Understanding Fidelity

Similar documents
LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LED Light Achieves The Colour Rendering Of Sunlight. Hubert Ott Technical Marketing Director Lighting Avnet Silica

An Introduction to TrueSource

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

PRESS INFORMATION February 2010

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

TOWARDS A USER ORIENTED DESCRIPTION OF COLOUR RENDITION OF LIGHT SOURCES 2.METHODS

XTM LED Module with Corrected Cold Phosphor Technology

OPTIMIZED LIGHT-EMITTING DIODE (LED) DEVICES THAT HAVE A HIGH COLOR RENDERING INDEX (CRI) FOR LIGHTING APPLICATIONS

Investigation of Color Rendering Performance Indicators for Lighting Systems

XTM LED Module with Corrected Cold Phosphor Technology

Upgrading to LEDs?: Things to Think About So it Doesn t Go Horribly, Horribly Wrong

Guidelines for Specification of LED Lighting Products 2010

XTM LED Module with Corrected Cold Phosphor Technology

LED Lighting 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design Lab

Calibration of Colour Analysers

XTM LED Module with Corrected Cold Phosphor Technology

LED Lighting for Critical Color Judgement Lessons from 8 Years in the Field

LED. no compromise. cold phosphor collection 2011

XCA LED Core Array with Corrected Cold Phosphor Technology

The Basics of LED Lighting

Analog Technologies. LED Bulb ATLB3W20

WEATHERPROOF LUMINAIRE

About LED Lighting. White Paper: Operating Characteristics. Low Power LEDs

Power saving in LCD panels

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison

CIE CIE

Q1. Do LED lights burn out?

PHONE: (303) FAX: (970) WEBSITE:

Evaluation Monitors and Projectors

Look on the Bright Side. LED Retrofits by Hillphoenix.

NVLAP LAB CODE:

NVLAP LAB CODE:

Light emitting diode standards where are we?

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

Press Release May 17, SMM Develops New Oxide-based Red Phosphor In Collaboration with Tohoku University Research Team

Unilume LED Undercabinet System

Considerations for Blending LED Phosphors

Color measurement and calibration of professional display devices

Light Emitting Diodes

PHILIPS IS MORE THAN JUST A LIGHTING EXPERT, WE RE YOUR PARTNER IN THE FASHION BUSINESS.

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Photometric Test Report

Report of Test LLIA

DATASHEET. Intematix ChromaLit Contour. Remote Phosphor Light Source. Features & Benefits. ChromaLit Contour. Application & Uses. A19 Reference Design

[source unknown] Cornell CS465 Fall 2004 Lecture Steve Marschner 1

Decorative lighting. Decorative Light

Guidelines for Specification of LED Lighting Products 2011

LightLab I N T E R N A T I O N A L

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

Cie L*55 a* b* Keeping Color in Fashion. Solutions for textile color consistency

LightLab I N T E R N A T I O N A L

Cie L*48.57 a* b* Covering the World. Solutions for paint and coatings color management

YJ-BC-3030-G01 High CRI LED

Color Maintenance of LEDs in Laboratory and Field Applications

Delivery test of the ALFOSC camera with E2V CCD Ser. no

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

NEXT GENERATION REMOTE PHOSPHOR LED LIGHTING SOLUTIONS

Development of OLED Lighting Panel with World-class Practical Performance

YJ-VTC-5730-G02 High CRI LED

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

architecture mounting Features Product lighting

AR-111 LED LED. LED Lamp for Arte-AR-111 Trac Fixture

Patterns Manual September 16, Main Menu Basic Settings Misc. Patterns Definitions

EdiPower III SL09 Series

TECHNICAL FOCUS: PRODUCT IN DEPTH

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Practical Lighting Design With LEDs

Application Note [AN-007] LCD Backlighting Technologies and Configurations

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

technical note flicker measurement display & lighting measurement

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED

In the center we ve got 2 views of a typical 2 foot by 4 foot fluorescent light fixture, or ceiling troffer. The upper photo shows it in the ceiling,

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

HALOLUX CERAM. Product family datasheet. Compact halogen lamps for use in narrow luminaires

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

ETC D40XT. Selador Desire Series GENERAL INFORMATION ORDERING INFORMATION. Desire D40XT

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

Transcription:

