Using the HDCV Data Acquisition Program

Similar documents
Using the HDCV Analysis Program

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Analyzing and Saving a Signal

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

SigPlay User s Guide

Operating Instructions

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Data Acquisition Using LabVIEW

Oscilloscopes, logic analyzers ScopeLogicDAQ

MTL Software. Overview

Patchmaster. Elektronik. The Pulse generator. February 2013

The Measurement Tools and What They Do

Cisco Spectrum Expert Software Overview

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Getting Started with the LabVIEW Sound and Vibration Toolkit

PulseCounter Neutron & Gamma Spectrometry Software Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

4 MHz Lock-In Amplifier

Lab experience 1: Introduction to LabView

Table of Contents Introduction

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

EDL8 Race Dash Manual Engine Management Systems

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

The BAT WAVE ANALYZER project

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

EAN-Performance and Latency

Training Note TR-06RD. Schedules. Schedule types

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

PicoScope 6407 Digitizer

The most sensitive microelectrode array system for in vitro extracellular electrophysiology. Mobius Tutorial AMPLIFIER TYPE MED-A64MD1/MED-A64HE1

Virtual instruments and introduction to LabView

BTV Tuesday 21 November 2006

Universal Mode. Survey Settings. The Universal Toolbar. First Run - Initial Configuration via the Setup Button

potentiostat/galvanostat

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5

WaveView. and. WaveCal

Software Ver

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

imso-104 Manual Revised August 5, 2011

Fig. 1. The Front Panel (Graphical User Interface)

NI-DAQmx Key Concepts

TV Synchronism Generation with PIC Microcontroller

Getting started with Spike Recorder on PC/Mac/Linux

NI-DAQmx Device Considerations

Spectrum Analyser Basics

Viewing Serial Data on the Keysight Oscilloscopes

Pre-processing of revolution speed data in ArtemiS SUITE 1

Advanced Synchronization Techniques for Data Acquisition

IT T35 Digital system desigm y - ii /s - iii

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

PicoScope 6407 Digitizer

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Brain-Computer Interface (BCI)

Viewing Serial Data on the Keysight Oscilloscopes

Agilent DSO5014A Oscilloscope Tutorial

2 MHz Lock-In Amplifier

Experiment # 4 Counters and Logic Analyzer

Auxiliary states devices

CDHD Servo Drive. Technical Training Manual. Manual Revision: 2.0 Firmware Version: 1.3.x Software Version: 1.3.x.x

LeCroy Digital Oscilloscopes

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

FLIP-FLOPS AND RELATED DEVICES

User Manual VM700T Video Measurement Set Option 30 Component Measurements

Exercise #1: Create and Revise a Smart Group

User Manual. English. Sequencer Control Option BE3200. I en HBM: public

Chapter 23 Dimmer monitoring

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

Quick Reference Manual

Transmitter Interface Program

16 Stage Bi-Directional LED Sequencer

WELDING CONTROL UNIT: TE 450 USER MANUAL

Manual for the sound card oscilloscope V1.41 C. Zeitnitz english translation by P. van Gemmeren, K. Grady and C. Zeitnitz

WAVES Cobalt Saphira. User Guide

Model 2450-EC and 2460-EC Electrochemistry Lab Systems

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Supplement to the Operating Instructions. PRemote V 1.2.x. Dallmeier electronic GmbH. DK GB / Rev /

Major Differences Between the DT9847 Series Modules

Multi Channel Experimenter Manual

4.9 BEAM BLANKING AND PULSING OPTIONS

fxbox User Manual P. 1 Fxbox User Manual

Scanning For Photonics Applications

E X P E R I M E N T 1

Central Software Suite

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

Features/Specifications

BER MEASUREMENT IN THE NOISY CHANNEL

Introduction To LabVIEW and the DSP Board

imso-104 Manual Revised July 19, 2012

GVD-120 Galvano Controller

Eagle Business Software

Activity P32: Variation of Light Intensity (Light Sensor)

This guide gives a brief description of the ims4 functions, how to use this GUI and concludes with a number of examples.

