Multi Functional CCTV Tester Rapport III

Similar documents
Multi Tester. Multi Tester. Rapport III / Rapport III-PRO. Rapport -10HD/PRO. Rapport Mini Professional CCTV Tester Rapport. Image.

OPERATING INSTRUCTIONS TOM-0431IP

PROFESSIONAL GRADE TOOLS THAT ARE EASY TO USE REVOLUTIONARY TECHNOLOGY (YOU CAN AFFORD) BYTE BROTHERS 2010 PRODUCT CATALOG

Quick Operation Guide of LTN7700/7600 Series NVR

P XGA TFT Monitor. User s Manual

User Manual Color video door phone

SM-10 SAT Level Meter User s Manual

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

PRO-3GSDIHDMI. 3G-SDI Extender with HDMI Scaler OPERATION MANUAL

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

Fluke 279 FC True-rms Thermal Multimeter

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

Certificate of Calibration

RS Part No Instruction Manual Solid State DVR. (Single Chanel for Mobile) SSD01CA

Instructions for Use: Video Inspection Scope with Display

COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual

User Manual Color Video Door Phone

CP-255ID Multi-Format to DVI Scaler

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

SUPERSCALE Multi-Format to HDMI Scaler

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

PS600 Digital Visualizer. User Manual. English - 0

Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using.

M-CT6 Camera-Top Monitor

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

CMSDI G-SDI Matrix

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

COLOR TFT LCD MONITOR. Manual

User Manual. 7" Portable On-camera LCD Monitor DT-X71H DT-X71C. Model: DT-X71F HDSDI&HDMI, Waveform, Audio meter, Focus assist HDSDI&HDMI HDMI

Jinyoung Contech Co., Ltd.

16-CH Color Full Duplex Multiplexer Instruction Manual

Satellite locator WS-6933

COLOR TFT LCD MONITOR. User Manual

CP-255ID CV, SV, VGA and DVI to DVI Scaler / Converter OPERATION MANUAL

BSM-093N3G / BSM-173N3G BSM-183N3G / BSM-213N3G BSM-243N3G / BSM-463N3G BSM-553N3G BSM-212i / BSM-242i

Monochrome Video Monitors

PC/HDTV to Video Scan Converter Operations Manual

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

CSLUX-300I Multi-Format to HDMI Scaler

BBV REAL TIME HQ DISPLAY QUAD MANUAL

L1900J L1900R L1900E. User s Guide

Clamp 200 A AC/DC (+ V AC/DC + Ω)

User Manual Color video door phone

Model P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide

Camera 220C Document Camera User s Guide

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

23.6 & 27 & 32-INCH TFT-LCD IP PUBLIC VIEW MONITOR

P-2 Installing the monitor (continued) Carry out as necessary

HITACHI. Instruction Manual VL-21A

PRO-SDIVGA. SDI Extender with PC/HD Scaler & Audio OPERATION MANUAL

SATELLITE FINDER SK-3200 USER MANUAL

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Model: S-1071H(EFP) 7" EFP Field On-camera LCD Monitor. User Manual. Please read this User Manual throughout before using.

User Manual. Color video door phone CDV-40Q

SHENZHEN NOYAFA ELECTRONIC CO.,LTD

VL35 QUICKSTART GUIDE. 3.5" 4K HDMI Field Monitor w/ Canon LP-E6 Battery Plate

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

S7H-DK S7H 7" High Bright Monitor Deluxe Kit

Dell D3218HN. User s Guide. Regulatory model: D3218HNo

DH5e-V2. Delta 5 On-Camera 4K HDMI Monitor with 3D LUTs. Quick Start Guide. What s Included

UTP TRANSMITTER & RECEIVER SUT-80/SUR-10 USER S MANUAL ENGLISH

VITEK VTM-TLM191 VTM-TLM240

Stratos Duo RGB. User Manual. Order code: EQLED371

Marshall. M-CT5 Camera-Top Monitor Owner s Manual M-CT5. Camera-Top Monitor. Owner s Manual

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

CSLUX-300I Multi-Format to HDMI Scaler

1CHDVRD1 USER MANUAL. These instructions apply to unit model 1CHDVRD1 only. Please read carefully before use.

Model: DT-X92H 2. 9 Rack Mount Broadcast 3GSDI LCD Monitor. User Manual. Ver:V1.0.0V01. Please read this User Manual throughout before using.

EL-5500 Advanced HDMI/VGA Presentation Switch OPERATION MANUAL

LCD VALUE SERIES (32 inches)

INSTRUCTION MANUAL. 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B VSPA19LCD-AE1M VSPA19LCD-AE1W. Model No. FINGER TOUCH TECHNOLOGY RATED

Quick Reference Guide

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

9" Portable On-camera LCD Monitor. User Manual. Model: DT-X91F HDSDI&HDMI, Waveform, Audio meter, Focus assist DT-X91H 3GSDI&HDMI DT-X91C HDMI

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

PRECAUTIONS CONTENTS: Please follow these precautions:

USER MANUAL Full HD Widescreen LED Monitor L236VA

CSLUX-300 Multi-Format to HDMI Scaler

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Winmate Communication INC.

