Product information PRIO 112 BTE VC PRIO 105 BTE DM VC PRIO 105 BTE DM. Hearing Instruments Functions: Personalization Functions:

Similar documents
Hearing Solutions. Feature Chart 4 Feature Summary 6 Tinnitus Feature Chart 14 Tinnitus Feature Summary 15. Feature Chart 20 Feature Summary 22

TH Premium IF 19. Technical Data. 60 db / 125 db SPL (ear simulator) 50 db / 113 db SPL (2 ccm coupler)

HEARING SOLUTIONS CATALOG 2013

P r o d u c t I n f o R M A T I O N - X W / W / V

2017 Product Portfolio

TV Adapter 2 INSTALLATION GUIDE INSTRUCTIONS FOR USE

çıkış çıkış MPO Düşük frekansta maksimum çıkış MPO Düşük frekansta maksimum çıkış

Solutions for better hearing. audifon innovative, creative, inspired

rega ITE audifon GmbH & Co. KG Werner-von-Siemens-Straße 2 D Kölleda Tel Fax

sound generators for the relief and management of tinnitus and hyperacusis

Sound generators for the relief and management of tinnitus and hyperacusis

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

Multi Room Audio Matrix Switcher

Philips StressVue Tango M2 Interface Notes

RB-DSD8. 8 Channel Silence Switcher. Catalogue

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Schiller AT-10 plus Tango M2 Interface Notes

beyond your expectations

Hearing Aids for Tinnitus Patients: It s Not Just About Speech. Steve Benton, Au.D. VA Medical Center Decatur, GA

Coopers Gap Wind Farm AGL Energy Ltd 23-Aug-2016 Doc No AC-RP-02- Facade Sound Insulation Test Report

Instruction manual MK 8

Pulse Biomedical QRS-Card Tango M2 Interface Notes

SM12 & SM16 STEREO MIC/LINE MIXING CONSOLES OPERATION MANUAL

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

M2 Instruction Manual

RB-OA3,(R&C) 3 Studio On-Air Switcher. Catalogue

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

DM1624, DM1612, DM812

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Using the BHM binaural head microphone

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Software Package WW 9038 for the Sound Intensity Analysing System Type 3360 or the Digital Frequency Analyzer Type 2131

Cochlear Implants...4. Headsets...6. Magnets...7. Coils, Microphones & Transmitting Cables...8. Headset Cables...9. Accessories & Batteries...

MKE 2 Gold. Instruction manual

Burdick Quest Tango M2 Interface Notes

AMS 8DC. Weather-Resistant Enclosure

R&S Spectrum Rider FPH Handheld spectrum analyzer

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

Immerse yourself in 3D entertainment

Cardioline Cube Stress Tango M2 Interface Notes

VCR Integration for Record and Playback Extend the Intel TeamStation System's capabilities to include VCR Video in your conferences.

PHOENIX AUDIO. Owner s Manual

The Ultimate Gaming Projector

MOBILE AUDIO PRODUCT SUMMARY 2018

True Home Cinema Experience

Single 3 Way AES/EBU Passive Splitter With XLR Connectors CM-AESB3. Single 3 Way Passive AES3ID Splitter With BNC Connectors CM-MS3

Owners Manual PERREAUX

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

DVS 4 # # Superb Point-Source Performance

R&S RT-Zxx High-Bandwidth Probes Specifications

tech paper 2015 Effective feedback control

Acoustical comparison of bassoon crooks

TV Ears TV Speaker Installation Guide

Owner s Manual PRE1. v1.2. Triode Class A Line Preamplifier

MKH 8060 Directional studio microphone

EMPHASIZE THE GENUINE IN YOUR SOUND LCT 940

Portable Speakers. 3,000 Watt 18" Powered Subwoofer with KLARK TEKNIK DSP Technology, Speaker Modelling and ULTRANET Networking

Bio-logic AuDX PRO quick start Quick start guide

Application note for Peerless XLS 10" and XLS 12" subwoofer drivers for cars

Tinnitus Assessment Appointment

Fostex Distinctive PM0.4n Near-field Studio Monitors Now Shipping

Sound Insulation Reporter

Full-featured CW Microwave Counters for Field, Factory or Lab

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

2004 UltraVision LCD Projection Televisions

EMPHASIZE THE GENUINE IN YOUR SOUND LCT 840

Designed to excel in a wide variety of sound reinforcement applications, the full range DVS 6-WH is an ultracompact 240-Watt surface mount

What is the minimum sound pressure level iphone or ipad can measure? What is the maximum sound pressure level iphone or ipad can measure?

