mtdna Variant Analyzer v1.0 BaseSpace App Guide

Similar documents
STEVAL-SPBT2ATV2. USB Dongle for the Bluetooth class 2 SPBT2532C2.AT module. Features. Description

STEVAL-ISB008V1. Standalone USB Li-Ion battery charger demonstration board based on the STw4102 and STM32F103C6. Features.

STEVAL-ILL037V1. Demonstration board for the HVLED805 IC for LED power supply. Features. Description

STEVAL-ILL029V1. Front panel demonstration board based on the STLED325 and STM8S. Features. Description

ROBOT-M24LR16E-A. Evaluation board for the M24LR16E-R dual interface EEPROM. Features. Description

Obsolete Product(s) - Obsolete Product(s)

Black and Frozen Frame Detection

STEVAL-CCM003V1. Graphic panel with ZigBee features based on the STM32 and SPZBE260 module. Features. Description

Automated Limit Testing

March 2012 Doc ID Rev 1 1/4

EVALPM8803-FWD. EVALPM8803-FWD: IEEE802.3at compliant demonstration kit with synchronous active clamp forward PoE converter. Features.

Obsolete Product(s) - Obsolete Product(s)

STEVAL-CCA043V1. 25 Watt mono BTL class-d audio amplifier demonstration board based on the TDA7491MV. Features. Description

STEVAL-IHM043V1. 6-step BLDC sensorless driver board based on the STM32F051 and L6234. Features. Description

Obsolete Product(s) - Obsolete Product(s)

Obsolete Product(s) - Obsolete Product(s)

STEVAL-CCH002V2. HDMI and video switches demonstration board. Features. Description

Obsolete Product(s) - Obsolete Product(s)

SPC564A80CAL176 SPC564A70CAL176

STEVAL-IHM024V W 3-phase inverter using the L6390 and STGDL6NC60DI for vector control. Features. Applications. Description

STEVAL-ILH004V1. 70 W electronic ballast for metal halide lamp (HID) based on the L6382D5 and ST7FLITE49K2. Features. Description

L7208. Portable consumer electronics spindle and VCM motor controller. General features. Spindle driver. Description. VCM driver.

Order code Package Connection. SPDC400FC12M0.60 Open frame Comb. October 2007 Rev 1 1/9

PRODUCT INFORMATION LETTER

STEVAL-ICB004V1. Advanced resistive touchscreen controller demonstration board based on the STMPE811. Features. Description

STEVAL-IHM021V W, 3-phase inverter based on the L6390 and UltraFASTmesh MOSFET for speed FOC of 3-phase PMSM motor drives. Features.

IEC compliant smart meter system for AMI applications based on STM32, ST7570 PLM, and STPMC1/STPMS1 chipset

STEVAL-IKR001V7D. Sub Ghz transceiver daughterboard with power amplifier based on the SPIRIT1. Features. Description

STEVAL-ILL043V1. High end, 75 W high power factor flyback LED driver based on the L6562A with two dimmable strings. Features.

Obsolete Product(s) - Obsolete Product(s)

STEVAL-MKI126V2. MEMS microphone system evaluation board based on the STA321MPL and MP34DB01. Description. Features

STEVAL-ILH005V W electronic ballast for HID lamps based on the L6562A and ST7LITE39F2. Features. Description

STEVAL-MKI126V3. STSmartVoice demonstration board based on MP34DT01. Description. Features

TN0885 Technical note

STEVAL-IME002V1. Multi-lead electrocardiogram (ECG) and body impedance demonstration board. Features. Description

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

STEVAL-ILL015V1. High brightness RGB LED array with LED error detection based on the STP24DP05 and STM32. Features. Description

IMPORTANT NOTICE. Company name - STMicroelectronics NV is replaced with ST-NXP Wireless.

STEVAL-IFN003V1. PMSM FOC motor driver based on the L6230 and STM32F103. Features. Description

2 x 58 W high frequency ballast for T8 fluorescent tubes based on L6562A, L6569, and STL11NM60N in PowerFlat HV package

STM32-PRIMER/LAB. Raisonance EvoPrimer-LAB to monitor STM32 applications and standalone STM32 Flash programming. Features

Multi-channel LED driver with integrated boost controller for medium, large LCD panel backlight based on LED7708 and STM32F103C6T6A

How-To Guide. LQV (Luminance Qualified Vector) Measurements with the WFM8200/8300

STEVAL-ISA001V1. 6W Dual Output Supply using VIPer12A. Features. Blue angel. Applications

Main components Proximity and ambient light sensing (ALS) module

AN2421 Application note

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

M24LR04E-R, M24LR16E-R, M24LR64E-R Errata sheet

Spearhead Display. How To Guide

STW High voltage fast-switching NPN power transistor. Features. Application. Description

PRODUCT TERMINATION NOTIFICATION

STV6110A. 8PSK/QPSK low-power 3.3 V satellite tuner IC. Description. Features

STEVAL-IHM008V1. BLDC & AC motor control Power board SEMITOP 2 1kW. Features. Applications

PRODUCT INFORMATION LETTER

STANC0. Stereo HD-PA digitally programmable active noise cancelling audio engine. Features. System. Input and output.

