Media Tube HO RGBW Million additive RGB colors; White CCT 6500K. Algorithms enable auto control of white LED by 3-channel RGB values.

Media Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K

Media Tube HO RGB. 896mm mm mm kg 1.8lbs. 0.4kg 0.9lbs. 1.24kg 2.7lbs. 1.02kg 2.3lbs

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

Dot XL-6 RGB. Dot XL-9 RGB with

Dot XL-3 RGB. 3 High intensity Nichia SMT LEDs per dot Million additive RGB colors bit (Gamma correction)

Dot XL-6 RGB Dot XL-9 RGB

Dot XL-3 CW/WW is an extra bright dot with 3 high performance LEDs

Liner Quattro AC XB RGBW

1PXL Board CW/WW/DW. Power Consumption 8W max. 8W max. 15W max.

Cove Light AC DIM GII

FLUID VIEW 12V LED TAPE LIGHT

Luminaire SIGNATURE SERIES

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

COLORBLAST 12 POWERCORE

36 High intensity RGB LEDs. UL/C-UL listed, CE. communication Specifications. Environmental Specifications

LED Spot 300W. Please read this user manual before your operation

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

LED Thunder S-150 Code 1097

Mini LED Pin Spot Light Model: PLS00571

SquareLED - Aura Bar & Matrix Beam Light 100

Video Micro Converter

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

INSTALLATION INSTRUCTIONS RGB / RGBW 24V LED TAPE

Cyclo Series. user manual. MartinArchitectural

User Guide. HDMI Fiber Optic Extender. DVI-7350a

R Rxx-Vxxxx-L334-x

EZ-STATUS WLS28-2 Multicolor LED Strip Light

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Litile34 OPERATION MANUAL

Cyclo DMX HO High Output. user manual

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

LED MODULES READYLINE DL

COLOR POWER SERIES DA CL9 VEGA

Spectra Batten (Order code: LEDJ95)

User Guide. HDMI Active Cable Extender. DVI-7370c

ew FLEX SLX SPECIFICATIONS Polycarbonate, approx.1.10 x 1.22 x.56 H (2.97 cm x 3.12 cm x 1.4 cm) UL/cUL, CE COMMUNICATION SPECIFICATIONS

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

WLC60 Heavy Duty LED Light - PWM Dimmable

VGAD-12 ORDERCODE

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

POWER LINE BAR SERIES DA PL6 WW NORA

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LUXFLEX FLEXIBLE, COLORFUL BACKLIGHTING

R xx-C0900-J074

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

Features. High Brightness SMD LED Light source

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

DMX Operator 192-channel lighting controller

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Fusion 120 Zoom. User Manual. Order code: EQLED068

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

Stratos Duo RGB. User Manual. Order code: EQLED371

Chip3 Inline Ultraslim RGB Multi Pixel

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

Stage Wash 7x 10W LED Moving Head (RGBW)

LED Spere Direct Control 30 ORDERCODE 41125

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

DLE C-201. Actual Size

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Hex-color RGBAW+UV LED strip light

MONOPRICE. SoftStage 80-Watt COB LED Stage PAR (RGB) with 30 and 80 Lenses. User's Manual P/N

WLS27 Multicolor LED Strip Light with EZ-STATUS

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

LED Pixel Track V3 ORDERCODE 42200

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

USER MANUAL Table of Contents

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

LED Floodlight 6x 1W, 40 ORDERCODE ORDERCODE ORDERCODE ORDERCODE ORDERCODE ORDERCODE 42760

USER MANUAL Table of Contents

LED control gear Compact fixed output

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

LED Pixel Track Pro ORDERCODE 42205

Chroma-Q Color Block PSU-30

LED Par 56 Short Eco V2 ORDERCODE 42417

BROTHER, BROTHER & SONS

Colour Explosion Proof Video Camera USER MANUAL VID-C

Truss Light COB LED 30W

thinpar 38

Indoor/Outdoor Security System with Quad Monitor User s Manual

PIXEL NET 4. user manual. ELATION PIXEL NET 4 user manual

LUXPOINT TM MIDI 6 LED Downlight Data Sheet

SmartCrystal Cinema Neo

pixelpatt Light source 7x 30W RGBW multichips Effects Individual control of each RGBW pixel, Tungsten lamp emulation

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Transcription:

Media Tube HO INSTALLATION GUIDE V1.0 Cover: Media Tube HO RGBW/RGB/White Direct View Media Tube HO RGBW/RGB/White Diffused

