Basic rules for the design of RF Controls in High Intensity Proton Linacs. Particularities of proton linacs wrt electron linacs

Similar documents
The FLASH objective: SASE between 60 and 13 nm

Digital BPMs and Orbit Feedback Systems

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

Detailed Design Report

Low Level RF for PIP-II. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017

RF considerations for SwissFEL

North Damping Ring RF

Modeling and simulation of longitudinal dynamics for Low Energy Ring-High Energy Ring at the Positron-Electron Project 1

Phase (deg) Phase (deg) Positive feedback, 317 ma. Negative feedback, 330 ma. jan2898/1638: beam pseudospectrum around 770*frev.

PoS(EPS-HEP2015)525. The RF system for FCC-ee. A. Butterworth CERN 1211 Geneva 23, Switzerland

4.4 Injector Linear Accelerator

PEP-I1 RF Feedback System Simulation

The PEFP 20-MeV Proton Linear Accelerator

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

CLIC Feasibility Demonstration at CTF3

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

BBU threshold current study for 6 GeV beam in 12 GeV beamline setup

PEP II Design Outline

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

ILC-LNF TECHNICAL NOTE

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

Karin Rathsman, Håkan Danared and Rihua Zeng. Report from RF Power Source Workshop

ANKA RF System - Upgrade Strategies

Status of the Longitudinal Emittance Preservation at the HERA Proton Ring in Spring 2003

KARA and FLUTE RF Overview/status

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

ECEN620: Network Theory Broadband Circuit Design Fall 2014

Lecture 3, Opamps. Operational amplifiers, high-gain, high-speed

RF Design of the LCLS Gun C.Limborg, Z.Li, L.Xiao, J.F. Schmerge, D.Dowell, S.Gierman, E.Bong, S.Gilevich February 9, 2005

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

RF Power Generation II

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

INFN School on Electron Accelerators. RF Power Sources and Distribution

HIGH-INTENSITY PROTON BEAMS AT CERN AND THE SPL STUDY

Bunch-by-bunch feedback and LLRF at ELSA

Feedback Control of SPS E-Cloud/TMCI Instabilities

EE273 Lecture 11 Pipelined Timing Closed-Loop Timing November 2, Today s Assignment

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Application Note 5098

Studies on an S-band bunching system with hybrid buncher

Karin Rathsman. Calculations on the RF Source and Distribution

RF Upgrades & Experience At JLab. Rick Nelson

A HIGH-POWER SUPERCONDUCTING H - LINAC (SPL) AT CERN

LIGHT PROTON THERAPY PROJECT

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

L-Band RF R&D. SLAC DOE Review June 15 th, Chris Adolphsen SLAC

Linac 4 Instrumentation K.Hanke CERN

Accelerator Instrumentation RD. Monday, July 14, 2003 Marc Ross

2 MHz Lock-In Amplifier

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

What can be learned from HERA Experience for ILC Availability

The FAIR plinac RF Systems

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Status of CTF3. G.Geschonke CERN, AB

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

INTRODUCTION. SLAC-PUB-8414 March 2000

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

The Elettra Storage Ring and Top-Up Operation

The LEP Superconducting RF System

Research and Development on Superconducting Radio-Frequency Technology for Electron Linear Accelerators. Deliverable

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Agilent 5345A Universal Counter, 500 MHz

High Rep Rate Guns: FZD Superconducting RF Photogun

PESIT Bangalore South Campus

Empirical Model For ESS Klystron Cathode Voltage

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

THE NEXT LINEAR COLLIDER TEST ACCELERATOR: STATUS AND RESULTS * Abstract

System Identification

Pulses inside the pulse mode of operation at RF Gun

LLRF at SSRF. Yubin Zhao

New Filling Pattern for SLS-FEMTO

Datasheet SHF A

ESS Linac WP8 Radio Frequency Systems and Test Facilities

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Status of RF Power and Acceleration of the MAX IV - LINAC

