ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE E0.01
FIRST FLOOR DEMOLITION E1.01
10 E2 11 12 12 G2 14 15 D1 D2 17 18 18 19 1 2 3 4 19 21 1 3 2 4 5 1 3 2 4 5 7 6 7 A2 E1 C2 A2 H1 H2 A1 E1 E2 6 8 A1 11 C1 14 16 17 5 19 8 16 9 10 13 6 9 11 14 17 7 10 12 G1 8 16 13 15 18 13 10 CYC ELECTRIC 20 22 20 22 21 23 ELECTRIC #3 20 22 ELECTRIC #2 21 23 ELECTRIC #1 Revisions: SECOND FLOOR DEMOLITION E1.02
THIRD FLOOR DEMOLITION E1.03
FIRST FLOOR E2.01
CYC ELECTRIC ELECTRIC #3 ELECTRIC #2 ELECTRIC #1 Revisions: SECOND FLOOR E2.02
ETCNet ETCNet ETCNet LCD TOUCH MONITOR LCD TOUCH MONITOR 2 FADW 2X20 FADER WING MODEL-GIO @5-24K GIO @5-CONTROL CONSOLE, 24,576 OUTPUTS PART # 4390A1016-US 14' NET CABLE ECPB-NET/NET/AC PLUG-IN STATION (BOOTH) SINGLE PHASE, 2 WIRE + GND 120V, 50/60 Hz. 20A MAX. (BY OTHERS) EQUIPMENT RACK LOCATED IN ROOM 3336 24-PORT PATCH PANEL BLANK 24-PORT SWITCH WITH PoE UNISON ERn2r ARCHITECTURAL CONTROL UNIT 1 - P-ACP 1 - P-SPM 1 - URTO 1-RSN-TERM 1-N3GA-RM UPS SENSOR SR3-48 1 - CEM3 MODULE 1 - SPARE CEM3 22 - TR20 MODULES 26 - R20 MODULES WITH RIDETHRU OPTION 7140K1001 TO NORMAL CIRCUITS (TYP OF 96-20A 2-WIRE CIRCUITS) UNISON ON & OFF STATION UNISON ON & OFF STATION SINGLE PHASE, 2 WIRE + GND 120V / 60 Hz. 20A MAX. 7-BUTTON STATION LOCATED AT CONTROL CONSOLE (PORTABLE) UH10005 (TYP OF 3) DAISY-CHAIN CABLE FROM STATION ON WALL BEHIND CONTROL CONSOLE TABLE. RACK "DR" TO NET PLUG-IN STATION NET3 ONE-PORT OUTPUT TOURING GATEWAY TO DMX CONTROLLED FIXTURES 3 PHASE, 4 WIRE + GND 120 / 208 VAC 600A MAX. 60Hz. (EXISTING) Revisions: RJ-45 JACK PROVIDE A TOTAL OF 6 ONE PORT GATEWAYS AND 2 FOUR PORT UNDESIGNATED SPARE GATEWAYS. BELDEN 9729 DMX CONTROL CABLE WITH NEUTRIK CONNECTORS. BELDEN 8471 QYT (3) LOCATED IN ELECTRIC POWER DISTRO STRIP OR OUTLET BOX. SEE CONNECTOR STRIP SCHEDULE ON SHEET E2.02 FOR QUANTITY. CAT 5 CABLE 2_#18 GAUGE WIRES EACH HEX NOTE SYMBOL REPRESENTS A CABLE RUN NOTES: 1. ALL ELECTRICAL TERMINATIONS, WIRE AND CONDUIT TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL DEVICES IN DRAWINGS AND SCHEDULE LISTED IS TO BE RECEIVED BY THE ELECTRICAL CONTRACTOR AND STORED IN A SECURE, DRY LOCATION. ALL DEVICES ON RISER TO BE PLACED, MOUNTED AND INSTALLED BY ELECTRICAL CONTRACTOR. 2. ALL LOW VOLTAGE TERMINATIONS AND PROGRAMMING BY INTEGRATOR/FACTORY ENGINEER. 3. ARCHITECTURAL CONTROL STATIONS USE BELDEN 8471 TYPE U CONTROL WIRE. ARCHITECTURAL STATIONS ARE TOPOLOGY FREE. MAXIMUM CABLE RUN IS 1,500'. 4. ALL ETHERNET CABLE IS A HOME RUN TO EQUIPMENT RACK, DO NOT EXCEED 100 METERS INCLUDING PORTABLE PLUG-IN EXTENSION WHEN APPLICABLE. FIBER CABLE M9B023 MUST BE USED OVER 100 METERS 5. SYSTEM INTEGRATOR BASIS OF DESIGN IS ETC, PROVIDED BY SESCO LIGHTING AND SHALL SUPPLY ALL CONTROL, DIMMING AND PROGRAMMING. 6. SYSTEM INTEGRATOR SHALL HAVE ACCESS TO ALL FIXTURE TYPES AND TEST WHERE REQUIRED FOR DIMMING PERFORMANCE. 7. SYSTEM SHALL BE FIELD PROGRAMMABLE AND TOUCH SCREEN SHALL SHOW ALL FIXTURES AND ALLOW END USER RECORDING OF PRESETS. 8. COORDINATE WITH SYSTEM INTEGRATOR FOR LOW VOLTAGE TERMINATION'S AND PURCHASE OF LIGHTING CONTROL, DEVICES AND SPECIALIZED CONTROL. SYSTEM INTEGRATOR SHALL TERMINATE ALL LOW VOLTAGE CONNECTIONS IN SYSTEM SHOWN. SYSTEM INTEGRATOR SHALL PROGRAM A BASE OF OPERATION AND ASSIST THE DESIGN TEAM IN ALL PROGRAMMING. SYSTEM INTEGRATOR SHALL HAVE ON SITE PRESENCE DURING CONSTRUCTION TO COORDINATE CONTROL, DIMMING, SYSTEMS SYSTEM INTEGRATOR SHALL BE RESPONSIBLE FOR A COMPLETE WORKING SYSTEM. THE SYSTEM IS BASED ON ELECTRONIC THEATRE CONTROLS, INC., AND /OR UNISON SYSTEMS. 9. THE BASIS OF DESIGN IS ELECTRONIC THEATRE CONTROLS, INC. INFORMATION IS AVAILABLE AT WWW.ETCCONNECT.COM. THIS SYSTEM IS DESIGNED IN ACCORDANCE WITH INFORMATION FROM THE ENGINEER AND OWNER. NONE LIGHTING CONTROL DIAGRAM E3.01
NONE PANEL SCHEDULES AND PARTIAL ONE LINE DIAGRAM E4.01