Dental Line. High frequency intraoral x-ray unit. radiology ahead

JBL f s New Differential Drive Transducers for VerTec Subwoofer Applications:

Mortara X-Scribe Tango+ Interface Notes

For high performance video recording and visual alarm verification solution, TeleEye RX is your right choice!

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

DS2460Q QAM Analysis Meter

SOUNDSTREAM. Parametric Equalizer. Owner's Manual and Installation Guide

5/8/2013. Tinnitus Population. The Neuromonics Sanctuary. relief. 50 Million individuals suffer from tinnitus

5100 MOBILE SURROUND MICROPHONE

DH400. Digital Phone Hybrid. The most advanced Digital Hybrid with DSP echo canceller and VQR technology.

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES

First to have USB connection PentaFOB Programmer

Turning your home into a SMART HOME.

Broadcaster Instruction Manual

DSP Monitoring Systems. dsp GLM. AutoCal TM

Datasheet: SimpliFiber Pro

PHASE HL SEL 1 HL SEL 2 EXT MONITOR ELAN ELAN ELAN ELAN MLM-201 HLM-201 HLM-201 TBM-201 MLM-201 GAIN GAIN GAIN LEFT GAIN RIGHT SELECT SELECT SELECT

AMS 6ICT. Weather-Resistant Enclosure

HD-CM HORIZON DIGITAL CABLE METER

easyspiral The world's fastest Spiral plater

DBXi Subwoofer Installation & Reference Manual

Tinnitus. Treatment for Professionals

UNPACKING. Check the contents of the carton to identify the following items: 4 x satellite speakers 1 x centre channel speaker

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

Portable Speakers. Dual 2 Way 15" Full Range Loudspeaker for Portable PA and Installation Applications

StepArray+ Self-powered digitally steerable column loudspeakers

Advanced security made easy PRO-555. Day/Night CCD Security Camera. Operating Instructions SW331-PR5 SR331-PR

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Transcription:

Product information PRIO 112 BTE VC PRIO 5 BTE DM VC PRIO 5 BTE DM PRIO hearing instruments deliver the most advanced automatic performance in the entry-level category. PRIO delivers a unique, individualized automatic program concept, with a variety of predefined signal processing strategies, optimized for your clients' needs. The extensive product portfolio with both adaptive directional and high-performance omnidirectional models enables you to cater for almost any hearing loss. db HL 5 BTE 112 BTE Hearing Instruments Functions: Highly precise signal processing in 7 frequency channels Fully Automatic Program with 5 Performance Priorities Music-, Telephone- or Auditorium-Program Adaptive Dualband Directionality (directional models) Adaptive Noise Reduction Soft Noise Management Adaptive Feedback Manager Adaptive Signal Unification OpenFit with low-frequency compensation Tracker (Data Logging) with fitting recommendations Personalization Functions: Client Profile with Client Lifestyle Priorities Simple, intuitive fine-tuning tools Performance Priorities in the Automatic Program Individually adjustable programs for DAI/FM and T-Coil A choice of cosmetic open fittings with SPIRA flex Complete product portfolio with earhooks or thin sound tubes Directional and high-performance omnidirectional models Optional Remote Control for all models Stylish BTE color range Frequency (Hz) PRIO 112 BTE VC A compact BTE with omnidirectional response, a size 13 battery, and rotary volume control, suitable for mild to severe/profound hearing losses. PRIO 5 BTE DM VC A compact BTE with an adaptive directional microphone system, a size 13 battery and rotary volume control, suitable for mild to severe hearing losses. PRIO 5 BTE DM A compact BTE with an adaptive directional microphone system, a size 13 battery, VC-less, suitable for mild to severe hearing losses. SPIRA flex More cosmetic solutions and open fitting capabilities with the SPIRA flex Sound Tube System. Available for all PRIO BTE's. Innovative Hearing Solutions

