HS-509 VIBRATION TRIP MODULE

Similar documents
SI-510 DUAL TRIP AMPLIFIER

263 Series LED Bargraph Indicator and Controllers

Model IQ4-PC User Manual Revision Date:

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

SCALE & WEIGHT DISPLAYS

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

21 Channel Light Show PWM LED Controller with Remote Control

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

1900/25 Vibration Monitor

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Tech Support: Customer Service: General Tech Questions: Tech Docs:

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

LARGE DIGITAL LED REAL TIME CLOCKS

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

RF Wireless Receiver (Model S4PU-DC-ANT3)

AF-300 E11 Adjustable Frequency Drive

APPLICATIONS. Automatic warehouse. Trasportation lines

LARGE DIGITAL TEMPERATURE LED DISPLAYS

This module senses temperature and humidity. Output: Temperature and humidity display on serial monitor.

Multifunction Digital Timer

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Ordering details. Approval. Classification

Luminaire installation box Surface-mounted box Ceiling installation box

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Condition Monitoring Custom Products

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

IPM500D. Belluno / Italy September 2015

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

KNX Dimmer RGBW - User Manual

Operating instructions Electronic preset counter Type series 717

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

CDV07. Analog video distribution amplifier(s)

Controllers, series CON Indicators, series IND. Controllers and indicators

16-BIT LOAD CELL/DUAL STATUS INPUT

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

16 Stage Bi-Directional LED Sequencer

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

Standard signal metering in wall-mounting case

PRINCIPLES AND APPLICATIONS

SQM40/41 Actuators for air and gas dampers

Turnout Decoder TD Maxi. User Manual - version 0.1.6

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

INSTALLATION & USER GUIDE

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Safety Light Curtains GuardShield

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Series CT7N Bimetallic Overload Relays

BLOCK OCCUPANCY DETECTOR

Noise Detector ND-1 Operating Manual

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Operating instructions - High Performance LED Timer / / /

DCP100 Digital Control Programmer Specifications

Flat-Bed Module Recorders

BE3-GPR GENERATOR PROTECTIVE RELAY

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Operating Instructions

Global Water Instrumentation, Inc.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

EVC300i. Generator Automatic Voltage Regulator Operation Manual

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Sentinel I24 Digital Input and Output Configuration

Model TP4-PH Dual Input PH/ORP Display/Controller Operation and Instruction Manual

IEFIS G3 Inputs, outputs and Alarms

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

FWD8000 Dante enabled four wire box

Intelligent Security and Fire Ltd

Kuhnke Technical Data. Contact Details

Typical applications:

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

Technology Control Technology

BBV REAL TIME HQ DISPLAY QUAD MANUAL

Magnecraft Power Relays

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Model LD-TM DC Volts/4-20mA/mV/Slidewire Thermocouple/RTD/ Process Monitor/Controller Operation and Instruction Manual

Datasheet - SRB301LC 24VAC/DC

High performance circuit breakers

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Transcription:

HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an analogue output mirroring the 4-20mA input (the output is configurable to either 0-10V or 4-20mA). Input signal, trip configuration and power supply information are required to define any unit exactly. This information, together with a unique serial number is printed on the side label of each unit; records of the exact configuration of every product shipped are maintained at the factory. The input stage of the HS-509 produces an internal process signal of 0-10V DC corresponding to the input span. The trip set point potentiometers produce set point signals of 0-10V DC corresponding to the input span. These signals can be measured between terminal 13 (0V) and terminal 8 for set point 1 and terminal 4 for set point 2. This enables set points to be accurately set without the need for an input simulator. 0-10 V corresponds to 0-100% of the input range (see table 1 for common configurations). Internal circuitry compares the process signal with each of the set point levels and changes the state of the output relays and indicator LED s as the signal passes through the set point, using the internal switch settings the relays can be configured to either be latching or non-latching (see figure 3). The latching relays can be reset using either the small push button mounted on the front of the module, or via an external DC voltage applied to terminal 12. A factory configured start up delay is built in to prevent the relays being triggered for 30 seconds after the HS-509 has been powered up. Another user configurable delay of 5, 10, 30 or 60 seconds is applied to each relay to prevent any spurious vibration accidentally triggering an alarm, see figure 3 for switch settings. 1 QM021 Issue 2

