SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Similar documents
2178-L/S Series Fiber Optic Splice Case with Gasket

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

TECHNICAL SPECIFICATION

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

INSTALLATION INSTRUCTIONS

Gel-sealed in-line fiber optic closure

SPECIFICATION. Spec No : VSS-1402-CS603B

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Better Buried Compound Compression Closure System

FOSC 450 C6 and D6 Closures

Instruction manual. Midi Fiber Dome. Instruction manual

SLiC Fiber Aerial Closure System

3 SLiC Aerial Closure with Rubber End Seal

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

27mm ECAM Double Cable Entry Port

3M Distribution Box (DDB)

3M Better Buried Closures

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

18mm ECAM Cable Entry Port

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

Fiber Optic Splice Closure GPJ Instruction Manual

HCS - HES Cabling Systems

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

2178 L/S Series Fiber Optic Splice Cases and Accessories

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

Public Works Division Lighting District Fiber Optic Specifications April 2009

Water blocking tape. Locator ridge HPA-0486

Medium Box for Cable Termination

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Optical Distribution Box 300 Installation Guide. Version : R0.0

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Fiber Optic Wall Mount Enclosure 8430 Series

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

Customer-Owned Outside Plant

Fiber Optic Closure. Fiber Optic Splice Closure For Aerial Line. Model : W-ICL-007-xxF. Features

Instructions. Cable with Armor F CAUTION. October Rev A

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

FusionLink Central Tube Ribbon Preparation & handling procedure

FOSC-450 Product Range Ordering Guide

INSTALLATION INSTRUCTIONS

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Splice Closure Fiber (SCF) Family

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Revision No. 4 Page No. Page 1 of 7

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

3M Fiber Optic Closure System LL

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

FOSC 400 A4 Fiber Optic Splice Closure

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

SLiC Fiber Aerial Closure 533 and 733

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

DOME OPTIC SPLICE CLOSURE

VITALink Taped Splice Straight Through Crimp

Installation Instructions

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

TECHNICAL SPECIFICATION

The FiberMark1 offers an ideal solution for

3A TC 699/SIP/UK/12

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Installation of Optical Fiber

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

3M Fiber Closures BPEO

FOSC 400. Fiber Optic Splice Closures

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

IP-LINX. Installation Guide

K & B Flame Retardant Building Riser Closures

3M Fiber Optic Splice Closure 2178 Family. Flexible Fiber. Management Solutions

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

Panduit Recommended Best Case Practice Split Fibre

Flexible Fiber Management Solutions

SPECIFICATION. Optical Fiber Cable

FREEDM Loose Tube Interlocking Armored Cables

UNSIGNED HARDCOPY NOT CONTROLLED

ELECTRICAL SAFETY INSPECTION REPORT

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Transcription:

Fiber Optic Splice Closure

1. Introduction 1.1 General SAMJIN s SJOF-BS604B protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct buried applications. The flat type gasket ensures reliable sealing performance by preventing air and water leak and the corn type sealing socket provides easy and reliable installation. This closure has high mechanical strength against any environmental conditions. With SAMJIN s SJOF-BS604B, you can improve your network system to the higher level. 1.2 Specifications BS604B Size (mm) L W H 174 x 211 x 522 Weight (kg) 2 No of Entry Ports 6 Ports Cable Dia.(mm) 8 ~ 24 No. of Splice Tray 4 Tray Capacity Splice Capacity Splice Method 12F 48F Fusion, Mechanical, Connector 2/11

1.3. Configuration B E H A C F I D K G J L M N O Items Descriptions Unit Q ty Remarks A Outer Body SET 1 B Splice Tray EA 1 Standard C Steel Clamp Plate SET 1 D Cable Inlet Port EA 1 E Splice Tray Band EA 1 F Grounding Wire SET 6 G Steel Band EA 2 H Unit Protection Tube EA No. of Splice Trays 2 I Aerial Hanger EA 2 J High Vacuum Grease EA 1 K Band Clamp SET 1 L Sheath Gasket EA 3 M Silica Gel EA 1 N Cable Tie EA No. of Splice Trays 4 O Splice Protection Sleeve EA - Optional 3/11

2. Direction 2.1. Getting Started 2.1.1. Confirm the cable structure and the fiber type before starting the work. Different types of fibers cannot be spliced together. 2.1.2. Seal the splicing part perfectly to minimize cable damages by moisture. Do not apply any impact to the splicing part. 2.1.3. Keep the working place free from moisture or dust. Do not give any impact on the cables. Do not bend or twist cables. 2.1.4. During the sheath stripping and the closure assembly procedures, use permitted tools according to an approved fiber optic splicing standard in your region. 2.2. Cable Preparation 2.2.1. Secure the cables firmly on the working table. 2.2.2. Cut off about 1m from the cable end including the pulling eye. 2.2.3. Clean the cut area with clean cloth. 2.3. Marking a Cutting Point 2.3.1. Mark a sheath removing point on the cable with a piece of tape at a 150cm point from the cable cut end. (Figure-1) [Figure-1] 4/11

2.4. Sheath Removing 2.4.1. Remove the cable sheath from the marked point by using a sheath stripper. (Figure-2) Note. Be sure not to damage the fiber optics. 2.4.2. Remove all plastic tape and dummy filler tubes. (Figure-3) 2.4.3. After trimming off dummy filler tubes, clean the loose tubes by using jelly cleaner. [Figure-2] [Figure-3] 2.5. Cutting Tension Member (T/M) 2.5.1. Leave 14cm from the cable and cut off the tension member. (Figure-4) Note. Be careful not to cut loose tubes. 2.5.2. Remove PE coatings from the tension member if required. [Figure-4] 2.6. Cutting Cable Inlet Ports 2.6.1. Measure the cable diameter by using cable ruler. 2.6.2. Select the appropriate cable inlet ports. (Figure-5) [Figure-5] 5/11

