C E R T I F I C A T E O F C O M P L I A N C E

Similar documents
Circuit-Breakers for Motor Protection Series 8523/8

High performance circuit breakers

Power Circuit of a UL508A Panel. Typical UL489 Application

Type MG-6 Auxiliary Relay Class 1E

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

AUTOMATIC TRANSFER SWITCHES. Product Guide

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Digital output modules

Bulletin 190 IEC Modular Starter System

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Magnetic and Hydraulic-Magnetic Circuit Breaker

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Type: DILM12 10(24VDC) Article No.:

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

llen-bradley 194R-HM4-NFPA3

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2P05. Main. Device short name. Device application

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

GP-500 SERIES - Low Voltage

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

XT IEC Power Control Combination Motor Controllers

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

PRINCIPLES AND APPLICATIONS

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Type: DILM25 10(24V50HZ) Article No.:

GV2ME. Main. Device short name. Device application

Kinetix Application Note

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Series CT7N Bimetallic Overload Relays

TeSys circuit-breakers

Magnum Panel Systems. UL1741 Interconnection System Equipment. The Powerful Difference

A V 50Hz / V 60Hz

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

GR circuit breaker - hydraulic magnetic, Datasheet

Active UTP Transceiver Hub Installation Guide

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Magnecraft Power Relays

3AH3 Vacuum Circuit-Breakers

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Pendant Light Fitting IEC Series 6470/2

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

CAMTO LTD. Arc detecting system DC/AC

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Switching Power Module

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

COHERENCE ONE PREAMPLIFIER

Series CDP2 Definite Purpose Contactors

GR circuit breaker - hydraulic magnetic, Datasheet

Intertie Protection M 3520

EMC Solutions Noise filtering

AS09..S 3-pole Contactors - Spring Terminals

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

PRELIMINARY Sunny Boy 240-US

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Product Discontinuation Notices. Discontinuation Notice of built-in Power Supply Photoelectric sensors E3B2 series

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

KRF EMC Filters Installation, Operation and Maintenance Manual

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

STEVAL-ISA001V1. 6W Dual Output Supply using VIPer12A. Features. Blue angel. Applications

Minicontactorrelay,2NO/2NC,DCoperated

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Hypnotica is Color Changing Series

Split System Air Conditioner

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Medium and High Voltage Circuit Breakers Characteristic Time Quantities of the Circuit Breaker with Applications

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

SURGE PROTECTIVE DEVICES

SPECIFIC TECHNICAL CRITERIA

Data Sheet Definite Purpose Contactors Ex9CK Series

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Datasheet - SRB-E-201ST

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Toronto Hydro - Electric System

BE3-GPR GENERATOR PROTECTIVE RELAY

DSP 18 Sub active subwoofer. user manual

Series CDP2 Definite Purpose Contactors

Ordering details. Approval. Classification

Type Contact form Model

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Certificate of Compliance

02/11/2015

EA350. Generator Automatic Voltage Regulator Operation Manual

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Transcription:

JG Frame, Types NJGA, HJGA and LJGA. These are two and three pole circuit breakers with interchangeable thermal magnetic and electronic trip units. They are uncompensated 40 o C construction rated 250-400 A, 600 V ac, 250 V dc (two pole) and 500 V dc (three pole for ungrounded UPS systems). Circuit breakers with electronic trip units are not marked with dc ratings. These circuit breakers may be marked for 100% continuous current, and HACR Type.. Current interrupting ratings are as follows: Voltage Poles Ratings Type NJGA Type HJGA Type LJGA 240 ac, 50/60 Hz 2,3 65 ka 100 ka 200 ka 480 ac, 50/60 Hz 2,3 35 ka 65 ka 100 ka 600 ac. 50/60 Hz 2,3 25 ka 25 ka 25 ka 250 dc 2 30 ka 30 ka 30 ka 500 dc 3 25 ka 35 ka 35 ka

Report Reference E10848, 2006 January 19 JG Frame, Type HJMA. Three pole, rated 400A, 600 V ac, 250 V dc.

Certificate Number 20130813 E68312 Report Reference E68312, 2006 January 20 Molded Case Switch JG Frame, Type HJGA and LJGA. Two and three pole, rated 400A, 600V ac, 250 V dc. Does not provide overcurrent protection. This switch is suitable for use on a circuit capable of delivering not more than: Voltage Max RMS Symm. Amp Type HJGA Type LJGA 240 ac, 50/60 Hz 100 ka 200 ka 480 ac, 50/60 Hz 65 ka 100 ka 600 ac. 50/60 Hz 25 ka 25 ka 250 dc 30 ka 30 ka When protected by a fuse or circuit breaker, rated 400A maximum. May open circuit above 5500 A., CAN/CSA-C22.2 No. 5 (2002), Molded-Case Circuit Breakers, Molded-Case Switches and. Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with C and US identifiers: the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category

JG Frame, Types NJGA4, HJGA4 and LJGA4 These are four pole circuit breakers with interchangeable thermal magnetic trip units. They are uncompensated 40 o C construction rated 250-400 A, 600 V ac. The neutral pole does not have overcurrent protection. Current interrupting ratings are as follows: Voltage Poles Ratings Type NJGA4 Type HJGA4 Type LJGA4 240 ac, 50/60 Hz 2,3 65 ka 100 ka 200 ka 480 ac, 50/60 Hz 2,3 35 ka 65 ka 100 ka 600 ac. 50/60 Hz 2,3 25 ka 25 ka 25 ka

JG Frame, Type NJJA. These are two and three pole circuit breakers with non-interchangeable thermal magnetic trip units. They are uncompensated 40 o C construction rated 250-400 A, 240 V ac, 250 V dc (two pole). These circuit breakers may be marked HACR Type Current interrupting ratings are as follows: Voltage Poles Ratings Type NJJA 240 ac, 50/60 Hz 2,3 65 ka 250 dc 2 30 ka

JG Frame, Type HJGD. These are complete three pole circuit breakers with thermal magnetic trip units. They are uncompensated 40 o C construction rated 250-400 A, 600 V dc. These circuit breakers may be marked HACR Type. Current interrupting ratings are as follows 65 ka, 600 Vdc and CAN/CSA-C22.2 No. 5, Molded-Case Circuit Breakers, Molded-Case Switches and Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with C and US identifiers: the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category