Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Similar documents
1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

High-Value 100 Series (Outdoor)

Multiple Band Outdoor Block Up- and Downconverters

SYNTHESIZED COMMUNICATION CONVERTERS

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

SATCOM FIBER OPTIC PRODUCTS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

High Performance Outdoor Test Translators

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

1/3 RACK-MOUNTED BLOCK CONVERTERS

MULTIBAND 1/3 RACK-MOUNTED

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

C-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems

X-Band Redundant LNB Systems

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Redundant LNB Systems

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

Redundant LNB Systems

Satellite Up- and Downconverter Indoor / Outdoor

Redundant LNB Systems

Modular Block Converter Systems

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Redundant LNB Systems

Indoor Dual Converter

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Synthesized Block Up- and Downconverter Indoor / Outdoor

Satellite Up- and Downconverter

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

Synthesized Block Up- and Downconverter

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Product Catalogue January 2018

L-Band Block Up- and Downconverter Indoor / Outdoor

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Inmarsat Downconverter Narrowband Downconverter

Instruction Manual Model Block Up/Downconverter

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Analog & Digital RF-Solutions

ModuMAX SSPA Systems C, X, and Ku-Bands

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Instruction Manual Model # Block Upconverter

DVO700 P FIBRE OPTIC TRANSMITTER

2W SDARS ECHO Repeater

Satellite Up- and Downconverter

Instruction Manual Model BlockUpconverter

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

Typical applications:

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Wideband LNB: 2.4 GHz

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Broadband Quadplexer Combiner

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

The Art of Engineering

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

16W Ku-band Matchbox BUC

L-Band Block Upconverter

Features. Gain Variation Over Temperature db/ C

HMC-C078. SDLVAs. Features. Typical Applications. General Description. Functional Diagram

TELEDYNE Paradise Datacom A Teledyne Technologies Company

v SUCCESSIVE DETECTION LOG VIDEO AMPLIFIER (SDLVA) 1-20 GHz Features Parameter Conditions Typ. Units Input Frequency Range 1-20 GHz

The Hmc869LC5 is ideal for: Point-to-Point and Point-to-Multi-Point Radio. Parameter Min. Typ. Max. Units

Instruction Manual Model

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Noise Detector ND-1 Operating Manual

Instruction Manual Model

Table of Contents. Quick Reference. Detailed Data Sheets. General Information. Questions & Answers. Technical Article. Technical Application MIXE MIXE

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Parameter Min. Typ. Max. Min. Typ. Max. Units

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

Features. = +25 C, IF= 100 MHz, LO= +13 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

6 GHz to 26 GHz, GaAs MMIC Fundamental Mixer HMC773A

Modems, Receivers and RF/IF/Baseband Processing Systems and Components. ASDM-100 FMOD-70, PMOD-70, FDMOD-70 and PDMOD-70 MFUM-70 WFMD-70

NS-3 RF Noise Source Operation Manual

OBSOLETE HMC908LC5 MIXERS - I/Q MIXERS, IRMS & RECEIVERS - SMT. GaAs MMIC I/Q DOWNCONVERTER 9-12 GHz. Typical Applications. Functional Diagram

Prisma Optical Networks Ancillary Modules

Transcription:

R Back to Amplifier Systems 1:1, Dual 1:1 and 1:2 Redundant Low-Noise The 1:1, dual 1:1 and 1:2 redundant lownoise amplifier (LNA) systems are designed to ensure continuous operation without disruption of signal transmission. A fault condition in the on-line LNA, or an operator generated command, will switch the standby LNA to the on-line position and remove the on-line LNA from the signal path. The redundant LNA system consists of an outdoor amplifier/switch assembly which mounts at the antenna hub, rack mounted indoor local control unit and interconnection control cable. FEATURES Low amplifier noise temperature Fault tolerant design Fully redundant, hot swappable power supplies Remote control via RS485 or RS422 user selectable Automatic/manual control from both local and remote mode Remote status Off-line input/output access Amplifier current fault detection Weather resistant amplifier/switch plate assembly Time-stamped alarm history Front panel LNA bias display 1:1, DUAL 1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS 1:1 1:2 DUAL 1:1 OPTIONS Remote RS232 or contact closure Transmit reject filter Internal noise source Input/output signal monitors Higher gain Increased output power Remote control unit Specifications Standard Waveguide Flanges Controller Rear Panel Block Diagrams 1:1 and 1:2 Redundant LNA Systems Outline Drawings 1:1 and 1:2 Ku-Band 1:1 and 1:2 C-Band Options 100 Davids Drive Hauppauge NY 11788 631-436-7400 Fax: 631-436-7431 www.miteq.com