Transcription:

Using the HDCV Data Acquisition Program This manual describes HDCV.exe, the data acquisition portion of the HDCV (High Definition Cyclic Voltammetry) program suite from the University of North Carolina at Chapel Hill. Contents Hardware pg. 1 Time and Terminology.. pg. 1-2 The Main Screen pg. 2-8 Basic Control Buttons. pg. 2 Experimental Control.. pg. 3-5 The Graph Area... pg. 5-8 Little Analysis.. pg. 8 Setup Hardware. pg. 9-11 Hardware Resources.. pg. 10-11 Setup Experiment.. pg. 12-20 CV Ramp.. pg. 12 CV Ramp Advanced pg. 13-14 STIM.. pg. 14-15 Analog Inputs... pg. 15 EPhys pg. 15 Digital Outputs. pg. 16 Digital Inputs. pg. 16 Analog Background Subtraction pg. 17-19 Compatibility. pg. 20

Hardware HDCV Data Collection is programmed to interface with the PCIe-6363 - X Series data acquisition card sold by National Instruments (visit http://www.ni.com/ for more information). This single card handles all digital and analog I/O s necessary for a wide range of experimental paradigms. Four analog outputs and 16 analog inputs support multi-electrode recordings and electrical stimulations. Forty DIO connections are available on the current breakout box design. This allows control over events such as an iontophoresis ejection or a flow cell injection. It also provides the ability to read timestamps during behavioral experimentation. Note that while HDCV will control the timing of combined electrophysiology/electrochemistry experiments, it will not record the electrophysiology signal. A separate computer and card are necessary for these experiments (See Takmakov et al. Rev Sci Instrum. 2011 July; 82(7): 074302). Breakout boxes for the PCIe-6363 are available for purchase by the Electronics Facility at the University of North Carolina Chapel Hill. If you wish to build your own box, wiring schematics are available by request. Time and Terminology The smallest unit of time in HDCV is the sample time. This is the interval at which each data point in the waveform is generated and measured, typically on the order of 10 microseconds. All other times used in HDCV are multiples of this one. Its inverse, the sampling rate, is a commonly quoted figure. Next is the interval at which the HDCV ramp is output. This is the frame time, typically 100 milliseconds. The time from the beginning of one ramp to the beginning of the next is one frame. Its inverse, the cyclic voltammetry frequency or CVF, is also commonly mentioned. The cyclic voltammetry scan only occupies a subset of the frame time. This is the scan, and its duration is the scan time. In the case that multiple different waveforms are being output on different channels, the frame begins when the first waveform begins, and the scan time runs until the last waveform ends. The remainder of the frame is the rest time. A common type of CV experiment consists of a series of timed events in which some stimulus is given and CV data are recorded for an interval before and after 1

that time. Each such event, with the recording of data, is one run. The entire series of runs, the largest unit of operation that HDCV will automatically control, is the experiment. There are also experiments that are run in continuous mode, where data is collected continuously throughout, and not broken up into runs. 1. The Main Screen The Main screen is divided into three major sections. The upper left region displays one of several graphs showing input data, regardless of whether a data collection session is in progress. The upper right region is where the user sets up and controls data collection experiments. The lower half of the screen, known as "Little Analysis," provides a preview of data recently collected. As the name implies, it is the little brother to HDCV Analysis, and provides a subset of its features. A few buttons at the upper left of the screen provides some basic controls. Basic Control Buttons Set up Hardware opens a configuration screen for dealing with the hardware. Here you tell the system what input and output channels you will be using, and for what purposes. Digital input and output lines are also configured here. If you move your experiment to a new machine, expect to need to give this screen a little attention. Set up Experiment opens the main configuration screen for your experiments. Here you will tell the system what signals to put out on your output channels, and how to interpret the data received on the input channels that you configured in Set up Hardware. When moving your experiment to a new machine, you should not need to change these settings. Exit ends a session of HDCV. The "Waveforms on" switch turns on the output of HDCV. When it is on, waveforms are being sent to the electrodes, and digital signals of the "Once per frame" variety are active, unless you have configured them to run only when an experiment is running. 2

