Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Similar documents
Surface-mounting thermostats ATH series

Heating thermostat Series AMHs B Operating Instructions 11.06/

Panel-mounting Thermostats EM Series

Level Measurement silometer FMC 420, FMC 423

Process transmitter RMA422

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Panel-Mounted Thermostat

Capacitance Limit Detection nivotester FTC 420/421/422

TUC: Universal thermostat

Panel-mounting thermostats, type series EM

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Bimetal Temperature Switch

HS-509 VIBRATION TRIP MODULE

Series CT7N Bimetallic Overload Relays

263 Series LED Bargraph Indicator and Controllers

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Process Transmitter RMA 422

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Lt DELTA USA, Inc

CAMTO LTD. Arc detecting system DC/AC


Inductive sensor BI1.5-EG08K-Y1

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Electrical connection

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Datasheet - SRB301LC 24VAC/DC

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

APPLICATIONS. Automatic warehouse. Trasportation lines

RMA42. Technical Information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Photoelectrics Through-beam Type PA18C.T..., DC

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI10-M18-Y1X-H1141

Photoelectric Sensors E3F2

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

02/11/2015

LED Driver Compact fixed output

SCALE & WEIGHT DISPLAYS

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Capacitance Level Measurement Electronic insert FEC 12

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Preset counters, electronic

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Ordering details. Approval. Classification

10 SERIES. Light dependent relays A

LED Driver Compact fixed output

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

LED Driver Linear / area fixed output

Solid-State Digital Timer

Single Point Flow Monitor SW118 SW119

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

V 180 Series Photoelectric Switches

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LED control gear Compact fixed output

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Kuhnke Technical Data. Contact Details

Indication modules. LED-indication modules. Datasheet

DATA SHEET Panorama Rudder Indicator, TRI-2

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Multifunction devices

Pluggable interface relays CR-M Miniature relays

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Magnetic Stirrers Magnetic Stirr

Actuators IC 20, IC 40

SAUTER flexotron RDT405 Manual

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Capacitive sensor BCT5-S18-UP6X2T-H1151

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Coils for solenoid valves

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Absolute Rotary Encoder E6CP

LED Driver Compact fixed output

Linear encoders without bearings incremental System for linear motion feedback

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Transcription:

M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2TT, UK Phone: +44 12 79 63 55 33 Fax: +44 12 79 63 52 62 E-mail: sales@jumo.co.uk JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@jumousa.com Internet: www.jumousa.com Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 Bezel: 48 x 48mm, 74 x 32mm, 72 x 72mm Case size: 60mm dia. Brief description The electronic MICROSTAT-T is a temperature controller with ON/OFF switching action in different sizes for flush-panel mounting. Depending on the model, setpoint selection is either in analogue form with a pointer, by digital setpoint indication or against the process value display with changeover button. The process value is displayed continuously on a 3½-digit LCD display. Switching point and indication accuracy are ± 1.5% of span. The standard version includes adjustable switching differential and zero adjustment for optimum adaptation of the sensor accuracy to the particular operating point or range. Sensors for direct connection to the instrument include exchangeable resistance thermometers with silicon semiconductor sensors and platinum resistors to DIN / IEC 751, both with positive temperature coefficient and thermocouples to DIN 43 710 and IEC 584. Different supply voltage versions are available: 12 V DC (VDE approved), 11.4 27 V DC and 10 19 V AC (TZ 120) or 230 V AC (TZ 116). For operation on other supply voltages, separate mains modules are available for C-rail or wall mounting (panel). The standard transistor output is suitable for direct operation of electromechanical relays or electronic solid-state relays. Separate relay modules for C-rail or wall mounting are available. On request, the MICROSTAT-T is available with a factory-fitted electromechanical relay. Thanks to separate relay and supply modules, the MICROSTAT-T can be operated at ambient temperatures as high as +70 C. Data Sheet 60.8650 Page 1/6 Type 8650-66-48 Type 8650-67-32 Type designation 8650 Series 8650 as temperature controller with digital display 8650-65 Style 65 setpoint selection by rotary knob, analogue setpoint indication by pointer against scale, process value indication on LCD display (not with case size 74 x 32mm) 8650-66 Style 66 setpoint selection by rotary knob, setpoint indication on LCD process value indication on LCD 8650-67 Style 67 setpoint indication by rotary knob, setpoint indication on process value LCD display through keystroke (only for case size 74 x 32mm) O S w w 2000 t output OFF for x > w (process value above setpoint) output: OFF for x < w (process value below setpoint) for use with Pt100 resistance thermometers in 3-wire and 2-wire circuit for use with resistance thermometers with silicon semiconductor sensors in 2-wire circuit for use with thermocouples (please specify type when ordering) Case dimensions -48 bezel 48 x 48 mm -32 bezel 74 x 32 mm -72 bezel 72 x 72 mm -60 case size 60 mm dia. Type 8650-65-72 Type 8650-66-60

