E5500 Phase Noise Measurement System Version A.02.00

Similar documents
Noise Detector ND-1 Operating Manual

Agilent E5505A Phase Noise Measurement System

Instruction Manual Model # Block Upconverter

Instruction Manual Model BlockUpconverter

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Installation Note. Agilent 89441A Option AYC Installation Kit

Instructions. P MHz 1X/10X Passive Probe

Model P/03P Upconverters

Agilent N6467A BroadR-Reach Compliance Test Application. Methods of Implementation

Keysight 16048G/H Test Leads

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Agilent N5431A XAUI Electrical Validation Application

Model /29S RF Splitter

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Instruction Manual Model Block Up/Downconverter

Assembly Level Service Guide

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved.

SAWM60 AUDIO/VIDEO MODULATOR

HMA-860H AGILE MODULATOR

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Agilent M9330A Series PXI-H Arbitrary Waveform Generator

USB-TG124A Tracking Generator User Manual

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

N2099A Option H10 Synthesizer

Agilent Technologies N5241/42AS Option H30 and H31. User s and Service Guide

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Dish Diversity Switch

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

NS-3 RF Noise Source Operation Manual

Installation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number

Agilent 87075C Multiport Test Set Product Overview

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

OptEnet OC48 Regenerator Module User Manual

User Manual. Model 979T and 979R Digital Audio Converters

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

HD-CM HORIZON DIGITAL CABLE METER

MaxView Cinema Kit Quick Install Guide

Colour Explosion Proof Video Camera USER MANUAL VID-C

P XGA TFT Monitor. User s Manual

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model 1421 Distribution Amplifier

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

PicoScope 2000 Series PC Oscilloscopes

Manual No: Revision: D. IQ Box. Software Upgrade Instructions

MANUAL ENGLISH Core Club Ordercode: D2314

R&S FPC-Z10 Teaching Kit Getting Started

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Keysight PXA Signal Analyzer

VGA to DVI Extender over Fiber SET

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

PicoScope 3000 Series Automotive User guide

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Keysight Noise Figure Measurement Capability Upgrade Kit

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Modular Block Converter Systems

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

User Manual. TDS3SDI 601 Digital Video Application Module

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

CDV07. Analog video distribution amplifier(s)

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

SM-10 SAT Level Meter User s Manual

HD Digital Set-Top Box Quick Start Guide

Simplified Block Diagram

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Product Operation Manual

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

MS2540 Current Loop Receiver with RS485 Communication

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Trusted 40 Channel 120 Vac Digital Input FTA

Keysight E8740A-040 Advanced Radar Signal Analysis Solution

32 Channel CPCI Board User Manual

Trusted 40 Channel 120 Vac Digital Input FTA

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment


SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

User Manual. Model 1351 DVI Repeater with HDCP

Tablet Oscilloscope Quick Guide

PXI MICROWAVE IF DOWNCONVERTER MODULE

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

HD Digital MPEG2 Encoder / QAM Modulator

2013, 2014 Hewlett-Packard Development Company, L.P.

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

JD725A Cable and Antenna Analyzer - Dual Port

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Winmate Communication INC.

Evolution Digital HD Set-Top Box Important Safety Instructions

X-Series Expansion Cards. X-Video Card

Agilent N6465A emmc Compliance Test Application

RIGOL. 快速指南 DSA800 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Transcription:

E5500 Phase Noise Measurement System Version A.02.00 Installation Guide for E5500B Agilent Technologies

COPYRIGHT 2002 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR BY ANY MEANS (INCLUDING ELECTRONIC STORAGE AND RETRIEVAL OR TRANSLATION INTO A FOREIGN LANGUAGE) WITHOUT PRIOR AGREEMENT AND WRITTEN CONSENT OF AGILENT TECHNOLOGIES, INC., AS GOVERNED BY UNITED STATES AND INTERNATIONAL COPYRIGHT LAWS. DOCUMENT PART NO. E5500-90022 PRINTED IN USA MARCH 2002 EDITION 1.0 Notices Warranty The material contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products. For assistance, call your nearest Agilent Technologies Sales and Service Office (see Table 2 on page 6). WARNING: A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAUTION: A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. 2 E5500B Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed.1.0

Safety summary The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for the customer's failure to comply with these requirements. WARNING: DO NOT REMOVE THE INSTRUMENT COVER Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made only by qualified service personnel. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. General This product is a Safety Class 1 instrument (provided with a protective earth terminal). The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions. All light emitting diodes (LEDs) used in this product are Class 1 LEDs as per IEC 60825-1. WARNING: DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or flames. Environmental conditions Unless otherwise noted in the specifications, this instrument or system is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters. Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range. Before applying power Verify that the product is set to match the available line voltage, the correct fuse is installed, and all safety precautions are taken. Note the instrument's external markings described in Table 1. Document Part No. E5500-90022Ed. 1.0 E5500B Phase Noise Measurement System Version A.02.00 3

Ground the instrument To minimize shock hazard, the instrument chassis and cover must be connected to an electrical protective earth ground. The instrument must be connected to the ac power mains through a grounded power cable, with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury. Fuses Use only fuses with the required rated current, voltage, and specified type (normal blow, time delay). Do not use repaired fuses or short-circuited fuse holders. To do so could cause a shock or fire hazard. Safety symbols and instrument markings Symbols and markings in manuals and on instruments alert you to potential risks, provide information about conditions, and comply with international regulations. Table 1 defines the symbols and markings you may find in a manual or on an instrument. Table 1 Safety symbols and instrument markings Safety symbols Warning: risk of electric shock. Warning: hot surface Caution: refer to accompanying documents. Laser radiation symbol: marked on products that have a laser output. Alternating current. Both direct and alternating current. Three-phase alternating current. Earth (ground) terminal Protective earth (ground) terminal 4 E5500B Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed.1.0

