Downtown Arts Center Tech Packet. General Information

Similar documents
Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Facility Information

Sandusky State Theatre Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Arcadia Performing Arts Center Technical Specifications and Information

AKI STUDIO THEATRE Information and Technical Specifications

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Technical Specifications. Taylor Little Theater

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

Technical Specifications and Inventory Spring 2018

Technical Services and Specification

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Technical Data Sheet

Concert Hall Technical Specifications

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Marjorie S. Deane Little Theater

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Information

Technical Informa on.zack Theater

Concert Hall Technical Specifications

TECHNICAL PACKAGE.

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Specifications

SHUBERT THEATER 247 College Street, New Haven, CT

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Anvil Theatre. Technical Information

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE

Theatre Technical Specifications

The ACT Facility Technical Specifications Main Stage Information

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Information Packet As of October 2017

Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Dinkelspiel Auditorium - Technical Specifications

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Technical Specifications

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

2017 TECHNICAL SPECIFICATIONS

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

TECHNICAL RIDER. A full-scale diagram of the theatre can be downloaded at

Technical Specification

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Blue Bridge Repertory Theatre Technical Specifications

The Breen Center for the Performing Arts Saint Ignatius High School

Patriots Theater at the War Memorial Technical Data

CASA 0101 MAIN THEATER

Technical Specifications

Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Theatre Technical Specifications

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

CENTRE FOR PERFORMING ARTS

Mics, DIs, Stands, and Cables

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Dr JOHN GALLAGHER CONCERT CHAMBER

EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE

Main House Technical Specification

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

TECHNICAL INFORMATION

Weis Center for the Performing Arts

JERWOOD VANBRUGH THEATRE

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Performing Arts Theatre

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Jane Mallet Theatre Technical Specifications

NORTH CHARLESTON PERFORMING ARTS

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

JOHN W.H. BASSETT THEATRE

SAINT ANSELM COLLEGE DANA CENTER

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Technical Pack. Attenborough Arts Centre

DEREHAM MEMORIAL HALL

Technical Specification Pavilion Dance

Matt Dann Cultural Centre

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

NORTH CHARLESTON PERFORMING ARTS

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

THE STREET THEATRE. Technical Specifications

Z SPACE Technical Specifications. Stage & Rigging

Transcription:

General Information Box Office: 859.425.2550 City Gallery: 859.425.2562 Center Director: 859.425.2349 Technical Director: 859.425.2582 www.lexingtonky.gov/dac Address: Downtown Arts Center 141 East Main Street Lexington, KY 40507 Hours: Tues. Thurs. 10 AM 6 PM Fri. Sat. 10 AM 8 PM Sun. 10 AM 2 PM Owner: Lexington-Fayette Urban County Government Managed by: Lexington Parks and Recreation Center Director: Celeste Lewis clewis2@lexingtonky.gov Technical Director: Tom Willis twillis@lexingtonky.gov Box Office Manager: Ashlyn Swihart jswihart@lexingtonky.gov Parking Information Street parking near the DAC is monitored Monday through Friday 8 am 5 pm. Additional parking can be found across the street from the DAC at the Helix Garage, the Library Garage and the Phoenix Surface Lot. Helix Garage : $2 hourly, $8 daily rate, $3 after 5 pm, $3 Weekend Rate and free after 7 pm on non-event days. Library Garage : Validate for first Two hours, $1 per half hour, $8 daily rate. Phoenix Surface Lot : Available Free after 5 pm and on Weekends.

Loading - There is a severe incline approach to the single-bay loading dock, on the right side of the back parking lot (off Short St.). - Dock Height: 20.5 - Door Size: 9 11 x9 11 - Dock ramp: 36 x5 6 (500lb limit) - Handtruck: 600lb limit - 2@ furniture dollies (1,000 lb limit) - Maneuvering can be difficult for large vans and box trucks. Please call to arrange load in, and vehicle parking. Stage The Black Box Theatre is 53 x 52. The black painted, sprung oak floor cannot be screwed into. Sound baffling is hung around the space and can be adjusted as needed. The lighting grid hangs above the entirety of the room, above a walkable, tension wire grid. Deck to tension wire is 17 4. House lights extend 1 6 below the tension wire grid. See Rep Plot, and Riser Scheme documents for details. - ** A minimum of 44 must be allowed between installed set pieces and seating for means of egress. Marked emergency exits change depending on riser configuration. Please call with questions, clarification.** A/V Booth: The lighting, sound, and projection control booth is located on the mezzanine in the center of the south-west wall of the theatre. The sound proof windows look over the audience risers for a clear view in any audience setup. It is equipped with an audio monitor with the capability for backstage announcements. It is not usual to have the FOH mix position in the theatre. This can be arranged, but depends on riser configuration, and audience capacity. Dressing Rooms There are two dressing rooms near backstage (#1 can seat 10, and #2 can seat 8). Each has a bathroom, two sinks, a shower and seats at mirrors. Two rolling costume racks are provided for your convenience. A small green room is located across the hall. Each room has a ceiling mounted stage monitor.

