Catalogue (1)Product Overview ()Product Dimensions (3)Product Specifications (4)Fittings and Wires for Installation ()Installation Diagram (6)Power/ Signal Connection for LED Screen (7)Connection Diagram of LED screen and Control System (SDV Controller,SDV Signal Divide,Control Computer) 1 Product Overview IDsn ODsn Series Indoor LED :deepest blackness levels and light absorbing techniques Super Visual Effect Carbon Fiber materials for super light, thin and stretch-proof structure 4 degree curved frame allows for 90 degree curved installation Easy&flexible installation allows for complex setups Grayscale processing&color calibration techniques ensues amazing graphic quality LCD Info Display: Indicating working hours,working temperature,power status Product Dimensions New carbon fiber composite materials. Vertical tensile resistance max 1.4 tons. Ultrathin design & lightweight.only 17.kg/ sqm. Modular design for convenient maintenance. 00mm 00mm 60mm LED Panel X Back Cover Power Supply SI/AC Panle Cable 3 Product Specifications Parameter Pixel Pitch (mm) Pixel Density (dots/m ) Pixel / Panel (W*H) Brightness Max (cd/m ) Grey Scale (bit) Refresh Rate (Hz) Frame Rate (Hz) Contrast Scan Mode Color Temperature (after calibration) (K) Horizontal / Vertical Viewing Angle ( ) Panel Size (W x H x D) (mm) Module Size (W x H ) (mm) Weight (kg/panel) Protection Power Supply Working Voltage(V) Max Power Consumption (w/pc) Avr Power Consumption (w/pc) Working Temperature Cabinet Material Panel weight bearing capacity Signal Cable Video Signal Input Interface Life Time (h) Type Glux LED Display IDsn series IDsn.6 IDsn3.9 IDsn. IDsn7.8.6 3.9. 7.8 746 636 36864 16384 19x19 18x18 96x96 64x64 600 / 1000 1000 1000 1000 000 100 / 1/16 1/16 1/6 1/4 H0/V0 H0/V0 H0/V0 H0/V0 00x00x3 00x00x3 00x00x3 00x00x3 Single power(dual power) Single power(dual power) Single power(dual power) Single power(dual power) AC100-40V/0/60Hz AC100-40V/0/60Hz AC100-40V/0/60Hz AC100-40V/0/60Hz (300) 7() 7 7 7 1
Parameter Pixel Pitch (mm) Pixel Density (dots/m ) Pixel / Panel (W*H) Brightness Max (cd/m ) Grey Scale (bit) Refresh Rate (Hz) Frame Rate (Hz) Contrast Scan Mode Color Temperature (after calibration) (K) Horizontal / Vertical Viewing Angle ( ) Panel Size (W x H x D) (mm) Module Size (W x H ) (mm) Weight (kg/panel) Protection Power Supply Working Voltage(V) Max Power Consumption (w/pc) Avr Power Consumption (w/pc) Working Temperature Cabinet Material Panel weight bearing capacity Signal Cable Video Signal Input Interface Life Time (h) Glux LED Display ODsn series Type ODsn3.9 ODsn. ODsn7.8 3.9 636 18x18 4000 / 6000 000:1 1/8 H0/V0 00x00x6 IP6(Front/Rear) Dual power supply AC100-40V/0/60Hz 300 The specifications and product images may change without prior notice.. 36864 96x96 4000 / 6000 000:1 1/6 H0/V0 00x00x6 IP6(Front/Rear) Dual power supply AC100-40V/0/60Hz 300 7.8 16384 64x64 6000 190 000:1 1/4 H0/V0 00x00x6 IP6(Front/Rear) Dual power supply AC100-40V/0/60Hz 300 4 Fittings and Wires for Installation FADock AMDock FALock AMLock FAPin Corner/Edge Connecting Sheet Signal Cable Neutrik-Neutrik(10m) Signal Cable Neutrik-Glux(10m) Signal Cable Neutrik-ODU(10m)
Power Cable Neutrik-Neutrik(6m) Power Cable Neutrik-Glux(6m) Power Cable Neutrik-ODU(6m) For actual accessories and cables,please select according to the product connector and installation way. Installation Diagram Hanging Installations Step1: Fasten installation clips (FADock/AMDock) to the truss or ceiling support Step: Lifting LED display modules Step3: Connect the panels together via installation blocks(falock/amlock) Step4: After installation finished, use FAPin/AMPin make the screen more flat Frame Installations OR Step1: Assemble and combine the frame and prepare the necessary accessories. Step: Assemble and fix LED display modules to the frame via FALock/AMLock Step3: Connect the panels together via installation blocks(falock/amlock) Step4: After installation finished, use FAPin/AMPin make the screen more flat 90 Degree Special Installations Step1: Connect the panels together via edge connecting sheets Step: Use FAPin/AMPin make the screen more flat Step3: Connect the three sides of the screen together via corner connecting sheets. Step4: Assemble a 90 degree screen via corner/edge connecting sheets 3
6 Power/Signal Connection for LED Screen Power/ Signal Connection Diagram Power/ Signal Connection Impression Drawing Power connecting way shown as the red line, signal connecting way shown as the blue line. Power Cable Signal Cable To ensure the safety use, for singlesupply panels connected not exceed 1 pieces, dual-power supply product not exceed 8 pieces During the installation and dismantlement, shall not be energized 7 Connection Diagram of LED screen and Control System! For details on the setting procedure, refer to the VSP controller manual. Ethernet Cable LED Screen Control Computer USD Cable or Ethernet Cable DVI or SDI input Mode1:Ethernet Cable Mode:Ethernet Cable Mode3:Optical Fiber Cable VSP-FL4 Main Controller SDV Signal Divider AC 0V AC 0V Video Source PDV Power Supply Divider 4
8 Safety Summary Read the following safety precautions carefully to avoid injury and prevent damage to this product or any products connected to this product. To avoid potential hazards, use this product in accordance with regulations. Only qualified personnel can perform service procedures. 1. avoid fire or personal injury. use the appropriate power line. Please only use the dedicated power cord for this product, which acquire the international / regional certification. Connect and Disconnect Properly. When add Connection and removal of all connection operation, make sure no contact with the voltage source.. Make the product grounded. The product is grounded through the grounding conductor of power line in order to avoid electric shock, the grounding conductor must be connected to the earth well. Before the power input or power output of this product, make sure it is correctly grounded. 3.comply with all terminal ratings. To avoid fire or electric shock, observe all ratings and markings on the product, before make connections to the product, read the manual for further ratings information. The voltage applied to any terminal and the power requirements do not exceed the maximum rating of the terminal. 4.Do not operate without covers. Do not open the housing or panel when using the product.
Glux Visual Effects Tech(Shenzhen)Co.,Ltd Nanshan OTC Eastern Industrial Park, Bldg.A4,Office 04, Shenzhen,Guangdong,China-Postal Code:18000 Tel:+86-7-88866999 Fax:+86-7-8641789 Glux Industrial Park.Donghuan nd Road,Longhua New District, Shenzhen,Guangdong 18109 P.R. China Tel: +86-7-9174931 Fax:+86-7-863733 Web Set:www.glux.com.cn www.glux.cc