The 1:1, dual 1:1 and 1:2 redundant lownoise amplifier (LNA) systems are designed to ensure continuous operation without disruption of signal transmission. A fault condition in the on-line LNA, or an operator generated command, will switch the standby LNA to the on-line position and remove the on-line LNA from the signal path. The redundant LNA system consists of an outdoor amplifier/switch assembly which mounts at the antenna hub, rack mounted indoor local control unit and interconnection control cable. 1:1, DUAL 1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS 1:1 1:2 FEATURES Low amplifier noise temperature Fault tolerant design Fully redundant, hot swappable power supplies Remote control via RS485 or RS422 user selectable Automatic/manual control from both local and remote mode Remote status Off-line input/output access Amplifier current fault detection Weather resistant amplifier/switch plate assembly Time-stamped alarm history Front panel LNA bias display DUAL 1:1 OPTIONS Remote RS232 or contact closure Transmit reject filter Internal noise source Input/output signal monitors Higher gain Increased output power Remote control unit

SPECIFICATIONS Available Noise Temperature Interface Frequency (GHz) Band Abbreviation At +25 C (Maximum) Input/Output 1.5 1.6 150160 33, 40, 60 SMA/SMA 2.2 2.3 220230 33, 40, 60 SMA/SMA 3.4 4.2 340420 30, 35, 40, 50, 60 CPR-229G/N 3.4 4.8 340480 30, 35, 40, 50, 60 CPR-229G/N 3.62 4.205 362420 30, 35, 40, 50, 60 CPR-229G/N 4.5 4.8 450480 30, 35, 40, 50, 60 CPR-229G/N 7.1 8.4 710840 50*, 55, 60, 65 CPR-112G/SMA 7.25 7.75 725775 45, 50, 55, 60, 65 CPR-112G/SMA 8.0 8.4 800840 50*, 55, 60, 65 CPR-112G/SMA 10.7 12.75 107128 70, 80, 90, 100 WR-75/SMA 10.95 12.75 109128 65, 70, 80, 90, 100 WR-75/SMA 10.95 11.70 109117 65, 70, 80, 90, 100 WR-75/SMA 11.70 12.75 117128 65, 70, 80, 90, 100 WR-75/SMA 17.7 21.2 177212 120*, 140, 160, 200 WR-42/SMA 17.7 22.0 177220 130*, 140, 160, 200 WR-42/SMA 18.7 20.3 187203 120*, 140, 160, 200 WR-42/SMA 20.2 21.2 202212 120*, 140, 160, 200 WR-42/SMA * References 14 db minimum input return loss specification. Low-noise amplifier system model numbers: Model number: LN (controller)-(frequency band abbreviation)-(amplifier noise temperature) Controller code: 1 = 1:1 Controller 2 = 1:2 Controller 3 = Dual 1:1 Controller Please note that each low-noise amplifier system is supplied with: 1 Redundant amplifier/switch assembly 1 Local control and monitoring unit 1 100 foot interconnection control cable (other lengths optional) Example: Example: 1:1 system, 10.95 12.75 GHz with 65 K amplifier noise temperature: LN1-109128-65 1:2 system, 3.4 4.2 GHz with 30 K amplifier noise temperature: LN2-340420-30 Assembly enclosure option: To substitute a weather resistant enclosure for the standard weather resistant plate assembly add -W to end of part number. The weather resistant enclosure is recommended for mounting in a nonsheltered environment with direct rainfall. Example: 1:2 system, 3.4 4.2 GHz with 30 K amplifier noise temperature in a weather resistant enclosure: LN2-340420-30-W SPECIFICATIONS Gain... 50 db minimum, 52 db typical (higher gain optional) Gain flatness... 0.4 db/40 MHz, 1.0 db peak-to-peak/ bands up to 500 MHz, 1.5 db peak-to-peak/ bands up to 800 MHz, 2.0 db peak-to-peak/ bands greater than 800 MHz Gain slope... 0.2 db/10 MHz maximum

