OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Similar documents
OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Aerial Cable Installation Best Practices

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Aerial Installation Guidelines for Fiber Optic Cable

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Dry-Core ADSS Cable Placement

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

Installation of Solo ADSS All-Dielectric Self-Supporting Fiber Optic Cables

Aerial Fiber Cable Placing Methods

SOLO ADSS Short-Span Cables, Fibers

Underground Installation of Optical Fiber Cable by Pulling

FIBER OPTIC CABLE PULLING

Installation of Optical Fiber

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

SPECIFICATION. Optical Fiber Cable

Water blocking tape. Locator ridge HPA-0486

ENGINEER S REPORT. of the SAFETY OF MAW COMMUNICATIONS FIBER OPTIC CABLE INSTALLATION

Limited Tension Formed Wire Dead End for ADSS Cable

FusionLink Central Tube Ribbon Preparation & handling procedure

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

The FiberMark1 offers an ideal solution for

Selecting the correct cable type for Outside Plant Application

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

Public Works Division Lighting District Fiber Optic Specifications April 2009

Gel-sealed in-line fiber optic closure

HCS - HES Cabling Systems

SLiC Fiber Aerial Closure System

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Placing Fiber Optic Cable in Underground Plant

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

TECHNICAL SPECIFICATION

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Laying of cables and lines in electrical installations and data networks

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

Section Communications Optical Fiber Backbone Cabling

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

INSTALLATION INSTRUCTIONS

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

UNOLS Wire Pool Database. Presented by Rick Trask Woods Hole Oceanographic Institution

Cable Installation Tips

FOSC 450 C6 and D6 Closures

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013

Cable installation guidelines

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FIBER OPTICS. UNDERGROUND FIBER OPTICS IX Page 1 of 18. Underground Electric Distribution Standards I. ENGINEERING

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

A Comparison of Dry Versus Gel Filled Optical Cables

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

Number of Fiber 6 Core 12 Core. Part Number

Cable Installation Tips

SECTION FIBER OPTIC STATION CABLES

Copyright Black Box Corporation. All rights reserved.

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Installing fiber optic cables

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Channel Cable Tray - Accessories

SPECIFICATION FOR THE ERECTION OF SELF-SUPPORTING OPTICAL FIBRE CABLE ON TRACTION MASTS

Installation Guide OvalSox TM Cable

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Purchase Now ANSI/ICEA S

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Underground Installation of Optic Fiber Cable Placing

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

STRUCTURED CABLE SYSTEM (SCS)

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

WALKING A TIGHT ROPE

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

Optical Distribution Box 300 Installation Guide. Version : R0.0

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

DIAS power supply and DIC 221 fibre optic cable coupling module

Starling Tab-Tension 2 Series

Cable Broadband Premises Installation and Service

SUPERFLEX CABLE. What is Superflex Cable? Why make cable this way? Where Superflex Cable originated

PROFIBUS Assembling Guideline Version 1.14 May 2015 Order No: 8.022

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Service Call: Fiber Optic Installation and Repair

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

Cable and Power Management Open-Frame Rack Cable Managers

Check what you have received against the component checklist and hardware above.

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

Transcription:

Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Round Messenger (ADSS) A round messenger fiber optic cable is designed for use in aerial installations that do not require a messenger for support. This cable is all dielectric and self supporting (ADSS). - Maintain the minimum bending radius (MBR). The minimum bending radius for Optical Cable Corporation s round messenger cables are as follows: o Short Term Tensile Loading 20XOD (fiber optic cable outside diameter) o Long Term Tensile Loading 10XOD (fiber optic cable outside diameter) Hardware A round messenger cable has several advantages. Installation material cost may be reduced by eliminating the need to purchase a separate messenger wire and lashing wire or to purchase a figure 8 cable. The labor cost can be greatly reduced in that there is only one installation job installing the round messenger cable as compared to installing a messenger wire and an aerial cable. Typically, the overall cost of the installation may be reduced by as much as 40 %. Dead Ends Dead ends maintain the tension in the cable. A typical dead end for a round messenger cable consists of spirally formed high strength steel wires which are installed over reinforcing rods placed around the cable. Dead End Grip Reinforcing Rods Installation Precautions Some precautions to be considered when installing round messenger cables include the following: - Installing cables installed near high voltage greater than 12kV is not recommended - Follow the National Electrical Safety Code (NESC) for all installations - Maintain proper clearances between the fiber optic cable and the power cables - Make allowances for sag - The cable should be kept on one side of the poles (avoid zigzagging from one side of the pole to the other) - Avoid twisting of the cable Tangent Support Clamps Tangent support clamps are used to support the round messenger cable were limited tension is applied to the cable. There are various types of tangent support clamps. Please contact the tangent support clamp manufacturer for span lengths, sizes, and angle departure. Fiber Optic Cable Page 2 of 5

Tangent Support Slack Storage Slack storage for round messenger cable can be located aerially or by running the excess cable down a pole and into a hand hole large enough to support the minimum bending radius of the cable. If the slack cable is going to be stored aerially, slack cable storage brackets are available. The brackets should be sized to insure the minimum bending radius of the cable is achieved. Pole Dead End Grip Slack Storage Fiber Optic Cable Cable Support Bracket Installation There are two basic types of installation techniques; moving reel method and stationary reel method. Moving Reel Method The moving reel method is best used when there are no obstacles between the cable reel and aerial placement of the cable. Also, a clear path along side the poles is needed for the reel trailer and trucks. This method of installation is typically less costly than other methods due to the fact that there is less hardware involved during the installation. The cable is payed off a moving reel trailer, or truck, while driving along the route of the poles. At each pole location, the reel must be kept at least 50 feet from the pole while the cable is lifted into place on the pole. J Hooks or tangent supports without the inserts are used to temporarily hold the cable in place on each pole until a pole is reached where dead end hardware is necessary. Once a dead end pole is reached, the cable is properly tensioned and the cable is secured at the pole with dead end hardware. Once the cable has been secured with the dead end hardware, the cable between the dead ends should be securely fastened to the poles by removing the J Hooks and attaching the proper tangent support hardware. If tangent support hardware without the inserts were used for temporary placement, then the center inserts should be installed in order to secure the cable. Page 3 of 5

Tangent Support Moving Reel Method Stationary Reel Method The stationary reel method is best used when there are obstacles along the path as to not to allow a reel trailer and truck to drive through. This method is generally more costly than other methods and may require more time to install the cable. In the stationary reel method, the Round Messenger cable is pulled into place using rope and stringing blocks placed at each pole along the route. The radius of the stringing blocks must meet the minimum bending radius (under installation load or short term load) of the cable. Some tangent support manufactures allow cables to be pulled through the tangent support clamps by removing the inserts. These tangent support clamps may be used up to certain line angle changes. Please contact the tangent support manufacturer. It is highly recommended that stinging blocks that meet the minimum short term bending radius of the cable being installed be used on all poles where the line angle changes are greater 10 o. During the pull of the cable onto the stringing blocks, Kellems pulling grips and a break-away swivel that is rated at the proper pulling tension of the cable should be used to attach the pulling rope to the cable. Please refer to the Installation General Guidelines of the Optical Cable Corporation Installation Guide. Once the cable has been pulled into place, the Round Messenger cable is tensioned and terminated with dead end hardware and attached to the pole at each dead end location along the route. Once the cable has been secured with the dead end hardware, the cable between the dead ends should be securely fastened to the poles by removing the cable from the stringing blocks and attaching the proper tangent support hardware. If tangent support hardware without the inserts was used for temporary placement, then the center inserts should be installed in order to secure the cable. Page 4 of 5

Stringing Blocks Pulling Rope Winch Tangent Support Kellems Grip & Swivel Pulling Eye Direction of Pull Fiber Optic Cable Stationary Reel Stationary Reel Method Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s Installation Guide Page 5 of 5