Understanding Fidelity What is Color Fidelity? How do we understand CRI and the new TM30 fidelity metrics and graphics? Fidelity Myths Many lighting people harbor misconceptions about the meaning of fidelity metrics such as CIE CRI Ra and TM30 Rf. For example: MYTH #1: two light sources of the same CRI will look pretty much the same MYTH #2: a light source with a higher CRI number will always look better than one with a lower CRI number In other words, they believe they can directly compare two light sources by looking only at a single CRI score. This is not at all true. fire. In fact, sunlight replaces the BBR as the reference for higher CCT sources, which creates an awkward discontinuity in the standard CRI test. Furthermore, there are situations when you may not want a perfect BBR. For example, the Xicato Beauty Series was developed for a major cosmetics retailer who wanted very high color rendering fidelity for skin tone comparisons, but has a side effect of making people look and feel better. Another goal may be to facilitate the observation of skin for medical diagnosis, as measured by the Cyanosis Observation Index (COI). Fortunately, you do not need to compromise traditional fidelity metrics to achieve an excellent COI score. For example, the Xicato Artist 3500K and 4000K, with CRI of 98, perform extremely well on this metric. Fidelity actually means Same-ness There are two widely used standards for measuring color rendering fidelity: CIE Color Rendering Index (CRI), the older standard for which Ra is the fidelity index IES TM-30-2015, a new standard for which Rf is the fidelity index Both tests use the same spectral power distribution (SPD) data to calculate how a tested light source would compare to a reference light source in rendering the colors of test samples. The maximum possible score in both tests is 100, which would mean that the tested source renders the colors of the test samples in exactly the same degree and proportion as the reference light source. There are two important things to understand about this: (1) it only compares the rendering of the test color evaluation samples (CES), and (2) it contains the implicit assumption that the reference light source is an ideal source. The same as What? The reference source for a CRI test at least for color temperatures up to 5000K is a theoretical black body radiator (BBR) of the same correlated color temperature (CCT) as the test source. In the real world, the closest thing to a theoretical BBR is a tungsten incandescent or halogen lamp, but even they are not quite perfect BBRs, due to the chemical elements that are being heated. A BBR is not necessarily ideal, or even natural. For example, the Sun is not a perfect BBR. Nor is a wood Black Body Radiator reference curves for CIE CRI and IES TM-30-2015. CRI has an abrupt discontinuity at 5000K. TM30 smooths the reference curve between 4500K and 5500K to mitigate problems with color match at points just above and below 5000K. The Problem with Swatches A bigger problem is with the test itself. Traditional CRI as defined by CIE only tests 8 color samples (see below), none of which test highly saturated colors, and which collectively fall far short of testing the entire gamut of visual light. In other words, even a CRI score of 100 only means that a light source is exactly like the BBR on eight muted colors! The list of swatches (R1 through R8) was extended to 14 or 15 by some, but these are rarely incorporated into the CRI number. More commonly, R9 has emerged as an important swatch that begins to fill the gap by providing a metric for red color rendering. CIE CRI color swatches CRI was okay for incandescent and to a lesser extent

HID and fluorescent sources, but it failed badly when comparing LEDs. After literally decades of debate, the IES finally took the bull by the horns and created TM-30-2015, which uses 99 Color Evaluation Samples (CES) (below) specifically chosen from real objects and dyes to represent a full, balanced gamut of colors, and which made every LED manufacturer s phosphor and die bin choice relevant to the score. (Note: The CIE has adopted the TM-30 fidelity metric with minor revisions, and also calls it Rf, but they have not yet retired the old Ra metric, so the potential for confusion remains.) Decreased Saturation Positive Hue Shift Reference Point Iso-Fidelity line Increased Saturation IES TM-30-15 Color Evaluation Samples (CES) CES 1 CES 2 CES 3 CES 4 CES 5 CES 6 CES 7 CES 8 CES 9 Negative Hue Shift CES 10 CES 19 CES 11 CES 20 CES 12 CES 21 CES 13 CES 22 CES 14 CES 23 CES 15 Type B CES 24 CES 16 CES 25 CES 17 CES 26 CES 18 Type B CES 27 This graphic shows that the same Fidelity number can be acquired by any type of deviation from the reference color rendering point. All points on the dotted line have the same fidelity score. CES 28 CES 37 CES 46 CES 55 CES 64 CES 29 CES 38 CES 47 CES 56 CES 65 CES 30 CES 39 CES 48 CES 57 CES 66 CES 31 CES 40 CES 49 CES 58 CES 67 CES 32 CES 41 CES 50 CES 59 CES 68 CES 33 CES 42 CES 51 CES 60 CES 69 CES 34 CES 43 CES 52 CES 61 CES 70 CES 35 CES 44 CES 53 CES 62 CES 71 CES 36 CES 45 CES 54 CES 63 CES 72 For example, the images below are of the same scene illuminated by two light sources with the same CRI Ra (80) and TM30 Rf (78). Yet one looks entirely different than the other, and both are very different from their appearance under a reference light source. The source on the top is highly red saturated, while the one on the bottom is obviously undersaturated. And both exhibit color shift. CES 73 CES 74 CES 75 CES 76 CES 77 CES 78 CES 79 CES 80 CES 81 CES 82 CES 83 CES 84 CES 85 CES 86 CES 87 CES 88 CES 89 CES 90 CES 91 CES 92 CES 93 CES 94 CES 95 CES 96 CES 97 CES 98 CES 99 A = Nature B = Skin C = Textiles D = Paints E = Plastic F = Printed G = Color System Less than 100 Loses Meaning What do we know about two sources that have a fidelity score below 100? Unfortunately, the further from 100 we get, the less we know. That is because the metric only tells us the average differences of the various CES from the reference, without telling us specifically how each color differs. For example, a score of 85 means that, on average, the samples are 15 units different from the reference. All of the colors may be 15 units more saturated, or less saturated, or color shifted to one side or the other. More likely, a few of the colors may be very accurate, and a few others very inaccurate; some saturated, others unsaturated, others shifted. But we don t know which color is which! One 85 CRI light source may show highly saturated colors, while another shows drab, gray colors. And a source with a CRI of 70 might provide a much more pleasing effect than one with a score of 85! Images courtesy of Randy Burkett Lighting Design

