Installation and handling of. elevator flat cable system and Compensation weight CW. Cabling Solutions

Similar documents
Termination Instructions. FO Patch panel OV-A / OV-AT 19 /1U. Cabling Solutions

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Caution. Hanging the Screen:

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Gel-sealed in-line fiber optic closure

Instructions. Cable with Armor F CAUTION. October Rev A

FOSC 450 C6 and D6 Closures

Cable installation guidelines

INSTALLATION INSTRUCTIONS

2178-L/S Series Fiber Optic Splice Case with Gasket

BML-M0 _-I -A _-... User's Guide

Installation Guide OvalSox TM Cable

3M Distribution Box (DDB)

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

SLiC Fiber Aerial Closure System

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Aerial Cable Installation Best Practices

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Installation instructions Roxtec RM ES systems

Installation instructions Roxtec RM BG systems

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Installation instructions Roxtec RM BG B systems

Comprehensive elevator cable systems Catalogue

INSTALLATION INSTRUCTIONS FOR

Cold Shrink Straight Joint

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

Support Frame STB Technical Instruction Manual

HCS - HES Cabling Systems

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

[ ] Concept. User manual. Made in Germany

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

J-Pro Cable Support System Let Panduit Support Your Cables

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Photovoltaic Module Installation Manual (IEC)

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Installation instructions Roxtec RM PE

VITALink Taped Splice Straight Through Crimp

3M Better Buried Compound Compression Closure System

Installation instructions Roxtec RM ES

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

HQ Electromagnetic Channel Locks

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

Round Traveling Cable Installation by Douglas Babcock and Dillard Green

Up to 85% higher Service Life due to efficient sealing method.

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

AS09..S 3-pole Contactors - Spring Terminals

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

Cable System Installation Guide

ENERGY /// TRICKS OF THE TRADE TRICKS OF THE TRADE

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

27mm ECAM Double Cable Entry Port

Installation instructions Roxtec RM PE B

OWNER'S MANUAL SIGNAL COMMANDER

1.8 METER SERIES 1183 Az/El MOUNT ANTENNA SYSTEM

Photovoltaic Module Installation Manual (IEC)

Setup Guide. Read me BefoRe unpacking!

Multi-Media Installation Guide

Installation instructions Cable transit device Roxtec RS ES Ex

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

Installation instructions Roxtec RM ES B

Satellite Dish Installation Manual (Ver. 2) 1

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

3M Better Buried Closures

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

TECHNICAL SPECIFICATION

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

SPECIFICATION. Spec No : VSS-1402-CS603B

FUNCTION IN FIRE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION FIRES-JR NURE

Incremental Hollow Shaft Encoder

READ ME FIRST. Touchstone TV Lift

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

INSTRUCTION MANUAL. Model V-4R Collinear Gain Vertical for MHz. General SPECIFICATIONS

RAIL D-SUB BACKSHELLS

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

M2 Antenna Systems, Inc. Model No: 23CM35

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

Installation Manual Wall Mounting

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS


Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

FOSC 400 A4 Fiber Optic Splice Closure

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

3M Fiber Optic Wall Mount Enclosure 8430 Series

Transcription:

Installation and handling of elevator flat cable system and Compensation weight CW Cabling Solutions