CONTENT 1. INTRODUCTIOn 3 2. installation 6 3. SAfety And Operation 13 4. System configuration 14 5. Care and Maintenance 20 6. TroubleshootinG 21 7. TECHNICAL SPECIFICATIOn 22 8. Warranty StatemenT 22 For your own safety and that of the product, please read this installation guide carefully before beginning setup and installation. Installation Guide 10/16 V1.0 2 of 26

1. 1.1 INTRODUCTION General MEDIA TUBE HO RGBW DIRECT VIEW MEDIA TUBE HO RGBW DIFD Length (mm) Maximum number of pixels (PXL) TU.CS.1112001 TU.DS.1112001 296 12 TU.CS.2124001 TU.DS.2124001 596 24 TU.CS.3136001 TU.DS.3136001 896 36 TU.CS.4148001 TU.DS.4148001 1196 48 TU.CS.5160001 TU.DS.5160001 1496 60 Media Tube HO is an IP66-rated slim LED tube for any wall or façade media lighting. Available in 296mm, 596mm, 896mm, 1196mm and 1496mm lengths, the simple but robust construction, allows up to 18.6m of tubes to be daisy chained on a single power run. The Media Tube HO is controllable by DMX512 / e:pix / DVI capable with auto-addressing to the next tube in the daisy chain. The Media Tube HO is housed in aluminium extrusion with a clear PC cover for direct view or with a diffused PC cover for diffused view. Features: Available lengths: 296mm (12PXL), 596mm (24PXL), 896mm (36PXL), 1196mm (48PXL) and 1496mm (60PXL) Direct View or Diffused Three color options: RGBW, RGB*, White* (*available upon request) DMX512 / e:pix / DVI capable Daisy Chain System Auto-Addressing SMART CHIP Technology Outdoor Applications (IP66-rated) Installation Guide 10/16 V1.0 3 of 26

Quick Lock Input Cable 1.2 Dimensions FIG.1: Quick Lock Output Cable Media Tube HO Direct View Direct View Tube 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 47.1, 58.9 51.5mm / 2 With Mounting Bracket 36mm / 1.4 23mm / 0.9 109mm / 4.3 69mm / 2.7 DETAIL A 24mm / 0.94 Without Mounting Bracket Quick Lock Output Cable Quick Lock Input Cable 25mm / 1 See DETAIL A Direct View Tube 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 47.1, 58.9 23mm / 0.9 23mm / 0.9 25mm / 1 Quick Lock Input Cable 33mm / 1.3 24mm / 0.94 With Mounting Bracket Quick Lock Output Cable Media Tube HO Diffused See DETAIL B MountingTube Diffused 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 47.1, 58.9 33mm / 1.3 Without Mounting Bracket Mounting 109mm / 4.3 81mm / 3.2 With Mounting Bracket TAK! See DETAIL B 29mm / 1.14 81mm / 3.2 54mm / 2.1 29mm / 1.14 69mm / 2.7 54mm / 2.1 DETAIL B 25mm / 1 With Mounting Bracket Quick Lock Output Cable Quick Lock Input Cable 81mm / 3.2 TAK! 63mm / 2.5 24mm / 0.94 30mm / 1.2 63mm / 2.5 36mm / 1.4 With Mounting Bracket 29mm / 1.14 109mm / 4.3 23mm / 0.9 51.5mm / 2 69mm / 2.7 See DETAIL A 30mm / 1.2 FIG.2: DETAIL B 54mm36mm / 2.1 / 1.4 DETAIL A 24mm / 0.94 30mm / 1.2 With Mounting Bracket 29mm / 1.14 63mm / 2.5 / 2 81mm / 51.5mm 3.2 109mm / 4.3 69mm / 2.7 36mm / 1.4 51.5mm / 2 Diffused Tube Lock with screw 33 33mm / 1.3 25mm / 1 29mm / 1.14 29mm / 1.14 4 of 26 Tube-to-Tube ClearanceLock with screw 1.2 81mm / 3.2 10/16 V1.0 81mm / 3.2 Installation Guide 54mm / 2.1 2016 traxon technologies - AN OSRAM Business. all rights reserved. traxon, tx connect, are trademarks of traxon technologies. u.s. patents, e.u. 63mm / 2.5 With Mounting Bracket 33 To ma