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

Multi-format to HDMI scaler ID#15107

Telemetry Receiver Installation Guide

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

17" & 19" Color TFT LCD Monitor

28 4K LED monitor. User Manual M284K

Owner s Manual. TFT-LCD TV High Brightness & Contrast NICAM/A2 Stereo Sound MODEL: L15SV6-A0, L17LV6-A1,L20AV6-A0 L17L6A-G1,L20L6A

TFT LCD MONITOR USER MANUAL HMDE Series 104AV-HMDE 121AV-HMDE 151/152AV-HMDE 156AV-HMDE, 171/172AV-HMDE 185AV-HMDE 191/192AV-HMDE 215AV-HMDE

DH5e QUICKSTART GUIDE. 5" 4K Support HDMI On-Camera Field Monitor w/ Touch Screen

HOME GUARD USER MANUAL

USER S MANUAL CCTV LED MONITOR MODEL: ADE-117N1 ADE-119N1 ADE-118W1 ADE-121W1 ADE-124W Atherton Electronics Corp. All rights reserved.

3G-SDI 4 by 4 Switcher

Transcription:

Multi Functional CCTV Tester Rapport III RAPPORT III / Rev.01/1 Feb.2011 P/N : 88087140 PRINTED IN KOREA

TABLE OF CONTENTS TABLE OF CONTENTS Information... 4 Before Using Rapport III... 5 Safety Information... 6 Product Introduction... 10 Major functions of Rapport III... 10 Standard item... 11 Introduction... 12 Product Specification... 18 General specification... 18 Meter specification... 19 Functional Specification... 20 Power ON/OFF... 20 Mode setup... 21 Video tester... 22 function... 25 Digital multimeter... 4 controller... 8 UTP cable tester... 41 Symbols Drawing...... 4 44 02 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 0

INFORMATION BEFORE USING RAPPORT III General Rapport III is a Portable Service Monitor & Multimeter with a built-in.5 inch digital monitor. It s a simple and convenient multi-functional measurement and test tool which provides monitoring and analytical data when installing CCTV systems Product Functions Video Input and Output Multimeter (Voltage and Resistance) Cable Test (UTP) Control Video Storage Function (, Rapport III - PRO) Operating Temperature: -10 ~ 50 Relative Humidity: 0% ~ 90% Recharge Voltage: 12V ±10%, 1.2 A or above *Normal operation: Without using and Multimeter General Be sure to read through the "Safety Information" section before using this Rapport III. This basic instruction manual is for users of the Rapport III. Starting with an outline of this Rapport III, the manual explains its operation,how it connects to other devices, how to use the menu buttons,and how it should be operated. It is highly recommended, even for those who have handled similar devices, as well as for those using it for the first time, to read all the instructions thoroughly, especially the precautions, before using the Rapport III. If there are any questions which arise when using the Rapport III or the unit is damaged, please contact the supplier of your Rapport III. Safety Information highlights and explains the precautions which should be taken, for the safety of Users, when using the Rapport III. Introduction to the Rapport III, explains the available features and appearance. Specifications of the Rapport III, explains the specification of the Rapport III. Functional Use, details the functions of the Rapport III and explains their uses. *The Rapport III and Rapport III Pro support the same basic functions, but the Rapport III does not include the function. 04 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 05

COM + SAFETY INFORMATION SAFETY INFORMATION Precautions The following describes how to safely operate the Rapport III. Please read carefully the precautions for use of this product prior to using this device. Check the input and output ranges of any voltages being applied to all inputs and outputs of the device, and ensure their connections have been made properly so no abnormal load is placed on the operation of the device. If the measurement value is unknown when measuring a resistance, set the Rapport III meter to its maximum value so that no abnormal load is placed upon the device. The Rapport III should only be used under the environmental conditions shown in the specification where temperature and humidity figures should be adhered to. Before using the multimeter function for circuit testing, always disconnect all Video In/Out connections made to any other external devices. Connecting the Test Lead Set to a circuit for testing, with these connections made, causes them to use a common grounding path and could result in damage to the device. 5 VOLT MONITOR DC POWER SUPPLIES Precautions Pay attention to the following precautions when using the Rapport III. Do not use the unit in damp, humid or gaseous environments. Do not touch it with wet hands. Be mindful not to shock or shake the unit while in use to avoid damage. Avoid areas with strong magnetic or electromotive fields, which can cause incorrect measurements or operability. Do not expose the ports or joints to dirt or liquids. Do not disassemble the Rapport III. Do not use the meter function, if the Rapport III or the Test Lead set look damaged. Do not measure resistance when power is applied to a circuit. When using the meter function, do not forget to turn on the power to the Rapport III and use the correct measurement range before connecting to a circuit to be measured. Turn off the power to the circuit under test and discharge all high voltage capacitance before starting resistance or continuity tests to avoid damage to the Rapport III. Place fingers behind the protecting pad when using a test probe. 06 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 07