SPECIFICATIONS (CONT.) Gain stability... ±0.2 db/24 hours (constant temperature), 5 db maximum/-40 to +60 C (higher stability optional) Power output (1 db compression)... +10 dbm minimum (higher output power optional) AM/PM conversion... 0.5 /db maximum to 0 dbm output Group delay (±18 MHz) Linear... 0.02 ns/mhz maximum Parabolic... 0.001 ns/mhz 2 maximum Ripple... 0.1 ns peak-to-peak maximum Spurious outputs... Below thermal noise Isolation... 50 db minimum Input return loss... 19 db minimum, *14 db minimum (refer to table) Output return loss... 20 db minimum Input/output impedance... 50 ohms Switchover time... 100 ms maximum Nondamage input power... +10 dbm maximum Transmit desensitivity threshold C-band... -20 dbm maximum (-30 dbm with Option 11) X-band... -50 dbm maximum (-60 dbm with Option 11) Ku-band... -20 dbm maximum (-30 dbm with Option 11) Ka-band... -50 dbm maximum (-60 dbm with Option 11) LOCAL CONTROL UNIT PRIMARY POWER REQUIREMENTS Voltage... 90 250 VAC Frequency... 47 63 Hz Power consumption... 20 W typical, 50 W peak during switchover SUMMARY ALARM Contact closure/open for DC voltage and/or amplifier alarm Status alarm readout on remote control bus PHYSICAL AC input connectors... IEC-320 Summary alarm interface mating connector... DEM-9P Remote interface connector... DEM-9S for RS485 and RS422, DB-25P for RS232, DB-37S for contact closure Switch/amplifier weight (does not apply to weather resistant housing option) 1:1 units... Below 10 GHz 15 lbs, above 10 GHz 10 lbs nominal 1:2 units... Below 10 GHz 25 lbs, above 10 GHz 20 lbs nominal ENVIRONMENTAL Operating Ambient temperature (Controller)... 0 to 50 C Ambient temperature (Amplifier assembly)... -40 to +60 C (other ranges available, consult factory) Atmospheric pressure... Up to 10,000 feet Nonoperating Temperature... -50 to 70 C Atmospheric pressure... Up to 40,000 feet Shock and Vibration... Normal handling by commercial carriers

STANDARD WAVEGUIDE FLANGES 3.88 2.916 2.290 2.50 1.372 1.122 1.771 2.75 1.145.550 1.050 1.550 2.100 1.75.747.497.328.640.953 1.281.550 1.620 2.690 3.240 #1/4-20 x 0.31 DP (TYP. 10 PLACES).578.953 1.328 1.906 WR-112 CPR-G FLANGE #8-32 x 0.25 DP (TYP. 8 PLACES) WR-229 CPR-G FLANGE.375 1.500 SQ..750.561 1.122.170.875 SQ..420.335.670.280.750 SQ..265.530 #6-32 x 0.25 DP (TYP. 4 PLACES).520 1.040 #4-40 x 0.25 DP (TYP. 4 PLACES).320.640.140 # 4-40 x 0.25 DP (TYP. 4 PLACES).250.500 WR-75 GROOVED FLANGE WR-42 GROOVED FLANGE WR-28 GROOVED FLANGE NOTE: FLANGES NOT DRAWN TO SIZE REAR PANEL VIEW 1:1 AND 1:2 DUAL 1:1 Ground lug Power supply A AC voltage input/switch Power supply B AC voltage input/switch Summary alarm connector Remote interface connectors LNA 1 interface LNA 2 interface Amplifier assembly interface connectors