1.3 FIG.3: Packing Contents Packing Contents Media Tube HO (Direct View or Diffused) 2 x Mounting Bracket (4x screws pre-installed) 2 x Screws 2 x Bolts Assortment of nuts and washers Installation Guide 10/16 V1.0 5 of 26

2. 2.1 installation Points To Consider Plan your installation before mounting the Media Tubes HO. The following should be considered for a successful installation. Weather conditions and ambient temperature of installation site. Appropriate cable lengths (cable gauges described in below diagram). Please consult your local Traxon office or authorized agent for necessary aid. The number of Media Tubes HO and appropriate LED Engines. DMX512/e:pix controller to be used to control the Media Tubes HO. Distance between each Tube for thermal expansion and maintaining pixel pitch. There are two mounting methods to consider, plan mounting distances accordingly for whichever method is required. Proper surge protection. Number of standard LED Engines to be used. FIG.4: CABLE A Media Tube HO Cable System CABLE C CABLE B AWG0~6 CABLE D Power: AWG17 Data: AWG24 Ø7.2mm/0.28 AWG24 Power: AWG17 Data: AWG24 Ø7.2mm/0.28 Cable A = Live power cable (from PSU to Power Distribution Block) Cable B = Data cable (from VMC to Terminal Block) Cable C = Starter cable (From Terminal Block to first Media Tube HO in chain) Cable D = Interconnection cable (From Media Tube HO to another Media Tube HO) Installation Guide 10/16 V1.0 6 of 26

2.2 Pre-Installation Checks 2.2.1 Installation Checklist 1. Prepare cables and all necessary accessories (Mounting Brackets, Waterproof Quick Lock End Caps etc). 2. Perform functional check of Media Tubes HO. Take care not to damage cables/ connectors during pre-installation checks. 3. Ensure all pre-installation checks laid out below have been followed. 4. Mount the Media Tubes HO on-site. If the installation is to be left uncompleted overnight, place all non-connected LED Engines and Media Tubes HO in an indoor environment. Ensure all the Interconnection Cables, Media Tubes HO and LED Engines are initially stored in a dry area to guarantee the complete sealing of the system from water before installation. 2.2.2 Cable Bending To reduce stress induced on Media Tube HO lead cables, please adhere to the Minimum Bending Radius of 10mm (0.4 ) and the Non-Bendable Length of 20mm near the connector. It is recommended to install lead cables through conduits/trunking. FIG.5: Minimum Cable Bending and Non-Bendable Length requirement Non-Bendable Length 20mm/0.79 Minimum Bending Radius 10mm/0.4 NOTE: Water ingress incurred due to cable twisting or excess cable bending will not be under warranty by Traxon Technologies. Installation Guide 10/16 V1.0 7 of 26

2.2.3 Mounting Bracket If the Mounting Bracket method of installation is used, it is recommended to fix it to the installation surface before the Media Tube HO is secured to the bracket FIG.6: Media Tube HO Mounting Bracket 25mm / 1 30mm / 1.2 33mm / 1.3 2.2.4 1. 2. Installation Sequence Plan for any possible bending of cables (see Section 2.2.2). Measure the correct distances for Mounting Brackets. 3. Connect Media Tubes HO with LED Engines in the daisy-chain manner outlined in the System Diagram to form large installations. 4. Perform functional check on all Media Tubes HO and inspect cables and Mounting Bracket for any damage. Check for any abnormalities with the control signal. 5. Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install Media Tubes HO with functional defects on-site. Installation Guide 10/16 V1.0 8 of 26

2.3 On-Site Installation DO NOT attempt installation in wet or severe weather conditions. DO NOT leave and expose any Media Tubes HO or LED Engines unconnected under wet/raining or snowing environment. IP failure induced by stressed/damaged cables during or after installation will not be under warranty by Traxon Technologies. ALWAYS keep the cables protected from sharp objects and ensure no damage is generated on the cable. Failure to keep Media Tube HO within the operating temperature range of 30 C to +60 C / 22 F to +140 F and storage temperature range of 40 C to +70 C / 40 F to +158 F will void the product s warranty. 2.3.1 On-Site Installation 1. Fix Mounting Bracket to installation surface with anchor bolts, if Mounting Bracket method is being used. 2. Attach Media Tube HO to Mounting Bracket and affix Mounting Plate (see below diagram). If using the Mounting Studs option, simply secure using anchor bolts (see Mounting options for the Tube FIG.10). FIG.7: Fixing the Mounting Bracket to Installation Surface 1~1.2Nm Installation Guide 10/16 V1.0 9 of 26