30 GHz Power Production / Beam Line

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

Cathode Studies at FLASH: CW and Pulsed QE measurements

Lecture 17 Microwave Tubes: Part I

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Driven Duffing Oscillator

PROJECT DESCRIPTION. Project Name. Broader Impact. Real Time Simulator for ILC RF and CryoModules

OPERATIONAL EXPERIENCE AT J-PARC

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

PEP-II longitudinal feedback and the low groupdelay. Dmitry Teytelman

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

Clock Jitter Cancelation in Coherent Data Converter Testing

The TESLA RF System. S. Choroba. for the TESLA Collaboration. DESY Notkestr. 85, D Hamburg, Germany

Activities on FEL Development and Application at Kyoto University

9th ESLS RF Meeting September ALBA RF System. F. Perez. RF System 1/20

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Asynchronous inputs. 9 - Metastability and Clock Recovery. A simple synchronizer. Only one synchronizer per input

CLIC Feasibility Demonstration at CTF3

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

Towards an X-Band Power Source at CERN and a European Structure Test Facility

4. ANALOG TV SIGNALS MEASUREMENT

Transcription:

Basic rules Basic rules for the design of RF Controls in High Intensity Proton Linacs Particularities of proton linacs wrt electron linacs Non-zero synchronous phase needs reactive beam-loading compensation Phase slippage (inside and outside cavities) larger sensitivity to cavity field fluctuations Different Dynamic properties of a given cavity family + phase slippage groups of multiple cavities driven by 1 common klystron can only be used at sufficiently high energy Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Basic rules Generic RF control scheme (SEL or GDR) M.O. Measurement V Ic = Re(V c )= V c cos φ c V Qc = Im(V c )= V c sin φ c V I c I Q V Q c Att. K I g I b Feedback loops -G I (V Ic -V Ir ) I Q -G Q (V Qc -V Qr ) Beam-loading compensation Cavity detuning ω ω = RQI sinφ V s c Phase shifter M.O. Generator driven Limiter Self-excited loop Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Basic rules Example of SEL scheme with analog control system implemented on SC cavity with non-relativistic beam (φ b = 3 ) = TTF capture cavity (Ein = 5 kev) Main features : self-excited loop (which ensures the cavity frequency tracking during the filling time) Cavity field controlled by means of I/Q modulator (during filling and beam-on time) starting phase of the self oscillator fixed by injection of a very low level signal klystron phase loop including a phase modulator to compensate any phase shift of the klystron.6 tests at DESY in February 1997 Eacc=1.5 MV/m, 6 ma Amplitude & phase errors : ± 4 1-4 & ±.1 peak-to-peak fluctuations mainly from high frequency noise (uncorrelated from cavity to cavity small effect on beam energy spread) Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Basic Model for Gain-Stability Considerations Control loops for field stabilization in cavity : real part loop and imaginary part loop Basic rules These loops can be considered as independent for the stability discussion, having the same transfer function. A simple representation can be found with several, but however realistic assumptions in the case of SC cavity : klystron and I/Q modulator bandwidths are much higher than that of the cavity, closest harmonic mode (5π/6 for SNS and 8π/9 for TESLA about 8 khz from the fundamental mode in both cases) is filtered out properly using HF pass-band filter and audio notch filter. Simple model