How Quadrupole Size Affects Research

Similar documents
Quadrupoles have become the most widely used

GC/LC-MS: data acquisition rate and peak reconstruction

Agilent 7000 Series Triple Quadrupole GC/MS System

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Operation of CEBAF photoguns at average beam current > 1 ma

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Liquid Chromatography- Mass Spectrometer Manual

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Gas Analysis. Microvision 2 STABILITY, ACCURACY AND SPEED THE RGA YOUR PROCESS CAN RELY ON

GCxGC Comprehensive Two-Dimensional Gas Chromatography

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Software Operation Manual

Characterizing the Electro-Optic Properties of a Microfabricated Mass Spectrometer

Achieving More Efficient Data Review with OpenLAB CDS

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

PHI 5000 VersaProbe TM Operator s Guide

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Etching Part 2. Saroj Kumar Patra. TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

MCP Upgrade: Transmission Line and Pore Importance

HV/PHA Adjustment (PB) Part

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

MPI Cable Selection Guide

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

4.9 BEAM BLANKING AND PULSING OPTIONS

Detailed Design Report

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

PHOENIX Finds every leak. Now with an even fi ner nose.

New gas detectors for the PRISMA spectrometer focal plane

Preliminary Study on Radio Frequency Neutralizer for Ion Engine

Nuclear Instruments and Methods in Physics Research A

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

Mechanical Design of Recirculating Accelerator Experiments for Heavy-Ion Fusion

FASTFLIGHT-2 Digital Signal Averager. Exceptionally fast LC/TOF-MS or GC/TOF-MS data acquisition... with a simple USB-2 connection to your computer!

INITIAL TESTING OF THE 6 GHz, ALL-PERMANENT MAGNET, "VOLUME-TYPE" ECR ION SOURCE

R&S RT-ZM Modular Probe System

INSTALLATION REQUIREMENTS - THERMAL ANALYSIS & RHEOLOGY SYSTEMS

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

HIGH CURRENT IMPLANTER 200KeV - SERIES 1090 TECHNICAL DESCRIPTION

Effects of the cryogenics operational conditions on the mechanical stability of the FLASH linac modules

Sensopress LCD Special English

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab

Quad-to-quad correlated motion in FLASH

AIM INTRODUCTION SIMPLIFIED WORKFLOW

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

If you have questions or problems in providing anything described as Customer

Physics Requirements for the CXI Ion Time-of-Flight

Operating Instructions

CAEN Tools for Discovery

R&S RT-Zxx High-Bandwidth Probes Specifications

Approved by: / / R. Battaglia 12/16/2016

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

The Distortion Magnifier

Laboratory for Ion Beam Interactions Facilities Overview. Damir Španja

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

Magnum GCMS Training and Operating Instructions 02/07/2012 S.V.

Waters Synapt High Definition Mass Spectrometry System Quick Start Guide

P. Emma, et al. LCLS Operations Lectures

SPEAR 3: Operations Update and Impact of Top-Off Injection

Lecture 17 Microwave Tubes: Part I

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

Implementing a Proton Beam Scanning System within an Operating Clinical Facility

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

HD Review March 30, 2011 Franz Klein

Results of the June 2000 NICMOS+NCS EMI Test

XRD-DSC Sample Alignment (BB) Part

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Hall-B Beamline Commissioning Plan for CLAS12

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

4.4 Injector Linear Accelerator

R&S RT-Zxx High-Voltage and Current Probes Specifications

PulseCounter Neutron & Gamma Spectrometry Software Manual

CLIC Feasibility Demonstration at CTF3

Okta 1000, Roots pump without motor

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

Fluke 279 FC True-rms Thermal Multimeter

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Fig. 1. Hawk switch/load vacuum section in the standard configuration.

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Reciprocating Machine Protection

Summary of the 1 st Beam Line Review Meeting Injector ( )

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

Transcription:

Quadrupole Size Comparison APPLICATION NOTE NOTE How Quadrupole Size Affects Research Mass Spectrometry is one of the most widely used analytical techniques and the most common mass analyzer is the quadrupole. Quadrupole technology has been used for more than 50 years to separate masses in a variety of applications. However, when it comes to quadruple mass spectrometry, QMS, there are a lot of options for researchers to consider. Most of the options rely on one main factor, quadrupole size. The most common quadrupole is the 6 mm or ¼, which can be found in residual gas analyzers (), analytical tandem gas chromatograph / mass spectrometers (GC/MS), and even process gas analyzers. However, while 6 mm may be the most common it is not necessarily the best option for all applications. Because of this, Extrel manufactures three different sizes of quadruples including the 6 mm, 9.5 mm and Extrel s most popular quad size, the 19 mm (¾ ). Whether to pick a different sized quadrupole can be a confusing prospect for researchers new to QMS. Looking at the advantages of each quad will help a researcher choose the correct direction to take. Transmission, Sensitivity, Mass Range and Resolution are all factors that can vary based on the quadrupole size. One advantage of Extrel systems is that the RF/DC power supply has a set power output, which means that there are no additional power requirements when going between quad sizes. The same power supply can be used for all sizes. Figure 1. 19 mm quadrupole (left) versus a 9.5 mm quadrupole (right). PAGE 1» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON

