EMC Solutions Noise filtering

Similar documents
SURGE PROTECTIVE DEVICES

Kuhnke Technical Data. Contact Details

Process transmitter RMA422

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

I/A Series Hardware Fiber Optic LAN Converter

Generator protection relay

LONWORKS Fibre Optic Converter

02/11/2015

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LONWORKS Fibre Optic Router

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

GV2ME. Main. Device short name. Device application

OPTOTRONIC Intelligent

Fibre Optic Modem ODW-611

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

ODW-621. RS-232 Point-to-point applications

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Bulletin 190 IEC Modular Starter System

Fibre Optic Modem ODW-622

Contactors and Contactor Assemblies

LED Driver Linear / area fixed output

Modular pulse operated latching relay 16 A

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Filters for Power Lines (Low Leakage Current)

Datasheet - SRB301LC 24VAC/DC

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

GV2ME. Main. Device short name. Device application

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Series CT7N Bimetallic Overload Relays

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

15 Series - Dimmer

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Fibre optic router for TP/FT-10 LRW-112PP

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

AS09..S 3-pole Contactors - Spring Terminals

SURGE PROTECTIVE DEVICES

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Process Transmitter RMA 422

GV2P05. Main. Device short name. Device application

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

CAMTO LTD. Arc detecting system DC/AC

High performance circuit breakers

Rack mounted telephone- and leased line modem for industrial applications

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Datasheet - SRB-E-201ST

ABB i-bus EIB Universal dimmer 6155 EB for Installation

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DFLK-D37 SUB/S. Extract from the online catalog. Order No.:

There is a button to select either the AES/EBU or S/PDIF input for the D/A converter, which is located on the rear panel.

A V 50Hz / V 60Hz

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

16 A and 25 A power contactors with or without handle

LED Driver Compact dimming

PRINCIPLES AND APPLICATIONS

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Digital output modules

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

Figure 1: Device components

Capacitors and banks 50 Hz 0 400/415 V network voltage

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

The Art of Engineering

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

I Ex-protected connectors exlink I

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Capacitance Limit Detection nivotester FTC 420/421/422

IP Roombox. Hotel Room Management

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Multifunction Digital Timer


MKH 8060 Directional studio microphone

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

OT 100/ /700 P5

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Surge Protective Device

DVO700 P FIBRE OPTIC TRANSMITTER

Product range. Safety technique. Monitoring technique. Power electronics. Control technique. Time control technique. Installation technique

Level Measurement silometer FMC 420, FMC 423

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Power Circuit of a UL508A Panel. Typical UL489 Application

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

AC diagonal module Ø 200 mm

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Transcription:

Power & Signal Quality TRABTECH EMC Solutions Noise filtering

Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability of electrical systems, installations and devices. Phoenix Contact meets these requirements with the comprehensive TRABTECH product range. Specific solutions from surge protection, monitoring, device circuit breakers as well as EMC products offer a constant high power and signal quality for maximum availability. Surge protection Monitoring Device circuit breakers EMC solutions 2 PhoeNix CoNtaCt Services

Table of contents Power and signal quality with EMC solutions Interference voltage filters for power supply units and measurement signals Page 4 Combined interference suppression filters with type 3 surge protection Page 5 Interference suppression filters with 1-10 A nominal load current Page 6 Interference suppression capacitor with modular terminal block design Page 7 Reliable signals through interference suppression filters Mechanically or electronically triggered switching operations generate pulse-like and high frequency interference voltages. These voltages are spread unhindered through the network. All devices within this network are affected. Data errors, uncontrolled functions and system crashes occur in data processing devices in particular. Fluorescent lamps EDP systems Relay Mains switch Electrical tools 0.1 to 3 MHz 2 to 3 MHz 0.05 to 20 MHz 0.5 to 25 MHz 0.1 to 1 MHz Typical sources of conducted interference voltages The causes for high-frequency random voltages are numerous and occur in all conceivable fields. PhoeNix CoNtaCt 3

Interference voltage filters for power supply units and measurement signals Interference suppression filters reduce conductor-specific high-frequency interference voltages. Devices, particularly in the field of data processing or automation, benefit from a clean power supply. Reliable operation as well as reliable measurement is the result. With floating remote indication contact SURGE FILTER PROTECTION Nominal voltage U N Phases Nominal load current I L Nominal frequency f N Nom. discharge surge current I N (8/20)μs Protection level U P Backup fuse max. in acc. with IEC IEC categories EN type IEC 61643-1 EN 61643 UL 1449 Interference suppression filters Functional principle and operating area Functional principle of filter circuits L L PE X Y 1 PE Filtering symmetrical interferences Interference voltages can be filtered X between phase and neutral conductors. Y 2 N N Filtering asymmetrical interferences Relevant opposite, grounded interference Y 1 voltages can be filtered from phase to PE as well as from neutral conductor to PE. Y 2 COMBITRAB X Y Operating area of filters An attenuation curve diagram illustrates the effective workspace of interference suppression filters. According to the symmetrical or asymmetrical filter circuit, the respective frequency-dependent attenuation is legible. Nominal voltage U N Nominal frequency f N Nominal load current I L Nom. discharge surge current I N (8/20)μs Protection level U P Backup fuse max. in acc. with IEC IEC categories EN type Test standards 4 PhoeNix CoNtaCt