Experiment Control The upper right area is for controlling your experiments. To specify a directory, click on the little folder icon to create or choose a folder in which experiment data will be stored. In the file dialog that pops up you may also type a file name if you wish. If so, it will be entered into the filename field. By default, if no action is taken, data files will be named data1, data2, etc. and will be stored in {user's home}\documents\labview Data, or wherever LabVIEW has been configured to store data files by default. If you run several experiments during the same HDCV session, the Filename field will be incremented automatically as each experiment ends. If the original filename ends in a number, that number will be increased by one. If it doesn't, a number will be added at the end. Along the top of the Experiment Control Panel you will find the option to collect in three different acquisition modes: 1. Single run. Data will be collected for one short session; a stimulation and/or TTL pulse(s) may be delivered at specified times during a session. If a Stim has been specified in Setup Experiment, schedule its onset in the time before STIM input box on the bottom left hand side of the panel. Beside this is the displayed stim duration, but you cannot change it here. This is calculated 3

from several factors set in Set up Experiment. 2. Multiple runs. Data will be collected in several runs, specified by a set downtime between runs during which no data are collected. Timed stimulation and TTL outputs may be delivered during each run. One.hdcv data file is generated, consisting of all the runs together. For multiple run experiments, you need to additionally specify: Number of run to be collected Length (s) of each run Time (s) between runs 3. Continuous. Data will be collected for one long session. No stimulation or other predefined event will be scheduled. This mode is designed for experiments on live, behaving animals, in which a stimulation and other events are likely to take place in response to digital inputs. Such an experiment can produce a very large.hdcv data file. A partner.dig file is written at the end of data collection as well. This file contains the timing of the digital input and output signals triggered during the collection session. Several additional controls and indicators are visible on the Experiment Control panel: Header Comments Time Indicator Start Button Stop Button Input any information you would like saved as part of the file header. The header can be accessed when opening the file in HDCV Analysis. This indicator is visible on the bottom right hand side of the panel. During data collection it marks the time elapsed since the beginning of the run or file. In multiple collection mode it counts down the time until the next run. Pressing this will begin your experiment. The clock starts, and the first (or only) run begins. The clock will count until the run ends. In a multiple run experiment, during the delay between runs, the clock will count down to the beginning of the next run. If If anything goes wrong, press this button to abort the experiment. A.hdcv will still be created; it may or may not contain any valid data for the run that was aborted. For Continuous experiments we try very hard to handle Stop in a manner that preserves the data. 4

Experimental Controls and Indicators Continued Pause Button Experiment in Progress Run in Progress STIM Run This is used for multiple run experiments only. It can pause the experiment between runs without aborting it. If you press it during a run, the clock will pause at the end of the current run. When pressed the Pause button will change state. Press it again to resume. The experiment will resume in such a manner that the delay created by the pause may perhaps be longer, but never shorter, then the delay between runs originally specified. This indicator appears green whenever an experiment is running. For multiple run experiments this includes the time between runs. When on, the Stop button is meaningful. This indicator appears green when a run is being collected and is off during a delay between runs. This indicator is on when a stimulation train is being delivered. This displays the number of the run currently being recorded or about to be recorded. It is only valid when the Experiment in Progress light is on. The Graph Area The graph area will display one of five graphs. These are meaningful whenever the "Waveforms on" switch is on. In order: Color Chart displays a continuous color plot style strip chart of the data being collected. To use background subtraction, click "Set BG". It will set the background to whatever is being collected at the current moment. If you don't like the results, wait until you see a better moment and click it again. Autoscale will change the color scale to make the color display as effective as possible for the data in view. Change the Chan selector to view a different channel in a multichannel experiment. 5