Providing Meaning Xicato Standard Series 3000K TM30 fidelity on all 99 color evaluation samples To help lighting designers choose, TM30 provides several informative graphics that present Fidelity in different ways. For example, the graphic above shows the fidelity of the Xicato Standard Series (83 CRI) in 3000K CCT. A taller column represents higher color fidelity in that particular color, with a maximum of 100. The average of all of these values yields the TM30 fidelity metric, Rf, of 78. Left: Hue angle graph for Xicato Standard Series 3000K, showing color groups that are over- and under-saturated. A casual observer might assume that the relatively short columns in yellow mean that there is less yellow in the light source. But the reality is the opposite! To simplify presentation of color information, TM30 averages colors into 16 related groups, called hue angles. On the left, we see a graph that shows the relative saturation of the different hue angles for Standard 3000K. Notice that the yellow in Xicato Standard Series is lower in fidelity because yellow is OVER saturated. You can also see that greens and purples are slightly over-saturated, while reds and cyans are relatively under-saturated. Now, let s look at a very high fidelity light source; the Xicato Artist Series in 3000K CCT, which has a CRI of 98 and a TM30 Rf of 96 (note that TM30 is a tougher fidelity metric!). Artist Series is specifically engineered to replace halogen and incandescent lighting in color critical applications: Notice that all of the columns are very tall, with no significant gaps.

In fact, many colors are spot on, and no color group deviates more than 3% in saturation from the reference, as shown by the graph below. superimposed on it. The gray circle represents the ideal color rendition of the 3000K reference source, and the red line represents the relative color rendition in each of the 16 hue angle bins of the tested source. A perfect tested source would of course be superimposed directly on top of the gray circle. Like the hue angle graph above, this graphic shows you again that yellow-greens and purples are slightly oversaturated in the Standard Series product, and that blues and reds are slightly under-saturated. But it tells you even more... Left: Hue angle graph for Xicato Standard Series 3000K, showing color groups that are over- and under-saturated. Color Vector Graph So far, we have talked about how the fidelity score indicates the average deviation of a test source from the reference on a selection of CES. We have shown graphs that illustrate variation in saturation, but what about color shift, which is typically a much more objectionable variation? Notice the tiny arrows that point in or out from the gray circle toward the red figure. The length of these arrows tells you the degree of variation from the reference, and the direction tells you in what way the hue bin differs. Oversaturated = radially outward Undersaturad = radially inward Hue shifted = tangential So as is typical for most light sources, Standard is slightly hue-shifted in areas near the intersection of the two lines. Now let s look again at Xicato Artist Series... TM30 has a graphic for that, too... in many ways, the best single graphic for understanding a light source lit effect. Below is the TM30 color vector graph for the Xicato Standard Series 3000K LED light source... the same as shown above. Observe that there is a color space with a gray circle and a red, roughly elliptical shape!"#"$%&'!("$%)$*+,-!% Reference Illuminant Xicato 9530 Reference Illuminant Xicato 8030 Notice that it is very difficult to see the tiny arrows. This is a good thing! What you see is that the red Artist line almost perfectly overlays the reference line, that the arrows are very short, and that they are all radial. In fact, Artist is ever so slightly oversaturated where it deviates, which is generally preferred, resulting in a slightly larger color gamut than the reference source.

The vector graphic for Artist 2700K, shown below, is similarly precise. This is why Xicato Artist Series is an ideal replacement for halogen lighting. The high fidelity, balanced color rendering of Artist Series has made it the preferred light source for art museums worldwide. It is used by high quality retailers and even grocers for its ability to reveal product, bringing out the rich colors of wood, ceramics, fabrics and leather, as well as the true colors of produce and packaging. Conclusion You can see that simplistic fidelity metrics that present a single number especially as the number drops further below 100 do not provide complete information about the lit effect of a light source. Of course, the best meter is your eyes, and the best test is to compare actual sources by shining them on the objects that will actually be in your space. Absent that, TM30 is a much better tool than CIE CRI, providing much more information that enables lighting designers to make better choices for their clients. Xicato was the first to publish full TM30 data on all of its color series, and we continue to be available to lighting designers, manufacturers and end users who want to learn more about color fidelity, gamut, quality, and metrics. Contact your Xicato representative or write to marketing@xicato.com for more information. xicato.com @XicatoInc Reference Illuminant Xicato 9527