Table 1 Safety symbols and instrument markings (continued) Safety symbols Frame or chassis terminal Terminal is at earth potential. Used for measurement and control circuits designed to be operated with one terminal at earth potential. Terminal for neutral conductor on permanently installed equipment. Terminal for line conductor on permanently installed equipment. Instrument markings Standby (supply); units with this symbol are not completely disconnected from ac mains when this switch is off. To completely disconnect the unit from ac mains, either disconnect the power cord, or have a qualified electrician install an external switch. The CE mark is a registered trademark of the European Community. If it is accompanied by a year, it indicates the year the design was proven. The CSA mark is a registered trademark of the Canadian Standards Association. N10149 The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australian EMC Framework regulations under the terms of the Radio Communications Act of 1992. 1SM1-A This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4). Document Part No. E5500-90022Ed. 1.0 E5500B Phase Noise Measurement System Version A.02.00 5

Service and Support Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center. Agilent on the Web You can find information about technical and professional services, product support, and equipment repair and service on the Web: http://www.agilent.com/ contacts/english/noscript.html Double-click the link to Test & Measurement. Select your country from the drop-down menus. The Web page that appears next has contact information specific for your country. Agilent by Phone If you do not have access to the Internet, call one of the numbers in Table 2. Table 2 Agilent Call Centers and Regional Headquarters United States and Canada: Test and Measurement Call Center (800) 452 4844 (toll-free in US) Europe: (41 22) 780 8111 Japan: Measurement Assistance Center (81) 0426 56 7832 Latin America: 305 269 7548 Asia-Pacific: (85 22) 599 7777 6 E5500B Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed.1.0

1 E5500B Phase Noise Measurement System Introduction 1-2 System Requirements 1-3 Unpacking Your System 1-4 Installing the Hardware 1-5 Preparing for Installation 1-5 Accessing Your Computer s Expansion Slots 1-5 Taking ESD Precautions 1-6 Installing the Interface Card 1-7 Installing the PC Digitizer Card 1-9 Making System Connections 1-10 Installing the Agilent I/O Libraries 1-13 Configuring the Agilent I/O Libraries 1-14 Installing the PC Digitizer Software 1-17 Installing the Measurement Software 1-18 Locating Documents that Support the E5500 1-19 Using the Asset Manager to Configure your System 1-20 Configuring the Agilent 70420A Test Set 1-22 Configuring the PC Digitizer 1-26 Configuring the Agilent E4411A/B (ESA-L1500A) Swept Analyzer 1-30 Entering the License Key for the Phase Noise Test Set 1-31 Starting the Measurement Software 1-34 Using Server Hardware Connections to Specify Assets for the Confidence Test 1-36 Running the Software Confidence Test 1-38 Beginning the Measurement 1-40 Making the Measurement 1-42 Congratulations 1-42 2 Connect Diagrams Figure 2-1. E5501B Standard Connect Diagram 2-2 Figure 2-2. E5501B Opt. 001 Connect Diagram 2-3 Figure 2-3. E5501B Opt. 201 Connect Diagram 2-4 Figure 2-4. E5502B Standard Connect Diagram 2-5 Figure 2-5. E5502B Opt. 001 Connect Diagram 2-6 Figure 2-6. E5502B Opt. 201 Connect Diagram 2-7 Figure 2-7. E5503B Standard Connect Diagram 2-8 Figure 2-8. E5503B Opt. 001 Connect Diagram 2-9 Figure 2-9. E5503B Opt. 201 Connect Diagram 2-10 Figure 2-10. E5504B Standard Connect Diagram 2-11 Figure 2-11. E5504B Opt. 001 Connect Diagram 2-12 Figure 2-12. E5504B Opt. 201 Connect Diagram 2-13 Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 Contents-1

Contents-2 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

1 E5500B Phase Noise Measurement System Introduction, page 1-2 System Requirements, page 1-3 Unpacking Your System, page 1-4 Installing the Hardware, page 1-5 Installing the Agilent I/O Libraries, page 1-13 Configuring the Agilent I/O Libraries, page 1-14 Installing the PC Digitizer Software, page 1-17 Installing the Measurement Software, page 1-19 Locating Documents that Support the E5500, page 1-20 Using the Asset Manager to Configure your System, page 1-21 Entering the License Key for the Phase Noise Test Set, page 1-32 Starting the Measurement Software, page 1-35 Using Server Hardware Connections to Specify Assets for the Confidence Test, page 1-37 Running the Software Confidence Test, page 1-39 Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-1