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.8650 Page 2/6 Extra Codes TZ 024 stop for setpoint limit Style 65: mechanical min. or max. limit with knob on front panel Styles 66 and 67: electronic max. limit with potentiometer on side of housing TZ 026 instrument centred for 68 x 68 mm panel cut-out (only with bezel size 72 x 72 mm) TZ 060 scale to customer specification TZ 101 built-in relay 5 A, 250 V AC (for series 8650 with VDE approval built-in relay 4 A, 250 V AC ) TZ 102 protective cover, transparent plastic (only for case size 48 x 48 mm) TZ 103 2 mounting brackets with threaded spindle TZ 104 setpoint adjusted with screwdriver (Styles 66 and 67 only) TZ 106 switching transistor (open collector) max. 30 V DC, 100 ma (only for series 8650 with VDE approval max. 24 V DC, 100 ma ) TZ 108 display format 0.1 C / digit TZ 112 LCD display with background lighting (only for Style 67) TZ 113 instrument without process value LCD display (only for Style 65) TZ 116 Supply 230 V AC, 50 Hz only for input w and w 2000 (no VDE approval) TZ 120 special versions (no VDE approval): Supply 11.4 V DC up to 27 V or 10 to 19 V AC relay 5 A, 250 V AC built in with TZ 101 switching transistor (open collector) max. 30 V DC, 100 ma with TZ 106 Accessories standard: 1 mounting frame, push-in fitting 1 Operating Instructions to special order: combination plate for MICROSTATS with 48 x 48 mm bezel, includes TZ 103 (see dimensions) Temperature probes (TF) Probe mountings (TA) Pockets (SH) see Data Sheet 60.8730 other versions to special order Note: Further thermocouples and resistance thermometers to DIN / IEC and special versions, see sectional catalogue Transducers for temperature and humidity 90. Separate mains and relay modules see Data Sheet 60.8884 (mains modules) see Data Sheet 60.8886 (relay modules) see Data Sheet 70.9010, 70.9020 (electronic solid-state relays) Ordering examples Type: 8650-65-48 Range: 0 to +100ºC Extra Code: TZ 101 Output: O Probe input: w 2000 Type: 8650-66-48 Range: 0 to +600ºC Output: O Probe input: t NiCr-Ni Technical data Input: Resistance thermometer in 3-wire circuit, Code w Ranges Style 65 Style 66 / 67 50 +060ºC 50 +200ºC 50 +400ºC 50 +600ºC On Style 65 scale as range. Lead compensation not required with 3-wire circuit. With resistance thermometers in 2-wire circuit, e.g. JUMO Type TF 75 or TF 76, the error without compensation resistor is +0.5 C max. When using longer leads, a compensation resistor must be fitted between terminals 1 and 3. R comp = R lead Input: Resistance thermometer with silicon semiconductor sensors in 2-wire circuit w 2000 Ranges Style 65 Style 66 / 67 30 +030ºC 10 +015ºC 50 +040ºC 50 +120ºC On Style 65 scale as range Lead compensation not required 50 +200ºC 50 +400ºC 50 +600ºC 20 +120ºC Input: thermocouple, Code t Ranges Fe-Con L NiCr-Ni K 50 +200ºC 50 +300ºC 50 +400ºC On Style 65 scale as range * with series 8650 not VDE approved. Lead compensation not required Temperature compensation standard Signal circuit monitoring 2-wire circuit The resistance thermometer and the probe cable are monitored for break and shortcircuit. The thermocouple and the probe cable are monitored for break. If one of these faults occurs, the transistor switch opens and the built-in or external relay is switched off. 3-wire circuit The resistance thermometer is monitored for break and short-circuit. If one of these faults occur, the transistor switch opens and the built-in or external relay is switched off. Fault indication With input w 2000, the faults short-circuit and break are indicated by different figures on the process value display. With input w, the faults short-circuit and break are indicated by the same figure. With input t, the fault break is indicated by overrange. General data Digital display Styles 65 and 66: 3½-digit, 6.4 mm (0.25") LCD display Style 67: 3½-digit, 12.7 mm (0.5") LCD display Indication accuracy ± 1.5% of span ± 1 digit 50 +0600ºC 50 +0900ºC 20 +1000ºC * Display format 1 C / digit, standard 0.1 C / digit, TZ 108 up to 199.9ºC