PRIO information PRIO BTE 112 BTE VC 5 BTE DM VC 5 BTE DM Current Gain Output Distortion General Information Additional Information IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 (2cc) (Ears.) (2cc) (Ears.) (2cc) (Ears.) OSPL, Peak db SPL 133 137* 123 127 123 127 OSPL, Hz db SPL 123 131 112 121 112 121 HFA OSPL, ANSI db SPL 126 113 113 Full-On Gain, Peak db 71 76 63 63 Full-On Gain, Hz db 61 69 52 58 52 58 HFA Full-On Gain, ANSI db 65 53 53 Reference Test Gain, IEC db 47 55 36 44 36 44 Reference Test Gain, ANSI db 49 35 35 Quiescent Current ma 1.2 1.2 1.2 1.2 1.2 1.2 Operating Current, IEC ma 1.3 1.2 1.2 1.2 1.2 1.2 Operating Current, ANSI ma 1.4 1.2 1.2 Battery type 13 13 13 0/0/ Hz typ., IEC % <2 / <1 / <1 <2 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 0/0/ Hz typ., ANSI % <2 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 Frequency Range, ANSI Hz 1 50 Equiv. Input Noise, IEC/ANSI 1) db 17/12 15/13 15/13 Telecoil 1 ma/m Hz, IEC db SPL 94 1 83 92 83 92 Telecoil HFA SPLITS, ANSI db SPL 9 96 96 Remote Control reception coil yes yes yes Earhooks 8 db (std.), 0 db (opt.) 8 db (std.), 0 db (opt.) 8 db (std.), 0 db (opt.) Childrens Earhooks 8 db (opt.), 0 db (opt.) 8 db (opt.), 0 db (opt.) 8 db (opt.), 0 db (opt.) SPIRA flex Sound Tube 0.9/1.3 optional optional optional Programmable telecoil yes yes yes Push button yes yes yes FM communication yes yes yes DAI yes yes yes Volume control yes yes 1) Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 118 if not otherwise mentioned. ANSI refers to ANSI S3.22-03. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. All measurements are based on earhook without filter. *Special care should be exercised in selecting and fitting a hearing aid whose maximum sound pressure level exceeds 132 db, as measured with an IEC 711: 1981 occluded ear simulator, because there may be risk of impairing the remaining hearing of the hearing instrument user.

Frequency responses IEC 118-7 2cc Coupler (IEC 126) IEC 118-0 Earsimulator (IEC 711) Output/dB SPL Output/dB SPL 1 1 1 PRIO 112 BTE VC Output OSPL Full-On Gain 1 1 1 2 0 1k 1k6 2k 2k5 4k 8k Frequency/Hz 2 0 1k 1k6 2k 2k5 4k 8k Frequency/Hz Output/dB SPL Output/dB SPL 1 1 1 PRIO 5 BTE DM VC PRIO 5 BTE DM Output OSPL Full-On Gain 1 1 1 2 0 1k 1k6 2k 2k5 4k 8k Frequency/Hz 2 0 1k 1k6 2k 2k5 4k 8k Frequency/Hz Measurements based on earhook without filter Measurements based on earhook with filter

PRIO BTE Color Range beige grey brown anthracite black SPIRA flex Sound Tube System SPIRA flex Sound Tube System for more cosmetic and open fitting solutions. Please refer to the SPIRA flex Product Brochure REF. 951-18-7-00 or the SPIRA flex Product Information REF. 951-18-6-00 SPIRA flex Master Fitting Kit containing all SPIRA flex components REF. 8--0-00

DAI/FM Adapters FMA3 Adapter For FM communication systems only REF. 399--5-00 DAI3 Adapter For connection to Hi-Fi, TV set, PC, etc. REF. 399--5-00 Remote Control All PRIO hearing systems can be operated with the optional Bernafon Remote Control RC-S. Standard Remote Control REF. 1-02-3-00 For clients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered to ensure correct coding. Custom Remote Control REF. 1-02-3-00 Adapters and cables PRIO is programmed with OASIS plus, Version 7.0 or later a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlink TM is required. Programming adapter Programming adapter REF. 3-01-151-00 Programming cables Nr. 2, NEW STANDARD (HiPro) Blue, left REF. 384--033-00 Red, right REF. 384--032-00 Nr. 2, NEW STANDARD (NOAHlink) Blue, left REF. 384--035-00 Red, right REF. 384--034-00 Note: Always use new batteries for programming.