1 E5500B Phase Noise Measurement System Introduction Introduction Table 1-1 shows which procedures in this document to follow depending on the system you purchased. This installation guide take you through the process of installing both the hardware and the E5500 Phase Noise software. If you ordered a preconfigured system from Agilent Technologies, follow the alternate steps in the right column of Table 1-1. A confidence test is also included as the last step in the installation procedure. Table 1-1 Installation Steps Procedures in this Document Pertain to Option 1FF (without a computer) Pertain to a preconfigured E5500B system System Requirements on page 1-3 X N/A Unpacking Your System on page 1-4 X X Installing the Hardware on page 1-5 X N/A Installing the Agilent I/O Libraries on page 1-13 X N/A Configuring the Agilent I/O Libraries on page 1-14 X N/A Installing the PC Digitizer Software on page 1-17 X N/A Installing the Measurement Software on page 1-19 X N/A Locating Documents that Support the E5500 on page 1-20 Using the Asset Manager to Configure your System on page 1-21 Entering the License Key for the Phase Noise Test Set on page 1-32 X X X X N/A N/A Starting the Measurement Software on page 1-35 X X Using Server Hardware Connections to Specify Assets for the Confidence Test on page 1-37 X X Running the Software Confidence Test on page 1-39 X X 1-2 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 System Requirements System Requirements The setup program in the E5500 Phase Noise Measurement Software makes installation easy. In case you want a quick review of the system requirements, we have listed them first. The system requirements for the phase noise measurement software include items in the following list and the connectors and adapters shown in Table 1-2: Pentium II microprocessor or greater (100 MHz or greater) Minimum of 128 megabytes (MB) of memory (RAM) 10 gigabyte (GB) hard disk Super Video Graphics Array (SVGA) 2 additional slots available for the phase noise system hardware. 1 ISA slot for PC Digitizer 1 PCI slot for Interface Card Microsoft Windows 2000 Agilent 82350A Interface Card) Table 1-2 Connectors and Adapters Part Number Description Agilent 70420A Agilent 70420A Option 001 Agilent 70420A Option 201 Agilent 70422A 1250-0207 BNC, 50 ohm Termination 1 1 1 1250-0780 Adapter, N(m) - BMC(f) 3 2 3 1 1250-1250 Adapter, N(m) - SMA(f) 1 2 1250-2015 Adapter, SMA(f) - BNC(m) 1 5061-5311 Adapter/Saver, 3.5mm(f) - 3.5mm(f) 2 2 1250-1200 Adapter, SMA(m) - BNC(f) 2 Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-3

1 E5500B Phase Noise Measurement System Unpacking Your System Unpacking Your System 1 Unpack and inspect the shipping container and its contents thoroughly to ensure that nothing was damaged during shipment. NOTE: If the container or packing material is damaged, the contents should be checked both mechanically and electrically. If the contents are damaged or defective, contact your nearest Agilent Technologies Sales and Service office. Keep the shipping materials for the carrier s inspection. 2 Verify that all parts and materials were included in the shipping container: E5500 Phase Noise Measurement System CD-ROM E5500 Software Keyword Licence Certificate E5500B Installation Guide (part no. E5500-90022) E5500A/B User s Guide (part no. E5500-90024) 9300-1408 Disposable Grounding Strap (Option 1FF) 5957-4369 Electrostatic Discharge (ESD) Warning Pamphlet PC Digitizer Card (Option 1FF) 1-4 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Hardware Installing the Hardware NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. CAUTION: Refer to your computer s documentation for installation safety instructions and specific instructions for opening your computer. Preparing for Installation 1 Power down the computer and all its peripherals. 2 Disconnect the power cord from the computer. 3 Remove the cover from the computer. This gives access to the I/O slots. See the computer documentation for detailed instructions. Accessing Your Computer s Expansion Slots 1 Look for suitable expansion slots for both the and PC Digitizer cards and remove the back panel s cover plates. Choose slots that give good access to the and PC Digitizer connectors. Figure 1-1 shows a view of the expansion slots vertically mounted; your computer s expansion slots may be horizontally mounted, but the process is the same Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-5

1 E5500B Phase Noise Measurement System Installing the Hardware. Figure 1-1 Vertically-mounted Expansion Slots Taking ESD Precautions CAUTION: To prevent possible ESD damage, you must be properly grounded with a grounding wrist strap before touching the PC Digitizer or (customer supplied) Interface Cards. While inserting the cards, be sure to hold the cards by their edges. 1 Using the disposable grounding strap, supplied with the PC Digitizer interface card, unwrap the first two folds of the wrist strap and wrap the exposed adhesive side firmly around your wrist. CAUTION: Wear this grounding wrist strap before unpacking or touching the PC Digitizer or interface cards; it is provided for control of static electricity. Failure to use the grounding wrist strap properly can result in damage to electronic devices and assemblies. 2 Unroll the rest of the wrist strap and peel the liner from the copper foil at the opposite end. 3 Attach the copper foil to a convenient and exposed electrical ground somewhere on the computer s chassis. This should be an unpainted surface of the computer cabinet. 1-6 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Hardware Figure 1-2 Use Grounding Straps Before Handling Cards Installing the Interface Card 4 Insert the interface edge connector into the expansion slot connector of the computer. Make sure the interface is fully seated by pushing firmly on the edge of the card with the palm of your hand. The connector should extend through the back panel opening to allow cable installation. NOTE: You may need a connector extender to provide adequate clearance between the cable and the computer chassis. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-7

1 E5500B Phase Noise Measurement System Installing the Hardware Figure 1-3 Inserting Card 5 Replace the back-panel cover plate screw to hold the interface in place. (Save the blank cover plate for use if the interface is removed later.) 1-8 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Hardware Installing the PC Digitizer Card 1 Verify the jumper and DIP switch settings shown in Figure 1-4 prior to installing the PC Digitizer card. Figure 1-4 Jumper and DIP Switch Settings on the PC Digitizer Card 2 Insert the PC Digitizer card edge connector into the expansion slot connector of the computer. Make sure the card is fully seated by pushing firmly on the edge of the card with the palm of your hand. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-9

