2X2 Panel 1X2 Panel
PRO-PANEL LED SOFTLIGHT Features: 2700K Tungsten - 6500K Daylight Controllable Range Continuous DMX 512 Dimming Control: 100%-0% Connect Multiple Fixtures for Uniform Dimming and Color Temperature Control Flicker Free DC Driving System CRI > 90 Heavy Duty Adjustable Yoke: Capable of Hanging in Studio or Portable Stand Mounting 3 Year Warranty Certifications: UL, FCC, and CE Max. Power Consumption: 115W, < 1A 90-240V AC Input Range Applications: Professional Cinematography Video Broadcasting Film Lighting Studio Lighting Photo Lighting Technical Specifications Watt USHIO USHIO Luminous Maximum Illumination Color (W) Ordering Lamp Weight Flux (lm) lux @ (lm) fc @ (lm) CRI Temp Code Description 2700K 6500K 2700K 6500K 2700K 6500K (K) 115 1003838 PRO-Panel 2X2 25 lbs. 5046 5566 1817 1997 169 186 >90 2700K-6500K 115 1003837 PRO-Panel 1X2 21 lbs. 4351 4980 1566 1781 145 165 >90 2700K-6500K Scan with a smartphone to view this product online. 2 Pro-Panel LED Guide
TABLE OF CONTENTS ProPanel LED Softlight Kit Includes... 4 Adjusting Yoke Handle... 5 Cable Connection Between Panels in DMX Control... 6 Remote DMX Dimming & Color Temperature Controller... 7 How to Set the Address Switch... 7! CAUTIONS AND WARNINGS Cautions and Warnings WARNING RISK OF ELECTRIC SHOCK! Turn off all power switches on the Pro-Panel fixture before connecting or disconnecting any AC power or control cables (main or jumpers). WARNING RISK OF ELECTRIC SHOCK! - Do not use in wet or damp operating locations (condensing humidity hazard). WARNING RISK OF ELECTRIC SHOCK! - Do not insert any tools or metallic objects into any gap in the fixture. WARNING RISK OF ELECTRIC SHOCK! Do not open the case, modify, or change any component of the product. Over Heating! - Do not cover or wrap the fixture with any cloth, textile, tape, or plastic during operation. Failure to abide by any of the above warnings will void the product warranty. WARNING! Securely tighten the yoke and any light stand connections before operation. Only use mounting hardware rated for the weight of the fixture. WARNING! When hanging the fixture from a truss the use of a safety cable is mandatory. Only hang in accordance to local safety laws and regulations. Operation / Storage / Handling Use and install this product only according to this operation manual and or local safety laws and regulations. CAUTION! Do not connect a DMX Control Console and the Pro-Panel Remote Controller at the same time. This will cause the interruption and improper operation of the light. CAUTION! Keep the panel upright during storage and transportation to prevent pressure and damage to the diffuser and LED board inside. CAUTION! Do not apply any pressure to the diffuser panel. This may crack the diffuser and or damage the LED board. Turn off all power and disconnect power cables prior to cleaning. Use only a clean dry cloth to clean the fixture. Do not spray any liquids onto or into the fixture. Pro-Panel LED Guide 3
PRO-PANEL 2X2 or 1X2 2 Standard Package Includes: 1 2 3 4 5 6 Light Panel and Yoke Assembled Remote DMX Dimming and Color Temperature Controller AC Powercon Cable AC Powercon Jump Cable (for Connecting Multiple Fixtures) 4-Pin DMX Cable (for Controller Extension) 5-Pin DMX Cable (for Connecting Multiple Fixtures) AC On/Off Switch 7 90º Honey Comb Louver 1 7 *CAUTION - Power must be in OFF position before installing or removing any power cable or DMX cables. 3 4 5 6 4 Pro-Panel LED Guide
Adjusting the Yoke Handle 1. Loosen 1. To position the Pro-Panel angle, loosen the clamp handle counter-clockwise. Adjust the panel to its desired angle, then rotate the clamp handle clockwise to tighten. Tighten 2. 2. To position the clamp handle to a desired location, pull outward on the clamp handle, then turn the clamp handle to its desired location and release. 3. 3. To adjust the resistance of the panel, loosen the hexagon wrench bolt (on the opposite end of the yoke) clockwise to tighten and counter-clockwise to loosen. Pro-Panel LED Guide 5
