InterReach Fusion Data Sheet

Similar documents
Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

1/3 RACK-MOUNTED BLOCK CONVERTERS

MULTIBAND 1/3 RACK-MOUNTED

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Synthesized Block Up- and Downconverter Indoor / Outdoor

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

15dBm Triband Indoor Band Selective Repeater for Multiple Networks, Frequency Agile with Fixed Bandwidth

Synthesized Block Up- and Downconverter

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

HexPort Multi-Band Antenna

SATCOM FIBER OPTIC PRODUCTS

Multiple Band Outdoor Block Up- and Downconverters

SYNTHESIZED COMMUNICATION CONVERTERS

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

DVO700 P FIBRE OPTIC TRANSMITTER

5100 Series IF Fiber Optic Links

ODW-621. RS-232 Point-to-point applications

Fibre Optic Modem ODW-611

Broadband Quadplexer Combiner

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

RIU-Lite and RIU-IM. features and benefits. A Corning MobileAccess Solutions Product

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

R-1580A Microwave Downconverter. Product Brochure

Truck router (3Gbps/HD/SD/ASI)

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

HDO750 OPTICAL AMPLIFIER FAMILY

HDMI Over Single Coax Extender

Multicom Optical Return Path Receiver MUL HRPR 4B

HDO701 FIBRE OPTIC TRANSMITTER

FLEXWAVE PRISM DIGITAL DISTRIBUTED ANTENNA SYSTEM

RF Semiconductor Test AXRF RF Port Upgrade Kits

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Optical Component Environmental Test System

Satellite Up- and Downconverter

DA E: Series of Narrowband or Wideband Distribution Amplifiers

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

HDMI Over IP Extender Kit - 4K

Satellite Up- and Downconverter Indoor / Outdoor

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

Fibre Optic Modem ODW-622

X-Band Redundant LNB Systems

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

L-Band Block Up- and Downconverter Indoor / Outdoor

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps

Datasheet. Carrier Backhaul Radio. Model: AF-2X, AF-3X, AF-5X. Up to 687 Mbps Real Throughput, Up to 200+ km Range

FORWARD PATH TRANSMITTERS

OmniStar GX2 Headend Optics Platform

ED5229GT-E Series. Page 1 of 8

TEST REPORT FROM RFI GLOBAL SERVICES LTD

ED5229GT-E/GTRE Series

JD725A Cable and Antenna Analyzer - Dual Port

High-Value 100 Series (Outdoor)

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

PiMPro Rack Mount Analyzer

ELECTRICAL TESTING FOR:

Rack mounted telephone- and leased line modem for industrial applications

SPECIFICATION. Part No. : MA140.A.LB.001

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

AMIGO- 8VSB (ATSC) digital Modulator

PiMPro Portable Analyzer PiMPro Classic 1821

TEST REPORT No

OPTICAL DISTRIBUTION STATION -

Dish Diversity Switch

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

LYNX ULTRA Series Hubs and Baluns

Typical applications:

Cellular Signal Booster

Ku-Band Redundant LNB Systems

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

The Art of Engineering

ThinkRF D GHz RF Downconverter

FiberLink 7142 Series

DA : Series of Narrowband or Wideband Distribution Amplifiers

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

C-Band Redundant LNB Systems

2W SDARS ECHO Repeater

Prisma Optical Networks Ancillary Modules

VGA & Audio over CAT5 Distribution Series

Compact EGC Fiber Deep Nodes A90100 and A90300

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband

XCOM1002JE (8602JE) Optical Receiver Manual

In-Line or 75 Ohm In-Line

Datasheet. Licensed Backhaul Radio. Models: AF-11FX-L, AF-11FX-H. Full-Duplex, Point-to-Point Radio. 11 GHz Frequency Operation

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

Broadcast Satellite Modulator

Transcription:

In-Building Wireless Networking System InterReach Fusion offers the same superior performance as Unison in a multiband, easy-to-install, economical package. It is ideal for mid-sized to large installations containing dense, high-traffic environments such as convention centers, sporting arenas and airports. Fusion InterReach Fusion features an easy-to-deploy Double-star architecture with just three types of components: A Main Hub that receives its radio frequency (RF) signals from a FlexWave Focus system, a base station or a repeater; up to 4- Hubs that connect to the Main Hub via singlemode or multimode fiber optics; and up to 32- Remote Access Units (RAUs) that connect to the Hub via CATV cabling. Each RAU sends and receives RF signals to wireless devices located within its coverage area. Administration is web-based. PRODUCT HIGHLIGHTS More than 20,000 TE distributed antenna systems shipped to more than 150 countries SingleStar One Port Option True multi-band system with single set of electronics cabling and dedicated capacity per band Delivers in-building wireless voice and data coverage over standard CATV cable Compatible with all major access protocols used worldwide including GPRS, EDGE, CDMA2000, WCDMA, and LTE Unparalleled RF performance featuring high output power, low noise, zeroloss distributed amplifier system that supports more channels and delivers the ability to cover large areas with a minimal amount of equipment Software-selectable hub frequencies, system gain, and antenna output power Requires no electrical power at the remote antennas Uses common CATV wiring for easy, non-disruptive installation Intelligent, web-based software-controlled operations, administration and maintenance capabilities support both on-site and remote configuration and monitoring Built-in system diagnostics constantly monitors system health

The Fusion Hubs are 19" rack mountable units. The plenum rated RAUs and the antennas connected to them are typically mounted in ceiling spaces throughout a facility. The main hub and expansion hub are connected using single mode or multimode fiber. The CATV cabling between the hub and each of the eight RAUs can be up to 130-150 meters (426-492 feet) long using 0.21 inch (5.5 mm) diameter RG-59 cabling. This length can be extended to 140-170 meters (459-557 feet) with use of RG-6 cabling, or to 235-275 meters (771-902 feet) using RG-11 cabling. Different cable types can be used simultaneously on a single hub. With a minimum of components and use of industry-standard 75 ohm CATV cabling, InterReach Fusion is simple and inexpensive to install, especially compared to heavy, inflexible, and invasive coaxial cabling. In addition, because power for the RAUs is provided over the CATV cabling, no local power is required, further simplifying installations. Multi-band RAU and Antenna CATV Cabling Multi-band BTS or Repeater InterReach Fusion Hubs Single or Multi-mode Fiber InterReach Fusion Main Hub FLEXIBLE OUTPUT LEVELS The system gain can be adjusted from 0 to 15 db in 1 db increments. In addition, the output of any individual RAU can be attenuated 0 or 10 db to provide controlled coverage in specific building areas. SYSTEM ARCHITECTURE The minimum configuration of a single Fusion system is one Main Hub, one Hub, and one RAU (1-1-1). The maximum configuration of a single system is one Main Hub, four Hubs, and 32 RAUs (1-4-32). Multiple systems may be deployed to cover larger areas or campus applications. ALARMING Fusion monitors over 170 parameters within the system. Three levels of alarms are available: LEDs: Each unit has LEDs to indicate a fault in the unit or a unit that is connected to it. For example, if an RAU has a fault its LED will light red, the fault information is sent to the Fusion Hub which also displays a red LED at the RAU s port connector. Contact Closures: Connect the Fusion Hub to a base station or external monitoring equipment. Status, Warning, and Fault messages: Displayed on a PC/laptop that is running a standard Internet Explorer browser or Standard Network Management System SNMP application software tools. Fiber Optic Cable Max. Length: 500 m multimode fiber 6 km singlemode fiber Coaxial Jumper (1-6'): RAU to Antenna Hub To/From Multi- Band Base Station or Repeater Fusion Main Hub Hub Hub Multi-band RAU Hub Up to 4 Hubs per Main Hub Up to 8 RAUs per Hub for a possible total of 32 RAUs 2