1 E5500B Phase Noise Measurement System Installing the Hardware Figure 1-5 Inserting PC Digitizer Card 3 Replace the PC Digitizer back-panel cover plate screw to hold the card in place. 4 Replace the computer s cover as described in you computer s documentation. 5 Connect the Digitizer Adapter (Figure 1-6) to the back of the PC Digitizer card. Figure 1-6 Digitizer Adapter Making System Connections 1 Connect the following cables between the PC Digitizer card and the Agilent 70420A Test Set: SMB (f) to BNC (m) cable between the PC Digitizer card adapter s input connector and the Agilent 70420A Test Set s front-panel <100 khz output connector. 1-10 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Hardware SMB (f) to BNC (m) cable between the PC Digitizer card adapter s output connector and the Agilent 70420A Test Set s rear-panel Noise Source Input connector. 2 Refer to Figure 1-7 and Figure 1-8 for examples of system interconnections: Figure 1-7 E5501B Connect Diagram Example Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-11

1 E5500B Phase Noise Measurement System Installing the Hardware Figure 1-8 E5502B/3B/4B Connect Diagram Example 1-12 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Agilent I/O Libraries Installing the Agilent I/O Libraries NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. NOTE: If you must re-install the Agilent I/O Libraries at a later date, you must also re-install the E5500 Measurement Software after the I/O Library installation. 1 Make sure your computer and monitor are turned on. 2 Place the E5500 Phase Noise Measurement Software CD-ROM in the CD-ROM drive. 3 Double-click on Agilent_IO_libs, then on setup.exe. Follow the instructions in setup.exe, accepting the default settings.do not restart your computer at this time. 4 Restart your computer at this time. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-13

1 E5500B Phase Noise Measurement System Configuring the Agilent I/O Libraries Configuring the Agilent I/O Libraries 1 Make sure your computer and monitor are turned on. 2 Referring to Figure 1-9, navigate to the I/O Config. Figure 1-9 Navigate to I/O Config 3 Double click on I/O Config. 4 When the I/O Config screen appears, select Auto Config. This action adds all configured interfaces. See Figure 1-10. 1-14 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Configuring the Agilent I/O Libraries 5 When Auto Config completes, select 0 in the Configured Interfaces field. Then press Edit at the bottom of the field. See Figure 1-10. The 82350 PCI Card Configuration dialog appears. Figure 1-10 I/O Config Screen 6 At the bottom of the 82350 PCI Card Configuration dialog, press Edit VISA Config... See Figure 1-11. The Show Devices dialog appears. Figure 1-11 Bring up Show Devices Dialog Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-15

1 E5500B Phase Noise Measurement System Configuring the Agilent I/O Libraries 7 In the Show Devices dialog, click Auto Add devices. See Figure 1-12. Figure 1-12 Make Selections in Show Devices 8 Also in the Show Devices dialog, deselect Identify devices at run-time. See Figure 1-12. 9 Press OK on each dialog until you have exited the I/O Config program. 10 Restart your computer at this time. 1-16 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the PC Digitizer Software Installing the PC Digitizer Software NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. 1 Make sure your computer and monitor are turned on. 2 Place the E5500 Phase Noise Measurement Software CD-ROM in the CD-ROM drive. 3 Double-click on PC_Digitizer, then on Setup.exe. See Figure 1-13. Follow the instructions in Setup.exe, accepting the default settings. NOTE: If you receive the following Warning/Error messages during setup, disregard them, and allow the setup.exe to complete the installation process. Error: String variable is not large enough for string, check the string declarations. Error 401. CreateService Error: mastr_nt could not be installed. Error 997. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-17

1 E5500B Phase Noise Measurement System Installing the PC Digitizer Software Figure 1-13 Navigate to Setup.exe NOTE: Do not restart your computer at this time. 1-18 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Installing the Measurement Software Installing the Measurement Software NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. 1 Make sure your computer and monitor are turned on. 2 Place the E5500 Phase Noise Measurement Software CD-ROM in the CD-ROM drive. The dialog box shown in Figure 1-14 appears. Figure 1-14 Contents of E5500 Phase Noise Measurement Software CD-ROM 3 Double click on Setup.exe. Follow the instructions in Setup.exe, accepting the default settings. 4 Restart your computer at this time. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-19

1 E5500B Phase Noise Measurement System Locating Documents that Support the E5500 Locating Documents that Support the E5500 1 Make sure your computer and monitor are turned on. 2 Place the E5500 Phase Noise Measurement Software CD-ROM in the CD-ROM drive. 3 Referring to Figure 1-15, navigate to Documents. You can view all documents that support the E5500 on-line using Adobe Acrobat Reader (supplied). Figure 1-15 Navigate to Documents 1-20 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System Using the Asset Manager to Configure your System NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. 1 Make sure your computer and monitor are turned on. 2 Place the E5500 Phase Noise Measurement Software CD-ROM in the CD-ROM drive. 3 Referring to Figure 1-16, navigate to the E5500 Asset Manager. Figure 1-16 Navigate to Asset Manager 4 To place the Asset Manager in non-demo mode, either deselect the DM icon in the tool bar, or deselect Demo Mode from the Options menu. See Figure 1-17. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-21

1 E5500B Phase Noise Measurement System Using the Asset Manager to Configure your System Figure 1-17 Deselect Demo Mode 5 Click OK. The Asset Manager can be invoked from within the phase noise measurement software. If Asset Manager is invoked from within the software, restart the software for any Asset Manager changes to take effect. 1-22 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System Configuring the Agilent 70420A Test Set 1 To configure the Agilent 70420A Phase Noise Test Set using the Asset Manager Asset Wizard, select the Asset Wizard button from Auto Asset Wizard. See Figure 1-18. Figure 1-18 Start Asset Wizard 2 From the Asset Type pull-down list, select Test Set, then click the Next button. See Figure 1-19. Figure 1-19 Choose Asset Type 3 In the Choose Supporting ACM box, click on the Agilent 70420A, then select Next. 4 In the Select Interface and Address box (Figure 1-20): a b c Select O From the Interface pull-down list. Type 20, the default address for the Agilent 70420A Phase Noise Test Set, in the Address field. Table 1-3 shows Agilent-used default device addresses. Use the default in the Library pull-down list. The Library does not apply to this example. It applies specifically to either the Agilent Technologies or the National interface cards. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-23