Fitting in OASIS plus To fully meet your fitting priorities, OASIS plus offers an efficient workflow: Lifestyle Priorities Client Profile: Personal data, Audiogram, and Lifestyle Profile provide a structured framework for identifying all the specific needs of your client. It is this information that drives the automatic behaviour of PRIO. Automatic Program Allocation: OASIS plus defines the assignment of user programs to cover the client s Lifestyle Priorities. P1 Automatic Program Universal P1 Automatic Program Performance Priorities: Universal Speech Comfort Responsive Pure Performance Priorities: OASIS plus automatically defines the within the automatic program. Master Tools: is used for the global fine-tuning of all programs simultaneously. Program Optimize: offers a dedicated set of controls for the specific fine-tuning of each program. Innovative Hearing Solutions Manufacturer: Bernafon AG Morgenstrasse 131 18 Bern Switzerland Phone +41 (0)31 998 15 15 Fax + 41 (0)31 998 15 www.bernafon.com Quality System DS/EN ISO 01 DS/EN ISO 13485 Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 512 Wickham Street Fortitude Valley QLD 06 Australia Freecall 9 111 Phone +61 (0)7 32 00 Fax +61 (0)7 3252 48 www.bernafon.com.au Bernafon New Zealand Ltd. 19 Tarndale Grove, Albany P.O. Box 2 149 North Harbour Auckland 13 New Zealand Phone +64 (0)9 9 42 Fax +64 (0)9 9 42 43 www.bernafon.co.nz 09.06/BAG/951-18-4-00/subject to change

Product Information PRIO 6 BTE DM PRIO hearing instruments deliver the most advanced automatic performance in its class. PRIO delivers a unique, individualized automatic program concept, with a variety of predefined signal processing strategies, optimized for your clients' needs. PRIO 6 BTE DM is an aesthetic and upgradeable solution that lasts for years, even with increasing hearing loss. Hearing Instruments Functions: db HL 6 BTE DM Highly precise signal processing in 7 frequency channels Fully Automatic Program with 5 Performance PRIOrities Music-, Telephone- or Auditorium-Program Adaptive Dualband Directionality Adaptive Noise Reduction Soft Noise Management Adaptive Feedback Manager Adaptive Signal Unification OpenFit with low-frequency compensation Tracker (Data logging) with fitting recommendations Personalization Functions: Client Profile with Lifestyle Priorities Simple, intuitive fine-tuning tools Performance PRIOrities in the Automatic Program Individually adjustable program for DAI Choice of several SPIRA flex thin sound tubes and ear-pieces Choice of directionality performance Optional Remote Control Stylish color range Frequency (Hz) PRIO 6 BTE DM A micro size BTE instrument with an adaptive directional microphone system, a size 312 battery, suitable for mild to moderate hearing losses.

PRIO Information PRIO 6 BTE DM SPIRA flex SPIRA flex 0.9 1.3 IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 ANSI S3.22 ANSI S3.22 (2cc) (Ears.) (2cc) (Ears.) Current Gain Output Additional Information OSPL, Peak db SPL 117 123 121 126 OSPL, Hz db SPL 2 112 8 118 HFA OSPL db SPL 8 113 Full-On Gain, Peak db 47 54 57 Full-On Gain, Hz db 36 45 41 51 HFA Full-On Gain db 41 46 Reference Test Gain db 37 36 42 Quiescent Current ma 1.2 1.2 1.2 1.2 Operating Current ma 1.3 1.2 1.3 1.2 Battery type 312 Distortion 0/0/ Hz typ. % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 Frequency Range Hz 00 50 Equiv. Input Noise 1) db 16 19 12 16 Remote Control reception yes Push button yes DAI yes Volume control by Remote Control 1) Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 118 and ANSI S3.22-03 with SPIRA flex tubes #2. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes.

Frequency Response IEC 118-7 2cc Coupler (IEC 318-5 1 ) IEC 118-0 Earsimulator (IEC 711) 1 1 1 PRIO 6 BTE DM Output OSPL Full-On Gain 1 1 1 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k Measurements with Tube 1.3 mm Measurements with Tube 0.9 mm 1) Identical to coupler described in withdrawn standard IEC 126 SPIRA flex Sound Tube System SPIRA flex Sound Tube System for more cosmetic and open fitting solutions. Please refer to the SPIRA flex Product Brochure REF. 951-18-7-00 or the SPIRA flex Product Information REF. 951-18-6-00 SPIRA flex Master Fitting Kit containing all SPIRA flex components REF. 8--0-00