Data Point selects one data point per scan and graphs the current at that data point, as a continuous strip chart. If there are multiple channels you will see them all, viewed at the same data point. Choose that data point in the control below the graph to the left. Use the control to the right to designate how many data points in the CV scan should be averaged around this point for display. The small graph to the right of the strip chart is the oscilloscope view, showing one frame of data as currently collected. Press the Select button below it to go to the Line Selection screen, discussed below. Strip Chart is a rapid strip chart of data being collected. Though not useful to most users most of the time, it can be helpful for making sure that the system is live and collecting real data, because it tends to show motion even when the data are changing very little. 6

Scope is the oscilloscope view. It shows one frame of data, updated at the frame rate. It can display both input and output signals. Use the Pan and Zoom dials to view a portion of the frame in more detail if needed. The legend at the right shows the signals and their names. Use the Select button below it to go to the Line Selection screen and choose which inputs and outputs will be displayed. Those that are not currently displayed are grayed out in the legend. The Digital graph displays digital input data, on as many lines as you have configured to use. Like the Scope, it normally displays one frame. If your experiment has no digital lines configured, it will be blank. The Line Selection screen displays checkboxes corresponding to the various analog input and output lines in the current configuration. You can check them on and off to choose which lines to display in the Scope or Data Point graphs. The graph will update immediately as you change checkboxes. Press Done when satisfied. Don't be surprised if the vertical scale jumps radically as you turn 7

checkboxes on and off. This behavior is normal if you have Autoscale Y turned on for the graph. Little Analysis The lower portion of the screen is the little brother to the HDCV Analysis program, providing a quick preview of data recently collected. You may use it in two modes. "Current experiment" keeps it connected to the experiment in progress. The display will update as any run ends. For multiple run files, Little Analysis is the only way to view your data before your experiment ends. "File" allows you to load a file of your choice and view it, without interruption as the current experiment runs. "Current experiment" mode does not support Continuous mode experiments, as they would overload the capacities of Little Analysis. The ABS Capture button is used in conjunction with the Analog Background Subtraction feature, described above under Set up Experiment. All other features of Little Analysis behave just like the corresponding features of HDCV Analysis. Please read the Analysis manual for details. 8

2. Set up Hardware nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn In this screen you tell the system how it will be using its hardware. There are two primary modes: Simplified Setup and Manual Setup. Simplified Setup assumes that you are using the standard HDCV hardware: a 6363 card or something very close to it (perhaps a successor). In this case you only need to tell it how many of each resource you will need for each purpose, and it will allocate them according to the plan of the standard HDCV breakout box. As you specify each resource on the left, it will show you what it is allocating on the right. Manual Setup is for all other situations. A nonstandard breakout box, a nonstandard card, or other nonstandard usage. Use the menus to choose any single resource in any field. The menus will not help you select multiple resources. For this purpose use syntax like: Dev0/ai0:2 (analog inputs 0 through 2) or Dev0/ai0,Dev0/ai3 (analog inputs 0 and 3). No spaces around the comma! If you wish to designate non-sequential lines you will need to use Manual Setup. Note: HDCV uses analog inputs in Differential mode, which means that each input is paired with another one which serves as a reference. On a 6363, the 16 Differential mode analog inputs are numbered 0-7 and 16-23. How inconvenient. 9