Main components Proximity and ambient light sensing (ALS) module

STEVAL-TDR007V1. 3 stage RF power amplifier demonstration board using: PD57002-E, PD57018-E, 2 x PD57060-E. Features. Description

GM69010H DisplayPort, HDMI, and component input receiver Features Applications

GM60028H. DisplayPort transmitter. Features. Applications

AN3075 Application note

EVAL-RHF1009A. EVAL-RHF1009A product evaluation board. Description. Features

Mechanical specification. October 2010 Doc ID Rev 1 1/10

M24SR-DISCOVERY. Discovery kit for the M24SR series Dynamic NFC/RFID tag. Features

STEVAL-IHT005V2. Demonstration board with full 3.3 V ACS/Triac control using the STM32F100. Description. Features

Using Triggered Video Capture to Improve Picture Quality

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars

Bio-Rad Imaging Systems Family

Obsolete Product(s) - Obsolete Product(s)

Obsolete Product(s) - Obsolete Product(s) UM0223 User manual STEVAL-IFS001V1 evaluation kit with MEMS Introduction

GM68020H. DisplayPort receiver. Features. Applications

STV6417 R/C/Pr, G/C, B/Pb Switches + Filter. C, Y, CVBS/Y Switches + Filter. Audio Switches Volume Control AUDIO R SLOW BLANK

STEVAL-TDR020V1. Portable UHF 2-way radio demonstration board based on the PD84006L-E. Features. Description

STEVAL-ISA121V1. Wide range single-output demonstration board based on the VIPER37LE. Features. Description

BAL-NRF01D3. 50 ohm balun transformer for 2G45 ISM matched Nordic s chipset: nrf24le1 QFN32, nrf24ap2-1ch and nrf24ap2-8ch. Features.

STEVAL-ISA050V1. Monolithic VR for chipset and DDR2/3 demonstration board based on the PM6641. Features. Application. Description

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

VT5365. Single-chip optical mouse sensor for wireless applications. Features. Applications. Technical specifications. Description.

STEVAL-TDR021V1. Demonstration board using the PD84008L-E for 900 MHz 2-way radio. Features. Description

Installation Instructions. What This Option Provides

STEVAL-ILL019V1. 32 W offline RGGB LED driver with individual LED channel brightness regulation. Features. Description

WINDOWS GUIDE LIBRESTREAM.COM

PRODUCT/PROCESS CHANGE NOTIFICATION

STA3005. Dual-IF AM/FM digital radio receiver. Feature summary. Order codes

AN555 APPLICATION NOTE AUTOMOTIVE PROTECTION WITH THE RBOxx SERIES

FLI30x02 Single-chip analog TV processor Features Application

Agilent Understanding the Agilent 34405A DMM Operation Application Note

TA0311 TECHNICAL ARTICLE High Temperature Electronics 1 Introduction 2 Why the need for high-temperature semiconductors?

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

ST-LINK/V2 in-circuit debugger/programmer for STM8 and STM32

Cisco Spectrum Expert Software Overview

PAM4 Transmitter Analysis

Main components Narrow-band OFDM power line networking PRIME compliant system-on-chip

Recurring Events Guide

EVLHVLED815W8CV. 8 W - high power factor - constant voltage regulation based on HVLED815PF. Features. Description

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

X-Sign 2.0 User Manual

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

IoT Toolbox Mobile Application User Manual

Transcription:

mtdna Variant Analyzer v1.0 BaseSpace App Guide For Research Use Only. Not for use in diagnostic procedures. Introduction 3 Log In to BaseSpace 4 BaseSpace Projects Page Functions 5 Select Samples From a Project or Multiple Projects 6 Analysis Output 7 Technical Assistance ILLUMINA PROPRIETARY Doc # 1000000007934 v00 February 2016