Quick Fitting Guide Different acoustic options result in different benefits Open Dome Tulip Dome Custom Tip Canal Mold Vent < 3 mm Vent = mm SPIRA flex 0.9 SPIRA flex 1.3 Maximum Fitting Range Minimum Feedback Risk Maximum Cosmetics Minimum Occlusion Suggested maximum fittings with different acoustic combinations SPIRA flex tube 0.9 SPIRA flex tube 1.3 db HL db HL with Open Dome with Tulip Dome with Custom Tip or Canal Mold with Tulip Dome with Canal Mold, large vent with Canal Mold, no vent

PRIO 6 BTE DM Color Range beige grey brown black titanium Remote Control All PRIO systems can be operated with the optional Bernafon Remote Control RC-S. Standard Remote Control REF. 1-02-3-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control REF. 1-02-3-00 Cables and Adapters PRIO 6 BTE DM is programmed with OASIS plus, Version 8.0 or later a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlink is required. Programming cables Nr. 2, NEW STANDARD (HiPro) Blue, left REF. 384--033-00 Red, right REF. 384--032-00 Programming Adapter Programming adapter REF. 399--6-00 Nr. 2, NEW STANDARD (NOAHlink) Blue, left REF. 384--035-00 Red, right REF. 384--034-00 DAI 4 Adapter For connection to Hi-Fi, TV set, PC, etc. REF. 399--521-00 Note: Always use new batteries for programming.

Fitting in OASIS plus To fully meet your fitting PRIOrities, OASIS plus offers an efficient workflow: Lifestyle Priorities Client Profile: Personal data, Audiogram, and Lifestyle Profile provide a structured framework for identifying all the specific needs of your client. It is this information that drives the automatic behaviour of PRIO. Automatic Program Allocation: OASIS plus defines the assignment of user programs to cover the client s Lifestyle Priorities. P1 Automatic Program Universal P1 Automatic Program Performance Priorities: Universal Speech Comfort Responsive Performance Priorities: OASIS plus automatically defines the within the automatic program. Master Tools: is used for the global fine-tuning of all programs simultaneously. Program Optimize: offers a dedicated set of controls for the specific fine-tuning of each program. Pure Manufacturer: Bernafon AG Morgenstrasse 131 18 Bern Switzerland Phone +41 (0)31 998 15 15 Fax + 41 (0)31 998 15 www.bernafon.com Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 512 Wickham Street Fortitude Valley QLD 06 Australia Freecall 9 111 Phone +61 (0)7 32 00 Fax +61 (0)7 3252 48 www.bernafon.com.au Bernafon New Zealand Ltd. 19 Tarndale Grove, Albany P.O. Box 2 149 North Harbour Auckland 13 New Zealand Phone +64 (0)9 9 42 Fax +64 (0)9 9 42 43 www.bernafon.co.nz 08.09/BAG/951-19-4-00/subject to change

Product information PRIO 2 ITE VC PRIO 5 ITE DM VC PRIO 322 ITC VC PRIO 315 ITC DM VC PRIO 5 ITC DM PRIO 415 MC DM PRIO 0 CIC PRIO hearing instruments deliver the most advanced automatic performance in the entry-level category. PRIO delivers a unique, individualized automatic program concept, with a variety of predefined signal processing strategies, optimized for your clients' needs. The extensive product portfolio with both adaptive directional and high-performance omnidirectional models enables you to cater for almost any hearing loss. Hearing Instruments Functions: Highly precise signal processing in 7 frequency channels Fully Automatic Program with 5 Performance Priorities Music-, Telephone- or Auditorium-Program Adaptive Dualband Directionality (directional models) Adaptive Noise Reduction Soft Noise Management Adaptive Feedback Manager Adaptive Signal Unification OpenFit with low-frequency compensation Tracker (Data Logging) with fitting recommendations Personalization Functions: Client Profile with Client Lifestyle Priorities Simple, intuitive fine-tuning tools Performance Priorities in the Automatic Program Individually adjustable programs for T-Coil Automatic Telephone Program for ITE/ITC Open fittings with collection vents Complete product portfolio from Mini CIC to Power ITE Directional and high-performance omnidirectional models Optional Remote Control for all models Stylish color range Innovative Hearing Solutions db HL 415/0 5/322/315/5 2 Frequency (Hz) PRIO 2 ITE VC An omnidirectional full concha instrument with a size 13 battery and a rotary volume control for mild to severe hearing losses. PRIO 5 ITE DM VC An adaptive directional full concha instrument with a size 13 battery and a rotary volume control for mild to moderately severe hearing losses. PRIO 322 ITC VC An omnidirectional canal or half shell instrument with a size 312 battery and rotary volume control for mild to moderately severe hearing losses. PRIO 315 ITC DM VC An adaptive directional canal or half shell instrument with a size 312 battery and rotary volume control for mild to moderately severe hearing losses. PRIO 5 ITC DM An adaptive directional canal instrument with a size 312 battery for mild to moderately severe hearing losses. PRIO 415 MC DM An adaptive directional mini-canal instrument with a size battery for mild to moderate hearing losses. PRIO 0 CIC An omnidirectional completely in the canal instrument with a size battery for mild to moderate hearing losses.

