Studio Theatre Technical Specifications Theatre Manager Kim Scarlata 209.831.6205 Box Office Coordinator Laura Johnston 209.831.6208 Theatre Operations & Technical Assistant Matthew Morgan 209.831.6275 Box Office 209.831.6858 209.831.6271 fax Grand Theatre Center for the Arts 715 Central Avenue Tracy, CA 95376 www.atthegrand.org
c by Grand Theatre Center for the Arts Studio Theatre Maximum occupancy 110 c f Seating Layout Options 6S 9 II - I I u:::u:::ou 1i LN 1 11 11111 Ill I I Default Seating JT cfjvvvvv v v D4 JVVV ggggggg gggggg c c 64 Seats TotaI 4c c t t JVVV D t t :u ggggggg gggggg c D p D 5 F' s:;:s ii bblibbbs II - II II b:tdldbjbld 11/J 11f l lf l l l l.4 Added First Row bt ------t; II /J T II TT Il l Il l J Full Seating JT 77 Seats TotaI 104 Seats Total
Stage Stage Width 29 8 Stage Depth 22 Grid Height 18 Tech Gallery Height 13 Backstage Back hall provides crossover. Dressing and Green Rooms accessible via backstage. The backstage area is shared with the ETK Theatre and space may be very tight with both venues active. The Studio Theatre has a tech gallery or catwalk surrounding the stage on the sides and above the center seating. Lighting and Sound boards are located at the center of the tech gallery. The Stage Manager can be located there or on the 1 st floor House Left, or the backstage hall. Performers entrance is at 25 West 7 th Street. This is the Old Town Hall and Jail which serves as our Green Room. 2 Dressing Rooms 16 x 18 each * When Available* With 7 positions, 2 sinks, 1 toilet with shower, 1 wardrobe rack, 1 steamer, 1 iron and 1 ironing board in each. Green Room 21 x 25 * When Available* Company desk with phone (209.831.6284), small refrigerator, coffee maker, water cooler, couch and chairs, meeting table, and bathroom. Wired internet available. Fax line available. Storage space is limited in our facility. Please make arrangements with the Theatre Supervisor if you need to store unused or empty road boxes. Loading Area Accessible from West 7 th Street off of Central Street. Use West 7 th Street entrance to Grand Theatre Center. Loading doors inside on the left. Because of hard angles, please consult with Theatre Supervisor on anything bigger than 8 X 4. No ramp on site. If required, please notify in advance.
Fire Exit 5'-0" Back Stage Hall and Dressing rooms Green Room Fire Exitt Must remain clear 5'-6" 22'-4" 5'-6" 29'-8" Chair/Piano Storage 5'-3" +6" +12" +18" +24" +30" 5'-11" 5'-0" +36" +42" Public Entrance to Theatre Loading Door Loading Door Height is 6' 11" 7th Street Center Entrance Height is 6' 11" STUDIO THEATRE SHOW TITLE DESIGNED BY Theatre Dimensions REV DATE SCALE 1/8" = 1' DRAWING NO.
Theatrical Lighting Strand C21 Dimming. 55 2.4kW dimmers. Dimmer per circuit. Wireless Remote Focus Unit Lighting control console: ETC Express 24/48 Stage Electrical Circuit Schedule 36 Circuits in Grid 4 Circuits Up Stage Left Floor 4 Circuits Stage Left Tech Gallery 4 Circuits Up Stage Right Floor 4 Circuits Stage Right Tech Gallery 3 Circuits Center Tech Gallery Lighting Inventory 8 Etc Source Four Jr. Ellipsoidal 26 Degree 12 M size pattern holders 12 Etc Source Four Jr. Ellipsoidal 36 Degree 3 Donuts for S4 Jr. 4 Etc Source Four Jr. Ellipsoidal 50 Degree 2 Drop in Iris 18 Strand 6 Fresnels 3 Tophat Cable (#) = Number used in On Stage Rep Plot 6 (4) Twofers 10 (6) Stage Pin Cable 10 10 (5) Stage Pin Cable 5 6 (4) Stage Pin Cable 25 * Additional inventory may be available from ETK Theatre. Please check with Theatre Supervisor.
Catwalk 273-276 274 25 side 229-232 Floor 257-260 E 261-264 A 22 233 80 21 239 80 J F B 245-248 22 233 80 249-252 21 239 80 G C K 222 233 800 21 239 80 233-236 H 237-240 D Floor side side 225-228 270 269-272 272 28 Catwalk 27 265-268 253-256 241-2444 222-224 Catwalk = Dimmer Circuit Box (does not interfere with hanging positions) STUDIO THEATRE SHOW = Source Four Jr. @ 26,36 or 50 deg. = 6" Fresnel TITLE Repertory Light Plot DESIGNED BY J. Haskett DATE REV B SCALE 3/16" = 1' DRAWING NO.
Audio System 2 EAW JFX-290 Main Speakers. House Left and Right rigged from the Grid. Powered by 5 CROWN CTs 3000 Amplifiers 1 EAW SB-250 Sub rigged above Grid. Powered by 1 CROWN CTs 4200 (4ch) Midas Venice 160 16 Channel Console 12 mono microphone/line inputs, 4 stereo inputs 3 band parametric EQ on mic channels 2 Auxiliary sends 2 Monitor sends 2 Effects sends BSS Soundweb (sw9088iis) DSP control system. L and R input routing to main speakers and sub. Crossovers and EQ for main speakers. Assistive Listening processing. BOH monitor system. 6 Aux Amplifier Channels 1-2 @ 600W (4 or 8ohm) 3-6 @ 260W(4ohm) 180W(8ohm) Inputs at Booth patch bay 2 outputs each patch to 2 ch. Stage Left, 2 ch. Stage Right, and 2 ch. Up Stage Center, 4ch in Grid, 2ch Tech Gallery Left, 2 ch. Tech Gallery Right, and 2ch. Tech Gallery Center. 8 JBL JRX112M Monitor Wedges * When Available* 250W program 2 EAW JFX-290 Portable, with yolk and clamps 1 Tascam CD-X1500 Dual CD Player
Cable 4 XLR 10 4 Loudspeaker (Speakon) 25 8 XLR 25 4 XLR 50 Microphones 6 Generic vocal * Additional Microphones may be available from ETK stock. Please check with Theatre Supervisor. Miscellaneous 5 Microphone Boom Stands * Additional Stands, DIs, etc. may be available from ETK stock. Please check with Theatre Supervisor. Communications 6 1 channel belt pack 7 Standard single muff headset 1 2 channel stage management unit 1 8 TV monitors 1 (portable) Reference camera (portable) (FOH)
Catwalk 273-276 229-232 Floor Floor 225-228 257-260 245-248 233-236 261-264 249-252 237-240 269-272 Catwalk 265-268 253-256 241-244 2222-224 Catwalk = Dimmer Circuit Box (does not interfere with hanging positions) STUDIO THEATREE SHOW TITLE DESIGNED BY REV DATE SCALE 1/4" = 1' DRAWING NO.