This document and its contents are proprietary to Illumina, Inc. and its affiliates ("Illumina"), and are intended solely for the contractual use of its customer in connection with the use of the product(s) described herein and for no other purpose. This document and its contents shall not be used or distributed for any other purpose and/or otherwise communicated, disclosed, or reproduced in any way whatsoever without the prior written consent of Illumina. Illumina does not convey any license under its patent, trademark, copyright, or common-law rights nor similar rights of any third parties by this document. The instructions in this document must be strictly and explicitly followed by qualified and properly trained personnel in order to ensure the proper and safe use of the product(s) described herein. All of the contents of this document must be fully read and understood prior to using such product(s). FAILURE TO COMPLETELY READ AND EXPLICITLY FOLLOW ALL OF THE INSTRUCTIONS CONTAINED HEREIN MAY RESULT IN DAMAGE TO THE PRODUCT(S), INJURY TO PERSONS, INCLUDING TO USERS OR OTHERS, AND DAMAGE TO OTHER PROPERTY. ILLUMINA DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE IMPROPER USE OF THE PRODUCT(S) DESCRIBED HEREIN (INCLUDING PARTS THEREOF OR SOFTWARE). 2016 Illumina, Inc. All rights reserved. Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cbot, CSPro, CytoChip, DesignStudio, Epicentre, ForenSeq, Genetic Energy, GenomeStudio, GoldenGate, HiScan, HiSeq, HiSeq X, Infinium, iscan, iselect, MiniSeq, MiSeq, MiSeqDx, MiSeq FGx, NeoPrep, NextBio, Nextera, NextSeq, Powered by Illumina, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG, VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or its affiliate(s) in the U.S. and/or other countries. All other names, logos, and other trademarks are the property of their respective owners.

Introduction Using the analysis results from the mtdna Variant Processor App, the BaseSpace mtdna Variant Analyzer v1.0 App produces the analysis for mitochondrial DNA (mtdna) sequencing data. The app can analyze any part of the full circular genome, without any origin dead zone, using quality and coverage thresholds customized by the user. The app also generates analysis reports in Excel file format. Introduction Compatible Data The Variant Call Format (VCF) output files from the mtdna Variant Processor App are compatible with the mtdna Variant Analyzer App. Reference Genomes The genome for alignment is the Revised Cambridge Reference Sequence (rcrs), a mtdna genome used by the Forensic Genomics community. mtdna Variant Analyzer v2.0 App Guide 3

Log In to BaseSpace 1 Navigate to BaseSpace at basespace.illumina.com, enter your user name and password, and click Login. 2 Click the Apps tab. 3 In Categories, click Targeted Sequencing, and then click mtdna Variant Analyzer. 4 From the drop-down list, select version 1.0.0, and then click Launch to open the app. The permission request dialog box appears. 5 From the dialog box, click Accept. By default, this dialog box appears the first time you launch the app. After you click Accept, the BaseSpace Projects page appears. For additional training on BaseSpace, see the BaseSpace support page at support.illumina.com/sequencing/sequencing_software/basespace/training.html 4 Doc # 1000000007934 v00

BaseSpace Projects Page Functions You can perform the following functions while in the BaseSpace Projects page: } To search for a project, enter the project name in the search project name field. } To search for samples, enter a sample name in the search sample name field. } To remove a sample, click the selected sample again or click. } To select all samples, click the Select All Visible link. } To remove all samples, click Clear all. BaseSpace Projects Page Functions mtdna Variant Analyzer v2.0 App Guide 5

Select Samples From a Project or Multiple Projects 1 In the BaseSpace Projects page, select the project you want to analyze. 2 Select the samples you want to analyze. The app supports a maximum of 96 samples. The right-side pane shows the selected samples for analysis. 3 [Optional] To add samples from a different project, click BaseSpace Projects to return to the BaseSpace projects page. Repeat step 1 and 2. 4 When you have completed selecting the samples, click Submit. By default, the first time you select a sample, a dialog box requesting for access to samples in the project appears. 5 From the dialog box, click Accept The app reloads the selected samples. Any unsaved changes to samples are not loaded to the analysis. When analysis is complete, the app shows the sample analysis in the Reference Genome Compare View, mtdna Navigator, and Coverage Plot. 6 Doc # 1000000007934 v00