SAFETY INFORMATION SAFETY INFORMATION Precautions Battery Charging Precautions The Rapport III has a built-in Lithium Polymer Battery. It can be recharged using a DC12V power adapter with an output of 1.2A or above and reaches its full charge after a period in excess of 6 hours. After the battery has been fully charged for the first 2~ charging cycles, it can be used for approximately 6 hours (up to a Max.8 hrs in normal operation). The battery can be recharged by connecting it to the DC adapter, regardless of OSD power, when the slider switch has been turned on. Precautions Battery Handling Avoid short circuits, as this will cause internal damage to the battery. The soft packaging can easily be damaged by contact with sharp surfaces or objects, take care when handling or storing. The sealed edge adjacent to the battery contacts is a very sensitive area; take care not to bend or fold the edges. Do not open the folded edges. Do not bend the tabs are these are breakable. Avoid mechanical shocks to the battery. Do not immerse the battery in water. Only use the supplied battery charger or one with a safety guarantee. Stop charging immediately if the battery is overheating, emitting a burning smell, changed in colour or distorted. The discharge operation starts when the Main Switch is turned on and it then consumes power from the battery. Therefore, when the Rapport III is not being used for a period of time, make sure the Main Switch is turned off. Keep away from static electronic fields while using, charging or when storing. Do not disassemble; the battery is not a serviceable item. Never short circuit the positive and negative poles of the battery. Do not charge the battery in ambient temperatures above 40ºC/104ºF. 08 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 09

PRODUCT INTRODUCTION PRODUCT INTRODUCTION Summary Designed, with portability and serious CCTV engineers in mind, the Rapport III is an advanced piece of video test equipment consisting of many useful test functions needed to professionally install a CCTV system; test functions include Video Level, Service Monitor, Multimeter, UTP Test, Test, RS-422 and RS-485 Communication Test, etc. Major Functions of Rapport III Video Testing Tests whether a video image is present, and its quality, by displaying the image on the built-in.5 Digital Monitor. Conducts and displays the Video Level (IRE test) of the image. Video signal generator Mode : It outputs a Colour Bar which allows the engineer to test a video monitor or. Rapport III supports both PAL & NTSC video signal format. Function (This funtion is only supported by the Rapport III-PRO) Store the video input on to a SD Card and play it back. Meter Functions for testing voltage, resistance and short circuits. Protocol Analyzer It determines which protocol controls a camera from a Controller or. This helps the CCTV Installer to understand the protocol and find faulty devices. Standard Items Check the contents of your Rapport III package against the standard checklist below : Rapport III Main Test Unit SD Card (2Gb Storage) - (optional, Rapport III-PRO) Test Lead Set (1 x Red Lead, 1 x Black Lead ) Rechargeable Lithium Polymer Battery (7.4V 2000mA) UTP Test Terminal - Dongle Test Lead Set (Red, Black) BNC Video cable Safety Strap SD Card * SD Card is provided to Rapport III- PRO only. SD D Power Adaptor Rapport User s Manual User Manual Power Adapter (DC12V) Safety Strap BNC Video Cable UTP Tester Termial Rapport III- PRO Rapport III Package UTP Cable Testing Test the integrity of connection conditions of a Category 5e UTP cable. Checks for continuity or short circuits. Tester Carry Bag RAPPORT Bag RAPPORT 10 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 11

PRODUCT INTRODUCTION PRODUCT INTRODUCTION Introduction Rapport III (without function) The Rapport III and Rapport III-Pro support the same basic functions, but the Rapport III does not include the function. BNC Video Input BNC Video Output UTP Input RS-485 In/Out LED Indicator The LED turns Red or Green depend on the recharging status. On charging : RED LED ON Fully charged: GREEN LED ON SD Card Slot LED Indicator When operating the Rapport without an adapter. On operating: RED LED ON Low battery : RED LED flickers on and off Control Pad Power Input DC12V Item Power LED RED LED GREEN LED Remark Test Lead Port Main Power Switch Charging mode Charging Fully charged Charging error ON OFF OFF OFF ON OFF Adaptor connected Operating mode Operating Low battery ON Flicker OFF OFF Adaptor disconnected *This is for power LED status when the power switch is ON. 12 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 1