Installation and handling of Dynofil elevator suspension cables 1. Transport and storage 1.1 Transport of cable drums page 4 1.2 1.3 Moving cable drums page 4 5 1.4 Rewinding onto smaller coils page 6 1.5 Transport and storage of cable coils page 6 2. Installation instructions for all travelling heights 2.1 Installation positions on shaft wall and car floor page 7 2.2 Proper use of stripping knife page 8 2.3 Paying out of cables into the shaft page 9 3. Installation of Dynofil FL and FM 3.1 3.3 Suspension devices page 10 12 3.4 Maximum clamping thickness of suspension devices page 13 3.5 Cable combinations for Dynofil FL page 14 3.6 Cable combinations for Dynofil FM page 14 3.7 Securing the suspension devices to the shaft wall page 15 3.8 Fixing several adjacent suspension devices page 16 3.9 Fixing the suspension device on the elevator car page 16 3.10 Installation positions of suspension devices for Dynofil FL page 17 18 3.11 Installation positions of suspension devices for Dynofil FM page 19 20 3.12 Minimum loop spacing for cable combinations page 21 4. Installation of Dynofil FH and Compensation weight CW 4.1 Suspension device page 22 4.2 4.3 Securing the suspension device page 23 4.4 4.5 Preparations for cable installation page 24 27 4.6 Cable combinations with wire ropes page 28 4.7 Combinations with different cable widths page 29 4.8 Installation of multiple suspension devices side by side page 30 4.9 Installation positions of suspension devices for Dynofil FH page 31 32 4.10 Installation position of Compensation weight CW page 33 Accessories page 34 Warranty and Safety information: Failure to follow these procedures will not only invalidate product warranty, but could endanger public safety. Using other than strongly recommended Daetwyler suspension devices, Hilti fixation material or equivalent hardware could seriously jeopardize the safety of your installation and void any warranty. 3

1. Transport and storage Panel is nailed securely to drum flanges Drum flange Wooden panel 1.1 Transport of cable drums Whether on vehicles, railway wagons or in interim storage areas, cable drums must always be positioned on the two drum flanges. The cable on the drum must be protected with a foil covering. If cable drums are stacked on top of each other, stable wooden panels are to be placed between the individual layers. The wooden panels must always be nailed securely to the flanges of the cable drums underneath. 1.2 Moving cable drums If Dynofil cable drums are moved manually, they must only be moved in the direction of the arrow. The direction arrow is printed on both drum flanges. 4

1.3 Moving cable drums by fork-lift The cable drums must always be placed crossways on the forks of the truck. 5

1. Transport and storage Cable printing must be on the outside of the loop 1.4 Rewinding onto smaller coils Cable coils up to approx. 50 m(165 feet). For transporting small cable units (e. g. on building sites, in temporary storage areas, etc.) Dynofil cables must be rewound onto a cardboard core. Rewinding onto coils is always performed in the inherent loop direction of the cable Cardboard core: Ø=at least 28 cable thickness, minimum 200 mm Transport and storage of multiple cable coils (stacked) 1.5 Transport and storage of cable coils For transport and storage the cable coils should be tied with 4 fabric tapes. Tape width: 10 15 mm (0.4 0.6 inches) If cable coils are stacked for transport or storage, plywood boards should always be placed between the individual coils. Bind 4 with cotton tape Tape width: 10 15 mm (0.4 0.6 inches) 6

2. Installation instructions for all travelling heights 2.1 Installation positions on shaft wall and car floor The installation positions on the wall and car floor must be precisely aligned. 7

2. Installation instructions for all travelling heights 2.2 Proper use of stripping knife Stripping knife (Part No. 163358) for safe dismantling of the cable sheath. 8

2.3 Paying out of cables into the shaft All Dynofil elevator suspension cables (FL, FM, FH) can be paid out from the top or drawn up from the bottom. The Compensation weight CW has always to be paid out from the bottom! Cable must always be paid out in the direction parallel to the drum flanges. On no account should the drum be laid on its side and the cable be removed around the flanges. This introduces twisting of the cable. It is imperative to maintain the inherent loop direction of the cable, i. e. the printing on the cable sheath should always be on the outside of the loop. If guide pulleys are used for unreeling, the minimum pulley diameter is 28 cable thickness. 9