PRIO information PRIO ITE 2 ITE VC 5 ITE DM VC Current Gain Output Distortion General Information Additional Information IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 (2cc) (Ears.) (2cc) (Ears.) OSPL, Peak db SPL 1 129 112 122 OSPL, Hz db SPL 113 121 5 113 HFA OSPL, ANSI db SPL 115 7 Full-On Gain, Peak db 55 64 46 58 Full-On Gain, Hz db 44 53 49 HFA Full-On Gain, ANSI db 47 41 Reference Test Gain, IEC db 37 45 29 38 Reference Test Gain, ANSI db 37 29 Quiescent Current ma 1.3 1.3 1.2 1.2 Operating Current, IEC ma 1.3 1.3 1.2 1.2 Operating Current, ANSI ma 1.3 1.2 Battery type 13 13 0/0/ Hz typ., IEC % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <2 / <2 / <1 0/0/ Hz typ., ANSI % <1 / <1 / <1 <1 / <1 / <1 Frequency Range, ANSI Hz 00 70 Equiv. Input Noise, IEC/ANSI 1) db /15 14/14 Telecoil 1 ma/m Hz, IEC db SPL 76 84 72 81 Telecoil HFA SPLITS, ANSI db SPL 94 85 Remote Control reception coil optional optional Programmable Telecoil optional optional AutoTelephone optional optional Push button yes yes Volume control yes yes 1) Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 118 if not otherwise mentioned. ANSI refers to ANSI S3.22-03. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes.

PRIO information PRIO ITE 322 ITC VC 315 ITC DM VC 5 ITC DM Current Gain Output Distortion General Information Additional Information IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 (2cc) (Ears.) (2cc) (Ears.) (2cc) (Ears.) OSPL, Peak db SPL 115 125 112 122 1 OSPL, Hz db SPL 5 113 5 113 2 111 HFA OSPL, ANSI db SPL 7 7 4 Full-On Gain, Peak db 44 53 43 54 41 52 Full-On Gain, Hz db 34 43 38 47 34 43 HFA Full-On Gain, ANSI db 37 38 34 Reference Test Gain, IEC db 27 35 29 38 27 35 Reference Test Gain, ANSI db 33 29 27 Quiescent Current ma 1.2 1.2 1.1 1.1 1.1 1.1 Operating Current, IEC ma 1.2 1.2 1.2 1.2 1.2 1.2 Operating Current, ANSI ma 1.2 1.2 1.2 Battery type 312 312 312 0/0/ Hz typ., IEC % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <1 / <1 / <1 0/0/ Hz typ., ANSI % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 Frequency Range, ANSI Hz 00 70 70 Equiv. Input Noise, IEC/ANSI 1) db 19/16 14/15 14/15 Telecoil 1 ma/m Hz, IEC db SPL 66 75 79 67 75 Telecoil HFA SPLITS, ANSI db SPL 83 85 84 Remote Control reception coil optional optional optional Programmable Telecoil optional optional optional AutoTelephone optional optional optional Push button yes yes yes Volume control yes yes 1) Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 118 if not otherwise mentioned. ANSI refers to ANSI S3.22-03. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes.