TYPICAL SPECIFICATIONS 700 MHz (Block Lower A, B, C) and 700MHz (Block Upper C) DOWNLINK UPLINK 700 MHz (Block Lower A, B, C) RF Frequency (full band): 728 to 746 MHz 698 to 716 MHz 700 MHz (Block Lower A, B, C) Bandwidth: 18 MHz 18 MHz 700 MHz (Block Upper C) RF Frequency (full band): 746 to 757 MHz 776 to 787 MHz 700 MHz (Block Upper C) Bandwidth: 11 MHz 11 MHz Spurious Emissions (dbm/30 KHz): < -13 800 MHZ AND 900 MHZ SMR DOWNLINK UPLINK 800 MHz RF Frequency: 851 to 869 MHz 806 to 824 MHz 800 MHz Bandwidth: 18 MHz 18 MHz 900 MHz RF Frequency: 935 to 941 MHz 896 to 902 MHz 900 MHz Bandwidth: 6 MHz 6 MHz iden (SQE): < 25 db < 25 db APCO 25 CQPSK (RMS EVM): < 6% < 6% APCO 25 C4FM (Mag Err RMS): < 5% < 5 % CDMA2000 (RHO): >0.99 >0.99 Spurious Emissions (dbm/100 KHz): < -13 850 MHz Cell DOWNLINK UPLINK RF Frequency (full band): 869 to 894 MHz 824 to 849 MHz Bandwidth: 25 MHz 25 MHz GSM (RMS Phase Error): < 2 < 2 EDGE (RMS EVM): 3% 3% CDMA2000 (RHO): > 0.99 > 0.99 WCDMA (RMS EVM): 5% 5% Spurious Emissions (dbm/100 KHz): < -13 900 MHz GSM DOWNLINK UPLINK RF Frequency (full band): 925 to 960 MHz 880 to 915 MHz Bandwidth: 35 MHz 35 MHz GSM (RMS Phase Error): < 2 < 2 EDGE (RMS EVM): 3% 3% Spurious Emissions (dbm): < -36 1800 MHz DCS DOWNLINK UPLINK RF Frequency (full band): 1805 to 1880 MHz 1710 to 1785 MHz Bandwidth: 75 MHz 75 MHz GSM (RMS Phase Error): < 2 < 2 EDGE (RMS EVM): 3% 3% Spurious Emissions (dbm): < -30 3

TYPICAL SPECIFICATIONS (CONTINUED) 1900 MHz PCS DOWNLINK UPLINK RF Frequency (full band: A-G)*: 1930 to 1995 MHz 1850 to 1915 MHz Bandwidth**: 65 MHz 65 MHz GSM (RMS Phase Error): < 2 < 2 EDGE (RMS EVM): 3% 3% CDMA2000 (RHO): > 0.99 > 0.99 WCDMA (RMS EVM): 5% 5% Spurious Emissions (dbm/mhz): < -13 * FSN-8519-1, FSN-W1-1921-1, and FSN-W2-808519-1 downlink RF frequency is 1930 to 1990 MHz and uplink RF frequency is 1850 to 1910 MHz. ** FSN-8519-1, FSN-W1-1921-1, and FSN-W2-808519-1 downlink and uplink bandwidth is 60 MHz. 2100 AWS DOWNLINK UPLINK RF Frequency (full band): 2110 to 2155 MHz 1710 to 1755 MHz Bandwidth: 45 MHz 45 MHz WCDMA (RMS EVM): 5% 5% Spurious Emissions (dbm/mhz): < -13 2100 MHz UMTS DOWNLINK UPLINK RF Frequency (full band): 2110 to 2170 MHz 1920 to 1980 MHz Bandwidth: 60 MHz 60 MHz WCDMA (RMS EVM): < 5% < 5% Spurious Emissions (dbm): < -30 2600 MHz DOWNLINK UPLINK RF RF Frequency (full band): 2620 to 2690 MHz 2500 to 2570 MHz Bandwidth: 70 MHz 70 MHz WCDMA (RMS EVM): 5% 5% Spurious Emissions (dbm): < -30 Standard Power 700-1000 MHz Typical Standard Power 1700-2700 MHz Typical High Power 1700-2700 MHz Typical Downlink Uplink Downlink Uplink Downlink Uplink Average gain with 150 m CATV at 25 C (77 F) (db) 1 : 15 15 15 15 20 1 15 Ripple with 150 m CATV (db): 2.5 3 3.5 4 3.5 4 Output IP3 (dbm): 38 38 43 2 Input IP3 (dbm): -5-5 -5 Output 1 db Compression Point (dbm): 26 26 31 3 Noise Figure 1 MH-1 EH-8 RAUs (db) 16 17 17 Noise Figure 1 MH-4 EH-32 RAUs (db) 22 23 23 1 FSN-W1-2118-1-HP downlink average gain is 18 db for 1800 MHz band, 20 db for 2100 MHz band. FSN-21HP-1 and FSN-W1-21HP-1 downlink average gain is 22 db. 2 FSN-21HP-1 and FSN-W1-21HP-1 output IP3 is 45 dbm. 3 FSN-21HP-1 and FSN-W1-21HP-1 output 1 db compression point is 33 dbm. 4

