Client Project name Order# Type Qty FEATURES AND BENEFITS Physical : Aluminum optical chamber housing Anodized aluminum flush trim Polymer recycled PVC blockout housing Available in, 2, 3 or 4 sections Die cast aluminum end caps Stainless steel hardware Frosted glass lens IP68 rated for up to (30cm), not suitable for permanent immersion applications IK0 rated 000kg max load, walk over only* CERTIFICADO No.0884, 088 RETILAP IK0 Performance : Color mixing option: RGB (3 channels) Lumen maintenance 80,000 hrs [L70 @ 2 C] Lumen maintenance 60,000 hrs [L70 @ 0 C] Lumen measurements comply with LM - 79-08 standard Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM) Operating temperatures: -40 C to 0 C [-40F to 22F] 4ft full white RGB Performance summary Delivered Output [lm] Intensity [peak cd] 23 8 Electrical : Line voltage luminaire for 00 to 277V Power and data in cable (#6-) IP68 push-lock connectors 6W/ft DMX/RDM enabled Width of glass lens 2 [8mm] 3, 2 6 ", 37, 49 [33mm, 636mm, 94mm, 24mm] 7 4 [3mm] FRONT VIEW *All dimensions are preliminary SIDE VIEW 9 [4mm] 8 2 " [2mm] SECTION DETAIL Power supply housing *To meet 000kg walk over resistance requirements, cement must support 00% of the exterior surfaces of the blockout. / Copyright Lumenpulse 206.877.937.3003 -year limited warranty. Consult
ACCESSORIES Order separately, refer to each item s specification sheet for ordering information Control Systems: Control Boxes: LTO2 LCU LID LTN CBX Lumentouch is a wall mount DMX 2 controller keypad. Lumencue is a USB / mini SD DMX 2 controller. LumenID is a diagnostic and addressing DMX 2 controller. It must be specifi ed on all DMX applications. Refer to LID specifi cation sheet for details. Lumentone is a simple pre-programmed DMX 2 controller with a push button rotary dial and live feedback. DMX/RDM control box. Up to six power and data outputs to fi xtures or fi xture runs. Ethernet enabled option. Refer to CBX specifi cation sheet for details. Cables (required): LOILC LOIJC Leader Cable for Lumenfacade Inground;0, 2 or 0 [3m, 7.6m or.2m] standard lengths Jumper Cable for Lumenfacade Inground; 2, 4 or 0 [0.6m,.2m or 3m] standard lengths Inground Junction Box (optional): Lumenfacade Inground IP68 sealed junction box starter kit - LOI-JBOX order code. *Use for stand alone fixtures and/or first of run fixtures 2/ Copyright Lumenpulse 206.877.937.3003 -year limited warranty. Consult
TYPICAL WIRING DIAGRAMS Typical Installation with Leader Cable American Color Code CE Color Code USE Green Yellow/Green Ground Black Brown Live White Blue Neutral Red/Purple Black 0-0V / Data + Orange Grey 0-0V / Data - Leader cable Jumper cable to next fixture (For daisy-chain installation) Blockout Conduit Typical Installation with IP68 LOI-JBOX Accessory Cannot be used with ft LOI fixture LOI-JBOX Power & data input cable Jumper cable to next fixture (For daisy-chain installation) Blockout Conduit 3/ Copyright Lumenpulse 206.877.937.3003 -year limited warranty. Consult
TYPICAL WIRING DIAGRAMS - continued Star Layout (DMX/RDM) Jumper cable Jumper Cable Length Selection Add the length of one fixture to the distance between two fixtures: L + D. CBX-ST (4 ft LOI shown) Order the next longest jumper cable available: 2, 4 or 0 [0.6m,.2m or 3m] Ex: L + D = 4.ft [.4m] Data input Lumentouch 2.0 distance between two fixtures Ex: 0. ft [0.m] (D) length of fixture (L) Therefore 0 [3m] jumper cable required IP68 LOI-JBOX Accessory - Wiring Detail 00-240V Combined power & data input (From CBX, cable by others) Cap Cable to Maximum 32 DMX/RDM enabled fixtures per DMX/RDM run. Daisy Chain Layout (DMX/RDM) Data output to next CBX CBX-DS CBX-DS Jumper cable (4 ft LOI shown) Jumper Cable Length Selection Add the length of one fixture to the distance between two fixtures: L + D. Order the next longest jumper cable available: 2, 4 or 0 [0.6m,.2m or 3m] Ex: L + D = 4.ft [.4m] Data input Lumentouch 2.0 distance between two fixtures Ex: 0. ft [0.m] (D) length of fixture (L) Therefore 0 [3m] jumper cable required IP68 LOI-JBOX Accessory - Wiring Detail 00-240V Combined power & data input (From CBX, cable by others) Cap Cable to Maximum 32 DMX/RDM enabled fixtures per DMX/RDM run. 4/ Copyright Lumenpulse 206.877.937.3003 -year limited warranty. Consult
HOW TO ORDER LOID 00/277 RGB DMX/RDM 2 3 4 6 6 Housing: LOID - Lumenfacade Inground Direct View Option: ASL - Anti-slip lens A Lumenfacade Inground fixture includes x optical chamber (LOIC), x power and control box () and x recessed blockout (RBO). The LOIC, and RBO are provided according to the output/color, length and control configuration. 2 Voltage: 00/277-00-277 volts 3 Length: 2-3 /6 inches (33mm) (2.44 kg/.38 lbs) 24-2 /6 inches (636mm) (.23 kg/.3 lbs) 36-37 /6 inches (94mm) (7.03 kg/.0 lbs) 48-49 /6 inches (24mm) (8.84 kg/9.49 lbs) 4 Colors and Color temperatures: RGB - Additive red, green and blue Control: DMX/RDM - DMX/RDM enabled Notes: Fixtures set to by fixture resolution. 3 DMX addresses per RGB fixture. / Copyright Lumenpulse 206.877.937.3003 -year limited warranty. Consult