PRODUCT INTRODUCTION Rapport III-Pro Part Name Function 1 2 4 FAR 10 SET OSD PWR 10 NEAR TELE WIDE OPEN V CLOSE CLEAR AC/ DC/ FILE REC PLAY 5 Key Button 6 Key Button LCD POWER Data Transmitting LED Data Receiving LED Button SET Button OSD Button FAR Button NEAR Button TELE Button WIDE Button Shift Setup Button Voltage Button Resistance Button Setup Change Button FILE REC PLAY 7 Test Lead Connection COM V/ TFT LCD Red LED is on when the OSD POWER is on Red LED is on when Data is Transmitted Red LED is on when Data is Received For Controlling External Devices i.e. Rapport III Used to Change Setup OSD Selection It toggles OSD & POWER on/off Adjusts Focus (Far Direction) & Increases Video Image Brightness Adjusts Focus (Near Direction) & Decreases Video Image Brightness Zooms (Zoom In) & Increases Video Image Contrast Zooms (Zoom Out) & Decreases Video Image Contrast Moves Up, Down, Right, Left & Also Used for Menu Functions METER Measures Voltage Measures Resistance Changes setup Between AC & DC, Resistance/continuity Test Image data list for SD card (Rapport III-PRO) Record Video (Rapport III-PRO) Playback Recoded Video (Rapport III-PRO) Test Lead Connection Positions Position of Black Test Lead, Common Ground (-ve) Position of Red test Lead for Measuring Voltage & Resistance (+ve) Rapport III PRODUCT INTRODUCTION Part Name Function 1 LCD TFT LCD 2 POWER Data Transmitting LED 4 Data Receiving LED SET FAR 10 OSD PWR 10 NEAR TELE WIDE OPEN V CLOSE AC/ DC/ IRE 5 Key Button 6 Key Button Button SET Button OSD Button FAR Button NEAR Button TELE Button WIDE Button Shift Setup Button Voltage Button Resistance Button Setup Change Button IRE 7 Test Lead Connection COM V/ Red LED is on when the OSD POWER is on Red LED is on when Data is Transmitted Red LED is on when Data is Received For Controlling External Devices i.e. Rapport III Used to Change Setup OSD Selection It toggles OSD & POWER on/off Adjusts Focus (Far Direction) & Increases Video Image Brightness Adjusts Focus (Near Direction) & Decreases Video Image Brightness Zooms (Zoom In) & Increases Video Image Contrast Zooms (Zoom Out) & Decreases Video Image Contrast Moves Up, Down, Right, Left & Also Used for Menu Functions METER Measures Voltage Measures Resistance Changes setup Between AC & DC, Resistance/continuity Test Measures Video Level Test Lead Connection Positions Position of Black Test Lead, Common Ground (-ve) Position of Red test Lead for Measuring Voltage & Resistance (+ve) 14 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 15

PRODUCT INTRODUCTION PRODUCT INTRODUCTION 1 2 1 2 4 4 Part Name Function 1 2 4 Input BNC Output BNC Communication Port Safety Strap Input for External Video signal Outputs the Screen Displayed on the Rapport III, or the Internally Generated Video Test Signals Connections for RS422 and RS485 Input & Output (Rx+, RX-, TX+, Tx-) Used to Carry the Rapport III Safely Part Name Function 1 2 4 DC Power Jack DC Power Input Jack (DC12V, 1.2A) Power Switch ON/OFF Main Power Switch UTP RJ45 Jack Test Jack for UTP cable SD Card SD Card Slot (Rapport III-PRO) 16 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 17

PRODUCT SPECIFICATION PRODUCT SPECIFICATION General Specification Meter Specification Input Voltage 12V ±10%, above 1.2A Mode Range Minimum Measuring Accuracy Electrical Characteristics Battery Built-in Charger Charging Time Operation Time Lithium Polymer Battery (Inner packaging) More than 6 hrs More than 6 hrs (Max.8hrs) DC Voltage 400mV 4V 40V 100uV 1mV 10mV ±(2.5% +4dgts) ±(2.5% +4dgts) Image Operation Test TV Type Image level Protocol Transmission Speed Transmission Mode NTSC/PAL 1Vpp, 140 IRE Multi 2400bps ~ 115.2Kbps RS-422, RS-485 AC Voltage 00V 100mV 4V 1mV 40V 10mV 00V 100mV 400Ω 0.1Ω ±(2.5% +4dgts) (40Hz ~ 500Hz ) ±(2.0% +4dgts) UTP Cable Test Tests Continuity/Crossed Cable, and Breaks or Short-Circuit 4 kω 1Ω Size W(88mm) X L(126mm) X D(40mm) Resistance 40kΩ 10Ω 400kΩ 100Ω ±(2.0% +2dgts) 4 kω 1 kω ±(2.0% +4dgts) 40 kω 10 kω ±(.0% +5dgts) Continuity Beeper is activated when the resistance is below 80Ω 18 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 19