LINKING AC POWER CABLE CONNECTIONS Power Connection + + + Additional Panels LINKING DMX CABLE CONNECTIONS + + + Additional Panels Network Connection *Remote controller MAY NOT be used in tandem with a DMX control console. Power Connection Network Connection AC IN AC OUT Remote Controller Connection (4 Pole) Data IN Connection (5 Pole) Data OUT Connection (5 Pole) ON/OFF Switch 6 Pro-Panel LED Guide
DIP SWITCH SETTING FOR DMX CONSOLE How to set the channel switch (For Use With DMX Lighting Control Console) There are two DIP switches covered with rubber caps and are located at opposite corners of each other. Each set of DIP switches contains 10 switches that may be turned on or off. Each combination (on or off) represents a number called a Channel. Refer to the table on the right to assign the proper channel for your Pro-Panel. OFF position is represented as 0 and ON position is represented as 1. Make sure both sets of DIP switches are identical. Pro-Panel automatically occupies two consecutive channels to control both color temperature and intensity. For example, if the Pro-Panel is set to channel 6, the DMX channel 6 will control color temperature and channel 7 will control intensity. ID Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Dip Switch Number 1 2 3 4 5 6 7 8 9 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 0 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 1 1 0 1 0 0 0 0 0 0 0 1 1 0 0 0 0 0 1 0 1 1 0 0 0 0 0 0 1 1 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 Dipswitch values 1 2 4 8 16 32 64 128 256 Notes: 1. Default setting is 0.0.0.0.0.0.0.0.0.0, which is channel 1. 2. DIP switch slider #10 is not being used. 3. Note that the orientation of two DIP switches is opposite. 4. 2 or more Pro-Panels may be assigned in the same channel to simultaneously control color and intensity. REMOTE DMX DIMMING & COLOR TEMPERATURE CONTROLLER Remote Dimmer (For Standalone Application) Knobs: Knob marked Kelvin Control changes color temperature (2700K to 6500K) and knob marked Dimming Control changes intensity (0.0 to 100.0, increments of 0.4). Preset Buttons: Preset button Tungsten instantly changes the color temperature to 3200K. Preset button Daylight instantly changes the color temperature to 5600K. These buttons may be custom programmed to any color temperature. Customizing Preset Button: Adjust the Pro-Panel to desired color temperature setting using Kelvin Control then press either Tungsten or Daylight preset button for 3 seconds. Follow the same steps for each preset button. To restore to factory default, press both buttons for 3 seconds. LED Display: Displays the color temperature and intensity setting of the Pro-Panel. Customizable Daylight Preset Button Notes: 1. Remote controller may not be used in tandem with a DMX control console. 2. Remote controller connects to Pro-Panel using 4 pole XLR connector. 3. A remote controller may control multiple Pro-Panels at the same time (the channel must be set to 1 or DIP switches to 0.0.0.0.0.0.0.0.0). *To verify accurate color temperature the use of a light meter is recommended. Status Light: Red indicates power is on Customizable Tungsten Preset Button Kelvin Control Dimming Control Pro-Panel LED Guide 7
WWW.USHIO.COM USHIO AMERICA, INC 5440 CERRITOS AVENUE CYPRESS, CA 90630 T. 714.236.8600 F. 714.229.3180 TOLL FREE: 800.326.1960 USHIO CANADA, INC 2730 BRIGHTON ROAD, UNIT D OAKVILLE, ONTARIO CANADA L6H 5T4 T. 905.829.3338 F. 905.829.5343 TOLL FREE: 877.902.0722 Scan with a smartphone to view this product online. visit www.ushio.com M-PPLED/0113