3. Installation of Dynofil FL and FM 3.1 Suspension device LZ 1006 Color: yellow (Part No. 178645) Color: grey (Part No. 179813) The cable width, number of cables (combinations) and travelling height determine the selection of cable suspension. Clamping wedge Dynofil elevator suspension cables with a width b 55 mm (2.17 inches) are normally installed with the nylon suspension device LZ 1006. This is easy to handle and ensures correct cable installation. C D B Maximum clamping thickness of suspension devices In addition to cable width and travelling height, the number of cables (cable combinations) to be mounted determine the selection of the correct suspension device(s). To this end, please note the maximum clamping thickness of the individual suspension parts. G A Clamping range for LZ 1006: Max.14 mm (0.55 inches) F E Bracket Dimensions A =100 mm (3.94 inches) B = 65 mm (2.56 inches) C = 47 mm (1.85 inches) D = 55 mm (2.17 inches) E = 13.5 mm (0.53 inches) F = 43 mm (1.69 inches) G = 73 mm (2.87 inches) Hilti HPS 6/5 Bolt M 6 20 10

3.2 Suspension device LZ 1009 Color: yellow (Part No. 175159) Color: grey (Part No. 179814) The cable width, number of cables (combinations) and travelling height determine the selection of cable suspension. Clamping wedge Dynofil elevator suspension cables with a width b 56 79 mm (2.2 3.11 inches) are normally installed with the nylon suspension device LZ 1009. This is easy to handle and ensures correct cable installation. C D G B Maximum clamping thickness of suspension devices In addition to cable width and travelling height, the number of cables (cable combinations) to be mounted determine the selection of the correct suspension device(s). To this end, please note the maximum clamping thickness of the individual suspension parts. Clamping range for LZ 1009: Max.15 mm (0.59 inches) Dimensions F A Bracket A =120 mm (4.72 inches) B = 92 mm (3.62 inches) C = 51.5 mm (2.03 inches) D = 79 mm (3.11 inches) E = 27 mm (1.06 inches) F = 73 mm (2.87 inches) G = 40 mm (1.57 inches) E Hilti HPS 6/5 Bolt M 6 20 11

3. Installation of Dynofil FL and FM 3.3 Suspension device LZ 1010 (Part No. 163354) The cable width, number of cables (combinations) and travelling height determine the selection of cable suspension. Dynofil elevator suspension cables with a width b = 80 100 mm (3.15 3.94 inches) are normally installed with the aluminium suspension device LZ 1010. C D G B Clamping wedge Maximum clamping thickness of suspension devices In addition to cable width and travelling height, the number of cables (cable combinations) to be mounted determine the selection of the correct suspension device(s). To this end, please note the maximum clamping thickness of the individual suspension parts. Clamping range for LZ 1010: Lower groove max. 14 mm (0.55 inches) Upper groove max. 22 mm (0.87 inches) Dimensions A F lower groove upper groove A = 140 mm (5.51 inches) B = 120 mm (4.72 inches) C = 50 mm (1.97 inches) D = 100 mm (3.94 inches) E = 22 mm (0.87 inches) F = 96 mm (3.78 inches) G = 60 mm (2.36 inches) Bracket E Hilti HPS 8/12 Bolt M 8 25 12

3.4 Maximum clamping thickness of suspension devices In addition to cable width and travelling height, the number of cables (cable combinations) to be mounted determine the selection of the correct suspension device(s). To this end, please note the maximum clamping thicknesses of the individual suspension parts. A Clamping range for LZ 1006: A=max. 12 mm (0.47 inches) Clamping range for LZ 1009: A=max. 15 mm (0.60 inches) B A Clamping range for LZ 1010: lower groove A=max. 14 mm (0.55 inches) upper groove B=14 22 mm (0.55 0.87 inches) 13

3. Installation of Dynofil FL and FM 3.5 Cable combinations for Dynofil FL A maximum of 2 3 cables of different widths can be installed with one suspension device. The narrowest width cable must be minimum 70 % of the widest cable. min. 70 % 100% 3.6 Cable combinations for Dynofil FM Only combinations of cables with the same width are permissible. 100% 100% 100% 14

3.7 Securing the suspension devices to the shaft wall The instructions apply to LZ 1006, LZ 1009 and LZ 1010: Fix bracket with Hilti HPS 6/5 or HPS 8/12 or equivalent. The dowel is tapped home with a hammer and then tightened with a screwdriver. Minimum concrete strength required: βw = 20 N/mm 2 Draw in cable. Insert wedge from above. Tap wedge home lightly with a hammer until the cable(s) is/are securely fixed. Tap home dowel and tighten Insert wedge and tap home lightly 15