1 E5500B Phase Noise Measurement System Using the Asset Manager to Configure your System 5 Select Next. Figure 1-20 Choose the Interface and Address for the Agilent 70420A Table 1-3 Agilent-used Default Device Addresses Instrument Address Agilent 70420A Test Set 20 Agilent 70421A Downconverter 28 Agilent 70422A Downconverter 28 Agilent 70427A Downconverter 28 RF Analyzer 17 FFT Analyzer 18 Source # 1 19 Source # 2 23 Counter 3 Agilent E1430 VXI Digitizer 129 Agilent E1437 VXI Digitizer 192 Agilent E1420B VXI Counter 48 Agilent E1441 VXI Arb 80 CAUTION: If an address is a single digit address, for example (3), do not add a leading zero (03) to the address. The phase noise software treats these (3 and 03) as different addresses. 1-24 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System 6 In the Set Model & Serial Numbers box (Figure 1-21): a b Type Agilent 70420A in the Asset Name field. Type the serial number for your Agilent 70420A test set in the Serial Number (optional) field. 7 Select Next. Figure 1-21 Choose Model and Serial Number 8 You may type a comment in the Enter a Comment box (Figure 1-22). The comment associates itself with the asset you have just configured. Figure 1-22 Enter a Comment About the Configured Asset 9 Select Finish. The Asset Manager window appears. See Figure 1-23. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-25

1 E5500B Phase Noise Measurement System Using the Asset Manager to Configure your System The left pane shows either the demo mode, or in this case, a list of assets or asset roles. An asset is any piece of hardware (Agilent 70420A) that you want configured for system use. An asset role is the general category for hardware (test sets, downconverters, counters, for example). The right pane is information only. The information can be changed by double-clicking a specific asset. Figure 1-23 Asset Manager Main Screen Showing Configured Agilent 70420A Test Set You have just used the Asset Manager to configure the Agilent 70420A test set. The process for configuring any asset is essentially the same. Both the test set and PC Digitizer are required to perform the confidence test at the end of this chapter. 1-26 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System Configuring the PC Digitizer This procedure shows how to configure the PC Digitizer using Asset Manager Wizard from within the Asset Manager. This is the most common way to add assets 1 From Asset Manager click Asset, then click Add. See Figure 1-24. Figure 1-24 Add Assets 2 From the Asset Type pull-down list (Figure 1-25), select FFT Analyzer, then select Next. Figure 1-25 Choose Asset Type Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-27

1 E5500B Phase Noise Measurement System Using the Asset Manager to Configure your System 3 In the Choose Supporting ACM dialog, click on II PCI20428W-1, then click the Next button. See Figure 1-26. Figure 1-26 Select Supporting ACM 4 In the Select Interface and Address dialog: a b c Select PCI From the Interface pull-down list. Type 320, the default address for the II20428 PC Digitizer, in the Address box. Table 1-4 shows Agilent-used default device addresses. The Library pull-down list does not apply to this example. It applies specifically to either the Agilent or the National interface cards. Figure 1-27 Choose the Interface and Address for the PC Digitizer 1-28 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System Table 1-4 Agilent-used Default Device Addresses Instrument Address Agilent 70420A Test Set 20 Agilent 70422A Downconverter 28 PC Digitizer 320 RF Analyzer 18 Source 19 Counter 3 CAUTION: If an address is a single digit address, for example (3), do not add a leading zero (03) to the address. The phase noise software treats these (3 and 03) as different addresses. 5 Select Next. 6 In the Set Model & Serial Numbers box (Figure 1-28): a b Type II PCI20428W-1 in the Asset Name box. Type the serial number for your PC Digitizer in the Serial Number (optional) box. 7 Select Next. Figure 1-28 Choose Model and Serial Number Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-29

1 E5500B Phase Noise Measurement System Using the Asset Manager to Configure your System 8 From the Baseband Source pull-down list in the Select FFT Analyzer Options box, select (internal). See Figure 1-29. This designates the noise source on the PC Digitizer board as the noise source to be used for loop suppression verification. Figure 1-29 Select (internal) in Baseboard Source 9 Click the Next button. 10 You can type a comment in the Enter a Comment box (Figure 1-30). The comment associates itself with the asset you have just configured. Figure 1-30 Enter a Comment About the Configured Asset 11 Click the Finish button. The Asset manager window appears. See Figure 1-31. 1-30 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using the Asset Manager to Configure your System You have just used the Asset Manager to configure the PC Digitizer. The process you have used to configure both the Agilent 70420A and PC Digitizer is the same process you will use to add software controlled assets to the phase noise measurement software. Figure 1-31 Asset Manager Screen Showing Configured PC Digitizer Configuring the Agilent E4411A/B (ESA-L1500A) Swept Analyzer 1 To configure the Agilent E4411A/B Swept Analyzer, follow the same steps you used to configure the Agilent 70420A Test Set (refer to Configuring the Agilent 70420A Test Set on page 1-23). 2 In the Select Interface and Address box, use 8, the default address for the Agilent E4411A/B. Refer to Table 1-4. 3 Click Server, then click Exit to exit the Asset Manager. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-31