1:1 REDUNDANT LNA SYSTEM BLOCK DIAGRAM OPTION 3 OPTION 1 OPTION 2 A1 TRANSMIT REJECT -40 dbc A2-20 dbc 1:2 REDUNDANT LNA SYSTEM BLOCK DIAGRAM A1 OPTION 3 OPTION 1 OPTION 2 1 TRANSMIT REJECT 1-40 dbc A3-20 dbc OPTION 3 OPTION 1 WAVE- GUIDE W2 OPTION 2 2 TRANSMIT REJECT WAVE- GUIDE W1 2-40 dbc A2-20 dbc Typical system noise temperature calculation: 1:1 Redundant System: T system = T LNA + T SWITCH + T OPTION 3 + T OPTION 1 1:2 Redundant LNA System: input 1: LNA 1 on-line signal path T system = T LNA + T SWITCH + T OPTION 3 + T OPTION 1 input 1: LNA 3 on-line signal path (LNA 1 standby) T system = T LNA + 2 * T SWITCH + T W2 + T OPTION 3 + T OPTION 1 input 2: LNA 2 on-line signal path T system = T LNA + T W1 + T SWITCH + T OPTION 3 + T OPTION 1 input 1: LNA 3 on-line signal path (LNA 2 standby) T system = T LNA + 2 * T SWITCH + T W1 + T W2 + T OPTION 3 + T OPTION 1 Typical Noise Temperature in Kelvin at 23 C 3.4 4.2 & Band (GHz) 0 0.95 0.95 2 3.62 4.205 4.5 4.8 7.2 7.8 10.7 12.75 17.7 22.0 27.5 33 (coaxial) WR-229 WR-229 WR-112 WR-75 WR-42 WR-28 T SWITCH 7.0 13.5 1.5 1.5 3 5 12 20 T W1 N/A N/A 1.5 1.5 4 4 7 10 T W2 14 14 1.5 1.5 9 9 11 15 T OPTION 1 25 25 0.5 0.5 2 2 3 4 T OPTION 3 N/A N/A 3.0 7.5 28 15 N/A N/A

1:1 Ku-BAND AMPLIFIER ASSEMBLY OUTLINE DRAWING MS3112R14-18P (MS3116F14-18S MATING CONNECTOR SUPPLIED).50 10.00 [254.0] 9.00 [228.6].257 DIA. THRU (TYP. 4 PLACES) J1 WR-75 WAVEGUIDE.50 6.25 [158.75] 7.50 [190.5] 2.00 [50.8] 3.75 [95.25] 5.00 [127.0] TYPE 'SMA' FEMALE CONNECTOR WITH TERMINATION J3 LOCAL INTEACE J2 J5 J4 MONITOR 16.88 [428.75] 9.000 [228.6] 8.000 [203.2] MITEQ INC. HAUPPAUGE, NY 1:1 REDUNDANT LNA UNIT MODEL LN1- TRANSMIT REJECT (OPT. 3 ONLY) TEST INJECT COUPLER (OPT. 1 ONLY) 4.500 [114.3] 1.25 [31.75] MONITOR (OPT. 2 ONLY).75 [19.05] 7.000 [177.8] 6.35 [161.29] 8.005 [203.33] 3.500 [88.9].25 [6.35} 1:2 Ku-BAND AMPLIFIER ASSEMBLY OUTLINE DRAWING 6.09 [154.79] 7.32 [185.80] 1.19 [30.30] 1.62 [41.13] 2.81 [71.42] 3.04 [77.14] J5 LOCAL INTEACE J2 1 J4 2 J2 1 J4 2 14.54 [369.31] MAX. 5.0 5.0 8.00 [203.2] 9.00 [228.6] 10.00 [254.0] 9.00 [228.6] 1:2 REDUNDANT LNA UNIT MODEL LN2 J1 1 J3 2 257 DIA. THRU (TYP. 4 PLACES) TEST INJECT COUPLER (OPT. 1 ONLY) TRANSMIT REJECT (OPT. 3 ONLY) J1 1 WR-75 WAVEGUIDE MITEQ P/N 125501-9 4.50 [114.3] 2.49 [63.25].64 [16.21] 1.25 [31.75] 3.28 [83.33] MS3112R16-26P (MS3116F16-26S MATING CONNECTOR SUPPLIED) MITEQ INC. HAUPPAUGE, NY MONITOR (OPT. 2 ONLY).75 [19.05] 9.30 [236.2] J3 2 WR-75 WAVEGUIDE 1.75 [44.45] 3.50 [88.9] 8.00 [203.3].25 [6.35] NOTE: DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS

1:1 C-BAND AMPLIFIER ASSEMBLY OUTLINE DRAWING 1.31 [33.27].31 [7.87] 10.44 [265.18].50 MITEQ P/N 131644 12.00 [304.80] 11.00 [279.40].50 [12.70] 4.43 [112.52] MS3112R14-18P (MS3116F14-18S MATING CONNECTOR SUPPLIED) 8.50 [219.9] 6.75 [171.45] 5.50 [139.7] 4.25 [107.95] 3.00 [76.2] MONITOR (OPT. 2 ONLY) J3 LOCAL INTEACE J2 J5 J5 MONITOR 12.00 [304.8] 11.00 [279.4].257 DIA. THRU (TYP. 4 MOUNTING HOLES).78 [19.81] 1.25 [31.75] 18.1 [459.74] TRANSMIT REJECT (OPT. 3 ONLY) WR-229 TEST INJECT COUPLER (OPT. 1 ONLY) 6.00 [152.4] 1:2 C-BAND AMPLIFIER ASSEMBLY OUTLINE DRAWING MS3112R16-26P (MS3116F16-26S MATING CONNECTOR SUPPLIED).257 DIA. THRU (TYP. 6 MOUNTING HOLES) 8.75 [222.25] 10.00 [254.00] 1.31 [33.27] 3.75 [95.25] 5.00 [127.0] 6.25 [158.75] 7.50 [190.5] J3 J2 LOCAL INTEACE 1 J$ 2 J^ 1 MONITOR 2.25 [57.15].500 [12.70].500 [12.70] 12.00 [304.80] 11.00 [279.40] 16.00 [406.40] 15.00 [381.00] 7.50 [190.50] 1:2 REDUNDANT LNA UNIT MODEL LN2- MITEQ P/N 130892 17.55 [445.77] 5.00 [127.0] 4.45 [113.03] 6.00 [152.40] 5.00 [127.0] J7 2 MONITOR MONITOR (OPT. 2 ONLY) 10.50 [266.7].78 [ 19.81] 14.75 [374.65] 7.52 [191.01] TRANSMIT REJECT (OPT. 3 ONLY).31 [7.87] WR-229 TEST INJECT COUPLER (OPT. 1 ONLY) NOTE: DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS

1:1, DUAL 1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS OPTIONS Note: System noise temperature will increase and return loss will degrade for any additional component located before the amplifier. This applies to Options 1 and 3. 1. Test input inject couplers. Below 3.4 GHz, coaxial coupler 40 db nominal coupling level. Above 3.4 GHz, crossguide coupler 40 db nominal coupling level. 2. Output test coupler. 20 db nominal coupling level. 3. Transmit reject filter. Receive Band Receive Band Transmit Band Transmit Band Frequency (GHz) Insertion Loss Frequency (GHz) Rejection 3.4 4.2.04 db 5.825 6.725 60 db 3.62 4.205 0.04 db 5.825 6.425 55 db 4.5 4.8.15 db 6.70 7.05 55 db 7.25 7.75 0.5 db 7.9 8.4 64 db 10.7 12.75.15 db 13.75 14.5 60 db 10.95 12.75 0.1 db 14.0 14.5 70 db 17.7 21.2 0.25 db 27.0 31.0 70 db 4. Noise source. 15 db ENR nominal. Local and remote control provided. 6-(x). Local control unit to amplifier/switch assembly cable length, where (x) is the length of the cable in feet. Available from 10 to 400 feet in 10 foot increments. 100 foot cable supplied as standard. 11. Increased gain. 60 db minimum gain. 12. Increased output power. +20 dbm output power at 1 db compression. 13. Increased gain stability. 3 db peak-to-peak maximum/-40 to +60 C. 17. Remote control. B. RS422/485 (supplied as standard). C. RS232. D. Contact closure. 22. Dedicated remote control panel. Provides remote control over a dedicated RS422/485 bus. Option 17B (RS422/485 remote bus) must be ordered. Notes: Missing option numbers are not applicable to this product. For literature describing local control and remote control (bus protocols), refer to MITEQ s Technical Note 25T042. D-235B 100 Davids Drive, Hauppauge, NY 11788 TEL.: (631) 436-7400 FAX: (631) 436-7431/436-7430 www.miteq.com