3. Installation of Dynofil FL and FM 3.8 Fixing several adjacent suspension devices If a number of suspension devices (LZ 1006, LZ 1009 and LZ 1010) are mounted side by side, the minimum spacing between them is 50 mm (2 inches). A=min. 50 mm (2 inches) A A 3.9 Fixing the suspension device on the elevator car Fix bracket with screw M 6 or M 8 to the relevant installation device. Draw in cable. Insert wedge from above and tap home lightly with hammer. M 6 for LZ 1006 and LZ 1009, M 8 for LZ 1010 16

Suspension on shaft top 3.10 Installation positions of suspension devices for Dynofil FL 3.10.1 Dynofil FL Travelling height up to 40 m(130 feet) Free suspension length max. 45 m(150 feet) Permissible suspensions: LZ 1006, LZ 1009, LZ 1010 Suspension on elevator car According to data sheet (natural loop) Printing to shaft wall max. 45 m(150 feet) 17

3. Installation of Dynofil FL and FM Suspension on shaft top 3.10.2 Dynofil FL Travelling height up to 80 m(260 feet) Free suspension length max. 45 m (250 feet) Permissible suspensions: LZ 1006, LZ 1009, LZ 1010 Suspension on elevator car max. 45 m(150 feet) According to data sheet (natural loop) Printing to shaft wall max. 45 m(150 feet) Suspension at shaft midpoint 18

Suspension on shaft top 3.11 Installation positions of suspension devices for Dynofil FM 3.11.1 Dynofil FM Travelling height up to 75 m (245 feet) Free suspension length max. 80 m (260 feet) Permissible suspensions: LZ 1006, LZ 1009, LZ 1010 Suspension on elevator car According to data sheet (natural loop) Printing to shaft wall max. 80 m(260 feet) 19

3. Installation of Dynofil FL and FM Suspension on shaft top 3.11.2 Dynofil FM Travelling height up to 150 m (495 feet) Free suspension length max. 80 m (260 feet) Permissible suspensions: LZ 1006, LZ 1009, LZ 1010 Suspension on elevator car max. 80 m(260 feet) According to data sheet (natural loop) Printing to shaft wall max. 80 m(260 feet) Suspension at shaft midpoint 20

3.12 Minimum loop spacing for cable combinations Distance between loops 50 100 mm (2 4 inches) According to data sheet (natural loop) 50 100 mm (2 4 inches) 50 100 mm (2 4 inches) 21

4. Installation of Dynofil FH and Compensation weight CW E A D C 4.1 Suspension device LZ 4001 (Part No. 184606) The steel suspension device LZ 4001 is normally used for a maximum of 2 Dynofil elevator suspension cables or Compensation weight CW. F Dimensions A = 220 mm (8.66 inches) B = 170 mm (6.69 inches) C = 30 mm (1.18 inches) D = 160 mm (6.29 inches) E = 25 mm (0.98 inches) F = 13 mm (0.51 inches) B Bolt M12 40 Hilti HSL-TZ M 8/20 22

4.2 Securing the suspension device on the shaft wall The instructions apply to LZ 4001: Tighten safety anchor with wrench Fix LZ 4001 with safety anchor (Hilti HSL-TZ M 8/20 or equivalent). Minimum concrete strength required: βw =30N/mm 2 Tap home safety anchor fully with hammer. Tighten safety anchor with wrench. Torque = 25 Nm Expose supporting elements of cable and draw in cable (see 4.4 and 4.5). Hilti HSL-TZ M 8/20 safety anchor Tap home safety anchor fully and tighten 4.3 Securing the suspension device to the elevator car The instructions apply to LZ 4001: Fix LZ 4001 with screw M12 to corresponding installation device. Expose supporting elements of cable and draw in cable (see 4.4 and 4.5). Bolt M12 23

