rms), for each phase input Type of measurement Direction of CTs current ACCURACY OF THE MEASUREMENT Voltages Currents Active power Frequency 45 65Hz < 6VA Fit external fuse T0,1A 10 500V rms (L-N) 550V rms Greater than 8MΩ 50mA 5A rms 1,1 permanent 1,4VA Current inputs through internal shunts and using external CTs Detection and automatic adjustment at power up, independent for each phase ±0,5% F.S. ±1 digit in the range 10Vac 500Vac rms VL-N ±0,5% F.S. ±1 digit in the range 50mA 5A rms ±1% ±0,1% F.S. (from cosφ = 0,3 Ind. to cosφ = -0,3 Cap.) 40.0 99.9Hz: ±0,2% ±0,1Hz 100 500Hz: ±0,2% ±1Hz 7

ENERGY COUNT Maximum value for the single-phase energy 4294,9 MWh (MVArh) with KA = KV = 1 Maximum value for the three-phase energy 4294,9 MWh (MVArh) with KA = KV = 1 Accuracy Class 1 OPERATIVE CONDITIONS Operating temperature 0 C 50 C Storage temperature -10 C 60 C Relative humidity 90% max. (without condense) at 40 C REFERENCE NORMATIVES LOW VOLTAGE EC directive No. 73/23/CEE: compliance with EN 61010-1 regarding hygroscopic pre-conditioning, dielectric rigidity and residual voltage ELECTROMAGNETIC COMPATIBILITY EC directive No. 89/336/CEE: compliance with standard EN61326-1 CONFIGURATION MENU Parameters Possible values Factory default VT transformation ratio 1 500 1 CT transformation ratio 1 1250 1 PAG 1.2.3. (default page for displays L1, 0 15 1 L2 and L3) (0 = it remains the last displayed page) PAG 4. (default page for the 4-th 0 7 1 display) (0 = it remains the last displayed page) Free-running counter t1 (hours and minutes) The counter can be reset from the configuration menu The counter work in the range: 0 10000000 (hours) (about 1140 years) Count-down counter t2 (hours and minutes) Initial set in hours: 1 32000 (about 3,5 years) 8760 hours (1 year) Calculation period for mean values (minutes) - 15 minutes DUCATI Sistemi S.p.A. shall not accept no liability for damage or personal injury arising from incorrect or improper use of its equipment. In line with a policy of continuous improvement, DUCATI Sistemi S.p.A. reserves the right to implement changes to this manual without prior notice. Document code: DUCA47-96_V0RD_ENG.doc - Version 0, Revision D May 2008 Via M. E. Lepido, 182 40132 Bologna Italia Tel.: +39 051 6411511 Fax: +39 051 6411690 WEB: www.ducatisistemi. com E mail (Commerc.) = info@ducatisistemi.com // E mail (Technical) = Supporto_Analizzatori@ducatisistemi.com 8