SPECIFICATIONS PHYSICAL MAIN HUB EXPANSION HUB REMOTE ACCESS UNIT IF/RF Connectors: 6 N, female (50 ohms), 1 Downlink/Uplink pair per band 8 F, female (CATV-75 ohms) 1 F, female (CATV-75 ohms) 1-2 N, female (antenna-50 ohms) External Alarm Connector (contact closure): 1 9-pin D-sub, female ADMIN/LAN Interface 1 RJ-45, female 1 RJ-45, female Connector: 1 9-pin D-sub, male for 1 9-pin D-sub, male optional modem Fiber Connectors 2 : 4 Pair, SC/APC 3 1 Pair, SC/APC AC Power (Volts): Rating: Rating: 54V DC (from the E Hub) 100-240V AC, 1A, 50-60 Hz 100-240V AC, 6A, 50-60 Hz over CATV Operating Range: 90-132V AC/ Operating Range: 90-132V AC/ 170-250V AC auto ranging 170-250V AC auto ranging DC Power (Volts): Operating Range: Operating Range: 38-64V DC, 2.5A 38-64V DC, 14A Power Consumption (W) 4 : 30 4 RAUs: 290 typical, 360 max 8 RAUs: 500 typical, 630 max Enclosure Dimensions 5 : 89 mm x 438 mm x 381 mm 89 mm x 438 mm x 381 mm 54 mm x 286 mm x 281 mm (height x width x depth) (3.5" x 17.25" x 15") 2U (3.5" x 17.25" x 15") 2U (2.13" x 11.25" x 11.13") Weight: <5.5 kg (<12 lb) <6.6 kg (<14.5 lb) <2.1 kg (<4.6 lb) CABLING Optical Fiber Optical Power Budget: CATV These specifications assume fiber optic cable, singlemode or multimode, with SC/APC connectors Uplink and Downlink Maximum: 3 db optical Optical power budget between Main Hub and Hub Optical loss = (fiber loss + connector losses + splice losses + patch cord losses) The specifications in this document assume that CATV RG-59 cable is Belden 1506A, CATV RG-6 cable is Belden 1695A, and CATV RG-11 cable is Belden 7732A or equivalent, with 75 ohm F connectors. CATV Lengths for Fusion Fusion Wideband ENVIRONMENTAL Minimum: 0 m (0'); Maximum: 150 m (492') with RG-59 Maximum: 170 m (557') with RG-6 Maximum: 275 m (902') with RG-11 MAIN HUB AND EXPANSION HUB Minimum: 0 m (0'); Maximum: 130 m (426') with RG-59 Maximum: 140 m (459') with RG-6 Maximum: 235 m (771') with RG-11 REMOTE ACCESS UNIT Operating Temperature: 0 to +45 C (+32 to +113 F) 25 to +45 C ( 13 to +113 F) Non-Operating Temperature: Operating Humidity; Non- Condensing: 20 to +85 C (-4 to +185 F) 25 to +85 C ( 13 to +185 F) 5% to 95% 5% to 95% 5 COMPLIANCE Safety: UL, CSA, CB Scheme certificate to IEC 60950, 3rd Edition, and IEC 60950-1, 1st Edition, with all national deviations EMC: FCC part 15 class A, EN 301 489-8, EN 301 489-23 Radio: FCC part 22, part 24, part 27, EN 300 609-4, EN 301 908-11, EN 301 908-15 Class 1 Laser Product: IEC 60825-1:1998-01 and IEC 60825-2:2000-05 1. The system gain is adjustable in 1 db steps from 0 to 15 db, and the Downlink or Uplink gain of each RAU can be attenuated 0 or 10 db. 2. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including fiber distribution panels. 3. FSN-1-MH-1P, FSN-2-MH-2-1P, FSN-W1-MH-2-1P, FSN-W2-MH-3-1P, FSN-W3-MH-1P, FSN-W4-MH-1P and FSN-W5-MH-1P supports only 1 pair, SP/APC fibers. 4. Fusion Hub typical power consumption assumes that the CATV RG-6 cable length is no more than 170 m and RG-11 is no more than 275 m. 5. Excluding angle-brackets for 19" rack mounting of hub.