4. Installation of Dynofil FH and Compensation weight CW 4.4 Preparations for cable installation 4.4.1 Expose steel wire ropes to 700 mm A1/A2 A1 If the spacing of the steel wire ropes is 50 mm (2 inches), approx. 1000 mm (40 inches) of wire ropes must be exposed. A2 If the spacing of the steel wire ropes is 50 100 mm (2 4 inches), approx. 700 mm (28 inches) wire ropes must be exposed. 4.4.2 Fitting crimping sleeves Select the size of crimping sleeves according to table 4.4.3. Alternatively the free steel wire ropes can be clamped with Crosby clips G-450. Crimping sleeves according to table Alternatively the free steel wire ropes can be clamped with 3 Crosby clips G-450 24

4.4.3 Form first loop Draw one end of wire ropes through 1st sleeve. Compress sleeve according to table. Alternative to crimping sleeves: 3 Crosby clips G-450 each side 4.4.4 Form second loop Draw other end of steel wire ropes through 2nd sleeve. Use tape for parallel fixation. Compress sleeve according to table. Compress sleeve according to table 25

4. Installation of Dynofil FH and Compensation weight CW E 4.4.5 Steel Wire Connection CU Crimping Sleeve C D CU crimping sleeves Ø Steel Sleeve Type C D E Sleeves Crimps Section of wire Part No. (mm) (mm) (mm) per loop per crimping tool (mm) sleeve (inch) 2.5 166668 SL 2 3 5.7 9.4 11.4 1 + 1 2 3/32 3.0 166669 SL 2 4 8.2 12.5 14.6 1 + 1 2 1/8 3.2 166669 SL 2 4 8.2 12.5 14.6 1 + 1 2 1/8 4.0 182059 SL 2 5 9.3 15.0 16.1 2 + 2 3 5/32 5.0 182060 SL 2 6 11.4 17.0 25.7 2 + 2 3 3/16 6.0 182061 SL 2 7 11.7 18.1 22.2 2 + 2 3 3/16 Crimping tool Part No. 166667 with different crimps sections SL 2 3 2.5 mm SL 2 4 3.0/3.2 mm SL 2 5 4.0 mm SL 2 6/SL 2 7 5.0/6.0 mm Crimping tool has to be close to the end for a correct crimping process 26

4.5 Preparations for cable installation A1 If the spacing of the steel wire ropes is 50 mm (2 inches), the length of the loop (L) is at least 500 mm (20 inches). A2 If the spacing of the steel wire ropes is bigger than 50 mm (2 inches), the length of the loop (L) must be at least 300 mm (12 inches). L=loop length L A1/A2 27

4. Installation of Dynofil FH and Compensation weight CW 4.6 Cable combinations with wire ropes A maximum of 2 FH cables or Compensation weight CW can be installed on one suspension device LZ 4001. The adjacent illustration shows how the cables can be drawn in and suspended. 28

4.7 Combinations with different cable widths Two cables can be combined with different width of supporting member in one suspension device. The cables should be arranged with regard to their width so that the wire ropes do not affect or damage any of the cables. Care should be taken to ensure that supporting members in the narrower cable do not damage the surface of the wider cable. 29

4. Installation of Dynofil FH and Compensation weight CW 4.8 Installation of multiple suspension devices side by side If a number of suspension devices (LZ 4001) are installed side by side, the minimum spacing in case of concrete wall from anchor to anchor is 160 mm (6.29 inches). A=min.160 mm (6.29 inches) A 30

Suspension on shaft top 4.9 Installation positions of suspension devices for Dynofil FH 4.9.1 Dynofil FH Travelling height up to 200 m (656 feet) Free suspension length max. 220 m (722 feet) Permissible suspension devices: LZ 4001 Suspension on elevator car According to data sheet (natural loop) max. 220 m(722 feet) 31