Inventory: The Downtown Arts Center has the following inventory. Most items are available for use at no extra cost. The DAC TD can help determine what materials are needed/appropriate. For availability, or if you need equipment not in this list, please contact Tom Willis at twillis@lexingtonky.gov. Sound: Yamaha 01V Digital Mixing Board (16 channel) Playback - Mac Mini loaded with Qlab - Pro Video license only (CD/DVD reader available) - Sony Minidisk/CD Combo - ⅛ cable available for laptop/media device EV SxA100 Self-Powered Speakers (these are hung in different configurations, depending on riser configuration) EV Sb121a Self-powered Subwoofer (patched to Aux 4, located in corner of room) Fully integrated backstage monitoring system Telex SM-1 SoundMate Personal Listening System with 4@ belt packs 16x5 100 snake; patch stations are located throughout the theatre for convenience 3@ Shure SM-58; 2@ Shure SM-57; 2@ Wireless Handheld - ATW-R1100 4@ boom mic stands - 3 music stands 3@ Whirlwind direct boxes Assorted adapters and cable for sound equipment. Lighting: ETC Element 500 (with one monitor); a dedicated wireless network is setup for mobile app control. 26@ Roscoe/ET IPS Dimmer Bars (156 total dimmers, located on the grid) 4@ Roscoe/ET IPS Portable Dimmer Packs (24 total dimmers, can be used anywhere in the theatre) 2@ Roscoe/ET IPS Wall Mount Dimmers (12 total dimmer, all house lights) ETC Source 4 Ellipsoidal 36 Lighting Instruments - 72 ETC Source 4 Ellipsoidal 26 Lighting Instruments - 16 ETC Source 4 Ellipsoidal 19 Lighting Instruments - 10 Strand 6 Fresnel w. Barn Doors - 24 Gel frames to accompany every fixture listed; 24@ Gobo Frames (size B)

Assorted gel stock and jumpers Intercom: Headsets can be set up anywhere in the theatre, including the dressing room hallway, and above the lighting grid. - Telex MS2000 @ Channel Intercom Base Station - 10@ Telex BP 2 Channel Intercom Belt Packs - 10@ Telex PH-1 Intercom Headsets Projection: Screens: - 10 x9 (front and rear) - 12 x5 (front and rear) - Cyclorama can be used as a full stage projection surface (front only). Maximum width is 30 (with house projector). Projector: Infocus IN5110 - Zoom Lens - Throw Ratio: 2.9-1.5 Zoom Ratio: 1:1.93-4200 Lumens LCD - WUXGA 1920x1200 resolution - HDMI is primary source (cable provided). Accepts: VGA, BNC, RCA, S-Video, 2 audio ins, one audio out Source: - Mac Mini loaded with Qlab - Pro Video license only Rigging: Rigging in the theatre depends on load and location. Various equipment includes: - 1.5 Schedule 40 pipe (black) - various lengths - 1 Schedule 40 pipe (black) - 10 lengths as bottom weight - Rota locks - Cross clamps - Swivel cheeseboroughs - JR Clancy loft blocks

Soft Goods: Black Velour Legs: 8@ 8 x12, 6@ 12 x17 Full Blacks: 4@ 26 x17 (one set is rigged on a traveller system) Acoustic Blacks: 19@ 12 6 x7 9, 1@ 12 6 x6 8, 1@ 11 x6 4, 1@ 13 x2 8 (normally hung) Black Borders: 2@ 24 x2 (one is hung in line with traveller) White Scrim: 1@ 40 x17 Black Scrim: 1@ 40 x17 Muslin Cyclorama: 1@ 40 x17 Miscellaneous: 6@ 6 lightweight rectangular tables 3@ 60 round tables 10@ 30 round tables (30 or 42 height) 1@ wood lectern 6, 8, 12, 22 extension ladders available. **No hydraulic lift available.** Staging: 3 x8 platforms 3 x6 platforms 3 x4 platforms 1 x4 x8 step unit with handrail Various angled platforms * Heights available in 16 increments, up to 64. Availability based on installed riser scheme. Maximum Occupancies: Theatre 1st Floor Lobby 2nd Floor Lobby Community Gallery Rehearsal Room Tables & Chairs 180 50 30 60 100 Chairs Only 300 40 40 70 150 Standing Room 350 150 125 100 200 Risers 248