Standard Power Output Power at RAU FSN-8518-1 FSN-8521-1 FSN-9018-1 FSN-9021-1 FSN-W1-2118-1 Power per Carrier (dbm) per Band RF Frequency Number of RF Carriers Downlink Uplink 1 P-out 2 P-out 4 P-out 8 P-out 850 Cell 869-894 824-849 15.0 12.0 9.0 6.0 CDMA 15.0 12.0 9.0 6.0 WCDMA 900 GSM 925-960 880-915 23.0 17.5 12.0 8.0 EDGE 1800 DCS 1805-1880 1710-1785 23.0 17.5 12.0 8.0 EDGE 15.0 12.0 9.0 6.0 LTE 2100 UMTS 2110-2170 1920-1980 15.0 12.0 9.0 6.0 WCDMA 15.0 12.0 9.0 6.0 LTE Standard Power Output Power at RAU Power per Carrier (dbm) per Band RF Frequency Number of RF Carriers Downlink Uplink 1 P-out 2 P-out 4 P-out 8 P-out 700 Upper C 746-757 776-787 700 Lower ABC 728-746 698-716 18.0 15.0 12.0 9.0 LTE 1 23.0 17.5 12.0 8.0 EDGE 850 Cell 869-894 824-849 18.0 15.0 12.0 9.0 CDMA FSN-8519-1 18.0 15.0 12.0 9.0 WCDMA FSN-809019-2 FSN-2-708519-1 16.5 13.0 9.0 5.5 iden FSN-2-758519-1 800 SMR 851-869 806-824 24.0 18.5 12.5 7.5 APCO 25 C4FM FSN-W1-1921-1 17.0 14.0 11.0 8.0 CDMA FSN-W2-808519-1 17.0 14.0 11.0 8.0 LTE FSN-W2-7021-1 900 SMR 935-940 896-901 14.5 11.0 7.0 3.5 iden FSN-W2-7070-1 23.0 16.5 10.5 5.5 APCO 25 C4FM FSN-W2-7575-1 FSN-W3-2626-1 23.0 17.5 12.0 8.0 EDGE 1900 PCS 2 1930-1995 1850-1915 18.0 15.0 12.0 9.0 CDMA 18.0 15.0 12.0 9.0 WCDMA 2100 AWS 2110-2155 1710-1755 18.0 15.0 12.0 9.0 WCDMA 2600 2620-2690 2500-2570 18.0 15.0 12.0 9.0 WCDMA 1 For FSN-W2-7021-1 RAU reduce each Power per Carrier by 4 db for 700 Lower ABC and 700 Upper C bands. 2 FSN-8519-1, FSN-W1-1921-1, and FSN-W2-808519-1 downlink RF frequency is 1930 to 1990 MHz and uplink RF frequency is 1850 to 1910 MHz. 6