for analog feedback TTF capt. Cav. For f LP = 4 khz, K = 18, F = 1.3 GHz, measurement and Q L = 3 1 6, the phase margin from the model is 86. High gain and good phase margin are allowed for proportional analog feedback Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Gain-Delay Discussion in Proportional Digital Feedback Control (Assuming : sampling period = delay) Basic rules Without low-pass filter With low-pass filter for noise reduction Open loop transfer function H analog (p) = K.e Z transform H digital Td p 1 e p (z) = z Td p ωcav p + ω cav ωcav Td ( e ) ωcav Td ( z e ) K 1 Roots of equation : 1 + H digital (z) = should lie inside the unity circle for stability of the closed loop. Limit of stability : T d 1 = ω cav K Ln K 1, with ω cav f = π Q L Open loop transfer function K 1 H(z) = z ( cav Td ) LP Td e 1 e T d ( z e cav d ) z e LP T Closed loop discrete transfer function H(z) (z) = = 1+ H(z) z G 3 a= K 1 b= c = e y n = a x n 3 b y a + b z + c z + d ωcav T ( e d ωlp )( 1 e ) T d ωcav T LP ( e d ω e ) T d +, ( ωcav + ωlp ) T d, d= K ( 1+ b+ c ) Recursion equation for time domain response n 1 c y, n dy n 3 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Gain-Delay Discussion in Proportional Digital Feedback Control Results for the case of SNS Basic rules 15 frequency = 85 MHz QL = 7e5 1 STABLE wo filter LP filter (35kHz) Without filter 5 UNSTABLE 4 8 1 16 Open Loop Gain K = 5, T d = 5 µs Phase margin = 4 w/o filter and 3 with filter Time response to a step excitation (on the right) With LP filter Stability could be more critical for digital feedback because of delay Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Basic rules Sampling of the measurement Bunch Trains are 945 ns spaced apart Systematic cavity voltage drop due to beam-loading 1-3 1 1-3 1 Vc / Vc continous measurement Better to sample field measurement Just before beginning of bunch train* In order to avoid systematic extra-power from feedback loops Even in absence of any perturbation * in case of digital system with delay, sampling time should be multiple of bunch train spacing -1 1-3 - 1-3..1-1 1-6 1 1-6 1-6 3 1-6 4 1-6 5 1-6 6 1-6 P / P (in-phase) sampled measurement Fast feedback loops (G=1) 1st medium-beta SNS cavity Beam current = 5 ma Chopper duty factor = 68 % -.1 -. -1 1-6 1 1-6 1-6 3 1-6 4 1-6 5 1-6 6 1-6 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Beam-loading compensation during beam pulse detuning angle such that cavity voltage looks real generator current and cavity voltage in phase φ c =φ g tan Ψ+Ysin φ b = V g = (1 + Y cosφ b ) V c steady-state regime with beam ( flat V c and φ c curves) during cavity filling One wants at fill end φ c =φ g whatever the detuning Automatically satisfied with SEL scheme Not the case for a pure GDR scheme I b Ψ φ b Basic rules I t V c /R I g 1. 1 Vc / Vco.8.6.4 φ c (deg). -.5 1-4 1.5 1-4 5 1-4 7.5 1-4 15 1 5-5 ( β + 1) P g = P g 4β [(1 + Y cosφ b ) + (tan Ψ+Ysinφ b ) ] beam - loading parameter Y = R LI b V c ω detuning angle tan Ψ=Q L ω Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations Simulation code = PSTAB initially developed for relativistic beams has been extended to low beta beams can handle all major field error sources (Lorentz forces, microphonics, input energy offsets, beam charge jitter, multiple cavities driven by one single power source, etc) includes feedback system and extra power calculation (+ delay for digital system) with N cavities driven by a common klystron, solves the 6xN coupled differential equations per power source : - 3 differential equations per cavity for beam-cavity interaction once the linac