Experimental Sensitivity (ma/torr) Sensitivity tests were conducted using a spherical vacuum chamber housing three separate mass spectrometer probes. The sampling method utilized a metering valve to provide a room air leak of approximately 5 x 10-6 Torr and measuring the nitrogen signal on m/z 28. This signal was resolved to nominal mass of a 1 amu width and tuned for maximum intensity. The baseline (with the ion source powered off) was subtracted from the signal, and the background chamber pressure subtracted from the sample pressure. Data was collected for approximately 30 seconds with the ion source powered on, followed by approximately 30 seconds with the ion source powered off. The following equation was used to calculate the sensitivity of each mass spec in ma/torr: Where: Isignal = Signal intensity (in mv) of m/z 28 with the ion source powered on Sensitivity ( ma Torr ) = (I signal I background ) Preamplifier Gain (P sample P background) %N 2 Ibackground = Signal intensity (in mv) of m/z 28 with the ion source powered off Preamplifier Gain = Gain resistor of the preamplifier (in Ω) Psample = Sample pressure (in Torr) Pbackground = Background chamber pressure (in Torr) %N2 = Partial pressure of nitrogen (in %) in the sample (78.08%) Mass Spec #1 (19 mm quad ) collected data scanning from m/z 27 m/z 29 using a requested scan rate of 0.5 seconds, combined with a 190 sample prescan. This led to 20 microscans of 50 samples/mass and a 0.481 actual scan time. All data was collected using the Faraday plate detector tied to the conversion dynode. Mass Spec #2 (9.5 mm quad ) collected data scanning from m/z 26 m/z 30 using a requested scan rate of 0.5 seconds, combined with a 100 sample prescan. This led to 20 microscans of 50 samples/mass and a 0.497 actual scan time. All data was collected using the Faraday plate. Mass Spec #3 (6 mm quad Extrel ) collected data scanning from m/z 23 m/z 34 using a scan speed of 500 samples/second, combined with 20 samples/amu. The probe s auto zero function was set to every sample. This led to approximately two second scan times. All data was collected using the Faraday plate. Transmission (%) Transmission tests were conducted using a spherical vacuum chamber (Extrel Serial No.: 01876) housing three separate mass spectrometer probes. The sampling method utilized a metering valve to provide a room air leak of approximately 5 x 10-6 Torr and measured the maximum ion signal while scanning from ions m/z 23 to 34. This signal was resolved to a nominal mass of a 1 amu width and tuned for maximum intensity. The resolution was decreased, uniformly over the scan range, until a minimum resolution was achieved without any peak overlap between nitrogen and oxygen signals. Data was collected for approximately 30 seconds using the low (open) resolution, followed by approximately 30 seconds with the high (closed), nominal resolution. The following equation was used to calculate the transmission of each mass spec in percent: PAGE 2» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON

Transmission (%) = Intensity A Intensity B 100% Where: IntensityA = Signal intensity (in mv) of the scan using nominal resolution (1-amu wide peaks) IntensityB = Signal intensity (in mv) of the scan using low resolution (maximum peak width prior to interference due to overlapping) Mass Spec #1 () collected data scanning from m/z 23 m/z 34 using a requested scan rate of 0.5 seconds, combined with a 190 sample prescan. This led to 8 microscans of 50 samples/mass and a 0.481 actual scan time. All data was collected using the Faraday plate detector tied to the conversion dynode. Mass Spec #2 () collected data scanning from m/z 23 m/z 34 using a requested scan rate of 0.5 seconds, combined with a 100 sample prescan. This led to a 9 microscans of 50 samples/mass and a 0.476 actual scan time. All data was collected using the Faraday plate. Mass Spec #3 (Extrel ) collected data scanning from m/z 23 m/z 34 using a scan speed of 500 samples/second, combined with 20 samples/amu. The probe s auto zero function was set to every sample. This lead to approximately two second scan times. All data was collected using the Faraday plate. Maximum Resolution (M/ΔM) High resolution testing was conducted using a spherical vacuum chamber (Extrel Serial No.: 01876) housing two mass spectrometer probes, Mass Spec #1 and Mass Spec #2, and a metering valve to bleed UHP Argon into the chamber. The testing was conducted on Mass Spec #3 using a cylindrical vacuum chamber and a 0.05, restrictive tubing, differentially pumped, inlet to bleed UHP Argon into the chamber. The pressure of argon was increased to achieve a chamber pressure of approximately 5 x 10-6 Torr. Argon was scanned at m/z 40, then the tune for each mass spec was optimized to achieve the highest resolution on the peak. The resolution is calculated by using the following equation: Resolution = M M Where: M = Mass of the ion measured in amu ΔM = Full width of the ion measured at half of the maximum intensity, in amu (Full Width Half Max) Mass Spec #1 () collected data scanning from m/z 39.7 40.3 amu using a requested scan rate of 1 second, combined with a 100 sample prescan. This led to 30 microscans of 500 samples/mass and 0.982 actual scan time. All data was collected using the electron multiplier detector. Mass Spec #2 () collected data scanning from m/z 39.7 m/z 40.3 using a requested scan rate of 1 second, combined with a 100 sample prescan. This led to 16 microscans of 1000 samples/mass and a 0.976 actual scan time. All data was collected using the electron multiplier detector. Mass Spec #3 (Extrel ) collected data scanning from m/z 39 m/z 41 using a scan speed of 500 samples/second, combined with 20 samples/amu. The probe s auto zero function was set to every sample. This led to approximately two second scan times. All data was collected using the Faraday plate. PAGE 3» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON

Results Sensitivity (ma/torr) with air leak background only Figure 2. Example of the milliamp per Torr test that is performed to quantify the general sensitivity of a gas analyzer. This example shows the background spectra taken versus the 1 x 10-6 Torr spectra taken once an air leak was added to the system. 19 mm Quad - 9.5 mm Quad 6 mm Quad Extrel I signal = 2084.25 mv I background = 0.15 mv Preamplifier Gain= 10 8 Ω P sample = 7.75 10 6 Torr P background = 6.5 10 7 Torr I signal = 4054.86 mv I background = 14.75 mv Preamplifier Gain= 10 9 Ω P sample = 6.01 10 6 Torr P background = 1.4 10 7 Torr I signal = 1.721 10 9 A I background = 2.364 10 13 A P sample = 6.31 10 6 Torr P background = 1.0 10 7 Torr %N 2 = 78.08 % %N 2 = 78.08 % %N 2 = 78.08 % Sensitivity: 3.76 ma/torr Sensitivity: 0.88 ma/torr Sensitivity: 0.35 ma/torr Table 1. Sensitivity values. Transmission (%) Figure 3. Representative spectra for the three quadrupole sizes used in the testing of total transmission of the systems. The signal is first optimized, then switched to RF only mode to measure the amount of signal lost compared to the amount of signal generated by the ionizer. 19 mm Quad 9.5 mm Quad 6 mm Quad Extrel Intensity A = 2144.78 mv Intensity B = 2959.80 mv Intensity A = 2761.03 mv Intensity B = 8192.02 mv Intensity A = 1.24 10 9 A Intensity B = 4.30 10 9 A Transmission = 72.5% Transmission = 33.7% Transmission = 28.8% Table 2. Transmission (%) values. PAGE 4» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON

Maximum Resolution (M/ΔM) Figure 4. Waterfall plot of the three quad size spectra for the mass range from mass 50 to 150. Figure 5. Waterfall plot of the three quad size spectra for the mass range from mass 150 to 300. (detailed) Figure 6. Waterfall plot of the and for the mass range of 300 to 500 amu. Note that the maxes out at 300 amu. Inset shows the signal and less than 1 amu resolution at 464 m/z for the. PAGE 5» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON

Figure 7. Comparison of resolution at mass 40 for Argon for the three quad sizes. 19 mm Quad 9.5 mm Quad 6 mm Quad Extrel 0.00838 amu (FWHM) 0.0125 (FWHM) 0.187 amu (FWHM) Resolution (m/δm )= 4773 Resolution (m/δm) = 3200 Resolution (m/δm) = 214 Table 3. Resolution values. Conclusion Quadrupole size has a direct effect on maximum resolution and transmission. A larger quad size results in better ion transfer and space to separate the ions more efficiently. When choosing a quadrupole size, a researcher should pick the largest quad for the necessary mass range for their research. One advantage to Extrel s systems is that the fixed frequency QPS allows for an incredibly stable signal and when necessary, easy switching between mass ranges on the quadrupoles by just changing one box. What Pole Size Do I Need? Total power is fixed for Extrel QPS RF generators. For a specific mass range, performance and resolution increases with increasing frequency. Due to the wide loading range of the Extrel QPS, capacitance is no longer an issue for Extrel quads. Only reduction by going with a larger quad size is a lower mass range for a set frequency. Conclusion: Go with the biggest quad for the necessary application mass range. www.extrel.com 412-963-7530 RAQ110A 2016 Extrel CMS, LLC. Extrel is a registered trademark of Extrel CMS, LLC. PAGE 6» APPLICATION NOTE» QUADRUPOLE SIZE COMPARISON