1 E5500B Phase Noise Measurement System Entering the License Key for the Phase Noise Test Set Entering the License Key for the Phase Noise Test Set Use this procedure to enter your keyword for your Agilent 70420A Phase Noise Test Set. NOTE: If you have ordered a preconfigured phase noise system from Agilent Technologies, skip this step and proceed to Starting the Measurement Software on page 1-35. 1 Make sure your computer and monitor are turned on. 2 Referring to Table 1-32, navigate to the E5500 Asset Manager. Figure 1-32 Navigate to E5500 Asset Manager 3 Click Options, and then click License Keys Figure 1-33. 1-32 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Entering the License Key for the Phase Noise Test Set Figure 1-33 Navigate to License Keys NOTE: The license key for your system is unique and may only be used with a specific Agilent 70420A Test Set serial number. The license key may be found both on your license-key document and in the file license_key.txt on the License_key floppy disk provided with your system. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-33

1 E5500B Phase Noise Measurement System Entering the License Key for the Phase Noise Test Set 4 Enter the license key for your Agilent 70420A Test Set and click the Set button. Use Licence_key.txt described in the next steps to facilitate entering your license key into the licensing dialog box. a Insert the E5500 License Key disk in the computer. b Using Notepad, load License_key.txt (Figure 1-34). Figure 1-34 License_key.txt c Highlight the keyword in the License_key.txt file and copy it to the dialog box as shown in Figure 1-35, then click the Set button. Figure 1-35 Copy Keyword into License Key Field 5 Start the measurement software ( Starting the Measurement Software on page 1-35). 1-34 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Starting the Measurement Software Starting the Measurement Software 1 Referring to Figure 1-36, navigate to the E5500 User Interface. Figure 1-36 Navigate to E5500 User Interface 2 The main measurement subsystem window appears (Figure 1-37). Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-35

1 E5500B Phase Noise Measurement System Starting the Measurement Software Figure 1-37 Main User Interface Screen 1-36 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Using Server Hardware Connections to Specify Assets for the Confidence Test Using Server Hardware Connections to Specify Assets for the Confidence Test 1 From the System menu, choose Server Hardware Connections. See Figure 1-38. Figure 1-38 Navigate to Server Hardware Connections 2 In the Server Hardware Connections dialog (Figure 1-39): a b Select Agilent 70420A from the Test Set pull-down list. Click the Check I/O button. A green check-mark should appear after the I/O check has been performed by the software. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-37

1 E5500B Phase Noise Measurement System Using Server Hardware Connections to Specify Assets for the Confidence Test NOTE: If a red circle with a slash appears, return to the Asset Manager (click the Asset Manager button) and verify that the Agilent 70420A and PC Digitizer are configured correctly (check that the license key has been entered correctly). Also check your system hardware connections. Click the Check I/O button for a re-check. c d From the FFT Analyzer pull-down list, select II PCI20428W-1. Click the Check I/O button. A green check-mark should appear after the I/O check has been performed by the software. From the Swept Analyzer pull down list select E4411A. Click the Check I/O button. A green check mark should appear after the I/O is completed. Figure 1-39 Select Test Set, FFT Analyzer, and Swept Analyzer NOTE: Selecting the three instruments ties those assets to the confidence test performed in the next step. 3 Close the Server Hardware Connections box. 1-38 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Running the Software Confidence Test Running the Software Confidence Test This measurement tests the Agilent 70420A Test Set s low-noise amplifier circuitry. The phase detectors are not tested. This measurement also confirm that the PC and test set are communicating with each other. 1 From the File menu, choose Open. 2. If necessary, choose the drive or directory where the file you want is stored. 3 In the File Name box, open Confidence.pnm. See Figure 1-40. Figure 1-40 Opening the Parameters Definition File The appropriate measurement definition parameters for this example have been pre-stored in this file. Table 1-4 lists the parameter data that has been entered for the Agilent 70420A Confidence Test example. Table 1-5 Parameter Data for the Agilent 70420A Confidence Test Example Step Parameters Data 1 Type and Range Tab Measurement Type Start Frequency Stop Frequency Minimum Number of Averages FFT Quality Swept Quality 2 Cal Tab Gain preceding noise input Baseband Noise (using a test set) 10 Hz 100E + 6 Hz (determined by analyzer used) 4 Fast Fast 0 db Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-39

1 E5500B Phase Noise Measurement System Running the Software Confidence Test Table 1-5 Parameter Data for the Agilent 70420A Confidence Test Example Step Parameters Data 3 Block Diagram Tab Noise Source 4 Test Set Tab Input Attenuation LNA Low Pass Filter LNA Gain DC Block PLL Integrator Attenuation Ignore out-of-lock conditions Pulsed Carrier 5 Graph Tab Title Graph Type X Scale Minimum X Scale Maximum Y Scale Minimum Y Scale Maximum Normalize trace data to a: Scale trace data to a new carrier frequency of Shift trace data by Trace Smoothing Amount Power present at input of DUT Test Set Noise Input 0 db 20 MHz (Auto checked) Auto Gain (Minimum Auto Gain - 14 db) Not checked 0 dbm Not checked Not checked E5500 Confidence Test Base band noise (dbv/hz) 10 Hz 100 E + 6 Hz 0 dbc/hz - 200 dbc/hz 1 Hz bandwidth 1 times the current carrier frequency 0 db 0 0 dbm 1-40 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Running the Software Confidence Test Beginning the Measurement 1 From the Measure menu, choose New Measurement. See Figure 1-41. Figure 1-41 Selecting a New Measurement 2 When the Do you want to perform a New Calibration and Measurement? prompt appears, click OK. 3 When the Connect Diagram dialog box appears, connect the 50Ω termination provided with your system to the Agilent 70420A Test Set s Noise Input connector. (See Figure 1-42.) Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-41