configuration has been defined (cavity types, number of cryomodules, design accelerating field and synchronous phase) a reference particle is launched through the linac in order to set the nominal phase of the field with respect to bunch at the entrance of all cavities - 3xN equations per klystron for cavity field dynamics of each resonator described by first order differential equations, plus another one modelling dynamic cavity detuning by the Lorentz forces beam-loading is modelled by a cavity voltage drop during each bunch passage with a magnitude varying from cavity to another (particle speed varies) To minimize the needed RF power : 1) Qex is set near the optimal coupling " 7.1 5 for SNS ) Cavity is detuned to compensate the reactive beam-loading due φ s? and fine tuning adjustement for minimizing Lorentz force effects Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Example of PSTAB simulations with SNS parameters Beam param eters *************** Peak Beam current(ma) : 5. Currentfluctuation (% ) :. Harm onic (Frf/Fb) :. Nb ofbunches /train : 6 Nb ofmissing bunches : 1 Nb ofbunch trains : 16 Cavity detuning for beam-loading compensation -1-14 -16-18 - f b (Hz) Linac D escription ***************** Starting Energy (MeV) : 185.6 Nb sectors : *** Sectorwith Cavity Type 1 Acc gradient(mv/m) : 1.11 Nb Cav /cryom odule : 3 Nb cryom odules : 11 Cavity spacing (m) :.51 Inter-cryom drift(m) :.775 Nb cavities /Klystron : 1 Beam phase standard (deg): -. *** Sectorwith Cavity Type Acc gradient(mv/m) : 1.56 Nb Cav /cryom odule : 4 Nb cryom odules : 15 Cavity spacing (m) :.48 Inter-cryom drift(m) :.866 Nb cavities /Klystron : 1 Beam phase standard (deg): -. Simulations - cavity index TotalNb cavities = 93 TotalNb klystrons = 93-4 4 6 8 1 systems were tested : analog (G=1) & digital (G=5 delay 4.7us) Linac Phasing ************* Sector Ending Energy = 185.6 Sector 1 Ending Energy = 388.56 Sector Ending Energy = 974.595 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations Lorentz forces effects In order to decrease RF power pre-detuning of the cavity (f res = f ope at approximately half the beam pulse) Total detuning = Sum of detunings for Lorentz forces + beam-loading compensation Lorentz forces only ( 8-4 Hz / [MV/m] ). Lorentz forces only ( 8-4 Hz / [MV/m] ). 1.1 1.1 φ (deg) E (MeV) φ (deg) E (MeV) -1 -.1-1 -.1-1 1 -...4.6.8.1 in-phase out-of-phase analog digital - 1 1 -...4.6.8.1 in-phase out-of-phase 8 8 P/P (%) 6 P/P (%) 6 4 4 klystron index klystron index 4 6 8 4 6 8 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations Additional microphonics effects With mechanical vibrations, feedback loops closed during the filling time, following pre-determined amplitude and phase laws, to ensure min RF power during beam pulse 4 Lorentz + µphonics (1 Hz).1 4 Lorentz + µphonics (1 Hz).1.5.5 φ (deg) E (MeV) φ (deg) E (MeV) - -.5 - -.5-4 15 -.1..4.6.8.1 in-phase out-of-phase analog digital -4 15 -.1..4.6.8.1 in-phase out-of-phase P/P (%) 1 P/P (%) 1 5 5 klystron index klystron index 4 6 8 4 6 8 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations Additional current fluctuation effect With random bunch charge fluctuation, the feedback system prevents from dramatic cumulative effects of several consecutive bunch charge errors Lorentz + charge fluctuation (5%).1 Lorentz + charge fluctuation (5%).1 1.5 1.5 φ (deg) E (MeV) φ (deg) E (MeV) -1 -.5-1 -.5-1 1 -.1..4.6.8.1 in-phase out-of-phase analog digital - 1 1 -.1..4.6.8.1 in-phase out-of-phase 8 8 P/P (%) 6 P/P (%) 6 4 4 klystron index klystron index 4 6 8 4 6 8 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