81mm / 3.2 54mm / 2 DETAIL B See DETAIL B Mounting 3. The Media Tubes HO are interconnected using the IN and OUT cables on each end of the tube. Screw the connectors tightly for a water-tight seal. Below diagram shows the Tube connections. Always remember to affix an Quick Lock Waterproof End Cap (sold separately) for the OUT connector of the final Tube in each daisy chain. See System TAK! Diagram for details. FIG.8: Media Tube HO Connections 29mm / 1.14 USE REAR STUDS FOR ALTERNAT 4. Starter Cable M6 x 23mm Loosen mounting stud m End cap for OUT water ingression. connector of last tube. NOTE: Any water ingress incurred due to improper installation of cable connectors or Waterproof Quick Lock End Caps will not be under warranty by Traxon Technologies. Be sure not to compress the IN/OUT cables (see Requirements Of Cable Bending). NOTE: To keep LED pitch consistent and allow for thermal expansion, be sure to keep a minimum distance of 4mm (0.16 ) between consecutive Media Tubes HO (see below diagram). FIG.9: Lock with screw Fixing Tube-to-Tube the Mounting Clearance Bracket to Installation Surface 63mm / 2.5 33mm / 1.3 30mm / 1.2 81mm / 3.2 33mm / 1.3 30mm / 1.2 END CAP S >4mm/0.16 To maintain consistent LED pitch and to allow for thermal expansion. 182mm / 7.2 The light source of this luminair When the light source reaches whole luminaire shall be replac Installation Guide 10/16 V1.0 10 of 26

Diffused Tube 36mm / 1.4 54mm / 2.1 81mm / 3.2 23mm / 0.9 5. 29mm / 1.14 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 4 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 47.1, 58.9 Connect Media DETAIL B Tubes HO in the daisy-chained manner as detailed in the System Diagram. There are two mounting options. See DETAIL B FIG.10: Mounting Mounting options for the tube See DETAIL A 24mm / 0.94 69mm / 2.7 109mm / 4.3 USE REAR STUDS FOR ALTE TAK! 29mm / 1.14 54mm / 2.1 296mm, 596mm, 896mm, 1196mm, 1496mm / 11.7, 23.5, 35.3, 47.1, 58.9 33mm / 1.3 M6 x 23mm Loosen mounting stu water ingression. 30mm / 1.2 Lock with screw 81mm / 3.2 See DETAIL B 30mm / 1.2 63mm / 2.5 29mm / 1.14 33mm / 1.3 USE REAR STUDS FOR ALTERNATIVE MOUNTING 6. END C M6 x 23mm >4mm/0.16 30mm / 1.2 Lock with screw 30mm / 1.2 63mm / 2.5 Tube-to-Tube Clearance 81mm / 3.2 29mm / 1.14 To maintainloosen consistent LED pitch mounting stud may lead to and to allow for thermal expansion. water ingression. The first tube of the group 33mm / 1.3 has to be connected to the control system via 33mm daisy-chain / 1.3 the Quick Lock Starter Cable or the RJ45 / Power Data to Quick Lock Injector Cable Kit The light source of this lum 182mm / 7.2 (TU.AC.0600400). When the light source reac whole luminaire shall be re earance END CAP SEAL ON LAST TUBE >4mm/0.16 To maintain consistent LED pitch and to allow for thermal expansion. 2016 traxon technologies - AN OSRAM Business. all rights reserved. traxon, tx connect, are trademarks of traxon technologies. u.s. patents, e.u. Connector End Cap Installation Guide 182mm / 7.2 10/16 V1.0 11 of 26 The light source of this luminaire is not replaceable; When the light source reaches its end of life, the

7. Starter cables, Data and Power cables, and video fiber optic cables have to be installed through conduits/trunking. FIG.11: the right. Bad vs. Good trunking. It is recommended to follow the example on Bad Trunking (will void warranty) Good Trunking (Recommended) 8. Set up the control system indoors as detailed in the System Diagram and connect to the Media Tubes HO outside. Start up each unit and verify correct function. Installation Guide 10/16 V1.0 12 of 26