2. Connection Details 0V IN +24V IN HS-509 CONNECTIONS OUTPUT TO REMOTE MONITOR -ma 16 15 1413 BLACK & SCREEN TERMINAL CONNECTIONS 13-0V Power In 14 - -I/P 15 - -O/P 16 - N/C +ma 12 1110 9 HS-509 SERIES MODULE WHITE HS-420 9 - +24V Power In 10 - +I/P 11 - +O/P 12 - Reset (External) SET 2 TRIP 2 SET 1 TRIP 1 5 - Relay 1 Common 6 - Relay 1 N/C 7 - Relay 1 N/O 8 - Relay 1 Setpoint Reset VIBRATION TRIP MODULE 1 - Relay 2 Common 2 - Relay 2 N/C 3 - Relay 2 N/O 4 - Relay 2 Setpoint HS509 INTERNAL SETTINGS 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 DSW3 DSW2 5 6 7 8 1 2 3 4 LIVE TO MACHINE ON ON M L N LIVE TO ALARM KLAXON L N Figure 1: HS-509 Example Wiring Diagram 3. Power Supply The power supply is connected into terminals 13 (negative) and 9 (positive). The supply voltage is indicated on the serial number label. APPLICATION OF VOLTAGES HIGHER THAN THAT STATED FOR THE SUPPLY MAY CAUSE DAMAGE TO THE INSTRUMENT. 4. Sensor Connections All sensor connections are made to terminals numbered 14 (-I/P) and 10 (+I/P) on the module. The -I/P terminal requires sensor ground (black in the HS-420) and screen be connected together. 2 QM021 Issue 2

5. Standard operation The HS-509 is configured to support either latching or non-latching relays. In the case of a non-latching configuration the relay is triggered when the input value passes through the pre-configured set point level, and stays above the level for the duration of the relay delay. The relay will then disengage when the input value falls below the set point, this is highlighted in the top half of figure 2. When the HS-509 is configured to work in latched mode the relay will again activate after the input has been above the set point value for at least the duration of the time delay, then it will not deactivate until either the internal reset or external reset are activated, regardless of the input value. The internal reset is a push-button mounted on the front of the module, the external reset is activated by applying a voltage (greater than 5V DC) to terminal 12. The principle of latched operation is shown in the second half of figure 2. Setpoint 2 Setpoint 1 Input Signal Relay 2 Relay 1 Non-Latched Operation Reset Relay 2 Latched Operation Relay 1 Figure 2: HS-509 Relay Non-Latching / Latching Principle of Operation 3 QM021 Issue 2

6. Set Points The set point values are determined via two variable resistors on the front of the module. To determine the value of the set point a voltage can be measured on either terminal 8 (set point 1) or terminal 4 (set point 2). This voltage is a 0-10V value which is proportional to the input value, table 1 provides information for common input ranges and the corresponding set points. Unless specified the set point for relay 1 will be 50% of full scale (terminal 8 will be at 5V) and relay 2 will be 75% of full scale (terminal 4 will be at 7.5V). Terminal Voltage Input Current 25mm/s Input 50mm/s Input 100mm/s Input 1 5.6 2.5 5 10 2 7.2 5 10 20 3 8.8 7.5 15 30 4 10.4 10 20 40 5 12 12.5 25 50 6 13.6 15 30 60 7 15.2 17.5 35 70 8 16.8 20 40 80 9 18.4 22.5 45 90 10 20 25 50 100 Table 1: Set Point Configuration Table Using this table it can be shown that using a 50mm/s accelerometer and a required alarm level of 20mm/s the input current would be 10.4mA and the voltage at the set point terminal would be 4V. 7. Repeated Output The HS-509 is capable of re-transmitting the input for use with other data analysis tools. This output can either be a direct representation of the 4-20mA input or a proportionally scaled 0-10V signal, this option can be configured using the internal switches, see figure 3. 4 QM021 Issue 2

8. Customer Configurable Options. On the circuit board for the HS-509 there are a number of switch settings which can be adjusted by the user to alter the configuration of the module. The following table shows how the switch settings can be altered to change the modules operation. DSW2 DSW2 ON OFF Function ON OFF Function 1 1 2 2 Relay 1 Latching 3 3 Relay 1 Non-Latching 4 4 5 5 6 6 Relay 2 Latching 7 7 Relay 2 Non-Latching 8 8 9 9 4-20mA Output 10 10 0-10V Output DSW3 ON OFF Function 1 5-second time delay 2 10-second time delay 3 30-second time delay 4 60-second time delay 5 5-second time delay 6 10-second time delay 7 30-second time delay 8 60-second time delay 9 N/A 10 N/A Relay 1 Relay 2 Figure 3: DSW2 and DSW3 Settings WARNING: DO NOT OPEN THE MODULE WHILST IT IS POWERED, DANGER OF ELECTRICAL SHOCK. 5 QM021 Issue 2

9. Electrical Characteristics: Input Power Requirements Maximum Current Set Points Relay Rating Relay Status Relay Delays Outputs Reset 4-20mA from HS-420 16-30VDC 120mA Dual Relays (front panel programmable) 3 Amps at 240VAC N/O or N/C, Latching / Non-Latcing 5, 10, 30 or 60 seconds (selectable) 4-20mA or 0-10VDC Internal Push Button, External Voltage Operating Temperature Range 0 to 55 C Emmision Immunity Installation Category (IEC664) Equipment Class (IEC536) EN6100-6-4:2001 EN6100-6-2:1999 II III 6 QM021 Issue 2