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.8650 Page 3/6 Linearity error w: 0.4 C max. on spans up to 400ºC 0.8 C max. on spans above 400ºC w 2000: 0.5 C max. t: Type L 1 C max. Type K 2 C max. Switching point accuracy ± 1.5% of span Switching differential inputs w and w 2000: x sd = 0.5 to 15 C on controls spans 300ºC and below, adjustable from the side x sd = 1 to 30 C on control spans 300ºC and above, adjustable from the side input t: x sd = 1.5 to 33 C with Type L x sd = 3,5 to 38 C with Type K switch-off at process value x = setpoint w switch on at process value x = setpoint w differential x sd with output action O switch on at process value x = setpoint w + differential x sd with output action S Output standard: switching transistor for use with relay modules to Data Sheets 60.8886, 70.9010 and 70.9020 Extra Code TZ 101 built-in relay 1250W, 5 A at 250 V AC, resistive load (VDE-approved 1000W, 4 A 250 V AC, resistive load) approx. 300 000 operations at rated load (VDE-approved, Class II, 100 000 operations) approx. 1 000 000 operations at 2 A, 250 V AC, resistive load Extra Code TZ 106 switching transistor (open collector) 30 V DC, 100mA max. (VDE-approved, 24 V DC, 100mA max.) When using relays or contactors of other manufacturers, a protective diode must be connected in parallel with the coil winding, e.g. 1N4148 or similar. special version (TZ 120) built-in relay 1250W, 5 A at 250 V 50 Hz, resistive load approx. 300 000 operations at rated load approx. 1 000 000 operations at 2 A, 250 V 50 Hz, resistive load Status indication a yellow LED on the front panel indicates: Transistor switch closed or Relay energised Supply 11.4 to 27 V DC 10 to 19 V AC 230 V AC 50 Hz 12 V DC (VDE-approved) The electronics is protected against incorrect polarity of the supply. Power consumption 250 mw max. at 12 V supply (without external relay) 500 mw max. at 12 V supply and TZ 101 special version (TZ 120): 700 mw max. at 24 V supply (without external relay) 1.5 W max. at 24 V supply (relay built in) 1.6 VA max. at 230 V AC supply (relay built in) Electrical connection faston connectors to DIN 46 244 / A 6.3 x 0.8 mm Permitted ambient temperature 0 to 70ºC special version TZ 120: 0 60ºC at 24 V supply 0 50ºC at 24 V supply and built-in relay (TZ 101) 0 50ºC at 230 V AC supply and built-in relay (TZ 101) Permitted storage and transport temperature -30 80ºC Ambient temperature error 0.5 C max. per 10 C with code w 0.5 C max. per 10 C with code w 2000 0.5 % max. per 10 C with code t Block diagram Electromagnetic compatibility EN 61 326 Noise immunity: general requirements Interference emission: Class B Zero adjustment The zero adjustment on the side permits optimum adjustment of the switching point, display and probe accuracy to the corresponding operating point or range of the user. This adjustment requires a reference temperature at the temperature probe. Construction Case with bezel polycarbonate, black Style 65 black scale, white lettering red setpoint pointer transparent front black knob Style 66 black front panel, white lettering transparent front black knob Style 67 black front panel, white lettering red setpoint key transparent front black knob Protection (Styles 65/66/67) to DIN 40 050, front IP30 rear IP00 front IP50 when using a seal between bezel and panel. Operating position unrestricted Weight approx. 0.2 kg Operation, Style 65 The input signal (1) is linearised and amplified in the input stage (2) and passed to the comparator (5) as process value x. In the comparator, the difference is formed between the process value x and the setpoint w selected on the setpoint unit (6), resulting in the control deviation x w. At the same time, the process value signal passes through an A/D converter (4) and is indicated on a 3½-digit LCD display. The contact action O = opening or S = closing is selected by internal links (7). The difference signal produced during a control deviation operates a trigger stage (9). The switching differential x sd of the trigger stage is set with the potentiometer (10).