3. SAfety And Operation CAUTION - Unplug the power supply from the mains power before connecting any cables as this can damage the products. CAUTION - Avoid looking directly into the LED light source at close range for your own safety. Persons installing this product should make sure: 1. The installation complies with all applicable codes, state and local laws, ordinances, standards and safety regulations. 2. The installation environment is carefully studied and suitable surge protection measure(s) is taken. 3. He or she is qualified for the handling of electrical equipment. Do not attempt to install or use the product until installation instructions and safety labels are fully understood. This product is designed for indoor and outdoor use. Ensure product operates within the specified temperature range. (Refer to 7. TECHNICAL SPECIFICATION for more details.) Do not attempt to open the product. Not user serviceable. Do not use the product if any part of it, or the power cables are damaged. Only use product for specified voltage, do not exceed. (Refer to 7. TECHNICAL SPECIFICATION for more details.) Always maintain connection to ensure waterproofing. If the product has been subjected to drastic temperature variances, for example, following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages. When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies. Please study this Installation Guide thoroughly and check the latest Technical Specification Sheets available from the Traxon website before setup. Any non-compliance of the Installation Guide will void the Traxon warranty. Installation Guide 10/16 V1.0 13 of 26

4. System configuration 4.1 MEDIA TUBE HO CONNECTION COMPONENTS The Media Tube HO is connected using a daisy chain system with power and data on the same cable. Below diagram shows some typical components for Media Tube HO system. FIG.12: Connection Components for Media Tube HO System LED Engine 1000W 48V - single terminal PS.IE.0011100 PSU Rack for LED Engine 1000W 48V (Houses 3 x PS.IE.0011100) PS.AC.0500100 LED Engine 320W 48V Outdoor LED Engine 240W 48V Outdoor PS.OB.0011002 281-309 281-335 LED Engine 100W 48V Outdoor PS.CU.0000008 + WAGO Part no. 281-611/281-542 281-656 and 281-512/281-416 (Fuse block) 280-901 1939460000 Weidmüller Terminal Block TU.AC.0000300 280-309 WAGO Terminal Block Set (6A) TU.AC.0000201 Quick Lock Starter Cable Standard Length TU.AC.0600100 Open wire, 5m TU.AC.0600200 Open wire, 20m TU.AC.0600300 Open wire, 35m Custom Length also available 281-309 Adjacent jumper for common GND 281-402 280-309 WAGO Part no. 281-611/281-542 281-611 280-901 Quick Lock Interconnection Cable Standard Length TU.AC.0600500 140mm TU.AC.0600600 1.5m TU.AC.0600700 4m Custom Length also available WAGO Terminal Block Set (7A) TU.AC.0602000 Quick Lock Power / Data Injector Cable TU.AC.0600800 Quick Lock Connector End Cap TU.AC.0600000 Video Micro Converter (DMX/e:pix) 160185 RJ45 / Power Data to Quick Lock Injector Cable Kit TU.AC.0600400 Butler XT2 EN.BX.0000001 Installation Guide 10/16 V1.0 14 of 26

4.2 LED CONTROL The LEDs on the Media Tube HO are controlled by DMX512/e:pix. Each pixel on the Tube uses four (4) channels, for R, G, B and W. Pixel number 1 begin on the IN connector side, and it uses the first four channels. The start address is the next address from the previous tube in the daisy chain. Pixel 1 Pixel 2 RGB BGR W Pixel n Control Channel Number R Tube start address +4(n-1) G Tube start address +4(n-1) + 1 B Tube start address +4(n-1) + 2 W Tube start address +4(n-1) + 3 Where: n is pixel number along the Tube. (Pixel 1 is located near the IN connector.) NOTE: This is applicable for Media Tube HO RGBW 4-channel mode only. For +White / Auto White feature, please refer to corresponding manual. Installation Guide 10/16 V1.0 15 of 26