PRIO information PRIO ITE 415 MC DM 0 CIC Current Gain Output Distortion General Information Additional Information IEC 118-7 IEC 118-0 IEC 118-7 IEC 118-0 (2cc) (Ears.) (2cc) (Ears.) OSPL, Peak db SPL 4 115 4 115 OSPL, Hz db SPL 97 6 97 5 HFA OSPL, ANSI db SPL 98 98 Full-On Gain, Peak db 34 45 34 45 Full-On Gain, Hz db 39 39 HFA Full-On Gain, ANSI db 31 Reference Test Gain, IEC db 22 31 22 31 Reference Test Gain, ANSI db 22 21 Quiescent Current ma 1.1 1.1 0.8 0.8 Operating Current, IEC ma 1.1 1.1 0.8 0.8 Operating Current, ANSI ma 1.1 0.8 Battery type 0/0/ Hz typ., IEC % <1 / <1 / <1 <1 / <1 / <2 <1 / <1 / <1 <1 / <1 / <1 0/0/ Hz typ., ANSI % <1 / <1 / <1 <1 / <1 / <1 Frequency Range, ANSI Hz 70 70 Equiv. Input Noise, IEC/ANSI 1) db 14/14 19/17 Telecoil 1 ma/m Hz, IEC db SPL Telecoil HFA SPLITS, ANSI db SPL Remote Control reception coil optional optional Programmable Telecoil AutoTelephone Push button optional optional Volume control 1) Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 118 if not otherwise mentioned. ANSI refers to ANSI S3.22-03. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes.

Frequency responses IEC 118-7 2cc Coupler (IEC 126) IEC 118-0 Earsimulator (IEC 711) 1 1 PRIO 2 ITE VC Output OSPL Full-On Gain 1 1 1 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k 1 PRIO 5 ITE DM VC Output OSPL Full-On Gain 1 1 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k 1 PRIO 322 ITC VC 1 1 Output OSPL Full-On Gain 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k 1 PRIO 315 ITC DM VC 1 1 Output OSPL Full-On Gain 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k

Frequency responses IEC 118-7 2cc Coupler (IEC 126) IEC 118-0 Earsimulator (IEC 711) 1 PRIO 5 ITC DM Output OSPL Full-On Gain 1 1 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k 1 PRIO 415 MC DM Output OSPL Full-On Gain 1 1 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k 1 PRIO 0 CIC 1 1 Output OSPL Full-On Gain 0 2 0 1k 1k6 2k 2k5 4k 8k 2 0 1k 1k6 2k 2k5 4k 8k

PRIO Colors All colors are available for all instruments. beige pink brown dark brown Adapters and cables PRIO is programmed with OASIS plus, Version 7.0 or later a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlink is required. Programming cables Nr. 2, NEW STANDARD (HiPro) Blue, left REF. 384--033-00 Red, right REF. 384--032-00 Programming adapter for all ITE s FlexConnect REF. 3-01-1-05 Programming cables Nr. 2, NEW STANDARD (NOAHlink) Blue, left REF. 384--035-00 Red, right REF. 384--034-00 Note: Always use new batteries for programming. Remote Control All PRIO hearing systems can be operated with the optional Bernafon Remote Control RC-S. Standard Remote Control REF. 1-02-3-00 For clients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered to ensure correct coding. Custom Remote Control REF. 1-02-3-00

Fitting in OASIS plus To fully meet your fitting priorities, OASIS plus offers an efficient workflow: Lifestyle Priorities Client Profile: Personal data, Audiogram, and Lifestyle Profile provide a structured framework for identifying all the specific needs of your client. It is this information that drives the automatic behaviour of PRIO. Automatic Program Allocation: OASIS plus defines the assignment of user programs to cover the client s Lifestyle Priorities. P1 Automatic Program Universal P1 Automatic Program Performance Priorities: Universal Speech Comfort Responsive Pure Performance Priorities: OASIS plus automatically defines the within the automatic program. Master Tools: is used for the global fine-tuning of all programs simultaneously. Program Optimize: offers a dedicated set of controls for the specific fine-tuning of each program. Innovative Hearing Solutions Manufacturer: Bernafon AG Morgenstrasse 131 18 Bern Switzerland Phone +41 (0)31 998 15 15 Fax + 41 (0)31 998 15 www.bernafon.com Quality System DS/EN ISO 01 DS/EN ISO 13485 Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 512 Wickham Street Fortitude Valley QLD 06 Australia Freecall 9 111 Phone +61 (0)7 32 00 Fax +61 (0)7 3252 48 www.bernafon.com.au Bernafon New Zealand Ltd. 19 Tarndale Grove, Albany P.O. Box 2 149 North Harbour Auckland 13 New Zealand Phone +64 (0)9 9 42 Fax +64 (0)9 9 42 43 www.bernafon.co.nz 09.06/BAG/951-18-5-00/subject to change