Treefort Music Fest- March Festival Information Main Stage

Similar documents
Production Advance Information

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

Mics, DIs, Stands, and Cables

National Folk Festival PA Specs 2018 MARQUEE

SHOWBOX SODO TECHNICAL SPECIFICATIONS

Ed Blackwell Production Manager Mike Weller Head of Music

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

Thank you for thinking of The Fonda Theatre for your private event!

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Hard Rock Cafe Times Square Sound System Advance Sheet

MAJESTIC (Circus Tent)

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specifications

MAJESTIC (Circus Tent)

Section A: Front of House (FOH) Public Address (PA) Speaker System

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

7774 Sashabaw Road Clarkston, Michigan 48348

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Technical Specifications

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specification for the Alley Theatre, Strabane

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

UNIVERSITY CONCERT HALL. Technical Specification

Production Manager Shawn Dealey

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

$500 for configuration change, $1,200 for 1,800 capacity

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

PRODUCTION BIBLE. last update November 2015

Technical Specifications

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Lights. Carlos Leyva Cel: (619) (52)(664) Audio

Marjorie S. Deane Little Theater

Technical Pack. Attenborough Arts Centre

Technical Information

Concert Hall Technical Specifications

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Concert Hall Technical Specifications

Production Manager Shawn Dealey

TECHNICAL SPECIFICATIONS

MAIN STAGE GENERAL INFO AND FACILITIES

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

2016 Building and Production Specifications

Loading Dock / Van & Trailer / Bus Parking Same address. Pull to the back of the building to access loading docks and production lot.

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

FACT SHEET: MAIN STAGE

Technical Services and Specification

Little River Band Production Rider 2018

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

General & Technical Specifications

111 North 5 th Street Minneapolis, MN 55403

RIDER 2018 version 1 English

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

TOURING RIDER Where Magic & Motion Meet!

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Smothers Theatre Technical Specifications Pepperdine University

WE RE BACK CONCERT PACK UNSWROUNDHOUSE.COM

THE GEORGE WASHINGTON UNIVERITY LISNER AUDITORIUM. Thank you for your interest in The George Washington University, LISNER AUDITORIUM.

Project manager (PM): Pamela Næss Mail: Phone:

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

Technical Director of Production Andrew Quick Ext 252

General & Technical Specifications:

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Information for Incoming Companies

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

A Technical Guide to the Faith Center

Not Fade Away. The Ultimate Buddy Holly Experience. TECHNICAL RIDER Video Projection is Recommended

Laura Turner Hall Overview. Sound System Overview

City of Villa Rica 2016 Sound and Lighting. THE MILL amphitheater

TECH SHEET AND INFORMATION (Updated )

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

Sandusky State Theatre Technical Specifications

Barbican Concert Hall Sound System Spec

2018 Building and Production Specifications

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Theatre Technical Specifications

The adjudicator panel for the day will include Larry Carpenter, Jeanette Filardo, and Mariana Jones Meaders.

Complete guide Compiled January 2014

CARGO PRODUCTION GUIDE 2016

Main Stage Technical Specs - Hall #2

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

TECHNICAL RIDER GENERAL INFORMATION

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

VENUE HIRE INFORMATION

Transcription:

Treefort Music Fest- March 21-25 Festival Information Main Stage Venue Address: 1201 W. GROVE ST BOISE, ID 83702 On Site contacts: Glenn Thornton (Production Advance-FOH Production) gthornton@psiiusa.com Cole Calvin (Day of Show Contact) 208.867.6362 Jeni Rose (Artist Relations Manager) 541.601.9477 (texting preferred) Artist check in: Artist packets will be located second floor of the Owyhee Plaza (1109 Main Street). Please arrive during these hours only to pick up your artist wristbands and goodie bags! Wednesday 3/21: 2:00pm-8:00pm (Special locals check in please come check in early!) Thursday 3/22: 11:00am-10:00pm Friday 3/23: 11:00am-10:00pm Saturday 3/24: 12:00pm-10:00pm Sunday 3/25: 12:00pm-4:00pm Parking and Load-In: Load-in will be through 13 th Street entrance on the west end of parking lot (see overview map on page 3). Artist parking during your set is located in the parking lot adjacent to the venue on the corner of 13 th and Front St. (A1 Heating and Cooling Building). Please advance any large vehicles so we can make parking arrangements. Venue staff will direct you to the load in / staging area. After your set and load out please move your vehicle to street parking. Sound check: All sound checks will be festival line checks unless advanced with Glenn (FOH Production). Please arrive at the venue at least two hours prior to your set for load in. There is 30 minutes between each act for set up and line checks. Any time taken for set up and line checks over this time will cut into your set. Hospitality: The official artist hospitality area is located on the top floor of the Owyhee Plaza (1109 Main St). Throughout the weekend refreshments, snacks, and bar drinks will be served in this area and open to all performing artists (on the day of performance only please). There will also be a tented area next to the main stage with light hospitality as well as nearby food carts associated with the festival. Drink tickets for the artist lounge will be provided for you in your artist packet upon check in. Artist Lounge Hours: Wednesday: 5:00pm-12:00am Thursday: 4pm-12am Friday: 12pm-12am Saturday: 12pm-12am Sunday: 12pm-12am Merch: There will be a dedicated area for artist merchandise sales within the Main Stage area, and it is 80/20 Festival Sells split. Please bring your merch to the backstage and let Stacy, the backstage manager, know you are ready for a count it. Merch contract and Inventory Sheets can be found on the ARTIST FORTRESS (https://www.treefortmusicfest.com/artist-fortress/) Settlement: All artists receiving compensation must settle in our accounting office located second floor of the Owyhee Plaza during 10:00am-12:00pm (noon) and 5:00pm-10:00pm (please advance with Jeni Rose if this time does not work for you). All settlements will be in a check unless cash is requested prior to Monday, March 12, 2018 and all bands receiving compensation (over $500) will need to fill out a W9 (or W8) form. Thank you for being a part of Treefort! We look forward to a great show! For any questions, please feel free to contact Jeni Rose at artists@treefortmusicfest.com 541.601.9477

Treefort Music Festival Main Stage Technical Information Please advance all Production, sound checks, and backline with Glenn Thornton, gthornton@psiiusa.com (email preferred), 208.761.6513 Stage -Stageline SL 260 mobile stage, 32 wide x 24 deep main deck with 8 x 12 wings stage left. stage right and Audio - L Acoustics K2 main PA hang, (6) cabinets per side flown with (12) L Acoustics SB28 subwoofers ground stacked. L Acoustic 108p front fill. - (9) available monitor wedge mixes on (14) 115xt monitor wedges plus cue, stereo side fill and drum sub. (4) L Acoustics ARCS side fill over SB218. - Consoles Avid Venue D Show FOH console and AVID SC48 MON console. - Microphones (10) SM58, (10) SM57, (4) SM81, (1) SM91, (1) Audix D6, (1) MD421, (1) M88, (2) Audix SCX25, (5) Beta 98, (4) Sennheiser IEM - All necessary mic stands and cabling - (5) Countryman Type 85 direct box and (5) Radial J48 direct box. - Wireless (4) channels of Shure UHF-R - (4) channels Sennheiser G3 IEM. Lighting - (4) Martin Mac Aura - (6) Martin Mac 700 - (16) Martin Mac 101 - (8) HES Sola Spot 2k - (18) ETC Source 4 Par - (2) Mole crowd blinder - (1) ETC 2.4k 36ch dimmer - (1) Motion Labs 36 circuit moving light distro - (1) DF50 Hazer - (4) Source 4 Leko 26 - (1) Hog 4 full size console

117 4.1 118 4.61 119 4.121 120 4.181 108 3.85 109 3.97 121 4.241 122 4.301 123 4.361 124 4.421 107 110 3.73 700 Lbs 650 Lbs 3.109 106 3.61 111 3.121 105 3.49 112 3.133 104 3.37 113 3.145 103 3.25 114 3.157 102 115 3.13 3.169 101 3.1 250 Lbs 250 Lbs 116 3.181 Profile 16 6 Aura 4 HES Sola Viper Spot Profile 2k 8 ETC Source 4 18 PAR MCM (MFL) Mole-Richardson 2 TYPE 5541 1 2 5 6 1.1 1.2 1.5 1.6 19 7 10 1.7 1.8 1.19 1.22 1.14 8 14 2.1 2.187 1.3 2.32 2.212 2.63 2.94 2.237 2.125 2.262 2.156 701 301 3 702 302 1.9 703 704 303 705 1.15 304 9 706 15 1.4 485 Lbs 455 Lbs 4 1.16 1.10 1.11 11 1.12 12 22 1.13 13 16 1.17 17 1.18 18