FIG.13: Media Tube HO RGBW 1000W 7A Fuse Per Daisy Chain System Connection Example Meanwell Power Supply Unit 3x 48V DC 1kW LED Engine 1000W 48V - single terminal Wago Terminal block set (7A) TU.AC.0602000 BACK PSU Rack for LED Engine 1000W 48V (Houses 3 x LED Engine 1000W 48V) 3x 1kW Rackmount PSU Ring connectors can power up to 146.4m tubes (18.3m x 8) to fit M5 terminal Wago Terminal block set on PSU Interconnection Example: POWER INJECTION WAGO terminal blocks LCE2 fx on 35mm wide DIN rail Quick Lock Power/Data Injector Cable TU.AC.0600800 CABLE A Fuse: 7A Slow blow x 2 AWG0~6 Ø5 x 20mm Injecting power for next daisy chain. DVI Source Ethernet Source CABLE C 48V DC TUBES ARE DAISY CHAINED GND Quick Lock Starter Cable Power Distribution DMX+ POWER: AWG17 Blocks Power distribution block DMX DATA: AWG24 Note: Common the GND to Wago Terminal Block Wago terminal blocks CABLE D Interconnection cable using adjacant jumpers. AWG12~14 (1m max) 281-309 WAGO Part no. 281-611/281-542 281-611 Ethernet Switch 280-309 280-901 281-402 249-117 (End stopper) Video Micro Converter (VMC) DVI IN (DVI-D/DVI-I) DVI OUT DVI IN (DVI-D/DVI-I) DVI OUT CAT5 DATA CABLE (UTP AWG24) GND DMX+ DMX Maximum 8 outputs Maximum 1536 channels per output CABLE B TUBE INTERCONNECTION Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 For CABLE C Color Brown White Black Blue Daisy-chained LED Tubes Max. 732 LED clusters (e.g. 12 x 1.5m tubes and 1 x 0.3m tube*) Total 2928 DMX512 channels (4 channels / pixel) Data Injector is needed when connection has more than 1 universe. This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. *Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal source. Please consult your local Traxon office for aid. End Cap Daisy-chained VMCs RJ45 Plug Starter Cable Max. units per chain: 8 Use DVI splitter for further VMC chain Pin 3: GND Pin 2: DMX+ See VMC specification for more information Pin 1: DMX Installation Guide 10/16 V1.0 16 of 26

FIG.14: Media Tube HO RGBW 1000W 6A Fuse Per Daisy Chain System Connection Example Meanwell Power Supply Unit 3x 48V DC 1kW Note: Markings on Wago terminal LED Engine 1000W 48V - single terminal blocks indicate polarity of fuse BACK PSU Rack for LED Engine 1000W 48V From Power/Data blocks. (Houses 3 x LED Engine 1000W 48V) source To fixture Connection point 3x 1kW Rackmount PSU Ring connectors can power up to 143.1m tubes (15.9m x 9) obscured by fuse block to fit M5 terminal on PSU Interconnection Example: POWER INJECTION WAGO terminal blocks LCE2 fx on 35mm wide DIN rail Quick Lock Power/Data Injector Cable Fuse: TU.AC.0600800 CABLE A 6A Slow blow x 2 Ø5 x 20mm AWG0~6 + Wago Terminal block set Injecting power for next daisy chain. DVI Source Ethernet Source CABLE C Power Distribution Blocks Power distribution block to Wago Terminal Block CABLE D AWG12~14 (1m max) + 48V DC GND DMX+ DMX WAGO Part no. 281-611/281-542 Quick Lock Starter Cable POWER: AWG17 DATA: AWG24 TUBES ARE DAISY CHAINED Interconnection cable Ethernet Switch 281-309 281-335 + 281-656 and 281-512/281-416 (Fuse block) 280-901 280-309 249-117 (End stopper) Video Micro Converter (VMC) DVI IN (DVI-D/DVI-I) DVI OUT DVI IN (DVI-D/DVI-I) DVI OUT CAT5 DATA CABLE (UTP AWG24) GND DMX+ DMX Maximum 8 outputs Maximum 1536 channels per output CABLE B TUBE INTERCONNECTION Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 For CABLE C Color Brown White Black Blue Daisy-chained LED Tubes Max. 636 LED clusters (e.g. 10 x 1.5m tubes and 1 x 0.9m tube*) Total 2544 DMX512 channels (4 channels / pixel) Data Injector is needed when connection has more than 1 universe. This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. *Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal source. Please consult your local Traxon office for aid. End Cap Daisy-chained VMCs RJ45 Plug Starter Cable Max. units per chain: 8 Use DVI splitter for further VMC chain Pin 3: GND Pin 2: DMX+ See VMC specification for more information Pin 1: DMX + Installation Guide 10/16 V1.0 17 of 26