1 E5500B Phase Noise Measurement System Running the Software Confidence Test NOTE: Although the Connect Diagram (Figure 1-42) appears next on your screen, this diagram does not apply to running the confidence test. Use the diagram merely to show where to connect the 50Ω termination to the Agilent 70420A Test Set. 50Ω termination goes here. Figure 1-42 System Confidence Test Setup diagram 1-42 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

E5500B Phase Noise Measurement System 1 Running the Software Confidence Test Making the Measurement 1 Press the Continue key. Because you selected New Measurement to begin this measurement, the System starts by running the routines required to calibrate the current measurement setup. Figure 1-43 shows a typical baseband phase noise plot for an Agilent 70420A Phase Noise Test Set. Figure 1-43 Typical Phase Noise Curve for a System Confidence Test Congratulations You have completed a phase noise measurement. You will find that this measurement of the Agilent 70420A Phase Noise Test Set s low noise amplifier circuitry provides a convenient way to verify that the System hardware and software are properly configured for making noise measurements. Document Part No. E5500-90022Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 1-43

1 E5500B Phase Noise Measurement System Running the Software Confidence Test 1-44 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

2 Connect Diagrams E5501B Standard Connect Diagram, page 2-2 E5501B Opt. 001 Connect Diagram, page 2-3 E5501B Opt. 201 Connect Diagram, page 2-4 E5502B Standard Connect Diagram, page 2-5 E5502B Opt. 001 Connect Diagram, page 2-6 E5502B Opt. 201 Connect Diagram, page 2-7 E5503B Standard Connect Diagram, page 2-8 E5503B Opt. 001 Connect Diagram, page 2-9 E5503B Opt. 201 Connect Diagram, page 2-10 E5504B Standard Connect Diagram, page 2-11 E5504B Opt. 001 Connect Diagram, page 2-12 E5504B Opt. 201 Connect Diagram, page 2-13 Document Part No. E5500-90022 Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 2-1

2 Connect Diagrams E5501B Standard Phase Noise System OSCILLOSCOPE (Optional but Recommended) FREQUENCY COUNTER (Optional) NOTE: 70001A MAINFRAME 70420A STD TEST SET DUT To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable REFERENCE SIGNAL GENERATOR (Optional) E5500 Software License Key PC-Digitizer Card Digitizer Output E4411A SPECTRUM ANALYZER 70420A TEST SET 70420A Standard Test Set STATUS SIGNAL INPUT NOISE REF INPUT 50 khz-1600mhz 1.2-26.5 GHz 50 Ω 1V Pk 50 khz-26.5 GHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN RF ANALYZER PHASE DET OUTPUT MONITOR FROM TO DOWNCONVERTER DOWNCONVERTER ANALYZER ANALYZER OUT OF LOCK TUNE VOLTAGE <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS To DUT RF Output E4411A Spectrum Analyzer To PC Digitizer (Yellow Cable) To Oscilloscope or Counter Monitor To Reference Source DC Out Tune Voltage Figure 2-1 E5501B Standard Connect Diagram 2-2 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

Connect Diagrams 2 OSCILLOSCOPE (Optional) E5501B Opt. 001 Phase Noise System FREQUENCY COUNTER (Optional) NOTE: Indicates Optional Cable 70001A MAINFRAME 70420A OPT. 001 DUT To 70420A Rear Panel Noise Server Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable E5500 Software License Key PC-MXI Card Digitizer Output REFERENCE SIGNAL GENERATOR (Optional) E411A SPECTRUM ANALYZER 70420A Opt. 001 Test Set 70420A OPT 001 TEST SET DUT Source Input STATUS To Reference Source INPUT REF INPUT SIGNAL NOISE 50 khz-1600mhz 1.2-26.5 GHz 50 Ω 1V Pk E411A Spectrum Analyzer 50 khz-1600 MHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR mw SIGNAL 1.2-26.5 GHz To Oscilloscope or Counter Monitor ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK PC Digitizer Yellow Cable Figure 2-2 E5501B Opt. 001 Connect Diagram <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS DC Out Tune Voltage Document Part No. E5500-90022 Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 2-3

2 Connect Diagrams OSCILLOSCOPE (Optional) E5501B Opt. 201 Phase Noise System FREQUENCY COUNTER (Optional) NOTE: Indicates Optional Cable 70001A MAINFRAME 70420A OPT. 201 DUT To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable E5500 Software License Key PC-MXI Card Digitizer Output REFERENCE SIGNAL GENERATOR (Optional) E411A SPECTRUM ANALYZER 70420A Opt. 201 Test Set 70420A OPT 201 TEST SET DUT Source Input STATUS To Reference Source INPUT REF INPUT SIGNAL NOISE 50 khz-1600mhz 1.2-26.5 GHz 50 Ω 1V Pk E411A Spectrum Analyzer 50 khz-1600 MHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR mw SIGNAL 1.2-26.5 GHz To Oscilloscope or Counter Monitor ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK PC Digitizer Yellow Cable <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS DC Out Tune Voltage Figure 2-3 E5501B Opt. 201 Connect Diagram 2-4 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