Power ON/OFF Use a DC12V Power Adapter and connect it to the DC Jack. Turn the Rapport III ON/OFF by using the slider switch located on the side of the product. After switching the power switch to the ON position, press the OSD button and the Rapport III will boot up. To turn the Rapport III OFF, keep the OSD button depressed for at least 2 seconds and wait until a POWER OFF message is displayed on the Main Screen. Release the OSD button and turn off the ON/OFF slider switch; power is now turned off. When charging the battery, keep it on charge for more than 6 hours or until the unit is fully charged. On full charge the operational time is approximately 6 hours. (Max.8hrs) If the battery indication shows less than you need to recharge the battery. (Full recharge state: ) Initial Screen en Display at Power On Mode setup The OSD menu changes whenever the key is pressed, and sequences through in the following order : VIDEO METER - CABLE - SETUP The SELECT menu is displayed when the key is depressed and moves to the next menu whenever the key is pressed SETUP USER NAME : RAPPORT-III SLEEP TIME: 5Min BUZZER : ON LOSS VIDEO METER CABLE SETUP RAPPORT RAPPORT III FW Version : 0.0 After the power is applied the above on-screen message is displayed. Approximately 2 seconds later the screen switches to the last OSD before power was turned off. The Rapport III stores the last accessed OSD. The initial OSD message displays the Rapport's firmware level. Versions of the product change whenever new firmware is uploaded. Video Tester Mode : This function displays the image of an externally input video signal, or is used to output internally generated signals when in PATTERN GENERATOR mode. (Rapport III-PRO only) : Used to record (onto SD Card) and playback input video images. Digital Multimeter mode : Tests voltage, resistance, & continuity. Controller mode : This function allows up, down, right and left movements of a camera to be made. Also, zoom & manual focus can be adjusted. UTP Cable Tester mode : Tests UTP cable connectivity tests for straight & crossed cables, for breaks and short circuits. Main Setup mode : This function allows changes to be made to the basic setup of the Rapport III (user name, auto power off time, beeper etc). 20 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 21

VIDEO TESTER Connect the output terminal of video output system to the video input BNC of Rapport III. Connect the video output BNC of Rapport III to the video input terminal of system. Level VIDEO IRE: OmV BRIGHT 07 CONTRAST 07 COLORBAR CLR On PAL mode, the video will be displayed in IRE. OSD Screen Setup VIDEO : Indicates that the Rapport III is in video test mode. Whenever there is a video input, in video test mode, the video level is automatically displayed. On NTSC mode, the video will be displayed in mv. Understanding Video and Sync Level Rapport III / Rapport III PRO measures the combined Luminance and Burst levels of a composite video signal as the Video Level. The Sync signal is embedded between the Luminance and Colour Burst signals. See the following chart for a description of the levels that are expected. VIDEO NTSC PAL C B IRE: OmV BRIGHT COLOR BAR 07 CONTRAST 07 VIDEO NTSC B IRE: OmV BRIGHT COLOR BAR 07 CONTRAST 07 BACK FORMAT Go back to the Video mode Toggle the video type between NTSC and PAL NTSC Luminance Level Colour Burst Level Video Level 100 ± 10 IRE 40 ± 5 IRE 140 ± 15 IRE BACK FORMAT CLR BACK FORMAT CLR CLR Clear OSD Sync Level Luminance Level 40 ± 5 IRE 700 ± 140 mv Video and Testing : By default the Video will be displayed in the top portion of the screen. If there is no video signal at the VIDEO IN port of the Rapport III /Rapport III-PRO LOSS will be displayed. Depending on the type of camera connected to the tester the Video and Sync level will automatically change between IRE (Institute of Radio Engineers) and mv. NTSC signals that are used in North America are measured in IRE units, PAL signals that are common throughout the rest of the world are measured in mv (millivolts) PAL Colour Burst Level Video Level Sync Level 00 ± 5 mv 1000 ± 175 mv 00 ± 5 mv 22 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 2

SD SD The Video Level should be within the indicated range. Levels that are too low will result in a dim picture with reduced dynamic range. A Video Level that is too high will result in washed out pictures with decreased definition. The Sync Level controls the drawing of each line on the monitor. Sync Levels that are too low will cause the picture to breakup or roll while Sync Levels that are too high will result in a picture with reduced grey colours and dynamic range. In an installation with multiple cameras, the video and sync levels should be matched as closely as possible at the head-end to prevent noticeable picture quality differences when switching between cameras on a sigle monitor. Values outside the recommended tolerances can cause the operators to experience eye fatigue. VIDEO : Indicates if the input or output video signal system is NTSC or PAL. Input video signal is output onto the LCD screen and automatically switches to NTSC or PAL without using a special setup key. The output video signal when in Pattern Generator mode can be switched to NTSC or PAL, using the SET key. BRIGHT 07 Indicates screen brightness, and brightness increases by +1 when the FAR key is pressed, and decreases by -1 when the NEAR key is pressed. It returns to the initial setup value when either of the two keys is depressed for more than seconds. CONTRAST 07 TELE Indicates screen contrast, and contrast increases by +1 when the key is pressed, and decreases by -1 when the WIDE key is pressed. It returns to the initial setup value when either of the two keys is depressed for more than seconds. Introduction to the Function (Rapport III-Pro) ( ) 1. Selecting the mode causes the (Rapport III- PRO) to initially boot up and after 2~ seconds the start menu is displayed. FILE : 1 Booting... IN VIDEO METER CABLE SETUP RapportIII-Pro supports the function. 1 1 : Indicates Mode. 2 NTSC : Indicates NTSC or PAL System. Indicates Screen Mode. Shows REC ( ) when in record and PLAY ( ) when in playback, otherwise will display LIVE for real time images. 4 FILE NO : Idicates recoded file number. 5 EMPTY : No SD card installed. IN : SD card has been installed. 6 : Change the mode. 6 FILE : 1 IN 4 5 2 24 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 25