To use more than the first eight of them, you will need to set up in Manual Setup. When you press the Done button to exit this screen, the program will actually try and allocate those resources, to see if it can be done. If it fails, you will see the error message without leaving the screen. If you find yourself stuck with an error message you can't understand, press Cancel. Hardware Resources CV inputs Non-CV inputs CV output ABS output STIM Voltage limits CVF Digital STIM Here you specify the channels for a multichannel CV experiment. If you have other signals in the system that you would like to record, that should not be interpreted as cyclic voltammograms, specify them here. Normally 0. Here you specify the channels on which waveforms will be output. More than one channel would be used in an experiment where different waveforms are being sent to different electrodes, probably to monitor different chemicals. Standard configuration: ao0-3 as needed. Analog STIM cannot be used when all four of these channels are configured as waveform outputs. Analog Background Subtraction is a special technique in which an extra output channel is used to carry a recorded background waveform, and external hardware subtracts it from the incoming signal. This allows for a very sensitive reading of the varying signal, the difference between the two. As of this writing, no more than one ABS channel is supported. The channel for the stimulation signal, if used. In the ultimate design of HDCV, a stimulation signal may be output through an analog channel or two digital lines. As of this writing, the digital version is not supported. Standard configuration: ao3. Specify here the hardware voltage range that will be used for the card, for all analog inputs and outputs. The maximum operating range of a 6363 is -10 to 10. Use narrower limits to provide a finer reading of a smaller signal. A signal at the scan frequency is always output on some digital line. It is high during the scan time and low during the rest time. Standard configuration: port0/line30. Not yet implemented. 10

Hardware Resources Continued: EP VCG Optional digital outputs Digital inputs For use in combined electrophysiological and electrochemical measurements. When selected, separate hardware can be used to record electrophysiological signals during the CV rest time. The EP output controls the relay that switches between the two sources. Standard configuration: port0/line31. Selecting this will output collection information through a serial port (or USB adapter) to an external video character generator. Two VCG boxes from Decades Engineering are supported: the XBOB-3 and the XBOB-4. When activated, the file name, date, time and CV scan number will display as text on the connected TV monitor. Can be set up to output either: a periodic signal that rises and falls once per frame; or, a signal that rises and falls once per run. Standard configuration: port0/line27 and downward. Digital data will be monitored and recorded on these lines. Commonly used in behaving-animal experiments, to record the timing of cues, lever out, stim, etc. Standard configuration: port0/line0 and upward. 11

3. Set up Experiment At the top of the screen are two numbers set apart from the rest: CV Frequency, and Sampling Rate. These set the fundamental timings of your experiment, and they pretty much control everything else. Apart from these, everything is organized into tabs. Here they are. CV Ramp Here you define the ramp, or output waveform, for your experiment. This simplified panel assumes that your ramp will be a symmetrical triangle wave, ranging from V1 to V2. Depending on choices you have made in Set up I/O, you may have more than one waveform to configure. If so, use the radio buttons at the upper left of the pane to choose which one you are working on at the moment. Also note the program uses the same number of data points to record each channel. This number will be based on your longest waveform. CV Ramp Parameters Phase shift Number of cycles Start delay Scan rate Data points per scan Offset Name measured in degrees, shifts the starting point in the wave how many times the wave will cycle from V1 to V2 and back time from start of frame until this waveform starts. Useful only when more than one waveform is present -- and they should not all be nonzero. Otherwise this violates the definition of the start of frame, which can only lead to confusion. measured in V/s. Changing this value will change the number of points per scan based on the value of the Sampling rate. changing this value directly will change the Scan rate based on the value of the Sampling rate. Change the Sampling rate to increase or decrease the number of data points without changing the Scan rate. this shift in voltage (input as mv) is used to compensate for observed shifts in voltage elsewhere in the system. if you choose to give your waveform a name, that name will appear in the waveform selector above, and in various places throughout HDCV and Analysis. 12