Connect Diagrams 2 E5502B Standard Phase Noise System OSCILLOSCOPE (Optional but Recommended) FREQUENCY COUNTER (Optional) NOTE: 70001A MAINFRAME 70420A 70421A DUT To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable REFERENCE SIGNAL GENERATOR (Optional) E5500 Software License Key PC-Digitizer Card Digitizer Output E4411A SPECTRUM ANALYZER 70420A TEST SET 70420A STATUS 70421A Downconverter 70421A DOWNCONVERTER STATUS SIGNAL INPUT NOISE 50 Ω 1V Pk REF INPUT 50 khz-1600mhz 1.2-26.5 GHz INPUT SIGNAL +5- +15 dbm 6.6 Ghz OUTPUT RF ANALYZER 50 khz-26.5 GHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR ANALYZER VOLTAGE CONTROL IF AUX LO FROM TEST SET + 10 VOLTS MAX 5-1500MHz 1.8-6.6GHz FROM TO DOWNCONVERTER DOWNCONVERTER ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS 100 Ω/1.25 LPS To DUT RF Output E4411A Spectrum Analyzer To PC Digitizer (Yellow Cable) To Oscilloscope or Counter Monitor To Reference Source DC Out Tune Voltage To DUT RF Output Optional Cable Downconverted Output Figure 2-4 E5502B Standard Connect Diagram Document Part No. E5500-90022 Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 2-5

2 Connect Diagrams E5502B Opt. 001 Phase Noise System OSCILLOSCOPE (Optional but Recommended) FREQUENCY COUNTER (Optional) NOTE: Indicates Optional Cable DUT 70001A MAINFRAME 70420A OPT. 001 70421A To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable REFERENCE SIGNAL GENERATOR (Optional) E5500 Software License Key PC-Digitizer Card Digitizer Output RF SPECTRUM ANALYZER 70420A OPT. 001TEST SET 70420A Opt. 001 STATUS 70421A Downconverter 70421A DOWNCONVERTER STATUS SIGNAL INPUT NOISE 50 Ω 1V Pk REF INPUT 50 khz-1600mhz 1.2-26.5 GHz INPUT SIGNAL +5- +15 dbm 6.6 Ghz OUTPUT RF ANALYZER 50 khz-26.5 GHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR ANALYZER VOLTAGE CONTROL IF AUX LO FROM TEST SET + 10 VOLTS MAX 5-1500MHz 1.8-6.6GHz FROM TO DOWNCONVERTER DOWNCONVERTER ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS 100 Ω/1.25 LPS To DUT RF Output RF Spectrum Analyzer To PC Digitizer (Yellow Cable) To Oscilloscope or Counter Monitor To Reference Source DC Tuning Out Voltage Signal Input to be Downconverted Downconverted Output to Test Set Signal Input Figure 2-5 E5502B Opt. 001 Connect Diagram 2-6 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0

Connect Diagrams 2 E5502B Opt. 201 Phase Noise System OSCILLOSCOPE (Optional but Recommended) FREQUENCY COUNTER (Optional) NOTE: 70001A MAINFRAME 70420A OPT. 201 70421A DUT To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable REFERENCE SIGNAL GENERATOR (Optional) E5500 Software License Key PC-Digitizer Card Digitizer Output RF SPECTRUM ANALYZER 70420A Opt. 201 Test Set 70421A Downconverter 70420A Opt. 201 TEST SET 70421A DOWNCONVERTER STATUS STATUS SIGNAL INPUT NOISE 50 Ω 1V Pk REF INPUT 50 khz-1600mhz 1.2-26.5 GHz INPUT SIGNAL +5- +15 dbm 6.6 Ghz OUTPUT RF ANALYZER 50 khz-26.5 GHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR ANALYZER VOLTAGE CONTROL IF AUX LO FROM TEST SET + 10 VOLTS MAX 5-1500MHz 1.8-6.6GHz FROM TO DOWNCONVERTER DOWNCONVERTER ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS 100 Ω/1.25 LPS Figure 2-6 DUT Source Output RF Spectrum Analyzer PC Digitizer Yellow Cable To Oscilloscope or Counter Monitor E5502B Opt. 201 Connect Diagram To Reference Source DC Out to Tune Voltage Signal Input to be Downconverted Downconverted Output to Test Set Signal input Document Part No. E5500-90022 Ed. 1.0 E5500 Phase Noise Measurement System Version A.02.00 2-7

2 Connect Diagrams E5503B Standard Phase Noise System OSCILLOSCOPE (Optional but Recommended) FREQUENCY COUNTER (Optional) NOTE: 70001A MAINFRAME 70420A 70422A DUT To 70420A Rear Panel Noise Source Input SYSTEM PC CONTROLLER Digitizer Input Yellow Cable REFERENCE SIGNAL GENERATOR (Optional) E5500 Software License Key PC-Digitizer Card Digitizer Output E4411A SPECTRUM ANALYZER 70420A TEST SET 70420A STATUS 70422A Downconverter 70422A DOWNCONVERTER STATUS SIGNAL INPUT NOISE 50 Ω 1V Pk REF INPUT 50 khz-1600mhz 1.2-26.5 GHz INPUT SIGNAL +5- +15 dbm 6.6 Ghz OUTPUT RF ANALYZER 50 khz-26.5 GHz 0.01 Hz-100 MHz +15 dbm MIN +7 dbm MIN PHASE DET OUTPUT RF ANALYZER MONITOR ANALYZER VOLTAGE CONTROL IF AUX LO FROM TEST SET + 10 VOLTS MAX 5-1500MHz 1.8-6.6GHz FROM TO DOWNCONVERTER DOWNCONVERTER ANALYZER ANALYZER TUNE VOLTAGE OUT OF LOCK <100 khz <100 MHz 50 Ω 20mA MAX 100 Ω/1.25 LPS 100 Ω/1.25 LPS To DUT RF Output E4411A Spectrum Analyzer To PC Digitizer (Yellow Cable) To Oscilloscope or Counter Monitor To Reference Source DC Out Tune Voltage To DUT RF Output Optional Cable Downconverted Output Figure 2-7 E5503B Standard Connect Diagram 2-8 E5500 Phase Noise Measurement System Version A.02.00 Document Part No. E5500-90022 Ed. 1.0