SD ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST FUNC MENU 15 001 001 01 SETUP DATA SD SD SD SD 2. Basic Operation Recording video : Support 8 files with 10minute each. 1) Video Storing Function SD card slot - Input SD card: Input a SD card pre-formatted to a FAT2 format. OSD changes EMPTY - Remove SD card : Remove the SD card after power off or move to another mode and remove it. - Lock SD card : When the SD card is locked, recording and playback functions are not supported. IN FILE : 2 IN - Select file number. (EX. FILE 2) REC FILE : 2 IN 00:00 Designate the file storage location using the Up & Down buttons. Pressing the REC button starts the recording process and REC is displayed. Press the button to stop recording. FILE : 1 IN FILE : 1 EMPTY FILE : 1 LOCK SD CARD IN SD CARD OUT SD CARD LOCK Button Key for function SET : Confirm the setting of each function (=ENTER key). DIRECTION KEY ( ) :Set the file, speed of playback. STOP( ) : Stop recording & playback. FILE : To check the recorded video file. CLEAR : Delete the recorded video. REC : Record the video image. PLAY : Playback the recorded video. FILE : 2 IN Record There is a option for recording a video file. UPDATE FILE : 2 Press the REC button and "UPDATE FILE" is displayed. YES NO SET Select YES and press the button to start video recording. If another video clip has already been stored in the selected file location the message "UPDATE FILE" is displayed. The existing file is deleted and the location updated with the new video clip when the quick menu is selected. 26 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 27

SD SD SD SD 2) Video Playback 4) Check Recorded File FILE : 2 IN FILE : 2 IN SD CARD FILE INFORMATION Shows the SD Card files, and their recorded file size. FILE1 : 12MB FILE5 : FILE2 : 19MB FILE6 : FILE : FILE7 : FILE4 : FILE8 : - Designate the file storage location by using the Up & Down keys and press the PLAY button. The play mode ( ) is shown with the video. To stop playback press the button. - Use the Left and Right keys to adjust playback speed. Options are 2x, 4x, 8x or 16x. )Delete Recorded File FILE : 2 IN FILE : 2 IN CLEAR FILE : 2 YES NO * CLEAR FILE : 5 YES NO Press the button, is shown on the LCD Screen with a Clear File message. Select YES or No using the keys and press the SET button. The recorded file is delected. The file deletion can be checked by pressing the FILE button (If the file has been deleted, "Empty" is displayed). 28 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 29

How to playback the video file on a PC. Installation (Setup) Please contact the manufacturer or your local agent to obtain the download details for the Rapport III-Pro PC playback software program. Supported PC spec. & O/S ITEM CPU Main Memory O/S* Web Browser Resolution Network Min. Requirements Pentium III 800 256 MB Windows 2000 I.E 5.0 1,024 X 768 100Base - T Ethernet Recommended Specifications Above Pentium IV 2.0G Above 256MB Window 2000 or XP, VISTA, WINDOWS 7 Above I.E 5.0 1,152 X 864 100Base - T Ethernet 1 Select language => Click NEXT 2 Setup the program 2. Supported O/S Windows 2000 Professional Windows XP Windows 2000 Server Windows VISTA Windows 7 (2 bit only) License => Select agree 4 Setup Status 5 Setup Complete => Click Finish button 0 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 1

4. AKR Player Screen You will find the icon on your PC desktop after program set up. Precautions Insert SD Card as shown in the picture. Click the icon and AKR Play Screen starts. Click the icon and find the video file you want. Please make sure power is off before inserting the SD Card. The SD Card label should be on the reverse side when inserted into the Rapport III-Pro. The SD Card could be damaged if incorrectly inserted. Insert SD card SD D 1 2 4 5 1 Select file. 2 Click the file. The file will playback. 4 Use the right mouse button to define the image size. 2 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER

W A R N I N G 1. DO NOT unplug the SD card during recording. 2. Stop recording or playback before powering off the system.. DO NOT use the function when there's a Low Battery warning. Description of Meter Function LCD Window 1 2 4 5 METER LOSS DC AC OHM VOLT BUZZ DCV -0.000V DCV--0.001V STORE 6 Digital Multimeter Voltage, resistance and continuity can be tested. W A R N I N G To prevent electric shocks, injury, or damage to the Rapport III, disconnect the power supply to the circuit under test, and discharge all high-voltage capacitors before testing resistance and continuity. When using the meter function of the Rapport III, make sure the unit is switched on and set to the appropriate test mode before connecting the test lead set to the circuit under test. Setup Keys CLOSE CLEAR Press the button to measure resistance; pressing the AC/ DC/ button changes from the OHM scale to BUZZER (for continuity testing). OPEN CLEAR Press the V button to measure voltage; pressing the AC/ DC/ button causes the measurement range to toggle between ACV and DCV. Part Function Description 1 2 4 Type of Test Set Up Test value Displayed Measured Graph Value Measured Value on Hold - Resistance Test - Continuity Test - DC and AC Voltage - Unit of resistance Test - Indicates either the AC or DC Voltage Range - AC Voltage is indicated as RMS (Root Mean Square) Values - The Measured Input value is Displayed in the Form of a Graph - The Graph is Changed Automatically and is Equal to the Measured Value - OVER is Displayed When the Measured Value is Higher Than the Setup Value The Measured Value is Stored and Displayed Here When the SET Key is pressed 5 Display Digital Multimeter Mode is displayed 6 DC AC DC Voltage Test AC Voltage Test OHM Resistance Test ( Measuring Unit : Ω ) VOLT Voltage Test ( Measuring Unit : V ) BUZZ Continuity Test ( Starts to beep when below 80Ω ) 4 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 5

Measuring Resistance The unit of resistance is the Ω. The meter sends a low current into the circuit so that the resistance can be measured. This current runs along all paths between the two probes and enables the total resistance to be calculated. METER Continuity Testing How to measure : Connect the red lead to and the black lead to, as shown in the figure to the left, and measure the resistance and measure the resistance directly. Continuity means the presence of a complete path for current to flow. The continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display. How to test : Resistance mode DC AC OHM VOLT BUZZ OHM OVER STORE METER DC AC OHM VOLT BUZZ OHM OVER STORE METER STORE DC AC OHM VOLT BUZZ OHM OVER changes to continuity mode, when the is pressed. The beeper is activated when the resistance between the red and black probes is less than 80Ω. Measuring AC & DC Voltage Voltage is the difference in electrical potential between two points. The polarity of an AC voltage varies with time, while DC polarity is constant. The meter displays AC voltage as RMS values (root mean square readings). The RMS value is the equivalent DC voltage measured in a time varying sinusoidal signal. METER LOSS DC AC OHM VOLT BUZZ ACV 0.018V STORE C METER LOSS DC AC OHM VOLT BUZZ DCV+ 12.2mV STORE C STORE Change Mode Fix and show the current value. How to measure : Press the voltage measuring button, and then select AC or DC by pressing the button. When DCV is being measured, place the red lead on +ve side and the black lead on -ve side of the voltage source. 6 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 7

Controller How to connect each terminal and LCD screen Operation Test : Performs basic operational movements; Up, Down, Left, Right, Zoom, and Manual Focus. It also tests various protocols and their transmission speeds. In order to control a, connect the communications cables to TX terminals of the Rapport III. ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK FUNC 01 MENU - Control Setup Screen DATA ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK ADD Setup Screen Protocol Setup Screen Communications Speed Setup Screen @Receive Data BACK CLEAR SETUP DATA @Receive Data BACK CLEAR FUNC 01 MENU - Keyboard Controller Code Screen. Rx+ Pressing this button displays the received data. FUNC 01 MENU - The controlling protocol from the keyboard or the is displayed on this screen. More important, however is that the communications speeds are matched. Rx- ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK FUNC 01 MENU How to Control a Camera functions - Up, Down, Left, Right movements are carried out using the SETUP Buttons. Focus and Zoom adjustments are made using the FAR/NEAR (Focus) and TELE/WIDE (Zoom) buttons. Function Setup of the Use the SETUP keys to adjust GPST / SPST / FUNC / SET SPD and MENU settings (displayed on the lower part of the LCD screen) by pressing the SET key once. GPST (GO TO PRESET) : Moves the camera view to a designated preset location; Presets are numbered 000 to 255. The cursor moves to the GPST SET position when the key is pressed. Select the previously stored PRESET number using the & keys (move by+1, -1 step). Once selection is complete, press the SET key once more and the camera will move to the PRESET location. SPST (SET PRESET) : Sets and stores PRESET information in the range from 000 to 255. First, move the camera to the required view and press the SET key, and use the & keys to place the cursor at the location of the chosen preset. Then set up the address where the preset is to be stored SET by using the & keys, and press the key once more. The location information is now stored as a preset address. FUNC : Follows the FUNC set up using the SPST and MENU information. The Setup range is from 00 to 6. It can be set by +1, -1 step by using the & keys. SPD (SPEED) : Move the cursor to the SPD icon, using the procedures described above. A total of 16 increments in speed (1 to 16) are available for selection using the & keys. MENU : Place the cursor at the MENU location, using the procedures described above. The MENU of the can be displayed on LCD screen, using the SET key. When set the above funtions, it can be set by +10, -10 steps by using FAR the, keys. NEAR 8 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 9