CV Ramp Parameters Continued Multiplier Duration of scan in order to get the most possible bits of precision out of the interface card, experimenters will sometimes set a multiplier to multiply the output voltage higher than the value actually desired, something close to the configured limit of the card. External hardware will be set to divide the voltage by the same number, restoring it to its true intended value. If in doubt, use 1. computed from Scan rate and Data points per scan CV Ramp Advanced This alternative panel for specifying waveforms allows a wider variety of choices. Waveforms may be chosen from several standard wave shapes, or customized. The scan rate cannot be specified here, but is rather computed from other parameters. Any choice other than the Triangle wave shape will cause the scan rate to disappear, because it is not a simple, single quantity. Additional options: Piecewise From file This type allows you to specify a waveform as a series of linear segments. Click the Edit button to open the editor. In the Voltage column type the voltage for each segment endpoint desired. In the Time column specify, between each two voltages, the number of milliseconds that should take place between them. If you find that you have entered more voltage numbers than you intended, click the [ - ] button to delete excess segments. After each change the graph will update. This type allows you to specify a waveform by loading a file. Press the Load button to choose a file. File format: a text file, a list of floating-point numbers, separated by spaces, tabs, and/or newlines. The number of numbers in the file will determine the number of data points per scan, and thus the duration of the scan. Such files can easily be exported from Excel and many other programs. Note: once the file has been loaded, it is the collection of points that have been loaded from a file, and not the filename, that is remembered to determine the waveform. Editing the text file will not change anything unless you explicitly Load that file again. 13

When toggling between the CV Ramp and CV Ramp Advanced tabs, HDCV will highlight the edge of the one that is active. Make sure this is correct before reentering the main collection screen. STIM Here you set up the form of the stimulation signal. This will be a square wave, a train of a specified number of pulses. The pulse train that you specify must fill an exact number of frames. It won't have four pulses each for two frames, and then to pulses left over in a final frame. This boils down to the following rules: Stim frequency must be a multiple of CVF, and the number of pulses must be a multiple of (Stim frequency / CVF). You also want to be sure that the Stim signal never coincides with the CV ramp signal. The graph on the right shows stim and all ramps in a representative frame, and it will warn you: any part of the ramp signal that overlaps a stim signal will be highlighted in red. The Combined Waveform Graph at the bottom shows the entire Stim pulse train, together with CV ramps that take place during it. Stimulation Parameters: Frequency the frequency of pulse delivery in Hz Amplitude measured in V0p Pulse length the length of each individual pulse in ms # Pulses the total number of pulses time between the start of a frame and the start of the first Stim Start Delay pulse. Use this to make sure that Stim pulses and CV ramp never overlap. Duration calculated from the total duration of the stimulation pulse train Polarity This describes the form of the pulses: Monophasic (+) the pulse goes positive Monophasic (-) the pulse goes negative Biphasic the pulse goes positive for (pulse length) time and then goes negative for (pulse length) time, then returns to zero. NOTE: this makes a total pulse that goes twice as long as Pulse length. 14

Stimulation Parameters Continued Triggering Bursts controls when the stimulation happens: Internal stim happens at a set time after the start of a run. External stim happens when the specified DIO line (digital input) makes the specified transition (Rising or Falling). Turn on the Rising button to specify the Rising transition, otherwise it will be Falling. stimulation may be specified as a series of bursts, i.e. pulse trains as specified above. Burst frequency tells how often a new burst will begin. NOT IMPLEMENTED. Analog Inputs You can specify a name for each of the CV and other inputs. If you do, this name will be used on the labeling of graphs throughout the HDCV system. You can also specify: Gain Using waveform a conversion factor between volts measured and the current indicated supports experiments that involve multiple waveforms and multiple CV input channels. Each waveform may be applied to more than one input channel, and here is where you tell the system about that oneto-many relationship. EPhys (electrophysiology) The EPhys signal is used in experiments that use the electrode to do double duty: during the CV rest time, the electrode is used to do electrophysiology measurements, controlled by separate hardware. This signal controls the relay that switches between the two sources. Here you may specify the "dead time" on either end of the CV ramp before the relay switches. During this dead time voltage is applied to the electrode, but the current is not recorded. This is desirable to prevent any switching transient from interfering with the CV data. 15