FIG.15: Media Tube HO RGBW System 320W Outdoor Connection Example INDOOR OUTDOOR Installation engineer should use appropriate plugs for outdoor connection. 300mm AC In DMX In LED Engine 320W 48V POWER/DATA INJECTION Quick Lock Power/Data Injector Cable TU.AC.0600800 Injecting power for next daisy chain. RJ45 / Power to Quick Lock Injector Cable Kit TU.AC.0600400 TUBES ARE DAISY CHAINED Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 Color Brown White Black Blue Daisy-chained LED Tubes Max. 516 LED clusters (e.g. 8 x 1.5m tubes and 1 x 0.9m tubes*) Total 2064 DMX512 channels (4 channels / pixel) Data Injector is needed when connection has more than 1 universe. This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. *Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal source. Please consult your local Traxon office for aid. TUBE INTERCONNECTION Starter Cable End Cap Installation Guide 10/16 V1.0 18 of 26

FIG.16: Media Tube HO RGBW System 240W Outdoor Connection Example INDOOR OUTDOOR Installation engineer should use appropriate plugs for outdoor connection. 300mm AC In DMX In LED Engine 240W 48V PS.OB.0011002 POWER/DATA INJECTION Quick Lock Power/Data Injector Cable TU.AC.0600800 Injecting power for next daisy chain. RJ45 / Power to Quick Lock Injector Cable Kit TU.AC.0600400 TUBES ARE DAISY CHAINED Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 Color Brown White Black Blue Daisy-chained LED Tubes Max. 396 LED clusters (e.g. 6 x 1.5m tubes and 1 x 0.9m tubes*) Total 1584 DMX512 channels (4 channels / pixel) Data Injector is needed when connection has more than 1 universe. This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. *Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal source. Please consult your local Traxon office for aid. TUBE INTERCONNECTION Starter Cable End Cap Installation Guide 10/16 V1.0 19 of 26

FIG.17: Media Tube HO RGBW System 100W Outdoor Connection Example INDOOR OUTDOOR Installation engineer should use appropriate plugs for outdoor connection. 300mm AC In DMX In LED Engine 100W 48V PS.CU.0000008 POWER/DATA INJECTION Quick Lock Power/Data Injector Cable TU.AC.0600800 Injecting power for next daisy chain. RJ45 / Power to Quick Lock Injector Cable Kit TU.AC.0600400 TUBES ARE DAISY CHAINED Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 Color Brown White Black Blue Daisy-chained LED Tubes Max. 156 LED clusters (e.g. 2 x 1.5m tubes and 1 x 0.9m tube*) Total 624 DMX512 channels (4 channels / pixel) Data Injector is needed when connection has more than 1 universe. This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. *Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal source. Please consult your local Traxon office for aid. TUBE INTERCONNECTION Starter Cable End Cap Installation Guide 10/16 V1.0 20 of 26

8.1 FIG.18: WAGO TERMINAL BLOCK Wago Terminal Block Wiring (6A Fuse) Wago Terminal block set TU.AC.0000201 Note: Markings on Wago terminal blocks indicate polarity of fuse blocks. From Power Supply From Power/Data source To fixture Connection point obscured by fuse block Interconnection Example: WAGO terminal blocks on 35mm wide DIN rail Fuse: 6A Slow blow x 2 Ø5 x 20mm (TU.AC.9900000 100pcs) + + 48V DC + GND DMX+ DMX Starter Cable (20m) TU.AC.0000501 1939460000 (Weidmüller) TU.AC.0000300 Power Distribution Block DMX Data In RJ45 Plug 281-309 281-335 280-309 249-117 (End stopper) + WAGO Part no. 281-611/281-542 281-656 and 281-512/281-416 (Fuse block) 280-901 Signal 48V DMX Ground DMX+ Wire Size AWG 18 AWG 18 For Starter Cable Color Brown White Blue Black Pin 3: GND Pin 2: DMX+ Pin 1: DMX For interconnection from the power/data source to the fixture, a Weidmüller/Wago combination is used. Polarity of Wago fuse blocks are indicated on the top of the block. Always keep the polarity consistent, with the Live side leading to the fixture. The Indicator Lamp will trigger if there is no fuse or if the fuse has blown. CAUTION: Ensure the polarity of the Wago terminal blocks are correct (as shown in above diagram) to avoid causing damage to the fixture. Installation Guide 10/16 V1.0 21 of 26