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.8650 Page 4/6 The unit is fitted as standard with a monitoring circuit (3) for probe and cable break or short-circuit. The result of the monitoring is linked in the logic stage (11) to the output signal of the trigger stage. In the standard version, the switching transistor (13) operates an external relay (17). The extra Codes TZ 101 relay 5 A, 250 V AC (VDE-approved 4 A 250 V AC) or TZ 106 switching transistor, open collector 100 ma max. 30 V DC (VDE-approved 24 V DC) are available as alternatives. The LED (12) lights up for relay energised. The supply voltage required for operating the various circuits is produced in the external mains module (18) and stabilised internally by the voltage regulator (15). Operation, Style 66 as for Style 65, but the setpoint signal is indicated on a second LCD display (20) through an A/D converter (19). Operation, Style 67 as for Style 65, but setpoint indication by keystroke on the display unit (4) and (8). Dimensions

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.8650 Page 5/6 Combinations of 2 or 4 MICROSTATS, bezel 48 x 48 mm Extra Code TZ 102 Electrical connection Connection for Control action Terminals Relay output as on label O x > x k1 20 (P) common S x < x k1 21 (S) n.o. (make) 22 (Ö) n.c. (break) Logic control output O x > x k1 20 + for relay module 8840-6 S x < x k1 21 - Switch output open collector O x > x k1 20 + S x < x k1 21 - Supply TZ 120 AC 10 19 V 100 ~ TZ 116 AC 230 V, 50 Hz 200 ~ TZ 120 DC 11.4-27 V 100 + DC 12 V 200 Input Resistance thermometer in 2-wire circuit Resistance thermometer in 3-wire circuit Code Semiconductor probe KTY in 2-wire circuit w 2000 w 1 2 R L = R comp 3 1 2 3 1 2 Thermocouple t 1 blue or green 2 + red Rear view of controller 48 x 48 Ø 60 / 72 x 72 74 x 32

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.8650 Page 6/6 standard Controller output switching transistor for use with relays to Data Sheet 60.8884, Data Sheet 70.9010, Data Sheet 70.9020 Controller output TZ 101 Controller output switching transistor open collector TZ 106 Supply Mains module 8840-1. Mains module 8840-2. Mains module 8840-3. Combination mains and relay module 8840-2. / 8846-1. External relay or contactor (not from JUMO) Combination mains and relay module 8840-1. / 8846-1. Resistance thermometer in 2-wire circuit Resistance thermometer in 3-wire circuit Thermocouple