Analysis Output The mtdna Variant Analyzer App uses VCF and BAM output files from the mtdna Variant Processor App to produce the following analysis output: } Reference Genome Compare View } Sample Compare View } mtdna Navigator } Coverage Plot } Aggregate Analysis Report } Sample Analysis Reports Analysis Output Status Icons The mtdna Variant Analyzer App provides the following status icons. Table 1 Status Icon Table Icon Description In the BaseSpace Projects page, this icon at the topright of the sample indicates that the sample is modified. In the Reference Genome Compare View, this blue icon next to the sample indicates that the sample is modified. In the Sample Compare View, the icon color is orange. In the Reference Genome Compare View, this blue icon next to the sample name indicates that the sample changes are unsaved. In the Sample Compare View, the icon color is orange. Reference Genome Compare View The Reference Genome Compare View has a blue background and lets you compare the reference genome (rcrs) with the selected samples. You can view the following information in the view pane: } Reference genome } Selected samples for comparison } Call of a position for each sample } Variant indicator (blue line under the call) } Interpretation threshold indicator (purple line under the call) } User modified call indicator (asterisk sign next to the call) } Total number of samples Any changes you make are immediately updated to the following areas: } Reference Genome Compare View } mtdna Navigator } Coverage Plot When you select a sample (it is highlighted), the mtdna Navigator and Coverage Plot immediately update the position and coverage for that sample. Use these tools to refine your analysis. When you make changes to the Reference Genome Compare View, the changes are also reflected in the mtdna Navigator and Coverage Plot. mtdna Variant Analyzer v2.0 App Guide 7

Table 2 Reference Genome Compare View Tools Table Tools Description Sample Compare To make a selected sample a reference and compare it to the rest of the samples, highlight the sample by selecting it, and then drag the blue dot to the other side until the background is orange. Use this tool to find differences between samples or to find identical samples. Sample Selection To add more samples from the same project or a different project, use this tool to return to the BaseSpace projects page. Save When you modify a base call, use this tool to save changes to BaseSpace. The icon is activated when you make a change. Click Sample Selection to view samples that are modified. Filter Use this tool to filter samples for D-Loop, variants, interpretation threshold, and user modified. See Filter Options on page 8. Call for a Position Use this tool to view call details. See View Call Details on page 9. Generate Report Use this tool to export sample analysis data in Excel file format. Next Hotspot A hotspot is any variant, interpretation threshold indicator, or user modified position for the selected sample. Use the large arrow to get to the next hotspot. Next Page Use the small arrow to get to the next 15 positions. Filter Options You can select one or more filters per analysis. Table 3 Reference Genome Compare Filter Options Table Filter Description D-Loop This option constrains the view range positions from 16024 to 576. The constraint affects the Reference Genome Compare View, mtdna Navigator, and Coverage Plot. Variants This option filters the positions with variants for each sample. Interpretation Threshold This option filters the positions with interpretation threshold indicators for each sample. User Modified This option filters the positions that are modified. Sample Compare View The Sample Compare View has an orange background and lets you compare a specific sample with the selected samples. The sample located at the top of the list is the reference sample. You can view the following information in the view pane: } Reference sample } Selected samples for comparison } Call of a position for each sample } Differences indicator (orange line under the call) 8 Doc # 1000000007934 v00

} Interpretation threshold indicator (purple line under the call) } User modified call indicator (asterisk sign next to the call) } Total number of samples Any changes you make are immediately updated to the following areas: } Sample Compare View } mtdna Navigator } Coverage Plot When you select a sample (it is highlighted), the mtdna Navigator and Coverage Plot immediately update the position and coverage for that sample and the reference sample. The tools for tools for the Reference Genome Compare View and Sample Compare View are the same, with the exception of the following differences. See Reference Genome Compare View on page 7. Analysis Output Table 4 Sample Compare View Tools Table Tools Description Sample Compare To return to the Reference Genome Compare View, drag the orange dot to the other side until the background is blue. Filter Use this tool to filter samples for D-Loop, differences and zero differences, interpretation threshold, and user modified. See Filter Options on page 9. Sample Navigation Use this tool change the sample you want to compare. Click the arrow to move the selected sample to the top of the list. Filter Options You can select one or more filters per analysis. Table 5 Sample Compare Filter Options Table Filter Description D-Loop This option constrains the view range positions from 16024 to 576. The constraint affects the Sample Compare View, mtdna Navigator, and Coverage Plot. Differences This option filters the positions that are different from the reference sample. Interpretation Threshold This option filters the positions with interpretation threshold indicators for each sample. User Modified This option filters the positions that are modified. Zero Differences This option filters samples that are not different from the reference sample. View Call Details 1 Click a specific call position to view the Detailed Call View. 2 [Optional] From the Original Call field, expand the drop-down arrow to select a different call. mtdna Variant Analyzer v2.0 App Guide 9