input beam offset With random energy and phase errors of the input beam ( ± 1 MeV ± 1 deg ) and assuming no fluctuations of the cavity fields the final energy and phase can not be smaller than 1.3 MeV and 6 deg. Simulations 1 E (MeV) input beam offset ( ± 1 MeV ± 1 deg ) with constant fields 6-1 1.3 MeV - φ (deg) -8-6 -4-4 6 8 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations SEL scheme analog system digital system (4.7 µs delay) E max (kev) φ max (deg) P/P I (%) P/P Q (%) Lorentz forces only 4.8.51. 9. 8-4 Hz/[MV/m] 17.1 1.61 1. 11. with µphonics A=1 Hz 17.8.53.3 16.1 Freq = 1 Hz 7.4 1.68 1.3 17.9 with µphonics A=1 Hz 4.7.43.3 15.3 Freq = 1 Hz 158.5 1.78 1.3 16.9 with tuning drift 1.3.54.3 16.6 ± 1 Hz (random) 57.6 1.75 1. 18.3 with charge fluctuation 46.5.59 4. 9.1 ± 5 % (random) 96.3 1.68 3.3 11.3 with input beam offset 133.7 6.14 5.9 11.6 ± 1 MeV ± 1 deg (random) 139. 6.76 4.1 11.1 multi-perturbation* 131. 6.5 7.8 18.5 145.5 7.1 5.7 18. * Lorentz forces + µphonics (Freq=1 Hz) + charge fluctuation + input beam offset Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations GDR scheme analog system digital system (4.7 µs delay) E max (kev) φ max (deg) P/P I (%) P/P Q (%) Lorentz forces only 5.7.51.5 8.7 8-4 Hz/[MV/m] 7.9 1.51. 9.4 with µphonics A=1 Hz 17.8.5.7 15.5 Freq = 1 Hz 96.3 1.56 3.1 15.7 with µphonics A=1 Hz 39.8.4.8 14.7 Freq = 1 Hz 165.3 1.6 3. 14.7 with tuning drift 1.6.54.8 16. ± 1 Hz (random) 48.4 1.63 3. 16.4 with charge fluctuation 46.6.59 4.3 8.8 ± 5 % (random) 18.3 1.58 4. 9.5 with input beam offset 134.1 6.14 6. 11. ± 1 MeV ± 1 deg (random) 133.5 6.7 5.1 9.4 multi-perturbation* 13.1 6.5 8. 17.9 147.1 7.5 7.4 15.6 * Lorentz forces + µphonics (Freq=1 Hz) + charge fluctuation + input beam offset Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Simulations Conclusion SEL scheme vs GDR scheme SEL requires smaller in-phase power and larger out-of-phase power (SEL keeps naturally the amplitude but shifts the phase) Analog vs digital generally digital with delay increases extra-power and errors unless total delay time " 1 µs for a random input beam offset : extra-power is slightly smaller but final errors are larger (because feedback can't follow with sudden changes) Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Multiple cavities per klystron Multi-cavity With relativistic electron beams, multiple cavities powered by a single power source easily controlled by the vector sum of the cavity voltages With proton beams, even when the vector sum kept perfectly constant individual cavity voltages can fluctuate with large amplitudes (phase slippage + change of dynamic behaviour of low-β cavities as energy ) We could however envisage to feed individually the cavities at the low energy part of the SC linac & to feed groups of cavities by common klystrons at the high energy part (lower phase slippages + closer dynamic cavity properties) For example, groups of 4 cavities only for high-β cavities in SNS Linac Simulations with spreads in Lorentz force detuning K % Hz / [MV/m] mechanical time constant τ m % cavity coupling Q ex % Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Multi-cavity Ex. Cavity voltages of 1st high-beta cryomodule (analog system G = 1).4 V/V 1st high-beta cryomodule Lorentz Forces ( Hz / [MV/m] ).4 V/V 1st high-beta cryomodule Lorentz Forces + spread in K, τ m, Q ex.. -. -. -.4 -...4.6.8.1 -.4 -...4.6.8.1 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Multi-cavity Lorentz forces & charge fluctuation (5%) effects Bunch energy deviations at beginning mainly induced by Qex spread Extra-power at end mainly induced by current fluctuations 1 Lorentz + charge fluctuation (5%).5 1.5.5 8 in-phase out-of-phase φ (deg) E (MeV) P/P (%) 6 4 -.5 -.5-1 -.5..4.6.8.1 klystron index 1 3 4 Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier

Multi-cavity SEL scheme analog system E max (kev) φ max (deg) P/P I (%) P/P Q (%) Lorentz forces only 418.6 1.6.8 4 - Hz/[MV/m] with µphonics A=1 Hz 688.93.5 6.4 Freq = 1 Hz with charge fluctuation 418.31 8.9.9 ± 5 % (random) with input beam offset 16 6.1 11.9 5.8 ± 1 MeV ± 1 deg (random) multi-perturbation* 1875 6.4 16.3 8.9 * Lorentz forces + µphonics (Freq=1 Hz) + charge fluctuation + input beam offset Low Level RF Controls for SC Linacs, JLab April 4-7, 1 M. Luong, A. Mosnier