C A U T I O N UTP CABLE TESTER 1. Make sure to check the communication protocol, transmission speed, and ID. 2. The input signal from the controller can be checked when the communication line is connected to the Rx terminal of the Rapport III. Control Setup of The ADDR menu bar is accessed, on the top section of the LCD screen, SET when the key is depressed for more than seconds. The activated menu can be changed to PROTOCOL and BAUDRATE by pressing the & keys. CABLE LOSS NO CONNECTION TEST TEST Change the mode Check the cable type by pressing the SET button. ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE GPST SPST 001 001 ADDR : Setup the ID. The default value SPD is 001. To change the ID use the & keys. 15 keys and it moves by +1, -1 steps. The available values are 001 through to 255. OK FUNC MENU 01 Connect the UTP cable to be tested to the UTP port of the Rapport III, and connect the other end of the cable to the yellow UTP test dongle. PROTOCOL : Used to set the PROTOCOL. The default value is set to PELCO-D. To change to another protocol, use the & keys to see the available protocols. BAUDRATE : Sets the TRANSMISSION SPEED. The default value is 2.4Kbps. Use the & keys to alter the speed the available options are from 2.4Kbps~ 115.2Kbps. PARITY : Set the parity to NONE, ODD and EVEN by using & keys. ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK FUNC MENU 01 FUNC MENU 01 Once the connection is complete, the connectivity of the cable under test is checked by pressing the SET key. Straight through and crossed cables can be verified. Disconnections and short-circuits are also displayed. CABLE (1) XXXXX (X) (2) XXXXX (x) () XXXXX (X) (4) XXXXX (X) LOSS NO CONNECTION TEST (5) XXXXX (X) (6) XXXXX (x) (7) XXXXX (X) (8) XXXXX (X) CABLE STRAIGHT (1) (1) (2) (2) () () (4) (4) TEST LOSS (5) (5) (6) (6) (7) (7) (8) (8) CABLE (1) () (2) (5) () (7) (4) (1) CROSS TEST LOSS (5) (2) (6) (4) (7) (6) (8) (8) C A U T I O N Check the CAMERA ID, PROTOCOL and BAUDRATE settings prior to testing. A camera cannot be controlled unless all three settings are correct. ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 OK FUNC MENU 01 Short-circuit & Disconnection Straight cable Cross cable 40 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 41

TABLE 1 - SYMBOLS SETUP USER NAME : RAPPORT-III SLEEP TIME: 5Min BUZZER : ON LOSS VIDEO METER CABLE SETUP SETUP Mode Select : To access this menu depress the key and select the SETUP icon. Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys Number 1 2 4 Symbol Reference IRE 60417-501 IRE 60417-502 IRE 60417-50 Description Direct current Alternating current Both direct and alternating current Three-phase alternating current 5 IRE 60417-5017 Earth (ground) TERMINAL SETUP LOSS USER NAME RAPPORT III Selecting the USER NAME initiates an editing menu and shows the associated key strokes. 6 7 IRE 60417-5019 IRE 60417-5020 PROTECTIVE CONDUCTOR TERMINAL Frame or chassis TERMINAL 012456789()ABCDEFGHIJKLM NOPQRSTUVWXYZ!@#$% & +-+<> 8 IRE 60417-5021 Equipotentiality BACK STORE CLEAR 9 IRE 60417-5007 On(Supply) SETUP LOSS USER NAME : RAPPORT-III SLEEP TIME: 5Min BUZZER : ON SLEEP TIME: Select sleep time by using the & buttons. The options are OFF, 1, 5, 10, 0, 60 minutes. 10 11 IRE 60417-5008 IRE 60417-5172 Off(Supply) Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION BUZZER: Select ON/OFF by using the & buttons. 12 1 IRE 60417-5041 Caution, rick of electronic shock Caution, hot surface SLEEP TIME makes the power go OFF automatically, unless button is pressed. **The equipment shall not be used for measurements of categories II, III and IV. **If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. MULTI FUNCTIONAL CCTV TESTER 42 MULTI FUNCTIONAL CCTV TESTER 4

DRAWING (mm) MEMO MULTI FUNCTIONAL CCTV TESTER 44 MULTI FUNCTIONAL CCTV TESTER 45