Digital Outputs These are your programmable digital output lines. Can be set up to output either: a periodic signal that rises and falls once per frame; or, a signal that rises and falls once per run. In the case of "once per frame" signals, you can specify that the signal is only emitted during a run, and falls quiet between runs or while no experiment is taking place. For "once per frame" signals, the rise and fall times will be less than or equal to one frame time. For "once per run" signals they will probably be many times one frame time. The resting state of the signal will be based on Rise or Fall, whichever comes last. "Once per run" signals are useful for controlling the valve in a flow cell experiment. Digital Inputs Here you may name your digital input lines. If you do, these names will appear in graph labels throughout the HDCV system. 16

Analog Background Subtraction Analog Background Subtraction (ABS) is a special technique used to neutralize the recorded charging current of the electrode, which is usually much larger than the faradaic signal of interest. ABS is performed by making a recording of the original background current and then applying it to the inverting input of the headstage amplifier. By removing the contribution of the charging current to the recording, the voltage limits of the cards can be reduced in Setup Hardware to decrease quantization noise (see Hermans et al. Anal Chem. 2008. 80(11): 4040-8). Note that the ABS signal is only applied during the timeframe of the voltage scan. Therefore a large capacitive spike occurs each time the ABS output is applied. To prevent this current artifact from overlapping with the waveform, you will need to add 50-100 points of holding potential to the beginning of the scan. This can be done by using the Piecewise or Load from File options in the Advanced CV tab. Any extra points can be deleted later during data analysis (see Data Point Removal in the Analysis Manual). The image below shows an example of how a modified dopamine waveform with 100 buffering points is built with the Piecewise feature. The time column is in units of milliseconds on this screen, and the number of data points per phase is the time (s) multiplied by the sampling rate (Hz). 17

Unlike all other parts of the HDCV system, ABS involves a feedback loop. Therefore, you won't usually enter the ABS tab in Setup Experiment directly. Instead, here is the procedure: 1. Design a waveform with extra data points before your desired voltage scan. 2. After conditioning your electrode with your waveform, collect a short run to obtain a sample background. 3. Once the file is finished, view it in Little Analysis with filtering and background subtraction off. 4. Move the white cursor to a position that represents the background, to your satisfaction. The option, "Columns to average for CV" is effective. 5. Press the ABS Capture button. A file with the name of the current experiment and an extension of ".ab" will be created in your data directory. 6. You will be taken to the Analog Background Subtraction tab in Set up Experiment. The new background will show in the Captured Background graph. 7. Press the "Use captured" button to transfer this new information into the actual working background. Set the Scale Factor to 1 divided by the gain of your ABS circuitry. If you purchased your hardware from UNC the gain usually is around 200 na/v (but not always), giving you a Scale Factor of 0.005. The Scale Factor can also be used to solve a Voltage out of range error if you get one. Keep in mind that the amount of current you can subtract is limited by the ABS gain. For instance if the ABS gain is 200 na/v with a ±10 V DAQ, the maximum current you can apply is ±2000 na. 18

8. Once you ve captured the ABS signal, exit Setup Experiment and go back into the Setup Hardware screen. Change the Number of ABS Outputs to 1. The program designates AO3 as the output line by default. When you apply the waveform again you should see a drastic reduction in the background current. 8. Make adjustments. Use the DP shift to adjust the timing of the analog background. It will be shifted by the specified number of data points (sample times). This is useful to avoid glitches at the beginning or end of the scan caused by misalignment of the background and the CV input. If the background current has not been zeroed to your satisfaction, repeat steps 2-6 to make additional background recordings. When you enter into the ABS tab use the Add captured button instead of the Use captured button to sum the.ab files. Recorded charging current (white trace) before and after analog background subtraction 19

Compatibility This feature is for those who may be using HDCV with an old breakout box. It supports the switching of an external valve in a flow cell experiment, by using the STIM output to represent one digital output line. Tell it what voltage you want to use for a High state, it will use zero for Low. A signal will be output that corresponds to whatever you specify for the first Digital Output. 20