2.6.3. Cut cable inlet ports less than 3mm length from the end of the applicable ports by using saw or equivalent tool. (Figure-6) [Figure-6] 2.7. Inserting Sheath Gasket 2.7.1. Cut the sheath gasket according to the cable diameter. (Figure-7) 2.7.2. Insert the cable into the sheath gasket from the loose tube end after applying high vacuum grease on the cable sheath. (Figure-8) [Figure-7] [Figure-8] 2.8. Inserting Cables 2.8.1. Insert the cable into the inlet port from the loose tube end with sheath gasket. (Figure-9) Note. The surplus loose tubes are not to be cut and can be used later. [Figure-9] 6/11

2.9. LAP Grounding (if required) 2.9.1. Insert a LAP grounding wire tab deeply into the LAP sheath and clamp the cable sheath tightly with the other tab attached to the grounding wire by using pliers. (Figure-10) Note. There is no need to do additional job for tension member grounding. Grounding Wire [Figure-10] 2.10. Removing Loose Tubes 2.10.1. Leave about 4cm from the cable sheath end and remove the rest of the loose tube. (Figure-11) 2.10.2. Clean the cut area by using jelly cleaner. Note. Be sure not to damage the fiber optics. [Figure-11] 2.11. Inserting Unit Protection Tube 2.11.1. Insert fibers into the unit protection tubes carefully all the way up to the point where loose tubes end and wrap the tape around the end point of protection tube at cable side. (Figure-12, Figure-13) Note. The unit protection tube is provided in different colors for unit identification. The colors are blue, orange, green, red, yellow and violet. Unit Protection Tube [Figure-12] [Figure-13] 7/11

2.12. Fixing Tension Member 2.12.1. Put the T/M (tension member) supporter cover on the T/M and tighten them together by using a screwdriver. (Figure-14) 2.12.2. Fasten the cable on steel clamp plate by using steel band to be provided. (Figure-15) Note. When fixing the T/M, the T/M should not touch the splice tray for safety. [Figure-14] [Figure-15] 2.13. Arranging Unit Protection Tubes 2.13.1. Arrange the unit protection tubes considering the bending radius. 2.13.2. Insert the unit protection tube into the inlet on the splice tray and fix the unit protection tubes by using cable ties. (Figure-16) Note. Be careful not to damage the inner fibers [Figure-16] 2.14. Splicing and Storing Fibers 2.14.1. Preparation 2.14.1.1. Clean the working desk and check the fibers carefully. 2.14.1.2. Cut each fiber end carefully to make a perpendicular cut to the fiber axis. 2.14.2. Splicing 2.14.2.1. Splice fibers in accordance with splicing method to be approved. Note1. Be careful not to twist or bend fibers. Note2. There should be no damage or flaw on the cut area and keep the fibers from dust to minimize the data loss. Note3. Single mode fibers should be spliced together carefully to maintain a constant center axis. Note4. If there is any problems with the splice, then cut the splicing point and splice them again. 8/11

2.14.3. Arranging the splices 2.14.3.1. After the splice, insert the splice protection sleeve in each slit accordingly. 2.14.3.2. Coil surplus fibers in the tray in a figure 8 shape. (Figure-17) 2.14.3.3. After the arrangement, apply the O-ring into the slit and close the tray lid. 2.15.4. Record each splice on the index card on the lid. (Figure-18) [Figure-17] [Figure-18] 2.16. Stacking Splice Trays 2.16.1. Place the tray cover on the tray properly and stack the trays by using the connection parts on the side and repeat the splicing procedure. 2.16.2. After putting silica gel, tie the splice trays by using splice tray band to be provided. (Figure-19) [Figure-19] 9/11

SJOF-BS604B 2.17. Assembling the Closure 2.17.1. Place the dome shaped outer body onto the bottom portion. (Figure-21) Note. Check the status of silicon gasket ring inserted in the slit of the dome shaped outer body. 2.17.2. Fasten the dome shaped outer body and the bottom portion together by using band clamp. (Figure-22) [Figure-22] [Figure-21] 2.18. Mounting the Closure 2.18.1. Aerial Mounting 2.18.2.1 Connect two hangers to the body with bolts and nuts. (Figure-23) 2.18.2.2. Hang the closure on the wire properly by using aerial hangers. (Figure-24) [Figure-23] [Figure-24] 2.19. External Grounding 2.19.1. Connect the external bonding wire to the ground terminal on the closure and connect the opposite end of bonding wire to a designated terminal. (Figure-25) Ground Terminal Bonding Wire [Figure-25] 10/11

The OPTICUBE has been made under strict quality control and tests. Our products passed several inspection criteria, specifications and other certification standards. The technical facts of the products are based upon reliable information, but the user should consider the usage and applicability of the product before operation. Sellers do not assume any liability resulting from improper use. The contents of this manual are made in lieu of all warranties, but sellers do not take the responsibility for any damage caused by users or any statements unrelated to this manual. SAMJIN Information & Communications Co., Ltd. 235-2 Deokpyeong-ri Majang-myeon Icheon, Gyeonggi-do Korea 467-812 Web: http://www.samjintel.co.kr Email: sales@samjintel.co.kr Tel: +82-31-716-7858 Fax: +82-31-716-7844 SAMJIN OPT-M0505 Printed in Korea 11/11