Combined interference suppression filters with type 3 surge protection SURGE FILTER PROTECTION DIN rail mountable interference suppression filter with integrated device protection, optical diagnostic and status indicator and floating remote indication contact. COMBITRAB Interference suppression filter including device protection with on/off switch, optical-acoustic signaling and potential terminal block. TERMITRAB Combination of interference suppression filter and surge protection for two signal wires with common reference potential. ae symmetrical: ( 100 khz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) ae symmetrical: ( 500 khz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) 10 10 6 6 SFP 1-20/230 AC SFP 1-5/120AC SFP 1-10/120AC SFP 1-15/120AC SFP 1-20/120AC Order No. 2859987 Order No. 2920667 Order No. 2920670 Order No. 2920683 Order No. 2856702 230 V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 20 A ( 40 C) 5 A ( 72 C) 10 A ( 62 C) 15 A ( 52 C) 20 A ( 40 C) 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 5 ka (L-N) 5 ka (L-PE) 3 ka (L-N) 3 ka (L-PE) 1 kv (L-N) 1 kv (L(N)-PE) 450 V (L-N) 450 V (L(N)-PE) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) III T3 III T3 III T3 III T3 III T3 ae symmetrical: ( 1 MHz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) asymmetrical 50 Ω asymmetrical 150 Ω 10 10 6 6 CBT-4SFP-10 Order No. 2748386 230 V AC 50 Hz 60 Hz 10 A ( 40 C) 2.5 ka (L-N) 2.5 ka (L-PE) 650 V (L-N) 1 kv (L(N)-PE) 10 A (autom. 1-pos. thermal) III T3 IEC 61643-1 EN 61643-11/A11 EN 60939-2 TERMITRAB TT-ST-M-SFP Order No. 2858946 Nominal voltage U N Phases 24 V AC Nominal frequency f N 50 Hz 60 Hz Nominal load current I L 500 ma ( 55 C) Nominal discharge surge current I N (8/20)μs 350 A (L-PE) Protection level U P 80 V (C1 (500 V / 250 A)) (L-PE) Backup fuse max. in acc. with IEC 500 ma (e.g. T in acc. with 127-2/III) IEC categories EN type C1 C3 Test standards IEC 61643-21 PhoeNix CoNtaCt 5

Interference suppression filters with 1 to 10 A nominal load current FILTRAB are interference suppression filters for single-phase circuits, which limit both asymmetrical and symmetrical interference voltages. The ideal installation is directly before the device to be protected, as is valid for all filter devices. ae symmetrical: 65 db (1 MHz / 50 Ω) ae asymmetrical: 45 db (1 MHz / 50 Ω) ae symmetrical: 55 db (1 MHz / 50 Ω) ae asymmetrical: 35 db (1 MHz / 50 Ω) 10 10 6 6 FILTRAB NEF 1-1 NEF 1-3 Order No. 2794123 Order No. 2794110 Nominal voltage U N 240 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 1 A ( 40 C) 3 A ( 40 C) Backup fuse max. in acc. with IEC 1 A (gl) 3 A (gl) Test standards IEC 60939-2 EN 60939-2 IEC 60939-2 EN 60939-2 ae symmetrical: (1 MHz / 50 Ω) ae asymmetrical: (1 MHz / 50 Ω) ae symmetrical: 55 db (1 MHz / 50 Ω) ae asymmetrical: 35 db (1 MHz / 50 Ω) 10 10 6 6 FILTRAB NEF 1-6 NEF 1-10 Order No. 2783082 Order No. 2788977 Nominal voltage U N 240 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 6 A ( 40 C) 10 A ( 40 C) Backup fuse max. in acc. with IEC 6.3 A (gl) 10 A (gl) Test standards IEC 60939-2 EN 60939-2 IEC 60939-2 EN 60939-2 6 PhoeNix CoNtaCt

Interference suppression capacitor with modular terminal block design TERMITRAB series filters are feed-through modular terminal blocks with an interference suppression capacitor between the clamping part and DIN rail. The attenuation acts between signal and ground. A separate PE connection is also available. asymmetrical 50 Ω: 500 khz, typical asymmetrical 150 Ω: 100 khz, typical asymmetrical 50 Ω: 2 MHz, typical asymmetrical 150 Ω: 550 khz, typical 10 10 6 6 TERMITRAB TT-SLKK 5-C 12N-230AC TT-SLKK 5-C 3N3-230AC Order No. 2748069 Order No. 2798792 Nominal voltage U N 230 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 34 A ( 45 C) 34 A ( 45 C) Capacity (conductor-ground) 12 nf 3.3 nf Test standards VDE 0565-1 VDE 0565-1 Accessories: Spacer plate (2.5 mm height adjustment) DP-UKK 3/5 BK, Order No. 2770833 DP-UKK 3/5 BK, Order No. 2770833 Accessories: End cover D-UKK 3/5 BK, Order No. 2770228 D-UKK 3/5 BK, Order No. 2770228 Accessories: Labeling TRABTECH catalog, p. 123 TRABTECH catalog, p. 123 3 A perfect team for high power and signal quality Interference suppression filters (1) are an important measure to increase availability. Devices for residual current monitoring (2) and professional lightning and surge protection (3) increase availability to a maximum. 1 2 Additional information can be found at: www.phoenixcontact.com PhoeNix CoNtaCt 7

Further information on the products presented here and on the world of solutions from Phoenix Contact can be found at www.phoenixcontact.net/catalog Modular Terminal Blocks CLIPLINE 1 Marking Systems, Tools, and Mounting Material CLIPLINE 2 Or contact us directly. Connection Technology for Field Devices and Field Cabling PLUSCON Device Connection Technology and Electronic Housings COMBICON PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg, Germany Phone: +49/52 35/3-00 Fax: +49/52 35/3-4 12 00 www.phoenixcontact.com Automation Components and Systems AUTOMATION Power and Signal Quality TRABTECH Signal Converters, Switching Devices, Power Supply Units INTERFACE MNR 52005658/15.03.2012-01 Printed in Germany PHOENIX CONTACT 2012