FIG.19: Wago Terminal Block Wiring (7A Fuse) Note: Common the GND Wago terminal blocks using adjacant jumpers. From Power Supply Interconnection Example: WAGO terminal blocks on 35mm wide DIN rail Fuse: 7A Slow blow x 2 Ø5 x 20mm 281-402 Wago Terminal block set Power Distribution Blocks Power distribution block to Wago Terminal Block AWG12~14 (1m max) 48V DC GND DMX+ DMX Quick Lock Starter Cable POWER: AWG17 DATA: AWG24 RJ45 Plug Pin 3: GND Pin 2: DMX+ Pin 1: DMX 281-309 280-309 249-117 (End stopper) WAGO Part no. 281-611/281-542 281-611 280-901 Signal 48V DMX DMX+ Ground Wire Size AWG 17 AWG 17 Color Brown White Black Blue DMX Data In For interconnection from the power/data source to the fixture, a Weidmüller/Wago combination is used. Always keep the polarity consistent, with the Live side leading to the fixture. The Indicator Lamp will trigger if there is no fuse or if the fuse has blown. CAUTION: Ensure the polarity of the Wago terminal blocks are correct (as shown in above diagram) to avoid causing damage to the fixture. Installation Guide 10/16 V1.0 22 of 26

5. Care and Maintenance Traxon products are of superior design and quality and should be treated with care. The recommendations below will help fulfill any warranty obligations and gain good use and longevity from the products. Do not attempt or use the product(s) until you read and understand the installation instructions. Failure to adhere to these instructions could result in serious injury or property damage. Do not use product(s) if cables are damaged. Do not connect cables and connectors when wet or in wet area. Moisture on bare connectors can cause electric shock and damage to product(s). Do not use product(s) in extreme heat environment. Ensure there is sufficient airflow and use cool air circulation if required. Do not drop, knock, or shake product(s). Rough handling can damage the electronics and void the warranty. Do not use harsh chemicals, cleaning solvents, or strong detergents to clean products. Wipe with a damp cloth on housings and a dry cloth on electronics to remove dirt or dust. Do not attempt to service or repair the product(s) unless done by an authorized service personnel. Contact your local Traxon office or distributor for details. If the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance. Installation Guide 10/16 V1.0 23 of 26

6. Troubleshooting CAUTION: Ensure power supply is OFF when disconnecting / connecting cables. Problem Cause Possible Solutions Product does Incorrect power Check Mains Power NOT light up after connection Check power supply leads and wire installation connections Ensure output wires are connected with proper polarity Check Wago terminal block fuse. If Indicator Lamp is on, either the fuse is not present or it is blown. Check if LED Engine s secondary output is working as specified. Shadowing Light source covered Check for cables, wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected Flickering Incorrect power input/ Ensure the input voltage is correct Excess products Ensure the power supplies are not connected overloaded due to an excess of products connected If problems persist or the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance. Installation Guide 10/16 V1.0 24 of 26

7. TECHNICAL SPECIFICATION Media Tube HO RGBW Color Range: Light Source: Beam Angle: Power Input*: 16.7 million additive RGB colors; White CCT 6500K High intensity SMT RGB and White LEDs 110 (direct view); 175 (diffused) 48V DC Power Consumption (typ).: 4.6W / 8.6W / 12.5W / 16.6W / 20.9W Weight: 0.36kg / 0.58kg / 0.8kg / 1.02kg / 1.24kg (direct view) 0.4kg / 0.52kg / 0.84kg / 1.06kg / 1.28kg (diffused) Operating Temperature: 30 C to +60 C / 22 F to +140 F Storage Temperature: 40 C to +70 C / 40 F to +158 F *For use with TRAXON LED Engine 1000W 48V Indoor (PS.IE.0011100), LED Engine 320W 48V Outdoor, LED Engine 240W 48V Outdoor (PS.OB.0011002), LED Engine 100W 48V Outdoor (PS.CU.0000008) PSUs. As with all electronic devices, LED output degrades over time - a term called lumen depreciation. This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same. The rate of LED degradation is a complex function of many factors such as operating efficiency, duration of continuous operation, and operating conditions (e.g. ambient temperature). Because LEDs are semiconductor devices, their performances are subject to inherent variability commonly found in semiconductor industry. To improve consistency in performance across the same product, LED manufacturers sort LEDs into bins according to different preset parameters, such as forward driving voltage, illumination, etc. Whereas binning is a sorting function, it is not a correction process. Inherent variability in the manufacturing process always results in different binning distributions according to different production lots. Traxon uses automatically binned LEDs on its products, thereby minimizing output variations within the model range. 8. Warranty Statement Traxon Technologies warrants its Products against material or workmanship defects for a period of five (5) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual. Please refer for all warranty terms and conditions. Installation Guide 10/16 V1.0 25 of 26