4. Installation of Dynofil FH and Compensation weight CW 4.9.2 Dynofil FH Travelling height up to 400 m (1312 feet) Free suspension length max. 220 m (722 feet) Permissible suspension devices: LZ 4001 Dynofil travelling cables can be used to form a continuous connection between the elevator car and the top motor room. In this case an additional suspension device is necessary on the shaft top. Suspension on elevator car Or if preferred: The connection from shaft midpoint to shaft top is achieved with fixed wiring. In this case a junction box is required. According to data sheet (natural loop) Suspension at shaft midpoint max. 220 m(722 feet) A Minimum loop spacing: A=min.100 mm (4 inches) 32

4.10 Installation position of Compensation weight CW Free suspension length of maximum 220 mm. Permissible suspension devices: LZ 4001 Suspension on elevator car Suspension on counter weight According to data sheet (natural loop) 33

Accessories Wire rope cutter (Part No. 184575) Cuts steel wire ropes up to dia. 8 mm (0.32 inches) Stripping knife (Part No. 163358) Special knife to commence the removal of the cable jacket Crimping sleeves on demand Cutter (Part No. 179473) Tool-Box (Part No. 179278) Complete with all tools 2 Installation aid AV 400 (Part No. 176811) Universal shears (Part No. 179472) Steel wire ropes Crimping tool (Part No. 166667) Tool for splicing of steel wire ropes on Dynofil FH cables. 34

Switzerland Dätwyler Cabling Solutions AG Gotthardstrasse 31 6460 Altdorf, Switzerland T + 41 41 875-1268 F + 41 41 875-1986 info.cabling.ch@datwyler.com www.cabling.datwyler.com Germany Dätwyler Cables GmbH Auf der Roos 4-12 65795 Hattersheim, Germany T + 49 6190 8880-0 F + 49 6190 8880-80 info.cabling.de@datwyler.com www.cabling.datwyler.com Dätwyler Cables GmbH Lilienthalstraße 17 85399 Hallbergmoos, Germany T + 49 811 998633-0 F + 49 811 998633-30 info.cabling.de@datwyler.com www.cabling.datwyler.com Austria Dätwyler Cables GmbH Office Austria Tenschertstraße 8 1230 Wien, Austria T + 43 1 8101641-0 F + 43 1 8101641-35 info.cabling.at@datwyler.com www.cabling.datwyler.com United Arab Emirates Daetwyler Middle East FZE Suite 1004, 10th Floor, IB Tower Business Bay P. O. Box 263480 Dubai, UAE T +971 4 4228129 F +971 4 4228096 info.cabling.ae@datwyler.com www.cabling.datwyler.com Saudi Arabia Daetwyler Middle East FZE Office KSA Office #101, Alhumaid Center King Abdul Aziz Street Riyadh, KSA T +966 1 2630466 F +966 1 2630466 info.cabling.ae@datwyler.com www.cabling.datwyler.com China Datwyler Cables+Systems (Shanghai) Co. Ltd Building 16, No. 111, Kang Qiao Dong Road Kang Qiao Industrial Zone, Pudong Shanghai 201319, P. R. China T + 86 21 6813-0066 F + 86 21 6813-0298 info.cabling.cn@datwyler.com www.cabling.datwyler.com Datwyler (Suzhou) Cabling Systems Co. Ltd Block 31, 15# Dong Fu Road Suzhou Singapore Industrial Park Suzhou 215123, P. R. China T + 86 512 6265-3600 F + 86 512 6265-3650 harnessing.cabling.cn@datwyler.com www.cabling.datwyler.com Singapore Datwyler (Thelma) Cables+Systems Pte Ltd 29 Tech Park Crescent 638103 Singapore T + 65 68631166 F + 65 68978885 info.cabling.sg@datwyler.com www.cabling.datwyler.com Great Britain Datwyler (UK) Ltd Unit B, Omega Enterprise Park Electron Way Chandlers Ford Hampshire SO53 4SE, Great Britain T + 44 2380 279-999 F + 44 2380 279-998 info.cabling.uk@datwyler.com www.cabling.datwyler.com 2013 Datwyler - installation manual elevator cables - e - 07/2013