Detailed Call View Table 6 Detailed Call View Table Call Detail Description Reference Sample Name Sample Name Call Paired-End Depth Score Percentages it at Original Call The reference sample name. The sample name for the result. The call for the position. The maximum depth of either the forward or reverse reads. Score for the call. The percentages are stacked and shown in relation to the thresholds. The location where the interpretation threshold resides for the sample. The location where the analytical threshold resides for the sample. The original call. To change the call, expand the drop-down arrow and select a call from the list. mtdna Navigator Coverage Plot The following are the mtdna Navigator features: } The pointer indicates the position in the Reference Genome Compare View or Sample Compare View. } To view genomic variants, interpretation threshold, D-Loop positions, and selected coverage, move the pointer around the circle plot. } The mtdna Navigator zooms in to show more details of the D-Loop area when you select the D-Loop filter option in the Reference Genome Compare View or Sample Compare View. } The mtdna Navigator shows coverage for the selected sample in relation to the visual representation of the genome. In Sample Compare View, the app shows the overlapped coverage of the reference sample and selected sample. Any changes you make are immediately updated in the following areas: } mtdna Navigator } Reference Genome Compare View or Sample Compare View } Coverage Plot The following are the Coverage Plot features: } The pointer indicates the position in the Reference Genome Compare View or Sample Compare View. } To zoom in and out, enter a value in the Coverage field. 10 Doc # 1000000007934 v00

} When you are in Reference Genome Compare View, the blue line in the coverage plot represents the coverage for the selected sample. } When you are in Sample Compare View, the gray line in the coverage plot represents the coverage for the reference sample and the orange line represents the coverage for the selected sample. Any changes you make are immediately updated in the following areas: } Coverage Plot } Reference Genome Compare View or Sample Compare View } mtdna Navigator Analysis Output Aggregate Analysis Report The mtdna Variant Analyzer App generates an aggregated summary of all the analyzed samples in an Excel file. Table 7 Summary Table Statistic Sample Single Nucleotide Variants (SNVs) Insertions Deletions Manually Changed Calls Variants Definition The sample name. The number of positions where the call for the sample differs from the reference genome (rcrs). The number of one or more nucleotides inserted in the sample genome. The number of one or more nucleotides deleted from the sample genome. The changed call when it is modified, which is presented as [position] [original call] -> [new call]. The position and call for calls that differ from the reference genome. Sample Analysis Reports In addition to the aggregated summary of all the analyzed samples, the mtdna Variant Analyzer App generates a summary of read count and variant statistics for each sample in the same Excel file. Table 8 Sample Analysis Table Statistic Definition Sample Single Nucleotide Variants Insertions Deletions The sample name. The number of positions where the call for the sample differs from the reference genome (rcrs). The number of one or more nucleotides inserted in the sample genome. The number of one or more nucleotides deleted from the sample genome. mtdna Variant Analyzer v2.0 App Guide 11

Statistic Manually Changed Calls Variant Reference Score Paired-End Depth Reads A, C, G, T Percent A, C, G, T Reads Del Percent Del Definition The changed call when it is modified, which is presented as [position] [original call] -> [new call]. The position and call for calls that differ from the reference genome. The base position in the reference genome (rcrs). When there is an insertion, the reference base reports a plus (+) sign. The score for the call. The maximum depth of either the forward or reverse reads. The number of forward and reverse reads for the A, C, G, or T bases at the call position. The percentage of forward and reverse reads out of the total reads for the A, C, G, or T bases at the call position. The number of forward and reverse reads for a deletion at the call position. The percentage of forward and reverse reads out of the total reads for a deletion at the call position. 12 Doc # 1000000007934 v00

Technical Assistance For technical assistance, contact Illumina Technical Support. Table 9 Illumina General Contact Information Website Email www.illumina.com techsupport@illumina.com Table 10 Illumina Customer Support Telephone Numbers Region Contact Number Region Contact Number North America 1.800.809.4566 Japan 0800.111.5011 Australia 1.800.775.688 Netherlands 0800.0223859 Austria 0800.296575 New Zealand 0800.451.650 Belgium 0800.81102 Norway 800.16836 China 400.635.9898 Singapore 1.800.579.2745 Denmark 80882346 Spain 900.812168 Finland 0800.918363 Sweden 020790181 France 0800.911850 Switzerland 0800.563118 Germany 0800.180.8994 Taiwan 00806651752 Hong Kong 800960230 United Kingdom 0800.917.0041 Ireland 1.800.812949 Other countries +44.1799.534000 Italy 800.874909 Technical Assistance Safety data sheets (SDSs) Available on the Illumina website at support.illumina.com/sds.html. Product documentation Available for download in PDF from the Illumina website. Go to support.illumina.com, select a product, then select Documentation & Literature. mtdna Variant Analyzer v2.0 App Guide

Illumina 5200 Illumina Way San Diego, California 92122 U.S.A. +1.800.809.ILMN (4566) +1.858.202.4566 (outside North America) techsupport@illumina.com www.illumina.com