High Power Output Power at RAU Power per Carrier (dbm) per Band FSN-2-708519-2-HP FSN-2-758519-2-HP FSN-W4-702121-1-HP FSN-W4-752121-1-HP FSN-W5-851921-1-HP FSN-21HP-1 FSN-W1-21HP-1 FSN-W1-2118-1-HP FSN-W1-2126-1-HP RF Frequency Number of RF Carriers Downlink Uplink 1 P-out 2 P-out 4 P-out 8 P-out 700 Upper C 746-757 776-787 700 Lower ABC 728-746 698-716 23.0 17.5 12.0 8.0 EDGE 850 Cell 869-894 824-849 18.0 15.0 12.0 9.0 CDMA 18.0 15.0 12.0 9.0 WCDMA 26.0 23.0 19.0 14.0 GSM 26.0 22.5 17.0 13.0 EDGE 1900 PCS 1930-1995 1850-1915 23.0 20.0 17.0 14.0 CDMA 23.0 20.0 17.0 14.0 WCDMA 2100 AWS 2110-2155 1710-1755 23.0 20.0 17.0 14.0 WCDMA 2100 UMTS 2110-2170 1920-1980 25.0 22.0 19.0 16.0 WCDMA 26.0 23.0 19.0 14.0 GSM 1800 DCS 1805-1880 1710-1785 26.0 22.5 17.0 13.0 EDGE 2100 UMTS 2110-2170 1920-1980 23.0 20.0 17.0 14.0 WCDMA 2600 2620-2690 2500-2570 23.0 20.0 17.0 14.0 WCDMA 7

ORDERING INFORMATION Band 850 1800 FSN-8518-1 850 1900 FSN-8519-1 850 2100 FSN-8521-1 900 1800 FSN-9018-1 900 2100 FSN-9021-1 2100HP FSN-21HP-1 RAU 800 900 1900 FSN-809019-2 700UC 850 1900 FSN-2-758519-1 Main Hub (AC) Main Hub (DC) Hub (AC) Hub (DC) FSN-1-MH-1 FSN-1-MHDC-1 FSN-EH-2 FSN-EHDC-2 700UC 850 1900 HP FSN-2-758519-2-HP FSN-2-MH-2 FSN-2-MHDC-2 FSN-EH-2 FSN-EHDC-2 700ABC 850 1900 FSN-2-708519-1 700ABC 850 1900 HP FSN-2-708519-2-HP 1900 AWS FSN-W1-1921-1 1800 2100 FSN-W1-2118-1 FSN-W1-MH-2 FSN-W1-MHDC-2 FSN-W1-EH-2 FSN-W1-EHDC-2 1800 HP 2100 HP FSN-W1-2118-1-HP 2100 HP FSN-W1-21HP-1 2100 HP 2600 HP FSN-W1-2126-1-HP FSN-W1-MH-3 N/A FSN-W1-EH-2 FSN-W1-EHDC-2 800 850 1900 FSN-W2-808519-1 700 ABC 700 UC AWS FSN-W2-7021-1 FSN-W2-MH-3 FSN-W2-MHDC-3 FSN-W1-EH-2 FSN-W1-EHDC-2 700 UC 700 UC FSN-W2-7575-1 700 ABC 700 ABC FSN-W2-7070-1 2600 2600 FSN-W3-2626-1 FSN-W3-MH-1 N/A FSN-W1-EH-2 FSN-W1-EHDC-2 700UC AWS HP AWS HP FSN-W4-752121-1-HP FSN-W4-MH-1 FSN-W4-MHDC-1 FSN-W1-EH-2 FSN-W1-EHDC-2 700ABC AWS HP AWS HP FSN-W4-702121-1-HP 850 1900 HP AWS HP FSN-W5-851921-1-HP FSN-W5-MH-1 N/A FSN-W1-EH-2 FSN-W1-EHDC-2 DATA SHEET Contact us: P.O. Box 1101 Minneapolis, Minnesota USA 55440-1101 Tel: 1-800-366-3891 Fax: 1-952-917-3237 www.te.com/wirelesssolutions TE Connectivity, TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks of the TE Connectivity Ltd. family of companies and its licensors. While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest dimensions and design specifications. Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. 314014AE 4/14 Revision 2014, 2013, 2012